• Title/Summary/Keyword: RF Amplifier

Search Result 459, Processing Time 0.03 seconds

Performance Analysis of SLM Method for PAR Reduction Based on OFDM System (OFDM 시스템에서 PAR 감소를 위한 SLM 기법의 성능 분석)

  • Lee, Sang-Geun;Lee, Yoon-Hyun;Jin, Seong-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.1
    • /
    • pp.20-25
    • /
    • 2006
  • In these days, OFDM(Orthogonal Frequency Division Multiplexing) is adopted to support high-speed data communication based on multi-path RF channel, but it has some weak point. One of those is that it has a higher PAR(peak-to-average power ratio) compared with single-carrier method. If some PAR of the transmitted signal is high, nonlinear amplitude distortion has occurred when it pass through the HPA(high power amplifier). There is a solution to prevent nonlinear distortion using higher peak power HPA, but it makes inefficiency and a cost problem. In this paper, we choose the SLM(Selected Mapping) scheme, which transmit the lowest PAR signal after OFDM symbol mapping, in various schemes reducing PAR for OFDM system. And we derived the performances of SLM method in fading channel through computer simulations.

  • PDF

Development of Realtime ECG Analysis and Monitoring System (실시간 심전도 분석 및 모니터링 시스템 개발)

  • Jeong, Gu-Young;Yoon, Myoung-Jong;Yu, Kee-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.4
    • /
    • pp.406-412
    • /
    • 2009
  • ECG is used on purpose to keep good health or monitor cardiac function of aged person as well as on purpose to diagnose the disease of heart patients. The ambulatory ECG monitoring system under guarantee of safety and accuracy is very efficient to prevent the progress of heart disease and sudden death. These systems can detect the temporary change of ECG that is very significant to diagnose heart disease such as myocardial ischemia, arrhyamia and cardiac infarction. In this paper, we describe the ECG signal analysis algorithm and measurement device for ECG monitoring. The authors designed a small-size portable ECG device that consisted of instrumentation amplifier, micro-controller, filter and RF module. The device measures ECG with four electrodes on the body and detects QRS complex and ST level change in realtime. Also it transmits the measured signals to the personal computer. The developed software for ECG analysis in personal computer has the function to detect the feature points and ST level changes.

Variable and Flexible Optical Frequency Comb Source using Dual Mach Zehnder Modulator and Phase Modulator

  • Naveed, Abbas;Choi, Bong-Soo;Tran, ThanhTuan;Seo, Dongsun
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.385-391
    • /
    • 2016
  • We demonstrated experimentally a variable optical frequency comb source using a cascaded dual parallel Mach Zehnder modulator (DPMZM) and a phase modulator (PM). With this simple configuration and applying low drive voltages, we generated variable comb source composed of spectral lines 3, 5, 7, 9 and 11 with 10-GHz frequency spacing, also generated 2 and 3 spectral lines with 20 GHz frequency spacing. The generated comb source maintains high spectral coherence across the entire bandwidth with good spectral flatness (within 1-dB for 2, 3, 5, 7 comb lines, within 2-dB for 9-comb lines and within 3-dB for 11 comb lines). The flat and variable comb source is mainly achieved by manipulating 6 operating parameters of DPMZM, setting RF amplifier gain, connected at phase modulator and phase shifters. Hence the method is simple and offers great flexibility in achieving flat and variable comb spectrum, which is experimentally demonstrated. This brings advantages of power efficiency due to low driving voltages, simplicity and cost effectiveness to the system.

Analysis of Transistor's Circuit Coefficients on the Performance of Active Frequency Multipliers (전력증폭기 트랜지스터 파라미터의 능동 주파수 체배기 성능 영향에 대한 분석)

  • Park, Young-Cheol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.11
    • /
    • pp.1137-1140
    • /
    • 2011
  • In this paper, the optimal condition for efficient active frequency multipliers is analyzed. This analysis is based on the effects from transistor nonlinear coefficients, harmonic impedances, and output parasitic components. From the analysis, normalized harmonic power is estimated with the clipping condition of a commercial transistor, and the condition for high conversion efficiency is suggested. From the analysis, a class-F frequency tripler was implemented for the output at 2.475 GHz, showing the maximum efficiency of 22.9 % and the maximum conversion gain of 9.5 dB.

Estimation of DOA Measurement System using DBF Receiver (DBF 수신기를 이용한 DOA 측정시스템의 평가)

  • Min, Kyeong-Sik;Park, Chul-Keun;Ko, Jee-Won
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.219-223
    • /
    • 2003
  • This paper describes an estimation of DOA(Direction Of Arrival) measurement system using DBF receiver with linear array antenna. This DBF receiver is composed of resistive FET mixer using low IF mettled. A radio frequency(RF), a local oscillator(LO) and ail intermediate frequency(IF) considered in this research are 2.09 GHz, 2.08 GHz and 10 MHz, respectively. This receiver is composed of a band-pass filter, a low-pass filter, a DC bias circuit. DOA measurement system is consist of linear array antenna, DBF receiver, AD control box and computer in the anechoic chamber. Receiving antenna is 4-array monopole antenna and DBF receiver is 4-Ch resistive FET mixer without amplifier. DOA algorithm is implemented using MUSIC algorithm with high resolution. We show that the results of DOA is $-30^{\circ},\;0^{\circ}$ and $60^{\circ}$, respectively. And we know that DOA estimation error occur by antenna radiation pattern and fabrication error of antenna array.

  • PDF

Design of Zigbee based Portable ECG monitoring system (지그비 기반의 휴대형 심전도 모니터링 시스템 설계)

  • Hong, Joo-Hyun;Kim, Nam-Jin;Cha, Eun-Jong;Lee, Tae-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.51-53
    • /
    • 2006
  • This paper proposes a portable ECG monitoring system, which integrates uptodate PDA and RF communication technology. The aim of the study is to acquire the subject's biomedical signal without any constraint. It has two types of transmission mode, which are total signal transmission mode and HR(heart rate)/SC(step count) transmission mode. In audition, wireless communication technology uses Zigbee Wireless PAN and can work in low-power mode, which is one of the advantages of ZiBbee communication technology. The developed system is composed of a transmitter and a receiver. The transmitter has three-axial acceleration sensor. ECG amplifier and Zigbee communication controller. In total signal transmission mode, it can send data 50 packets per second whose transmission speed corresponds to 300 ECG samples and 60 acceleration samples. In HR/SG transmission mode, it can calculate heart rate from EEG data with 216 samples per second and step count from acceleration data and send a packet every cardiac cycle. The receiver forwards the received data to PDA, where the data can be stored and displayed. Therefore, the developed device enables to continuous monitoring for Activities of Daily Living(ADL). Also, this method will reduce medical costs in the aged society.

  • PDF

Fabrication and Characteristics of Surface-Acoustic-Wave Sensors for Detecting $NO_2$ GaS ($NO_2$ 가스 감지를 위한 표면탄성파 센서의 제작 및 특성)

  • Choi, D.H.
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.108-114
    • /
    • 1999
  • Surface acoustic wave (SAW) device is very attractive for gas sensor applications because of their small size, low cost, high sensitivity, and good reliability. A dual delay line surface acoustic wave $NO_2$ gas sensors have been designed and fabricated on the $LiTaO_3$ piezoelectric single crystal substrate. The capacitance of the fabricated IDTs was 326.34pF at the frequency of 79.3MHz. The maximum reflection loss of the impedence-matched IDTs was -16.74dB at the frequency of 79.3MHz. The SAW oscillator was constructed and the stable oscillation was obtained by controlling the gain of rf amplifier properly. The oscillation frequency shift of the SAW oscillator to the $NO_2$ gas was 28Hz/ppm.

  • PDF

Optimization of Operation Frequency of Orthogonal Fluxgate Sensor Fabricated with Co Based Amorphous Wire

  • Kim, Young-Hak;Kim, Yongmin;Yang, Chang-Seob;Shin, Kwang-Ho
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.159-162
    • /
    • 2013
  • We present how to optimize the operation condition including frequency of the orthogonal fluxgate sensor in this paper. The orthogonal fluxgate sensor was fabricated with a Co-based amorphous wire with 10 mm long and 100 ${\mu}m$ in the diameter and a 270-turn pickup coil wound on the amorphous wire. In order to investigate the frequency dependence of the sensitivity, output spectra of the sensor which was connected by using a coaxial cable with various lengths of 0.5-5 m were measured with a RF lock-in amplifier. The maximum sensitivities were obtained at different frequencies according to coaxial cable lengths. It was found that the optimal operation frequencies, at which maximum sensitivities were appeared, were almost identical to the frequencies of impedance resonance. The maximum sensitivity and optimal operation frequency were 1.1 V/Oe (${\approx}$ 11000 V/T) and 1.25 MHz respectively.

Electrical Properties of SiGe HBTs designed with Bottom Collector and Single Metal Layer Structures (Bottom 컬렉터와 단일 금속층 구조로 설계된 SiGe HBT의 전기적 특성)

  • Choi, A-Ram;Choi, Sang-Sik;Kim, Jun-Sik;Yoon, Seok-Nam;Kim, Sang-Hoon;Shim, Kyu-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.661-665
    • /
    • 2007
  • This paper presents the electrical properties of SiGe HBTs designed with bottom collector and single metal layer structure for RF power amplifier. Base layer was formed with graded-SiGe/Si structures and the collector place to the bottom of the device. Bottom collector and single metal layer structures could significantly simplify the fabrication process. We studied about the influence of SiGe base thickness, number of emitter fingers and temperature dependence $(<200^{\circ}C)$ on electrical properties. The feasible application in $1{\sim}2GHz$ frequency from measured data $BV_{CEO}{\sim}10V,\;f_T{\sim}14GHz,\;{\beta}{\simeq}110,\;NF{\sim}1dB$ using packaged SiGe HBTs. We will discuss the temperature dependent current flow through the e-b, b-c junctions to understand stability and performance of the device.

A High Power 60 GHz Push-Push Oscillator Using $0.12{\mu}m$ Metamorphic HEMTs (60 GHz 대역 고출력 $0.12{\mu}m$ MHEMT Push-Push 발진기)

  • Lee, Jong-Wook;Kim, Sung-Won;Kim, Kyoung-Woon;Seol, Gyung-Seon;Kwon, Young-Woo;Seo, Kwang-Seok
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.495-498
    • /
    • 2006
  • This paper reports a high power 60 GHz push-push oscillator fabricated using 0.12 um metamorphic high electron-mobility transistors (mHEMTs). The devices with a $0.1{\mu}m$ gate-length exhibited good DC and RF characteristics such as a maximum drain current of 700 mA/mm, a peak gm of 660 mS/mm, and an $f_T$ of 170 GHz. By combining two sub-oscillators having $6{\times}50{\mu}m$ periphery mHEMT, the push-push oscillator achieved a 6.3 dBm of output power at 59.5 GHz with more than -35 dBc fundamental suppression. This is one of the highest output power obtained using mHEMT technology without buffer amplifier, and demonstrates the potential of mHEMT technology for cost effective millimeter-wave commercial applications.

  • PDF