• Title/Summary/Keyword: RI방사선

Search Result 170, Processing Time 0.031 seconds

Application of Risk-Informed Methods to In-Service Piping Inspection in Framatome Type Nuclear Power Plants (프라마톰형 원전의 배관 가동중검사에 리스크 정보를 활용한 기법 적용)

  • Kim, Jin-Hoi;Lee, Jeong-Seok;Yun, Eun-Sub
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.311-317
    • /
    • 2014
  • The Pressurized water reactor owners group (PWROG) developed and applied a risk-informed in-service inspection (RI-ISI) program, as an alternative to the existing ASME Section XI' sampling inspection method. The RI-ISI programs enhance overall safety by focusing inspections of piping at high safety significance (HSS) locations where failure mechanisms are likely to be present. Additionally, the RI-ISI program can reduce nondestructive evaluation (NDE) exams, man-rem exposure for inspectors, and inspection time, among other benefits. The RI-ISI method of in-service piping inspection was applied to 3 units (KSNPs: Korea standard nuclear power plants) and is being deployed to the other units. In this paper, the results of RI-ISI for a Framatome type (France CPI) nuclear power plant are presented. It was concluded that application of RI-ISI to the plant could enhance and maintain plant safety, as well as provide the benefits of greater reliability.

A Field Tracer Experiment by using RI and Numerical Modelling in River (RI를 이용한 하천 현장실험 및 수치 모델링)

  • Kim, Ki Chul;Chun, Il Young;Jung, Sung Hee;Lee, Jung Lyul;Suh, Kyung Suk
    • Journal of Radiation Industry
    • /
    • v.2 no.3
    • /
    • pp.135-140
    • /
    • 2008
  • A field tracer experiment using radioisotope was carried out to investigate the characteristics of a pollutant transport and a determination of the dispersion coefficients in a river system. The dispersion coefficients in the longitudinal and transverse directions were determined by using the measured concentration of a radioisotope. The two-dimensional numerical models were applied to calculate the flow and concentration fields at the experimental site. Several numerical simulations were performed to investigate the effects of the numerical results according to variations of the dispersion coefficients. The calculated concentrations agreed well with the measured ones.

RI등의 이용 및 현황

  • Korea Radioisotope Association
    • Radioisotope journal
    • /
    • v.12 no.4
    • /
    • pp.78-82
    • /
    • 1997
  • 이 글은 1996년 일본아이소토프협회와 관련기관이 공동 개최한 '제22회 일본아이소토프ㆍ방사선 종합회의'에서 발표된 논문중 일부를 요약하여 연재중이며, 총4회중 마지막 내용임.

  • PDF

Non-clinical Trials using 14C-Acetaminophen to Validate Biomedical Accelerator Mass Spectrometry System (14C-아세트아미노펜 비임상시험을 통한 생체시료 분석용 가속질량분석기의 검증)

  • Jinho Song;Jae Hoon Shim;Jung Bae Park;Chang Su Yeo;Soo Hyeon Bae;Min Sun Choi;Mi Hye Kwon;Kyeong Min Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.127-134
    • /
    • 2023
  • Pharmacokinetic (PK) data provide pivotal information in drug development, and they are usually first studied in the preclinical stage using various animals. However, quite often, animal PK data may not match with human PK, especially in metabolites. Thus, most regulatory agencies in the world make it mandatory to obtain metabolite information using 14C radiolabeled drug in human for small molecule drug candidates. However, such studies are expensive and time consuming and they are usually done at the end of Phase II trials using ~3.7 MBq of 14C labeled drug in a limited number of human subjects. Introduction of accelerator mass spectrometry (AMS) in this kind of study has revolutionized it. Since AMS can measure 14C level as close as natural abundance, it can quantify the amounts of 14C labeled drugs and their metabolites produced in human body that consumes less than the amount of 0.0037 MBq of 14C labeled drug, a very safe level of radioactive dose in human. Therefore, it is now possible to conduct human 14C studies safely in early clinical trials without spending hefty amount of money and time. Korea Radioisotope Center for Pharmaceuticals(KRICP) at Korea Institute of Biological and Medical Sciences(KIRAMS) has established an AMS facility in 2018, housing a 0.5MV AMS manufactured at the US National Electrostatics Corps (NEC). The AMS instrument has been validated using various standard samples that have been prepared at Lawrence Livermore National Laboratory in the US, a worldly reputable provider of AMS standards. In this paper, we present a mass balance study for acetaminophen in rats using AMS and prove that the study results are equivalent with those of literature, which shows the AMS facilities at KRICP has successfully installed and be ready to be used in the various PK studies using 14C labelled compounds for new drug development.

Analysis of Methodology for Designing Education and Training Model for Professional Development in the field of Radiation Technology (방사선 기술 분야 재직자 인력양성을 위한 직무분석에 기반한 교육 모델 설계 방법론 분석)

  • Kim, Kon-Wuk;Lee, Jae-Hun;Park, Tai-Jin;Song, Myung-jae
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • The domestic Radiation Technology is integrated into and utilized in various areas and is closely related to the industrial growth in Korea. The domestic use of radiation and RI (Radioisotope) increases in quantity every year, however the level of technology is poor when compared to other developed countries. Manpower training is essential for the development of Radiation Technology. Therefore, this study aimed to propose a methodology for designing systemic education and training model in the field of measurement and analysis of radiation. A survey was conducted to design education and training model and the training program for measurement and analysis of radiation was developed based on the survey results. The education and training program designed in this study will be utilized as a model for evaluating the professional development and effective recruitment of the professional workforce, and can be further applied to other radiation-related fields.

Study on the Decommissioning of Small Nuclear Facility through Analyzing Foreign Decommissioning Practices (국외 해체 사례 분석을 통한 국내 소규모 방사선이용시설 해체에 관한 연구)

  • Kwon, Dayeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.125-130
    • /
    • 2015
  • RI & RG are used in various field such as medical field, industrial field, agricultural and food&life field. The number of small nuclear facilities is on the increase. We need to take an interest in decommissioning of small nuclear facility and predict the occurring problem from facility decommissioning. Because of the relatively low radiation risk, the preparation of the small nuclear facility dismantling is often neglected. As the accident in Goiania, Brazil showed, the impact of the decommissioning of small nuclear facilities is not less than the large nuclear facilities although it may seem dangerless. Therefore, we analyzed the each institutional characteristics of the decommissioning of small nuclear facilities through foreign case study on this research. Also, we proposed several considerations on decommissioning such as reuse of facility and source, lack of space, stakeholder involvement and failures of protection. Through these study, we tried to make guideline of the small nuclear facilities decommissioning.

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

Synthesis of contrast CT image using deep learning network (딥러닝 네트워크를 이용한 조영증강 CT 영상 생성)

  • Woo, Sang-Keun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.01a
    • /
    • pp.465-467
    • /
    • 2019
  • 본 논문에서는 영상생성이 가능한 딥러닝 네트워크를 이용하여 조영증강 CT 영상을 획득하는 연구를 수행하였다. CT는 고해상도 영상을 바탕으로 환자의 질병 및 암 세포 진단에 사용되는 의료영상 기법 중 하나이다. 특히, 조영제를 투여한 다음 CT 영상을 획득되는 영상을 조영증강 CT 영상이라 한다. 조영증강된 CT 영상은 물질의 구성 성분의 영상대비를 강조하여 임상의로 하여금 진단 및 치료반응 평가의 정확성을 향상시켜준다. 하지많은 수의 환자들이 조영제 부작용을 갖기 때문에 이에 해당되는 환자의 경우 조영증강 CT 영상 획득이 불가능해진다. 따라서 본 연구에서는 조영증강 영상을 얻지 못하는 환자 및 일반 환자의 불필요한 방사선의 노출을 최소화 하기 위하여 영상생성 딥러닝 기법을 이용하여 CT 영상에서 조영증강 CT 영상을 생성하는 연구를 진행하였다. 영상생성 딥러닝 네트워크는 generative adversarial network (GAN) 모델을 사용하였다. 연구결과 아무런 전처리도 거치지 않은 CT 영상을 이용하여 영상을 생성하는 것 보다 히스토그램 균일화 과정을 거친 영상이 더 좋은 결과를 나타냈으며 생성영상이 기존의 실제 영상과 영상의 구조적 유사도가 높음을 확인할 수 있다. 본 연구결과 딥러닝 영상생성 모델을 이용하여 조영증강 CT 영상을 생성할 수 있었으며, 이를 통하여 환자의 불필요한 방사선 피폭을 최소하며, 생성된 조영증강 CT 영상을 바탕으로 정확한 진단 및 치료반응 평가에 기여할 수 있을거라 기대된다.

  • PDF