• Title/Summary/Keyword: RELAP5-3D code

Search Result 10, Processing Time 0.021 seconds

Reactivity feedback effect on loss of flow accident in PWR

  • Foad, Basma;Abdel-Latif, Salwa H.;Takeda, Toshikazu
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1277-1288
    • /
    • 2018
  • In this work, the reactor kinetics capability is used to compute the design safety parameters in a PWR due to complete loss of coolant flow during protected and unprotected accidents. A thermal-hydraulic code coupled with a point reactor kinetic model are used for these calculations; where kinetics parameters have been developed from the neutronic SRAC code to provide inputs to RELAP5-3D code to calculate parameters related to safety and guarantee that they meet the regulatory requirements. In RELAP5-3D the reactivity feedback is computed by both separable and tabular models. The results show the importance of the reactivity feedback on calculating the power which is the key parameter that controls the clad and fuel temperatures to maintain them below their melting point and therefore prevent core melt. In addition, extending modeling capability from separable to tabular model has nonremarkable influence on calculated safety parameters.

Development of the Unified Version of COBRA/RELAP5

  • J. J. Jeong;K. S. Ha;B. D. Chung;Lee, W. J.;S. K. Sim
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.591-598
    • /
    • 1997
  • The COBRA/RELAPS code, an integrated version of the COBRA-TF and RELAP5/MOD3 codes, has been developed for the realistic simulations of complicated, multi-dimensional, two-phase, thermal-hydraulic system transients in light water reactors. Recently, KAERA developed an unified version of the COBRA/RELAP5 code, which can run in serial mode on both workstations and personal computers. This paper provides the brief overview of the code integration scheme, the recent code modifications, the developmental assessments, and the future development plan.

  • PDF

Quantification of Realistic Discharge Coefficients for the Critical Flow Model of RELAP5/MOD3/KAERl (RELAP5 / MOD3/ KAERI의 임계유동모델을 위한 실제적 배출계수의 정량화)

  • Kwon, T.S.;Chung, B.D.;Lee, W.J.;Lee, N.H.;Huh, J.Y.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.701-709
    • /
    • 1995
  • The realistic discharge coefficient for the critical How model of RELAP5/AOD3/KAERI are determined for the subcooled and too-phase critical flow by assessments of nine MARVIKEN Critical flew Test(CFT). The selected test runs include a high initial subcooling and large nozzle aspect rat-io(L/D). The code assessment results show that RELAP5/MOD3/KAERI over-predicts the subcooled critical flow and under-predicts the two-phase critical flow. Using these result, the realistic discharge coefficients of critical flow models are quantified by an iterative method. The realistic discharge coefficients are determined to be 0.89 for the subcooled critical How and 1.07 for the two-phase critical flow, and the associated standard deviations are 0.0349 and 0.1189, respectively. The results obtained from this study can be applied to calculate the realistic system response of Large Break Loss of Coolant Accident and to evaluate the realistic Emergency Core Cooling System performance.

  • PDF

Improvements to the RELAP5/MOD3 Reflood Model and Assessment (RELAP5 /MOD3 재관수 모델의 개선 및 평가)

  • Chung, B.D.;Lee, Y.J.;Park, C.E.;Choi, C.J.;Hwang, T.S.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.265-276
    • /
    • 1994
  • Several improvements to the RELAP5/MOD3 reflood model hate been made. These improvement were made to correct deficiencies in the reflood model identified by the assessment of the RELAP5/MOD3 code against FLECHT-SEASET experiments. The improvements consist of modification of reflood wall heat transfer package and adjusting the droplet size in dispersed flow regime. The time smoothing of wall vaporization and level tracking of transition flow are also added to eliminate the pressure spikes and level oscillation during reflood process. Assessment of the improved model against FLECHT-SEASET experimental data and application of LBLOCA analysis for plant shows that the deficiencies have been corrected.

  • PDF

Quantification of Reactor Safety Margins for Large Break LOCA with Application of Realistic Evaluation Methodology (최적평가 방법론의 적용에 의한 대형냉각재 상실사고시의 원자로 안전여유도의 정량화)

  • B.D. Chung;Lee, Y.J.;T.S. Hwang;Lee, W.J.;Lee, S.Y.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.355-366
    • /
    • 1994
  • The USNRC issued a revised ECCS rule that allows the use of best estimate computer codes for safety analysis. The rule also requires an estimation of uncertainty in calculated system response when applying the best estimate computer codes. A practical realistic evaluation methodology to evaluate the ECCS performance that satisfies the requirements of the ECCS rule has been developed and this paper describes the application of new realistic evaluation methodology to large break LOCA for, the demonstration of the new methodology. The computer code RELAP5/MOD3/KAERI, which was improved from RELAP5/MOD3.1, was used as the best estimate code in the application. The uncertainty of the code was evaluated by assessing several separate and integral effect tests, and for the application to actual plant Kori 3 & 4 was selected as the reference plant. Response surfaces for blowdown and reflood PCTs were generated from the results of the sensitivity analyses and probability distribution functions were established by random sampling or Monte-Carlo method for each response surface. Final uncertainties were quantified at 95% probability level and safety margins for large break LOCA were discussed.

  • PDF

CFD/RELAP5 coupling analysis of the ISP No. 43 boron dilution experiment

  • Ye, Linrong;Yu, Hao;Wang, Mingjun;Wang, Qianglong;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.97-109
    • /
    • 2022
  • Multi-dimensional coupling analysis is a research hot spot in nuclear reactor thermal hydraulic study and both the full-scale system transient response and local key three-dimensional thermal hydraulic phenomenon could be obtained simultaneously, which can achieve the balance between efficiency and accuracy in the numerical simulation of nuclear reactor. A one-dimensional to three-dimensional (1D-3D) coupling platform for the nuclear reactor multi-dimensional analysis is developed by XJTU-NuTheL (Nuclear Thermal-hydraulic Laboratory at Xi'an Jiaotong University) based on the CFD code Fluent and system code RELAP5 through the Dynamic Link Library (DLL) technology and Fluent user-defined functions (UDF). In this paper, the International Standard Problem (ISP) No. 43 is selected as the benchmark and the rapid boron dilution transient in the nuclear reactor is studied with the coupling code. The code validation is conducted first and the numerical simulation results show good agreement with the experimental data. The three-dimensional flow and temperature fields in the downcomer are analyzed in detail during the transient scenarios. The strong reverse flow is observed beneath the inlet cold leg, causing the de-borated water slug to mainly diffuse in the circumferential direction. The deviations between the experimental data and the transients predicted by the coupling code are also discussed.

RELAP5 Analysis of the Loss-of-RHR Accident during the Mid-Loop Operation of Yonggwang Nuclear Units 3/4

  • J. J. Jeong;Kim, W. S.;Kim, K. D.;W. P. Chang
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.403-410
    • /
    • 1995
  • A loss of the residual heat removal (RHR) accident during mid-loop operation of Yong-gwang Nuclear Units 3/4 was analyzed using the RELAP5/MOD3.1.2 code. In this work the following assumptions are used; (i) initially the reactor coolant system (RCS) above the hot leg center line is filled with nitrogen gas, (ii) two 3/4-inch diameter vent valves on the reactor vessel head and the top of pressurizer in the reactor coolant system are always open, and a level indicator is connected to the RMR suction line, (iii) the two steam generators are in wet layup status and the steam generator atmospheric dump valve assemblies are removed so that the secondary side pressure remains at nearly atmospheric condition throughout the accident, and (iv) the loss of RHR is presumed to occur at 48 hours after reactor shutdown. Findings from the RELAP5 calculations are (i) the core boiling begins at ∼5 min, (ii) the peak RCS pressure is ∼3.0 bar, which implies a possibility of temporary seal break, (iii) ∼94 % of the decay heat is removed by reflux condensation in the steam generator U-tubes in spite of the presence of noncondensable gas, (iv) the core uncovery time is evaluated to be 7.2 hours. Significant mass errors were observed in the calculations.

  • PDF

Development of TASS Code for Non-LOCA Safety Analysis Licensing Application (Non-LOCA 인허가 해석용 TASS 코드의 개발)

  • Yoon, Han-Young;Auh, Geun-Sun;Kim, Hee-Cheol;Kim, Joon-Sung;Park, Jae-Don
    • Nuclear Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.53-66
    • /
    • 1995
  • Since the current licensed system codes for Non-LOCA safety analysis are applicable only for a specific type PWR, it is necessary to develope a new system analysis code applicable for all apes of PWRs. As a R&D program, KAERI is developing TASS code as an interactive and faster-than-real-time code for the NSSS transient simulation of both CE and Westinghouse plane. It is flexible tool for PWR analysis which gives the user complete control over the simulation through convenient input and output options. In this paper the code applicability to Westinghouse ape plants was verified by comparing the TASS prediction to plant data of loss of AC power and loss of load transients, and comparing to the prediction of RELAP5/MOD3 for feedline break, locked rotor, steam generator tube rupture and steam line break accidents.

  • PDF

One-Dimensional Analysis of Air-Water Two Phase Natural Circulation Flow (공기와 물의 이상 자연순환 유동의 1 차원 해석)

  • Park, Rae-Joon;Ha, Kwang-Soon;Kim, Jae-Cheol;Hong, Seong-Wan;Kim, Sang-Baik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2626-2631
    • /
    • 2007
  • Air-water two phase natural circulation flow in the T-HERMES (Thermo-Hydraulic Evaluation of Reactor cooling Mechanism by External Self-induced flow)-1D experiment has been evaluated to verify and evaluate the experimental results by using the RELAP5/MOD3 computer code. The RELAP5 results have shown that an increase in the coolant inlet area leads to an increase in the water circulation mass flow rate. However, the water outlet area does not effective on the water circulation mass flow rate. As the coolant outlet moves to a lower position, the water circulation mass flow rate decreases. The water level is not effective on the water circulation mass flow rate. As the height increases in the air injection part, the void fraction increases. However, the void fraction in the upper part of the air injector maintains a constant value. An increase in the air injection mass flow rate leads to an increase in the local void fraction, but it is not effective on the local pressure.

  • PDF

A Systems Engineering Approach to Multi-Physics Analysis of CEA Ejection Accident

  • Sebastian Grzegorz Dzien;Aya Diab
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.19 no.2
    • /
    • pp.46-58
    • /
    • 2023
  • Deterministic safety analysis is a crucial part of safety assessment, particularly when it comes to demonstrating the safety of nuclear power plant designs. The traditional approach to deterministic safety analysis models is to model the nuclear core using point kinetics. However, this simplified approach does not fully reflect the real core behavior with proper moderator and fuel reactivity feedbacks during the transient. The use of Multi-Physics approach allows more precise simulation reflecting the inherent three-dimensionality (3D) of the problem by representing the detailed 3D core, with instantaneous updates of feedback mechanisms due to changes of important reactivity parameters like fuel temperature coefficient (FTC) and moderator temperature coefficient (MTC). This paper addresses a CEA ejection accident at hot full power (HFP), in which the underlying strong and un-symmetric feedback between thermal-hydraulics and reactor kinetics exist. For this purpose, a multi-physics analysis tool has been selected with the nodal kinetics code, 3DKIN, implicitly coupled to the thermal-hydraulic code, RELAP5, for real-time communication and data exchange. This coupled approach enables high fidelity three-dimensional simulation and is therefore especially relevant to reactivity initiated accident (RIA) scenarios and power distribution anomalies with strong feedback mechanisms and/or un-symmetrical characteristics as in the CEA ejection accident. The Systems Engineering approach is employed to provide guidance in developing the work in a systematic and efficient fashion.