• Title/Summary/Keyword: RF coil

Search Result 173, Processing Time 0.026 seconds

Basic RF Coils Used in Multi-channel RF Coil and Its B1 Field Distribution for Magnetic Resonance Imaging System (자기공명영상 촬영 장치에서 다채널 RF Coil에 이용되는 기본 구조 RF Coil의 B1 Field 분석)

  • Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4891-4895
    • /
    • 2010
  • RF coil is an important component of the Magnetic Resonance Imaging (MRI) system and the performance of RF coil is one of major factors for high SNR images. Sensitivity and RF field uniformity are parameters for evaluating RF coil performance. Since the B1 field is induced by RF coil, MR signal is strongly affected by RF coil structure and arrangement. In receiving MR signal, the RF coil sensitivity to MR Signal is also determined by the induced B1 field of RF coil. Therefore, the spatial distribution of B1 field must be verified. In this work, we performed computer simulation of the basic RF coil structures using Matlab and verified their sensitivity and uniformity through their B1 field distribution. This work will be useful for the advanced multi-channel RF coil design.

Analysis of Endcap Effect for MRI Birdcage RF Coil by FDTD Method (FDTD 방법을 이용한 MRI Birdcage RF Coil의 Endcap 효과 분석)

  • Chung Sung-Taek;Park Bu-Sik;Shin Yoon-Mi;Kwak June-Sik;Cho Jong-Woon;Kim Kyoung-Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.137-143
    • /
    • 2003
  • Purpose : B1 field of birdcage RF (radiofrequency) coil that is used most for brain imaging in magnetic resonance imaging (MRI) decreases toward endring from the coil center. We investigated how much RE B1 homogeneity effect the endcap shield brings form the coil center as it towards to endcap region. Materials and Methods : We compared RF B1 field distribution by each finite difference time domain (EDTD) simulations for lowpass, highpass and hybrid birdcage RF coils. We selected the highpass birdcage RF coil that was the highest RF B1 field condition as simulation result, and studied how much RF B1 homogeneity effect was occurred when endcap shield was applied to endring area. Results : B1 field of the highpass birdcage RF coil was higher than other birdcage RF coil types as simulation result. However, the RF B1 homogeneity was lower than other coil types. RE B1 field of highpass birdcage RF coil with endcap shield is similar with RF B1 field of hybrid birdcage RF coil and the overall RE B1 homogeneity in sagittal direction was better. Conclusion In this paper, proposed method can apply improving RF B1 homogeneity of RF coil in clinical examination.

  • PDF

One-Channel Phased-Array Quadrature RF Coil for Spine Magnetic Resonance Imaging (척추 MRI를 위한 One-Channel Phased-Array Quadrature RF 코일)

  • 양윤정;김선경
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.129-132
    • /
    • 1998
  • A new one-channel phased-array quadrature RF coil is developed for spine MR imaging. Quadrature RF coils for MRI have been used to improve the signal-to-noise ratio (SNR) by$"\squt{2}"$ using two orthogonal RF coils in combination. More recently, the phased-array RF coil has been proposed for more improvement of SNR by using an array of reduced-size RF coil elements. Two schemes proposed for the new phased-array quadrature RF coil are:(1) Proper overlapping of two quadrature RF coils thus removing the mutual inductance and (2) Attaching preamplifiers right after the coil section and combining the signal with proper phase delays. The coil has been implemented for receive-only mode, and tested by phantom and volunteer imaging. The experimental results show the utility of the proposed RF coil.d RF coil.

  • PDF

Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system (고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구)

  • Kim, D.H.;Ko, R.K.;Kang, B.M.;Ha, D.W.;Sohn, M.H.;Mun, C.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.

Phased-Array Quadrature RF Coil for Magnetic Resonance Imaging (자기공명영상촬영을 위한 Phased-Array Quadrature RF 코일)

  • Kim, S.K.;Yang, Y.J.;Lee, D.R.;Ahn, C.B.;Lee, H.K.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.227-229
    • /
    • 1997
  • A new phased-array quadrature RF coil for one or two RF acquisition channels is developed for spine MR imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by $"\sqrt{2}"$ using two orthogonal RF coils in combination [1]. More recently, the phased-array RF coil has been proposed for more improvement of SNR by using an array of RF coil elements with a reduced size and coverage for each element. Two new schemes are proposed for the new phased-array quadrature RF coil as follows : (1) Proper overlapping of two quadrature RF coils thus removing the mutual inductance and (2) Attaching preamplifiers right after the coil section and combining the signal with proper phase delays. The coil has been implemented for receive- only mode. It has been tested through phantom and volunteer imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

An Open Bridcage RF coil for Magnetic Rresonance Imaging (자기공명영상을 위한 개방형 새장 고주파코일)

  • Lee, S.Y.;Yi, J.H.;Yi, W.;Mun, C.W.;Cho, M.H.
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.42-47
    • /
    • 1998
  • Bridcage RF coil is one of the most widely used RF coils in MRI. In order to use birdcage RF coils in open MRI systems, an open tructured birdcage RF coil has been investigated. By opening the ring structure of an original birdcage RF coil and driving the coil at two opening ends, the original birdcage RF coil can be modified to an open structured coil. In order to improve magnetic field uniformity of the open birdcage RF coil, driving voltage phases at the two opening ends can be controlled to be in-phase or out-of-phase each other. Operating frequency of the open birdcage RF coil has been theoretically derived, and the theoretical derivation has been verified by experiments.

  • PDF

Dual Birdcage RF Coil for Leg MR Angiography (하지 MR Angiography를 위한 Dual Birdcage RF 코일)

  • 양윤정;김선경;최환준;김호철;오창현
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.75-78
    • /
    • 1997
  • A dual birdcage RF coil is proposed for MRI and MRA of the human leg. The proposed coil c can be used to cover the whole human leg by imaging upper and lower parts of the leg separately. In the conventional leg imaging scheme using a single RF coil, the leg has to be r relocated when changing the position of the RF coil thus causing problems in matching the i images from two sets of coils. When using the proposed dual RF coil, however, only the bed h has to be moved to select the imaging region while only one part of the dual coil is used each t time by using current switching and PIN diodes. The utility of proposed coil has been verified b by volunteer MRI and MRA and the imaging results show that the coil is useful for the clinical MRI and MRA of the leg.

  • PDF

3.0-Tesla 자기공명 영상장치용 TX/RX C-spine RF Coil의 개발

  • 류연철;류승학;최보영;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.143-143
    • /
    • 2001
  • 목적: 현재 3.0T MRI system은 세계적으로 개발이 진행되고 있는 가운데, 3.0T에서 사용할 수 있는 RF coil의 개발이 시급한 상황이다. 1.0T 및 1.5T MRI 와는 달리 3.0T에서 사용할 수 있는 Body coil 및 그에 따른 High power RF amplifier 제작에 많은 제약이 있다. 작은 용량의 RF amplifier를 이용하여 신체의 부분을 촬영 하고자 한다면, Tx/Rx 가능한 coil을 이용하면 가능할 것이다. 이러한 이유로 본 연구에서는 Tx/Rx 가능한 Quadrature type C-spine RF coil을 설계, 제작하여 3.0T 고자장 자기공명 영상장치에서의 임상진단 활용범위를 확대하였다.

  • PDF

A Open Structure of the Bird-cage RF coil (개방형 구조를 갖는 새장 고주파코일)

  • Lee, S.Y.;Park, B.S.;Yi, J.H.;Yi, W.;Mun, C.W.;Kang, D.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.475-477
    • /
    • 1997
  • A new open structure of the bird-cage RF coil is proposed. By applying in-phase or out-of-phase voltage to the two terminals of the open bird-cage RF coil, desirable level of RF field uniformity has been achieved. Theoretical resonance frequencies of the RF coil has been obtained and compared with experimental ones. The quality factor of the open bird-cage RF coil has been found to be comparable to the one of the conventional RF coil.

  • PDF

Surface Gradient/RF Coil Set for High-Resolution Skin MRI

  • 한재호;김용권;오정민;박상용;오칠환;최보영;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.74-74
    • /
    • 2003
  • 목적: 피부표면에 가까운 고분해능 MR 영상을 얻기 위하여는 Surface RF Coil과 강력한 경사자계를 갖는 Gradient Coil이 필수적으로 요구된다. 본 연구에서는 High-Resolution MR Imaging을 위해 surface RF Coil과 Surface Gradient Coil을 제안하였다. Target Field Method를 사용하여 Gradient Coil의 전력 소모를 최소화하였으며 MR Microscopy가 가능한 50 mm∼100 mm의 해상도가 가능하도록 Coil을 설계하였다.

  • PDF