• Title/Summary/Keyword: RDE

Search Result 690, Processing Time 0.019 seconds

Discoloration of various CAD/CAM blocks after immersion in coffee

  • Lauvahutanon, Sasipin;Shiozawa, Maho;Takahashi, Hidekazu;Iwasaki, Naohiko;Oki, Meiko;Finger, Werner J.;Arksornnukit, Mansuang
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.9-18
    • /
    • 2017
  • Objectives: This study evaluated color differences (${\Delta}Es$) and translucency parameter changes (${\Delta}TPs$) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Materials and Methods: Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE $L^{\ast}a^{\ast}b^{\ast}$ values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6). The ${\Delta}Es$ and ${\Delta}TPs$ of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (${\alpha}=0.05$). The ${\Delta}Es$ after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results: After one month in coffee, ${\Delta}Es$ of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ${\Delta}TPs$ decreased. The ANOVA of ${\Delta}Es$ and ${\Delta}TPs$ revealed significant differences in two main factors, immersion periods and media, and their interaction except for ${\Delta}Es$ of TEL (Telio CAD, Ivoclar Vivadent). The ${\Delta}Es$ significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between ${\Delta}Es$ and water sorption or solubility in water. Conclusions: The ${\Delta}Es$ of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

Effects of air-abrasion pressure on the resin bond strength to zirconia: a combined cyclic loading and thermocycling aging study

  • Al-Shehri, Eman Z.;Al-Zain, Afnan O.;Sabrah, Alaa H.;Al-Angari, Sarah S.;Dehailan, Laila Al;Eckert, George J.;Ozcan, Mutlu;Platt, Jeffrey A.;Bottino, Marco C.
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.206-215
    • /
    • 2017
  • Objectives: To determine the combined effect of fatigue cyclic loading and thermocycling (CLTC) on the shear bond strength (SBS) of a resin cement to zirconia surfaces that were previously air-abraded with aluminum oxide ($Al_2O_3$) particles at different pressures. Materials and Methods: Seventy-two cuboid zirconia specimens were prepared and randomly assigned to 3 groups according to the air-abrasion pressures (1, 2, and 2.8 bar), and each group was further divided into 2 groups depending on aging parameters (n = 12). Panavia F 2.0 was placed on pre-conditioned zirconia surfaces, and SBS testing was performed either after 24 hours or 10,000 fatigue cycles (cyclic loading) and 5,000 thermocycles. Non-contact profilometry was used to measure surface roughness. Failure modes were evaluated under optical and scanning electron microscopy. The data were analyzed using 2-way analysis of variance and ${\chi}^2$ tests (${\alpha}=0.05$). Results: The 2.8 bar group showed significantly higher surface roughness compared to the 1 bar group (p < 0.05). The interaction between pressure and time/cycling was not significant on SBS, and pressure did not have a significant effect either. SBS was significantly higher (p = 0.006) for 24 hours storage compared to CLTC. The 2 bar-CLTC group presented significantly higher percentage of pre-test failure during fatigue compared to the other groups. Mixed-failure mode was more frequent than adhesive failure. Conclusions: CLTC significantly decreased the SBS values regardless of the air-abrasion pressure used.

Eine verfassungsrechtliche Rechtfertigungspr$\ddot{u}$fung von der Preisbekanntmachung der Individuellen Gesundheitsleistung (비급여진료비용 공개에 관한 헌법적 정당성 고찰)

  • Jung, Young-Chul
    • The Korean Society of Law and Medicine
    • /
    • v.13 no.1
    • /
    • pp.331-357
    • /
    • 2012
  • Obwohl die Preisbekanntmachung der individuellen Gesundheitsleistung(PiG), die im Jahr 2010 im Arztrecht neu eingef$\ddot{u}$hrt wird, zum Management der Gesundheitskosten sehr n$\ddot{u}$tzig werden soll, muss eine verfassungsrechtliche Rechtfertigungspr$\ddot{u}$fung von PiG zun$\ddot{a}$chst durchgef$\ddot{u}$hrt werden. Angesichts der staatlichen Regulierung und Lenkung auf die Wirtschaft des Art. 119 Abs. 2 KV besitzt die PiG zun$\ddot{a}$chst eine Verfassungsrechtfertigung. Nach der st$\ddot{a}$ndigen Rechtsprechung des koreanischen Verfassungsgerichts folgt das Selbstbestimmungsrecht der Verbraucher aus der Menschenw$\ddot{u}$rde von Art. 10 Abs. 1 Koreanische Verfassung(KV) und dem Recht auf Gl$\ddot{u}$ck von Art. 10 Abs. 2 KV. Demnach k$\ddot{o}$nnen Konsumenten den Einkauf der G$\ddot{u}$ter und Service, die Partei des Vertrags, Gesch$\ddot{a}$ftsbedingungen, usw. frei entscheiden. Indem der Preis der individuellen Gesundheitsleistung mithin bekanntgemacht wird, werden das Selbstbestimmungsrecht der Verbraucher sowie das Recht der Konsumenten sicherlich gew$\ddot{a}$hrleistet. Dar$\ddot{u}$ber hinaus steht die PiG im Einklang mit dem Recht auf Information, aber auch z$\ddot{a}$hlt sie nicht zu den Informationen der Nichtbekanntmachung vom Gesetz $\ddot{u}$ber die Bekanntmachung der Information(GBI). Nach der staatlichen Gesundheitspflicht des Art. 36 Abs. 3 KV kann die PiG eine Verfassungslegitim$\ddot{a}$t besitzen. Im Hinblick auf die Berufsfreiheit kann die PiG einen Eingriff in den Gesch$\ddot{a}$ftsaktivit$\ddot{a}$ten der Unternehmen bedeuten. Trotzdem ist die PiG als eine verfassungsrechtliche Legitimit$\ddot{a}$t zu qualifizieren. In der Konsequenz kann die PiG, die auf dem Selbstbestimmungsrecht, dem Recht auf Information, dem Gesundheitsrecht, der Regulierung und Lenkung auf die Wirtschaft von Art. 119 Abs. 2 KV, und dem Recht der Verbraucher beruht, als eine verfassungm${\ddot{a}}{\ss}$ige Politik gesch$\ddot{a}$tzt werden.

  • PDF

Colorimetric comparison of single layered dental composite with double layered dental composite (색상 측정 기기를 이용한 복합레진 적층 수복과 단일 수복의 색상 비교 분석)

  • Song, Young-Sang;Kim, Ja-Hyun;Lee, Bin-Na;Jang, Ji-Hyun;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • Objectives: This study analyzed the difference in color caused by different thickness in enamel layer of composite resins when applied with single and layering placement technique, and evaluated if the results agreed with the shade guide from the manufacturers to verify reliability of the color matching process of the manufacturers. Materials and Methods: For single composite resin samples, 6 mm diameter and 4 mm thickness cylindrical samples were fabricated using Ceram-X mono (DENTSPLY DeTrey) and CIE $L^*a^*b^*$ values were measured with spectrophotometer. Same process was done for layering composite resin samples, making 3 dentinal shade samples, 4 mm thickness, for each shade using Ceram-X duo (DENTSPLY DeTrey) and enamel shade resins were layered in 2 mm thickness and CIE $L^*a^*b^*$ values were measured. These samples were ground to 0.2 mm thickness each time, and CIE $L^*a^*b^*$ values were measured to 1 mm thickness of enamel shade resin. Results: Color difference (${\Delta}E^*$) between single and layering composite resin was 1.37 minimum and 10.53 maximum when layering thicknesses were between 1 mm and 2 mm and 6 out of 10 same shade groups suggested by manufacturer showed remarkable color difference at any thickness (${\Delta}E^*$ > 3.3). Conclusion: When using Ceram-X mono and duo for composite resin restoration, following the manufacturer's instructions for choosing the shade is not appropriate, and more accurate information for Ceram-X duo is needed on the variation and expression of the shades depending on the thickness of the enamel.

Effect of CQ-amine ratio on the degree of conversion in resin monomers with binary and ternary photoinitiation systems

  • Moon, Ho-Jin;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.96-103
    • /
    • 2012
  • Objectives: This study evaluated the effect of camphorquinone (CQ)-amine ratio on the C=C double bond conversion of resins with binary and ternary photoinitiation systems. Materials and Methods: Two monomer mixtures (37.5 Bis-GMA/37.5 Bis- EMA/25 TEGDMA) with binary systems (CQ/DMAEMA in weight ratio, group A [0.5/1.0] and B [1.0/0.5]) and four mixtures with ternary system (CQ/OPPI/DMAEMA, group C [0.1/1.0/0.1], D [0.1/1.0/ 0.2], E [0.2/1.0/0.1] and F [0.2/1.0/0.2]) were tested: 1 : 2 or 2 : 1 CQ-amine ratio in binary system, while 1 : 1 ratio was added in ternary system. The monomer mixture was cured for 5, 20, 40, and 300 sec with a Demetron 400 curing unit (Demetron). After each exposure time, degree of conversion (DC) was estimated using Fourier transform infrared (FTIR) spectrophotometer (Nicolet 520, Nicolet Instrument Corp.). The results were analyzed by ANOVA followed by Scheffe test, with p = 0.05 as the level of significance. Results: DC (%) was expressed in the order of curing time (5, 20, 40, and 300 sec). Group A ($14.63{\pm}10.42$, $25.23{\pm}6.32$, $51.62{\pm}2.69$, $68.52{\pm}2.77$); Group B ($4.04{\pm}6.23$, $16.56{\pm}3.38$, $37.95{\pm}2.79$, $64.48{\pm}1.21$); Group C ($16.87{\pm}5.72$, $55.47{\pm}2.75$, $60.83{\pm}2.07$, $68.32{\pm}3.31$); Group D ($23.77{\pm}1.64$, $61.05{\pm}1.82$, $65.13{\pm}2.09$, $71.87{\pm}1.17$); Group E ($28.66{\pm}2.92$, $56.68{\pm}1.33$, $60.66{\pm}1.17$, $68.78{\pm}1.30$); Group F ($39.74{\pm}6.31$, $61.07{\pm}2.58$, $64.22{\pm}2.29$, $69.94{\pm}2.15$). Conclusion: All the monomers with ternary photoinitiation system showed higher DC than the ones with binary system, until 40 sec. Concerning about the effect of CQ-amine ratio on the DC, group A converted into polymer more than group B in binary system. However, there was no significant difference among groups with ternary system, except group C when cured for 5 sec only.

Effect of the restorative technique on load-bearing capacity, cusp deflection, and stress distribution of endodontically-treated premolars with MOD restoration

  • da Rocha, Daniel Maranha;Tribst, Joao Paulo Mendes;Ausiello, Pietro;Dal Piva, Amanda Maria de Oliveira;Rocha, Milena Cerqueira da;Di Nicolo, Rebeca;Borges, Alexandre Luiz Souto
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.33.1-33.12
    • /
    • 2019
  • Objectives: To evaluate the influence of the restorative technique on the mechanical response of endodontically-treated upper premolars with mesio-occluso-distal (MOD) cavity. Materials and Methods: Forty-eight premolars received MOD preparation (4 groups, n = 12) with different restorative techniques: glass ionomer cement + composite resin (the GIC group), a metallic post + composite resin (the MP group), a fiberglass post + composite resin (the FGP group), or no endodontic treatment + restoration with composite resin (the CR group). Cusp strain and load-bearing capacity were evaluated. One-way analysis of variance and the Tukey test were used with ${\alpha}=5%$. Finite element analysis (FEA) was used to calculate displacement and tensile stress for the teeth and restorations. Results: MP showed the highest cusp (p = 0.027) deflection ($24.28{\pm}5.09{\mu}m/{\mu}m$), followed by FGP ($20.61{\pm}5.05{\mu}m/{\mu}m$), CR ($17.62{\pm}7.00{\mu}m/{\mu}m$), and GIC ($17.62{\pm}7.00{\mu}m/{\mu}m$). For load-bearing, CR ($38.89{\pm}3.24N$) showed the highest, followed by GIC ($37.51{\pm}6.69N$), FGP ($29.80{\pm}10.03N$), and MP ($18.41{\pm}4.15N$) (p = 0.001) value. FEA showed similar behavior in the restorations in all groups, while MP showed the highest stress concentration in the tooth and post. Conclusions: There is no mechanical advantage in using intraradicular posts for endodontically-treated premolars requiring MOD restoration. Filling the pulp chamber with GIC and restoring the tooth with only CR showed the most promising results for cusp deflection, failure load, and stress distribution.

Effect of Polyethylene Glycol on Cu Electrodeposition (구리전해도금에서 폴리에틸렌글리콜(polyethylene glycol)의 영향 연구)

  • An, Eui Gyeong;Choi, Sun Gi;Lee, Jaewon;Cho, Sung Ki
    • Journal of the Korean Electrochemical Society
    • /
    • v.25 no.3
    • /
    • pp.113-118
    • /
    • 2022
  • In this study, the effect of polyethylene glycol (PEG) on Cu electrodeposition was analyzed using cyclic voltammetry. The adsorption of PEG was affected by the specific adsorption of sulfate ion (SO42-) or chloride ion (Cl-). In SO42--based plating solution, the adsorption of PEG was limited by the adsorbed SO42-. Accordingly, the adsorbed PEG could suppress the electron transfer for Cu electrodeposition, but its effect was not significant. Meanwhile, in the plating solution composed of perchlorate ion (ClO4-) which does not specifically adsorb on Cu surface, a strong suppression effect of PEG was observed and it was proportional to the molecular weight of PEG. On the other hand, when Cl- was specifically adsorbed on Cu surface, the suppression effect of PEG was enhanced because PEG and Cl- formed an interrelated adsorbate. The synergetic effect of PEG and Cl- depended on the composition of the plating solution, which means that the synergy between PEG and Cl- is based on the physical interaction. For example, the hydrophobicity of PEG plays an important role in the interaction, as the suppression effect of PEG derivative having a hydrocarbon tail was further enhanced with the addition of Cl-.

High-plasticity mineral trioxide aggregate and its effects on M1 and M2 macrophage viability and adherence, phagocyte activity, production of reactive oxygen species, and cytokines

  • Betania Canal Vasconcellos;Layara Cristine Tomaz Tavares;Danilo Couto da Silva;Francielen Oliveira Fonseca ;Francine Benetti ;Antonio Paulino Ribeiro Sobrinho ;Warley Luciano Fonseca Tavares
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.6.1-6.14
    • /
    • 2023
  • Objectives: This study evaluated the effects of high-plasticity mineral trioxide aggregate (MTA-HP) on the activity of M1 and M2 macrophages, compared to white MTA (Angelus). Materials and Methods: Peritoneal inflammatory M1 (from C57BL/6 mice) and M2 (from BALB/c mice) macrophages were cultured in the presence of the tested materials. Cell viability (MTT and trypan blue assays), adhesion, phagocytosis, reactive oxygen species (ROS) production, and tumor necrosis factor (TNF)-α and transforming growth factor (TGF)-β production were evaluated. Parametric analysis of variance and the non-parametric Kruskal-Wallis test were used. Results were considered significant when p < 0.05. Results: The MTT assay revealed a significant decrease in M1 metabolism with MTA-HP at 24 hours, and with MTA and MTA-HP later. The trypan blue assay showed significantly fewer live M1 at 48 hours and live M2 at 48 and 72 hours with MTA-HP, compared to MTA. M1 and M2 adherence and phagocytosis showed no significant differences compared to control for both materials. Zymosan A stimulated ROS production by macrophages. In the absence of interferon-γ, TNF-α production by M1 did not significantly differ between groups. For M2, both materials showed higher TNF-α production in the presence of the stimulus, but without significant between-group differences. Likewise, TGF-β production by M1 and M2 macrophages was not significantly different between the groups. Conclusions: M1 and M2 macrophages presented different viability in response to MTA and MTA-HP at different time points. Introducing a plasticizer into the MTA vehicle did not interfere with the activity of M1 and M2 macrophages.

Physicochemical properties of a calcium aluminate cement containing nanoparticles of zinc oxide

  • Amanda Freitas da Rosa;Thuany Schmitz Amaral;Maria Eduarda Paz Dotto;Taynara Santos Goulart;Hebert Luis Rossetto;Eduardo Antunes Bortoluzzi;Cleonice da Silveira Teixeira;Lucas da Fonseca Roberti Garcia
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.3.1-3.14
    • /
    • 2023
  • Objectives: This study evaluated the effect of different nanoparticulated zinc oxide (nano-ZnO) and conventional-ZnO ratios on the physicochemical properties of calcium aluminate cement (CAC). Materials and Methods: The conventional-ZnO and nano-ZnO were added to the cement powder in the following proportions: G1 (20% conventional-ZnO), G2 (15% conventional-ZnO + 5% nano-ZnO), G3 (12% conventional-ZnO + 3% nano-ZnO) and G4 (10% conventional-ZnO + 5% nano-ZnO). The radiopacity (Rad), setting time (Set), dimensional change (Dc), solubility (Sol), compressive strength (Cst), and pH were evaluated. The nano-ZnO and CAC containing conventional-ZnO were also assessed using scanning electron microscopy, transmission electron microscopy, and energy-dispersive X-ray spectroscopy. Radiopacity data were analyzed by the 1-way analysis of variance (ANOVA) and Bonferroni tests (p < 0.05). The data of the other properties were analyzed by the ANOVA, Tukey, and Fisher tests (p < 0.05). Results: The nano-ZnO and CAC containing conventional-ZnO powders presented particles with few impurities and nanometric and micrometric sizes, respectively. G1 had the highest Rad mean value (p < 0.05). When compared to G1, groups containing nano-ZnO had a significant reduction in the Set (p < 0.05) and lower values of Dc at 24 hours (p < 0.05). The Cst was higher for G4, with a significant difference for the other groups (p < 0.05). The Sol did not present significant differences among groups (p > 0.05). Conclusions: The addition of nano-ZnO to CAC improved its dimensional change, setting time, and compressive strength, which may be promising for the clinical performance of this cement.

Biological assessment of a new ready-to-use hydraulic sealer

  • Francine Benetti ;Joao Eduardo Gomes-Filho ;India Olinta de Azevedo-Queiroz;Marina Carminatti;Leticia Citelli Conti;Alexandre Henrique dos Reis-Prado ;Sandra Helena Penha de Oliveira ;Edilson Ervolino ;Eloi Dezan-Junior ;Luciano Tavares Angelo Cintra
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.21.1-21.12
    • /
    • 2021
  • Objectives: This study compared the cytotoxicity, biocompatibility, and tenascin immunolabeling of a new ready-to-use hydraulic sealer (Bio-C Sealer) with MTA-Fillapex and white MTA-Angelus. Materials and Methods: L929 fibroblasts were cultivated and exposed to undiluted and diluted material extracts. Polyethylene tubes with or without (the control) the materials were implanted into the dorsa of rats. At 7 days and 30 days, the rats were euthanized, and the specimens were prepared for analysis; inflammation and immunolabeling were measured, and statistical analysis was performed (p < 0.05). Results: MTA-Fillapex exhibited greater cytotoxicity than the other materials at all time points (p < 0.05). The undiluted Bio-C Sealer exhibited greater cytocompatibility at 6 and 48 hours than white MTA-Angelus, with higher cell viability than in the control (p < 0.05). White MTA-Angelus displayed higher cell viability than the control at 24 hours, and the one-half dilution displayed similar results at both 6 and 48 hours (p < 0.05). At 7 days and 30 days, the groups exhibited moderate inflammation with thick fibrous capsules and mild inflammation with thin fibrous capsules, respectively (p > 0.05). At 7 days, moderate to strong immunolabeling was observed (p > 0.05). After 30 days, the control and MTA-Fillapex groups exhibited strong immunolabeling, the white MTA-Angelus group exhibited moderate immunolabeling (p > 0.05), and the Bio-C Sealer group exhibited low-to-moderate immunolabeling, differing significantly from the control (p < 0.05). Conclusions: Bio-C Sealer and white MTA-Angelus exhibited greater cytocompatibility than MTA-Fillapex; all materials displayed adequate biocompatibility and induced tenascin immunolabeling.