• Title/Summary/Keyword: RF design

Search Result 1,444, Processing Time 0.027 seconds

A Study on Pulse Shaping of Linear Phase filter block with Variable Cutoff Frequency in PCM/FM transmission (PCM/FM 전송에서 가변 컷오프 특성을 갖는 선형위상 필터 블록의 펄스 성형에 관한 연구)

  • Lee Sang-Rae;Ra Sung-Woong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.1C
    • /
    • pp.65-73
    • /
    • 2006
  • The purpose of this study is to design and analyze the pre-modulation filter with the variable -3dB cutoff frequency and linear phase response for bandlimiting the allocation of radio frequency bandwidth in PCM/FM transmission system. For the implementation of this required filter, the digital FIR filter, DAC and variable 2nd order LPF have been constructed with the filter block which designed and analyzed by each stage in order to satisfy the attenuation characteristic requirement of the analog 7th order bessel filter. The paper also concerned the linear phase properties for the filter block. Especially we have carried out the linear phase simulation with real parts for variable 2nd order LPF and compared this simulation results with the one of the fixed bandwidth 2nd order bessel filter for validating the linear phase requirement.

EFFECT OF VARIOUS INODIZING CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANT SURFACE DESIGN (다양한 양극산화막 처리방법이 임프란트 골유착에 미치는 영향)

  • Cha, Soo-Ryun;Lee, Jun;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.417-427
    • /
    • 2008
  • The aim of this study is to investigate the effect of anodizing surface to osseointegration of implant by using of resonance frequency analysis (RFA), quantitative and qualitative assessment of an anodically modified implant type with regard to osseous healing qualities. A total of 96 screw-shaped implants were prepared for this study. 72 implants were prepared by electrochemical oxidation with different ways. 24 (group 1 SP) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid. 24 (group 2GC) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate and 24 (group 3 CMP (Calcium Metaphosphate) Coating were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by CMP coating. Rest of 24 (control group were as a control group of RBM surface. Bone tissue responses were evaluated by resonance frequency analysis (RFA) that were undertaken at 2, 4 and 6 weeks after implant placement in the mandible of mini-pig. Group 1 SP (anodized with sulfuric acid and phosphoric acid implants) demonstrated slightly stronger bone responses than control Group RBM. Group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) demonstrated no difference which were compared with control group. Group 3 GMP (anodized and CMP coated implants) demonstrated slightly stronger and faster bone responses than any other implants. But, all observation result of RF A showed no significant differences between experimental groups with various surface type. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact for group 2 GC. Significantly more bone formation was found inside threaded area for group 2 GC. It was concluded that group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) showed more effects on the bone tissue responses than RBM surface in initial period of implantation. In addition, CMP showed a tendency to promote bone tissue responses.

Development of a Comprehensive Performance Test Facility for Small Millimeter-wave Tracking Radar (소형 추적 레이다용 종합성능시험 시설 개발)

  • Kim, Hong-Rak;Kim, Youn-Jin;Woo, Seon-Keol;An, Se-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.121-127
    • /
    • 2020
  • The small tracking radar targets the target in a real-time, fast-moving, fast-moving target against aircraft with a large RCS that is maneuvering at low speed and a small RCS aircraft maneuvering at high speed (fighters, drones, helicopters, etc.) It is a pulsed radar that detects and tracks. Performing a performance test on a tracking radar in a real environment is expensive, and it is difficult to quantitatively measure performance in a real environment. Describes the composition of the laboratory environment's comprehensive performance test facility and the main requirements and implementation of each configuration.Anechoic chambers to simulate the room environment, simulation target generator to simulate the signal of the room target, target It is composed of a horn antenna driving device to simulate the movement of a vehicle and a Flight Motion Simulatior (FMS) to simulate the flight environment of a tracking radar, and each design and implementation has been described.

Design of Simple Direct Comparison Measurement System from 10 MHz to 1 GHz for Thermistor Mounts Calibration (서미스터 마운트 교정을 위한 10 MHz에서 1 GHz 주파수 대역의 단순 직접 비교 측정시스템 설계)

  • Cha, Yun-Bae;Jang, Young-Guen;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.3
    • /
    • pp.405-412
    • /
    • 2020
  • The thermistor mount is used for precise RF power measurement because the calibration factor is constant according to the change of power. The calibration factor of the standard mount can be measured with an uncertainty less than 0.5 % from the 10 MHz to 1 GHz by direct comparison with the transfer standard using the DC substitution method. Recently, as the supply of precision power meter based on DC substitution method allows simple and fast measurement, a simple direct comparison measurement system with the same level uncertainty was designed and the minimum required specifications of components through analysis of mismatch error was proposed. The uncertainty was evaluated for system validation, and the results show that uncertainties have been well maintained within 0.5 % in the measurement frequencies.

Design Technology of the Wideband Power Amplifier for Electromagnetic Susceptibility Measurement (EMS 측정용 광대역 전력 증폭기 설계기술에 관한 연구)

  • 조광윤;류근관;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8B
    • /
    • pp.1464-1471
    • /
    • 1999
  • A wide-band high power amplifier to use for radiated electromagnetic field immunity testing of EMS(Electromagnetic Susceptibility) standards has to meet IEC1000-4-3 specification in the frequency bandwidth of 80MHz to 1000MHz. The power amplifier to be described in this paper consists of driving and power stages with wide-band matched circuits by estimated impedances. The mismatching protection circuit is inserted in it to prevent from damage of power device when the output port of power amplifier is opened or shorted by user's mistake. The characteristics of the power amplifier are obtained output power over 100watts, gain over 40dB and flatness of $\pm$0.3dB in the frequency range of 80 ~300MHz. The harmonics suppression characteristics is measured over 20dBc. This wide-band high power amplifier can be useful fur radiated electromagnetic field immunity testing of IEC 1000-4-3 standard.

  • PDF

An Application of Support Vector Machines to Customer Loyalty Classification of Korean Retailing Company Using R Language

  • Nguyen, Phu-Thien;Lee, Young-Chan
    • The Journal of Information Systems
    • /
    • v.26 no.4
    • /
    • pp.17-37
    • /
    • 2017
  • Purpose Customer Loyalty is the most important factor of customer relationship management (CRM). Especially in retailing industry, where customers have many options of where to spend their money. Classifying loyal customers through customers' data can help retailing companies build more efficient marketing strategies and gain competitive advantages. This study aims to construct classification models of distinguishing the loyal customers within a Korean retailing company using data mining techniques with R language. Design/methodology/approach In order to classify retailing customers, we used combination of support vector machines (SVMs) and other classification algorithms of machine learning (ML) with the support of recursive feature elimination (RFE). In particular, we first clean the dataset to remove outlier and impute the missing value. Then we used a RFE framework for electing most significant predictors. Finally, we construct models with classification algorithms, tune the best parameters and compare the performances among them. Findings The results reveal that ML classification techniques can work well with CRM data in Korean retailing industry. Moreover, customer loyalty is impacted by not only unique factor such as net promoter score but also other purchase habits such as expensive goods preferring or multi-branch visiting and so on. We also prove that with retailing customer's dataset the model constructed by SVMs algorithm has given better performance than others. We expect that the models in this study can be used by other retailing companies to classify their customers, then they can focus on giving services to these potential vip group. We also hope that the results of this ML algorithm using R language could be useful to other researchers for selecting appropriate ML algorithms.

Radiometer Performance Measure Using A Millimeterwave(Ka-band) Seeker (밀리미터파(Ka-밴드) 탐색기를 이용한 라디오미터 성능 측정)

  • Hong, Young-Gon;Lee, Man-Hee;Ahn, Se-Hwan;Kim, Young-Gon;Kim, Yoon-Jin;Kim, Hong-Rak
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.87-93
    • /
    • 2019
  • We discuss the design of a radiometer using a millimeterwave(Ka-band) seeker. We applied a total power radiometer, thus the radiometer is composed of a IF-drive amp, band-pass filter, detector and an Op-amp additionally. As a radiometer measure a radiated signal of an object which is noise-like, a radiometer is easily affected by the variance of system temperature. To mitigate an adverse effect, we propose a compensation method in a radiometer without brightmess temperature compensation circuits. Through some experiments such like a distinction a target and the background, we have verified that the designed radiometer system has distingushed a car from the ground completely.

Design and implementation of remote controlling wireless transmission unit using duplex-FSK (Duplex-FSK 원격제어 무선 전송부 설계 및 제작)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.629-635
    • /
    • 2009
  • The FSK duplex remote controlling wireless transmission units with a common local oscillator circuit for transmitter and receiver are designed and implemented in this paper. In the FSK full-duplex the channel frequency for Tx/Rx is allocated, a common switching oscillator circuit for Tx/Rx is designed in the FSK half-duplex scheme. Both of FSK units get functions of automatic channel detection for busy channels and channel configuration for an idle channel in order to reduce the RF channel interference and are designed as a remote controller with small-sized low power of 10mW and the 400MHz-colpitz type PLL configuration of 50kHz channel separation. The full-duplex Tx/Rx link frequency gets frequency difference of 42.8MHz, which is double of 21.4MHz IF frequency.

A convergence study of the effect of movement control exercise of hip joint using visual EMG biofeedback on hip rotators (근전도 바이오피드백을 적용한 엉덩관절 움직임 조절 운동이 엉덩관절 돌림근에 미치는 영향에 대한 융합적 연구)

  • Jung, Ju-Hyeon;Kang, Tae-Wook
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.183-189
    • /
    • 2019
  • The aim of this study was to determine the effects of movement control exercise of hip joint using visual EMG biofeedback on hip joint muscles in healthy adults. This study was nonequivalent one group Pre-post test design. Twenty-one healthy adults were participated in the study. all subjects conducted movemnet control exercise(MCE) using electromyography(EMG) biofeedback of hip joint durng 20 min. The outcome measures included surface eletromyography. Surface electromyography data were collected from the Gluteus medius (Gmed), Gluteus maximus (Gmax),and Tensor fasciae latae(TFL), rectus femoris(RF) during small knee bending (SKB) test. There was a significant difference in Gluteus maximus muscle activity between the pre-test and the post-test (p < 0.05). The findings suggest that Movement control exercise using EMG biofeedback for limiting hip internal rotation is effective in activating the hip external rotator muscles. in addition, this study showed that rehabilitation exercise combined with ICT convergence technology could be an effective intervention in clinical practice.

A Comparative Study on Structural Reliability Analysis Methods (구조 신뢰성 해석방법의 고찰)

  • 양영순;서용석
    • Computational Structural Engineering
    • /
    • v.7 no.1
    • /
    • pp.109-116
    • /
    • 1994
  • In this paper, various reliability analysis methods for calculating a probability of failure are investigated for their accuracy and efficiency. Crude Monte Carlo method is used as a basis for the comparison of various numerical results. For the sampling methods, Importance Sampling method and Directional Simulation method are considered for overcoming a drawback of Crude Monte Carlo method. For the approximate methods, conventional Rackwitz-Fiessler method. 3-parameter Chen-Lind method, and Rosenblatt transformation method are compared on the basis of First order reliability method. As a Second-order reliability method, Curvature-Fitting paraboloid method, Point-fitting paraboloid method, and Log-likelihood function method are explored in order to verify the accuracy of the reliability calculation results. These methods mentioned above would have some difficulty unless the limit state equation is expressed explicitly in terms of random design variables. Thus, there is a need to develop some general reliability methods for the case where an implicit limit state equation is given. For this purpose, Response surface method is used where the limit state equation is approximated by regression analysis of the response surface outcomes resulted from the structural analysis. From the application of these various reliability methods to three examples, it is found that Directional Simulation method and Response Surface method are very efficient and recommendable for the general reliability analysis problem cases.

  • PDF