• 제목/요약/키워드: RF Detector

검색결과 122건 처리시간 0.021초

정전용량변화를 이용한 링거액소진감지장치의 구현 (Implementation of apparatus for detecting Ringer's solution exhaustion using electrostatic capacitance variation)

  • 김청월
    • 센서학회지
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2010
  • Electrostatic capacitance measurement method in a fine hose was proposed, in which two ring-type electrodes were disposed on the hose in the direction of fluid flow instead of the conventional face-to-face electrodes. With the proposed electrode structure, we realized a Ringer's solution exhaustion detector for an IV(invasive vein) injection set. On a 4 mm-diameter hose of IV set, we disposed two ring-type electrodes of 10 mm width at a distance of 5 mm each other and obtained 0.72 pF and 2.51 pF for air and 10 % dextrose Ringer's solution in the hose, respectively. The capacitance between the two electrodes varied with the hose-wraparound coverage of electrode as well as the width of electrode and the distance between the electrodes. For hose-wraparound electrode coverage of 75 %, the capacitance varied from 0.62 pF to 1.98 pF with the Ringer's solution level between the two electrodes. A charge amplifier converted the capacitance. variation into electric signal and a comparator was used to detect whether Ringer's solution was exhausted or not. The result was delivered to a host using a RF transmitter with 320 MHz carrier frequency.

주파수 차이 검출기를 이용한 광파의 off-set 주파수 로킹 연구 (A Study on the Lightwave off-set Locking using Frequency Difference Detector)

  • 유강희
    • 한국정보통신학회논문지
    • /
    • 제8권2호
    • /
    • pp.484-493
    • /
    • 2004
  • 본 논문은 초고주파 주파수 차이 검출기를 이용한 광파의 off-set 로킹에 대하여 설계 및 제작 실험 결과를 기술하였다. 두 광파를 비팅하여 중간 주파수인 1.5GHz 주파수 성분을 추출하고 이 값을 다시 1.5GHz 기준 발진기 주파수와 곱하여 차이주파수 성분을 추출한 후 주파수 차이 검출기를 이용하여 주파수 로킹을 시켰다. 상용화된 초고주파 부품을 사용하여 주파수 차이 검출기를 제작하였으며 1.55$\mu\textrm{m}$ 파장의 반도체 레이저의 발생 광파를 입력 광파와 1.5GHz의 주파수 off-set을 유지하면서 로킹이 이루어짐을 확인하였으며 로킹 범위는 320MHz이었다.

이중대역 적외선 검출기를 이용한 적외선 카메라 설계 (Design of an Infrared Camera using a Dual-band Infrared Detector)

  • 박진호;김홍락;김경일;이다빈
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권5호
    • /
    • pp.93-97
    • /
    • 2022
  • 적외선 영상은 온도 정보뿐만 아니라 파장 정보를 포함하고 있으며 이는 단일 파장의 적외선 카메라로는 분석이 불가능하다. 다중 파장 적외선 카메라는 적외선 영상에 포함된 광범위한 정보를 획득할 수 있다. 다중 파장 적외선 카메라의 한 종류인 이중대역 적외선 카메라는 시스템 구성을 쉽게 할 수 있다는 이점이 있다. 이중대역 적외선 카메라는 적외선 영상에 포함된 온도정보 뿐만 아니라 파장 정보를 획득할 수 있고 이를 통해 적외선 카메라의 탐지/식별 성능을 향상시킬 수 있다. 본 논문에서는 중적외선 대역과 원적외선 대역을 동시에 획득할 수 있는 이중대역 적외선 검출기를 이용한 적외선 카메라의 설계에 대하여 기술한다.

PCM/FM 시스템의 비트 오차 확률에 관한 연구 (A Study on the Bit Error Probability of PC/FM System)

  • 김형일;김영균;이충웅
    • 대한전자공학회논문지
    • /
    • 제20권2호
    • /
    • pp.35-40
    • /
    • 1983
  • 본 논문에서는 PCM/FM시스템에 대한 비트(bit)오차 확률식을 구하여 이를 수치적으로 계산하여 검토를 행했다. 변조전 필터를 거친 NRZ-L 이진 펄스예을 변조 신호로 하여 반송파를 주파수 변조하였고, 리미터와 변별기를 검출기로 이용하였다. RF 스펙트럼의 제한과 비트 오차 확률의 감소면에서 볼 때, 주파수 편이화 h를 3WT가 되도록 설계하는 것이 적당함을 알 수 있었다. 여기서 W는 변조전 필터의 대역폭이고 T는 한 비트당 시간 간폭이다.

  • PDF

비냉각 적외선 검출기용 $V_{1.85}W_{0.15}O_5$ 박막의 구조적, 전기적 특성 (Structural and Electrical Properties of $V_{1.85}W_{0.15}O_5$ Thin Films for the Uncooled Infrared Detector)

  • 남성필;류기원;이성갑;배선기;이영희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.237-238
    • /
    • 2008
  • The films of Vanadium tungsten oxide, $V_{1.85}W_{0.15}O_5$, were grown on Pt/Ti/$SiO_2$/Si substrate by RF sputtering method. The $V_{1.85}W_{0.15}O_5$ thin films deposited on Pt/Ti/$SiO_2$/Si substrates by RF sputtering method exhibited fairly good TCR and dielectric properties. It was found that film crystallinity, dielectric properties, and TCR properties were strongly dependent upon the annealing temperature. The dielectric constants of the $V_{1.85}W_{0.15}O_5$ thin films annealed at $300^{\circ}C$ were 55, with a dielectric loss of 1.435, respectively. Also, the TCR values of the $V_{1.85}W_{0.15}O_5$ thin films annealed at $300^{\circ}C$ were about -3.6%/K.

  • PDF

마이크로 가공 기술을 이용한 강유전체 박막 초전형 적외선 센서 (Pyroelectric infrared microsensors made by micromachining technology)

  • 최준임
    • 전자공학회논문지D
    • /
    • 제35D권4호
    • /
    • pp.93-100
    • /
    • 1998
  • Pyoelectric infrared detectors based on La-modified PbTiO3 (PLT) thin films have been fabricated by RF magnetron sputtering and micromachining technology. The detectors form Pb$_{1-x}$ La$_{x}$Ti$_{1-x}$ O$_{3}$ (x=0.05) thin film ferroelectric capacitors epitaxially grown by RF magnetron sputtering on Pt/MgO (100) substrate. The sputtered PLT thin film exhibits highly c-axis oriented crystal struture that no poling trealization for sensing applications is required. This is an essential factor to increase the yield for realization of an infrared image sensor. Micromachining technology is used to lower the thermal mass of the detector by giving maximum sensor efficiency. Polyimide is coated on top of the sensing elements to support the fragile structure and the backside of the MgO substrate is selectively eteched to reduce the heat loss. The sensing element exhibited a very high detectivity D* of 8.5*10$^{8}$ cm..root.Hz/W at room temperature and it is about 100 times higher than the case of micromachining technology is not used. a sensing system that detects the position as well as the existence of a human body is realized using the array sensor.sor.

  • PDF

Opto-Hertzian 효과를 이용한 고주파 여기식 슬랩 CO2 레이저의 출력 안정화 (Power stabilization of a slab CO2 laser by using the Opto-Hertzian effect)

  • 최종운;우삼용;김규식;이영우
    • 한국광학회지
    • /
    • 제15권4호
    • /
    • pp.337-342
    • /
    • 2004
  • 본 연구에서는 opto-Hertzian 효과를 이용하여 고주파 여기식 슬랩형 $CO_2$ 레이저의 출력을 안정화하였다. 슬랩레이저 공진기속의 복사선 세기가 변화할 때 opto-Hertzian 효과에 의해서 공진기의 방전 임피던스도 함께 변화한다. 이에 따라 공진기로 입사 또는 반사되는 고주파 에너지 값도 변화한다. 이 같은 변화를 결합 루프를 통해 검출하여 고주파 성분을 제거한 후 록인 안정기에서 발생시킨 오차신호를 기준신호로 사용하여 슬랩 레이저의 출력을 안정화하였다. 본 방법으로 안정화된 레이저의 출력 변동률이 0.2%로 개선됨을 확인하였다.

편광 변조 방법에 의한 자기 Kerr 회전각 및 Faraday 회전각 측정 (Measurement of magnetic kerr rotation and faraday fotation angles by polarization modulation method)

  • 이용호;이상수;이용호
    • 한국광학회지
    • /
    • 제3권2호
    • /
    • pp.105-110
    • /
    • 1992
  • 광자기 기록 박막의 자기 광학효과에 의한 미소 편광 회전각을 축정하기 위하여 편광 변조 방법을 이용하였다. 편광 변조 방법은 Faraday 회전자로 레이저광의 편광을 변조하고 phase sensitive detection방법을 써서 변조된 신호만을 선택적으로 검출하는 것이다. 본 실험에서는 진공증착법으로 제작된 TbFeCo박막과 RF 스퍼터링으로 제작된 iron garnet 다결정 박막의 자기 Kerr 회전 및 Faraday 회전 이력곡선을 이 방법으로 조사하였다. 그 결과 $0.25^{\circ}$정도의 미소한 회전각을 측정하였으며 특히 longitudinal Kerr 회전의 경우 $2.5\times10^{-3^\circ}$정도의 매우 작은 회전각도 측정할 수 있었다.

  • PDF

전력 증폭기의 선형화를 위해 2차 고조파와 차주파수를 이용한 전치왜곡 기술 (RF Predistortion Techniques using 2nd Harmonics and Difference Frequency for Linearization of Power Amplifier)

  • 박진상;조경준;장동희;김종헌;이병제;김남영;이종철
    • 한국전자파학회논문지
    • /
    • 제14권4호
    • /
    • pp.356-362
    • /
    • 2003
  • 본 논문에서는 2차 고조파 성분과 차주파수 성분의 새로운 조합을 통해 전력 증폭기에서 발생되는 3차와 5차 혼변조 성분을 개별적으로 조절할 수 있는 전치왜곡 선형화기를 설계 및 제작하였다. 2차 고조파 성분과 차주파수 성분은 포락선 검파기와 두 개의 주파수 체배기를 사용하여 발생시켰다. 제안된 전치왜곡 선형화기는 3차와 5차의 혼변조 성분을 개별적으로 조절하여 전력 증폭기의 선형화 특성을 극대화하였다. 측정 결과, 2137.5~2142.5 MHz 대역의 W-CDMA 1-FA의 30 dBm 출력에서 11 dB ACPR 개선 효과를 얻었다.

무선 및 유비쿼터스 통신을 위한 광 기술 응용의 직접 광/RF 변환 (Conversion of Optical/Radio-frequency by Applying Optical Technology for Wireless and Ubiquitous Communication)

  • 박기환
    • 대한전자공학회논문지TC
    • /
    • 제45권12호
    • /
    • pp.133-138
    • /
    • 2008
  • 본 연구는 미래의 무선 및 유비쿼터스 통신을 위한 광/밀리미터파 신호의 직접 변환(생성) 실험을 50-60 GHz 범위에서 광 기술을 응용하여 성공적으로 수행하였다. 이 실험에서 22.5mW의 광신호가 광 도파로 내에 입사되었고, 밀리미터파 도파관 내부로 방사된 밀리미터파 신호는 밀리미터파 검출기에 의해 검출되었다. 밀리미터파 신호의 스펙트럼 선폭은 1 KHz이하를 나타냈다. 또, 50-60GHz 범위에서, 밀리미터파 신호의 Power 피크치 변위가 1.2dBm 이하인 이득특성을 나타냈다.