• Title/Summary/Keyword: RI방사선

Search Result 169, Processing Time 0.025 seconds

A Study on the Measurement Circuit System of RI Gauge (RI 계기의 측정회로 시스템에 관한 연구)

  • 김기준
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1999.05a
    • /
    • pp.217-222
    • /
    • 1999
  • In this study an objection, to be needed at public works, is to develop a measurement circuit of a gauage using radioisotope for compaction control. The developed gauage consists of measuring circuits for gamma-rays and thermal neutrons, a high voltage supply unit, and a microprocessor. To obtain meaningful numbers of pulse counts, parallel five and two circuits are provided for gamma-rays and thermal neutrons, respectively. Also, to minimize effects of natural environmental radiation and electrical noise, circuits are electrostatically shielded and pulses made by ripples are eliminated by taking frequency of high voltage supplied to the circuit and pulse height of ripples into consideration.

  • PDF

Measuring external Radiation dose Ratio by Traits of Patients during Positron Emission Tomography(PET) (양전자단층촬영(PET)시 환자의 특성에 따른 외부 방사선량률 측정)

  • Cho, Yong-Gwi;Kim, Sung-Chul;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.860-868
    • /
    • 2013
  • The purpose of this study is to ensure safety by measuring External radiation dose ratio (ERDR) by traits of patients in many ways after administering radiopharmaceutical($^{18}F$-FDG) for PET Torso scan, and to decrease ERDR of those to RI technologist, caretakers, and those who frequently exposed to radiation by arousing attention to radiation dose. Radiopharmaceutical was administered to 80 patients who conducted PET Torso from January to June, 2013. Radiation dose emitted from the patients was measured according to body shape(BMI), water hydration, height, amount of radiation administration. From the moment immediately after the radiopharmaceutical was administered, ERDR was measured by personal traits of patients. The radiation dose increased in proportion to the administered amount of the radiopharmaceutical, and there was no significant difference depending on the body shape of the patients. When water was supplied and the height was normal, the radiation dose was lower compared with the cases where water was not supplied and height was not normal. There is a need for making efforts to minimize the working time through sufficient education and mock training before those who RI technologist with sources of radiation for complying the radiation safety management rule. And they should minimize the ERDR by wearing a protective gear.

Actual Use of Internet in Curriculum Study of Students in Radiology (방사선 재학생 전공교과목 학습에서 인터넷 활용 실태)

  • Kim, Min-Cheol;Huang, Yuxin;Choi, Ji Hoon;Jung, Hong Ryang;Park, Hae-Ri;Yang, Oh-Nam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.487-491
    • /
    • 2018
  • The purpose of this study was to analyze questionnaires of 161 college students attending radiology departments in order to investigate the actual condition of internet use of radiology students. As a result, 95% of college students using the Internet showed 5.8% of general knowledge, 56.9% of radiation major, and 45.8% of general education. In the field of Internet use, basic medicine was 71.2%, anatomy 59.5% and physiology 51.6%. Radiation theory was 39.9% in radiation physics, 31.4% in radiation biology, and 18.3% in radiation management. The radiological applications were followed by radiography and radiography in order of 31.4% and 20.3%, respectively. The radiological imaging was 45.8%, MRI was 37.9%, CT was 37.3%, ultrasound was 24.2%, And radiation nuclear medicine 25.5%. The results of the descriptive statistics of the satisfaction of the contents using the Internet media showed that the overall satisfaction was below 2.5 Based on the results of this study, it is necessary to develop a program with high accessibility to provide various opportunities for internet-based opportunities to increase the academic achievement value of major subjects through the internet and to solve the difficulties in the major subject.

RI 이리듐-192의 이용현황과 전망

  • 류성렬
    • Nuclear industry
    • /
    • v.15 no.10 s.152
    • /
    • pp.73-78
    • /
    • 1995
  • 이리듐-192(lr-192)는 각종 형태의 암조직의 특성에 맞게 변형하여 적절히 사용되는 특수치료용 동위원소로서, 반감기가 74일로 짧으며 에너지도 낮아 보관$\cdot$관리가 용이하고, 금속 철선 형태로 제작되어 인체내의 암조직에 바늘상태로 자입하는데 편리하게 사용되므로 근접치료에 가장 보편적으로 사용된다. 또한 라듐(Ra-226)이나 세슘(Cs-137)과 달리 시술하는 의료진의 방사선피폭에 전혀 문제가 없다. 원자력병원 연구팀은 최근 이를 이용, 안구 적출없이 안구암흑색종을 치료하는 신기술을 개발한 바 있다.

  • PDF

A Study on the Cardiopulmonary Resuscitation Education of the Medical Workers (의료기관 종사자의 심폐소생술 교육에 관한 연구)

  • Lee, Hyun-Suk;Lim, Cheong-Hwan;Park, Hae-Ri;Jung, Hong-Ryang;Yang, Oh-Nam
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.261-265
    • /
    • 2018
  • Most schools and educational institutions, as well as most companies, show willingness to teach CPR. However, as an essential element for the health care workers, this study aims to analyze the appropriate timing of education and improvements to the education, focusing on those who have trained for CPR. The survey was conducted for only those who applied for CPR education regardless of their profession in medical institutions. There were 105 males and 93 females by gender, and an average of 198 females were 33.5 years. The difference in CPR education depending on individual characteristics showed a high demand that all research subjects' gender, age and marital status should be improved to a practical education. During the education period, the efficiency of CPR was high. It is expected that the education of CPR will be used for the improvement of the training cycle and the training content since it is the enhancement of the performance capabilities that require practical application.

Comparison of Microbiological Safety of Porcine Grafts on Gamma Irradiation for Use of Xenografts (돼지 유래 생체 조직의 이식재 활용을 위한 방사선 조사 미생물 제어 평가)

  • Jo, Eu-Ri;Kim, Jeongsoo;Choi, Jong-il;Kim, Jae-Hun;Sung, Nak-Yun;Song, Beom-Seok;Kim, JaeKyung;Park, Jong-Heum;Lee, Ju-Woon
    • Journal of Radiation Industry
    • /
    • v.5 no.3
    • /
    • pp.279-283
    • /
    • 2011
  • This study was compared microbiological safety with gamma-irradiated porcine tendon and skin, as materials for the development of xenografts to regenerate damaged tissues and protect secondary contamination. The porcine tendon and skin were gamma-irradiated after inoculation of bacteria and virus to evaluate irradiation sensitivity of microorganisms. The result showed that the porcine tendon and skin were not different on the sensitivity of microorganisms by gamma irradiation. Bacteria inoculated in the porcine tendon and skin were confirmed that E. coli was the $D_{10}$ values of $0.32{\pm}0.082$ and $0.25{\pm}0.1kGy$ on tendon and skin, and B. subtilis was $4.00{\pm}0.312$ and $3.88{\pm}0.3kGy$ on gamma irradiation, respectively. Moreover, Virus inoculated in the porcine tendon and skin was observed that poliovirus (PV) was $6.26{\pm}0.332$ and $6.88{\pm}0.3kGy$, and porcine parvovirus (PPV) was $1.75{\pm}0.131$ and $1.73{\pm}0.2kGy$ and bovine viral diarrhoea virus (BVDV) was $3.70{\pm}0.212$ and $3.81{\pm}0.2kGy$ on gamma irradiation, respectively. Virus showed higher resistance compared to bacteria on gamma irradiation, but was not detected CPE (cytopathic effect) by virus both tendon and skin at 25 kGy, a standard dose recommended from IAEA for sterilization of medical products. Therefore, These results were considered that gamma irradiation could control effectively bacteria and virus to develop safe porcine xenograft, and apply same irradiation doses to all tissues including tendon and skin of porcine.

Microbiological Safety and Tensile Strength of Gamma Irradiated Porcine Tendon for the Development of Xenografts (이종이식재 개발을 위한 감마선 조사 돼지 인대의 미생물학적 안전성 및 인장강도)

  • Kim, Jeongsoo;Sung, Nak-Yun;Jo, Eu-Ri;Choi, Jong-il;Song, Beom-Seok;Kim, Jaekyung;Lim, Youn-Mook;Lee, Ju-Woon;Lee, Kwang-Won;Kim, Tae-Woon;Byun, Myung-Woo;Kim, Jae-Hun
    • Journal of Radiation Industry
    • /
    • v.5 no.1
    • /
    • pp.75-80
    • /
    • 2011
  • This study was to determine the microbiological safety and tensile strength of gammairradiated porcine tendon for the development of safe xenografts. Escherichia coli and Bacillus subtilis were used as model pathogens and inoculated as $10^6{\sim}10^7log$ colonies forming unit $(CFU)g^{-1}$. As model virus from porcine, porcine parvovirus (PPV), bovine viral diarrhoea virus (BVDV) and poliovirus were inoculated as $10^5{\sim}10^6$ tissue culture infectious dose $(TCID)_{50}g^{-1}$ into porcine skin. The $D_{10}$ value of E. coli and B. subtilis was measured as $0.32{\pm}0.082kGy$ and $4.0{\pm}0.312kGy$, respectively. Additionally, the $D_{10}$ values of PPV, BVDV and poliovirus were also shown as $1.75{\pm}0.131kGy$, $3.70{\pm}0.212kGy$ and $6.26{\pm}0.332kGy$, respectively. Gamma irradiation decreased the tensile strength of porcine tendon. Results indicate that microbiological safety of porcine tendon can be improved significantly by gamma irradiation. However, further studies are needed to improve the tensile strength of gamma-irradiated porcine tendon.

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

Comparison of Paired and Unpaired Image-to-image Translation for 18F-FDG Delayed PET Generation (18F-FDG PET 지연영상 생성에 대한 딥러닝 이미지 생성 방법론 비교)

  • ALMASLAMANI MUATH;Kangsan Kim;Byung Hyun Byun;Sang-Keun Woo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.07a
    • /
    • pp.179-181
    • /
    • 2023
  • 본 논문에서는 GAN 기반의 영상 생성 방법론을 이용해 delayed PET 영상을 생성하는 연구를 수행하였다. PET은 양전자를 방출하는 방사성 동위원소를 표지한 방사성의약품의 체내 분포를 시각화함으로서 암 세포 진단에 이용되는 의료영상 기법이다. 하지만 PET의 스캔 과정에서 방사성의약품이 체내에 분포하는 데에 걸리는 시간이 오래 걸린다는 문제점이 존재한다. 따라서 본 연구에서는 방사성의약품이 충분히 분포되지 않은 상태에서 얻은 PET 영상을 통해 목표로 하는 충분히 시간이 지난 후에 얻은 PET 영상을 생성하는 모델을 GAN (generative adversarial network)에 기반한 image-to-image translation(I2I)를 통해 수행했다. 특히, 생성 전후의 영상 간의 영상 쌍을 고려한 paired I2I인 Pix2pix와 이를 고려하지 않은 unpaired I2I인 CycleGAN 두 가지의 방법론을 비교하였다. 연구 결과, Pix2pix에 기반해 생성한 delayed PET 영상이 CycleGAN을 통해 생성한 영상에 비해 영상 품질이 좋음을 확인했으며, 또한 실제 획득한 ground-truth delayed PET 영상과의 유사도 또한 더 높음을 확인할 수 있었다. 결과적으로, 딥러닝에 기반해 early PET을 통해 delayed PET을 생성할 수 있었으며, paired I2I를 적용할 경우 보다 높은 성능을 기대할 수 있었다. 이를 통해 PET 영상 획득 과정에서 방사성의약품의 체내 분포에 소요되는 시간을 딥러닝 모델을 통해 줄여 PET 이미징 과정의 시간적 비용을 절감하는 데에 크게 기여할 수 있을 것으로 기대된다.

  • PDF