• 제목/요약/키워드: RFA complication

검색결과 7건 처리시간 0.023초

Radiofrequency Ablation Using a Separable Clustered Electrode for the Treatment of Hepatocellular Carcinomas: A Randomized Controlled Trial of a Dual-Switching Monopolar Mode Versus a Single-Switching Monopolar Mode

  • Jae Won Choi;Jeong Min Lee;Dong Ho Lee;Jung-Hwan Yoon;Yoon Jun Kim;Jeong-Hoon Lee;Su Jong Yu;Eun Ju Cho
    • Korean Journal of Radiology
    • /
    • 제22권2호
    • /
    • pp.179-188
    • /
    • 2021
  • Objective: This study aimed to prospectively compare the efficacy, safety, and mid-term outcomes of dual-switching monopolar (DSM) radiofrequency ablation (RFA) to those of conventional single-switching monopolar (SSM) RFA in the treatment of hepatocellular carcinoma (HCC). Materials and Methods: This single-center, two-arm, parallel-group, randomized controlled study was approved by the Institutional Review Board. Written informed consent was obtained from all patients upon enrollment. A total of 80 patients with 94 HCC nodules were randomized into either the DSM-RFA group or SSM-RFA group in a 1:1 ratio, using a blocked randomization method (block size 2). The primary endpoint was the minimum diameter of the ablation zone per unit time. The secondary endpoints included other technical parameters, complication rate, technique efficacy, and 2-year clinical outcomes. Results: Significantly higher ablation energy per unit time was delivered to the DSM-RFA group than to the SSM-RFA group (1.7 ± 0.2 kcal/min vs. 1.2 ± 0.3 kcal/min; p < 0.001). However, no significant differences were observed between the two groups for the analyzed variables, including primary endpoint, regarding size of the ablation zone and ablation time. Major complication rates were 4.9% in the DSM-RFA group and 2.6% in the SSM-RFA group (p = 1.000). The 2-year local tumor progression (LTP) rates of the HCC nodules treated using DSM-RFA and SSM-RFA were 8.5% and 4.7%, respectively (p = 0.316). The 2-year LTP-free survival rates of patients in the DSM-RFA and SSM-RFA groups were 90.0% and 94.4%, respectively (p = 0.331), and the 2-year recurrence-free survival rates were 54.9% and 75.7%, respectively (p = 0.265). Conclusion: Although DSM-RFA using a separable clustered electrode delivers higher ablation energy than SSM-RFA, its effectiveness failed to show superiority over SSM-RFA in the treatment of HCC.

Efficacy and Safety of Thermal Ablation for Solitary Low-Risk T2N0M0 Papillary Thyroid Carcinoma

  • Yu-Lin Fei;Ying Wei;Zhen-Long Zhao;Li-Li Peng;Yan Li;Shi-Liang Cao;Jie Wu;Hui-Di Zhou;Ming-An Yu
    • Korean Journal of Radiology
    • /
    • 제25권8호
    • /
    • pp.756-766
    • /
    • 2024
  • Objective: To evaluate the efficacy and safety of thermal ablation in treating solitary low-risk T2N0M0 papillary thyroid cancer (PTC) and compare the outcomes of microwave ablation (MWA) and radiofrequency ablation (RFA). Materials and Methods: This retrospective, single center study involved 34 patients (age: 40.0 ± 13.9 years; 28 female) who had low-risk T2N0M0 PTC with a maximum diameter >2 cm and ≤4 cm and underwent MWA (n = 15) or RFA (n = 19) from November 2016 to April 2023. The primary outcomes were the cumulative rate of disease progression and delayed surgery rates. In contrast, the secondary outcomes included changes in tumor size, cumulative rate of complete tumor disappearance, and complication rates. Results: The median follow-up period was 18.0 months (interquartile range [IQR]: 9.0-40.0 months). At 12 months, the median volume reduction rate of the ablation zone was 74.2% (IQR: 53.7%-86.0%). Disease progression was noted in two patients within 1 year, including one patient with local tumor progression post-RFA and one with a new tumor post-MWA, resulting in a constant cumulative disease progression rate of 8.8% (95% confidence interval [CI]: 0%-19.8%) throughout the remaining follow-up period. Both patients were subsequently treated with additional ablation and did not require surgery. The cumulative rates of complete tumor disappearance at 1, 3, and 5 years were 4.0% (95% CI: 0%-11.4%), 26.8% (95% CI: 2.7%-44.9%), and 51.2% (95% CI: 0%-79.1%), respectively. No significant differences were observed in the disease progression (P = 0.829) or complete tumor disappearance (P = 0.633) rates between the MWA and RFA groups. Complications occurred in 14.7% (5/34) of patients presenting with transient hoarseness. RFA had a higher but not statistically significant complication rate than MWA did (21.1% [4/19] vs. 6.7% [1/15]; P = 0.355). Conclusion: Both MWA and RFA demonstrated promising short-term outcomes in terms of efficacy and safety in treating solitary low-risk T2N0M0 PTC, with no significant differences.

Comparison of the Therapeutic Efficacy and Technical Outcomes between Conventional Fixed Electrodes and Adjustable Electrodes in the Radiofrequency Ablation of Benign Thyroid Nodules

  • Jae Ho Shin;Minkook Seo;Min Kyoung Lee;So Lyung Jung
    • Korean Journal of Radiology
    • /
    • 제25권2호
    • /
    • pp.199-209
    • /
    • 2024
  • Objective: This study aimed to compare therapeutic efficacy and technical outcomes between adjustable electrode (AE) and conventional fixed electrode (FE) for radiofrequency ablation (RFA) of benign thyroid nodules. Materials and Methods: Between 2013 and 2021, RFA was performed on histologically proven benign thyroid nodules. For the AE method, AE length ≥ 1 cm with higher power and < 1 cm with lower power were utilized for ablating feeding vessels and nodules, especially those near anatomical structures, respectively. The therapeutic efficacy (volume reduction rate [VRR], complication rate, and regrowth rate) and technical outcomes (total energy delivery, ablated volume/energy, RFA time, and ablated volume/time) of FE and AE were compared. Continuous parameters were compared using a two-sample t-test or Mann-Whitney U test, and categorical parameters were compared using a chi-squared test or Fisher's exact test. Results: A total of 182 nodules (FE: 92 vs. AE: 90) in 173 patients (mean age ± standard deviation, 47.0 ± 14.7 years; female, 90.8% [157/173]; median follow-up, 726 days [interquartile range, 441-1075 days]) were analyzed. The therapeutic efficacy was comparable, whereas technical outcomes were more favorable for AE. Both electrodes demonstrated comparable overall median VRR (FE: 92.4% vs. AE: 84.9%, P = 0.240) without immediate major complications. Overall regrowth rates were comparable between the two groups (FE: 2.2% [2/90] vs. AE: 1.1% [1/90], P > 0.99). AE demonstrated a shorter median RFA time (FE: 811 vs. AE: 627 seconds, P = 0.009). Both delivered comparable median energy (FE: 42.8 vs. AE: 29.2 kJ, P = 0.069), but AE demonstrated higher median ablated volume/energy and median ablated volume/time (FE: 0.2 vs. AE: 0.3 cc/kJ, P < 0.001; and FE: 0.7 vs. AE: 1.0 cc/min, P < 0.001, respectively). Conclusion: Therapeutic efficacy between FE and AE was comparable. AE demonstrated better technical outcomes than FE in terms of RFA time, ablated volume/energy, and ablated volume/time.

Treatment Outcomes of Percutaneous Radiofrequency Ablation for Hepatocellular Carcinomas: Effects of the Electrode Type and Placement Method

  • Jiyeon Park;Min Woo Lee;Soo Hyun Ahn;Seungchul Han;Ji Hye Min;Dong Ik Cha;Kyoung Doo Song;Tae Wook Kang;Hyunchul Rhim
    • Korean Journal of Radiology
    • /
    • 제24권8호
    • /
    • pp.761-771
    • /
    • 2023
  • Objective: To investigate the association among the electrode placement method, electrode type, and local tumor progression (LTP) following percutaneous radiofrequency ablation (RFA) for small hepatocellular carcinomas (HCCs) and to assess the risk factors for LTP. Materials and Methods: In this retrospective study, we enrolled 211 patients, including 150 males and 61 females, who had undergone ultrasound-guided RFA for a single HCC < 3 cm. Patients were divided into four combination groups of the electrode type and placement method: 1) tumor-puncturing with an internally cooled tip (ICT), 2) tumor-puncturing with an internally cooled wet tip (ICWT), 3) no-touch with ICT, and 4) no-touch with ICWT. Univariable and multivariable Cox proportional-hazards regression analyses were performed to evaluate the risk factors for LTP. The major RFA-related complications were assessed. Results: Overall, 83, 34, 80, and 14 patients were included in the ICT, ICWT, no-touch with ICT, and no-touch with ICWT groups, respectively. The cumulative LTP rates differed significantly among the four groups. Compared to tumor puncturing with ICT, tumor puncturing with ICWT was associated with a lower LTP risk (adjusted hazard ratio [aHR] = 0.11, 95% confidence interval [CI] = 0-0.88, P = 0.034). However, the cumulative LTP rate did not differ significantly between tumor-puncturing with ICT and no-touch RFA with ICT (aHR = 0.34, 95% CI = 0.03-1.62, P = 0.188) or ICWT (aHR = 0.28, 95% CI = 0-2.28, P = 0.294). An insufficient ablative margin was a risk factor for LTP (aHR = 6.13, 95% CI = 1.41-22.49, P = 0.019). The major complication rates were 1.2%, 0%, 2.5%, and 21.4% in the ICT, ICWT, no-touch with ICT, and no-touch with ICWT groups, respectively. Conclusion: ICWT was associated with a lower LTP rate compared to ICT when performing tumor-puncturing RFA. An insufficient ablation margin was a risk factor for LTP.

Clinical Application of Transcatheter Arterial Chemoembolization Combined with Synchronous C-arm Cone-Beam CT Guided Radiofrequency Ablation in treatment of Large Hepatocellular Carcinoma

  • Wang, Zhi-Jun;Wang, Mao-Qiang;Duan, Feng;Song, Peng;Liu, Feng-Yong;Wang, Yan;Yan, Jie-Yu;Li, Kai;Yuan, Kai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권3호
    • /
    • pp.1649-1654
    • /
    • 2013
  • Objective: This work aimed to evaluate the safety and clinical efficacy of transcatheter arterial chemoembolization (TACE) combined with c-arm cone-beam CT guided synchronous radiofrequency ablation (RFA) in treatment of large hepatocellular carcinoma (HCC). Methods: 21 patients with large HCC were studied from January 2010 to March 2012. TACE combined with synchronous C-arm cone-beam CT guided RFA were performed on a total of 25 lesions. Conventional imaging examination (CEUS, enhanced CT or MRI) and AFP detection were regularly conducted to evaluate the technical success rate of combined treatment, complications, treatment response, time without disease recurrence and survival rate. Results: The technical success rate of combined treatment was 100%, without any significant complication. After 1 month, there were 19 cases with complete response and 2 cases with partial response, with an complete response rate of 90.4% (19/21) and a clinical effective rate of 100% (21/21). The complete response rates of single nodular lesions (100%, 17/17) was significantly higher than that of multiple nodular lesions (50%, 2/4) (P<0. 05). During 2 to 28 months of follow-up, in 19 cases with complete response, the average time without disease recurrence was $10.8{\pm}6$ months. The total survival rates of 6, 12 and 18 months in 21 patients were 100%, respectively. Conclusion: TACE combined with synchronous C-arm CT guided RFA is safe and effective for treatment of large HCC. The treatment efficacy for single nodular lesion is better than that for multiple nodular lesions.

Comparison of Combined Therapy Using Conventional Chemoembolization and Radiofrequency Ablation Versus Conventional Chemoembolization for Ultrasound-Invisible Early-Stage Hepatocellular Carcinoma (Barcelona Clinic Liver Cancer Stage 0 or A)

  • Lee, Hyukjoon;Yoon, Chang Jin;Seong, Nak Jong;Jeong, Sook-Hyang;Kim, Jin-Wook
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1130-1139
    • /
    • 2018
  • Objective: To compare the therapeutic efficacy between conventional transarterial chemoembolization (cTACE) and combined therapy using cTACE and radiofrequency ablation (RFA) in ultrasound (US)-invisible early stage hepatocellular carcinoma (HCC). Materials and Methods: From January 2008 to June 2016, 167 patients with US-invisible early stage HCCs were treated with cTACE alone (cTACE group; n = 85) or cTACE followed by immediate fluoroscopy-guided RFA targeting intratumoral iodized oil retention (combined group; n = 82). Procedure-related complications, local tumor progression (LTP), time to progression (TTP), and overall survival (OS) were compared between the two groups. Multivariate analyses were performed to identify prognostic factors. Results: There was no major complication in either group. The cTACE group showed higher 1-, 3-, and 5-year LTP rates than the combined group; i.e., 12.5%, 31.7%, and 37.0%, respectively, in the cTACE group; compared to 7.3%, 16.5%, and 16.5%, respectively, in the combined group; p = 0.013. The median TTP was 18 months in the cTACE group and 24 months in the combined group (p = 0.037). Cumulative 1-, 3-, and 5-year OS rates were 100%, 93.2%, and 87.7%, respectively, in the cTACE group and 100%, 96.6%, and 87.4%, respectively, in the combined group (p = 0.686). Tumor diameter > 20 mm and cTACE monotherapy were independent risk factors for LTP and TTP. Conclusion: Combined therapy using cTACE followed by fluoroscopy-guided RFA is a safe and effective treatment in US-invisible early stage HCCs. It provides less LTP and longer TTP than cTACE alone.

상악결절과 다공성 골 미네랄의 복합이식을 통한 상악동 골이식술 (MAXILLARY SINUS AUGMENTATION WITH BOVINE BONE MINERAL(Bio-$Oss^{(R)}$) AND THE MAXILLARY TUBEROSITY)

  • 한기덕;정일혁;이은경;서제덕;송승일
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.391-396
    • /
    • 2007
  • The aim of this study was to evaluate implant stability placed in the maxillary sinus which was augmented with bovine bone mineral(Bio-$Oss^{(R)}$) mixed with autogenous bone from the maxillary tuberosity. Maxillary sinus floor augmentation with the mixture of bovine bone mineral and autogenous maxillary tuberosity bone was performed in 30 maxillary sinuses, and 68 implants were placed at the time of sinus graft. After 6 months of implant placement abutments were connected and implant stability quotient(ISQ) was measured by radio frequency analysis(RFA). In addition, bone level changes was evaluated by taking periapical radiograph. During surgical procedures, no complication was observed, and all patients healed uneventfully. At 6 months the implant showed stable ISQ values. The marginal bone level changes around the fixtures was stably maintained through out the follow up period. This study confirmed that maxillary sinus floor augmentation with mixture of bovine bone mineral and maxillary tuberosity bone could be reliable for bone regeneration in subantral space.