• Title/Summary/Keyword: RD-2

Search Result 4,550, Processing Time 0.052 seconds

Evaluation of Tongue Coating by Digital Tongue Diagnosis System between Halitosis and Non-Halitosis Patients. (디지털 설진기를 이용한 구취군과 비구취군 간의 설태 평가)

  • Jung, Yong-Jae;Kim, Jin-Sung;Oh, Sung-Hwan;Han, Ga-Jin;Kim, Yoo-Seung;Hong, In-A;Park, Young-Sun;Park, Jae-Woo;Park, Kyung-Mo;Ryu, Bong-Ha
    • The Journal of Korean Medicine
    • /
    • v.31 no.1
    • /
    • pp.23-29
    • /
    • 2010
  • Objective: The aim of this prospective, case-controlled study was to assess the difference of the amount of tongue coating between halitosis and non-halitosis patients using a digital tongue diagnosis system (DTDS). Methods: Sixty-five patients complaining of oral malodor were recruited for the study. The level of volatile sulfur compounds (VSC) in the oral cavity of the patients was measured by a portable gas chromatography. All patients were then divided into two groups, the halitosis group ($H_2S{\geq}1.5ng$/10ml, or $CH_3SH{\geq}0.5ng$/10ml) and the non-halitosis group ($H_2S$<1.5ng/10ml and $CH_3SH$<0.5ng/10ml), according to the VSC level criteria published by Tonzetich. Tongue images of the two groups were acquired and analyzed by DTDS, followed by the analysis of the tongue coating scores. Results: The tongue coating scores of the halitosis group were significantly higher than of the non-halitosis group (P=0.033). Furthermore, the difference of the posterior tongue coating between the two groups was more significant (P=0.000). Conclusions: Halitosis patients were shown to have a thicker tongue coating than those in the non-halitosis group. Moreover, the posterior dorsum of the tongue should be observed more cautiously when dealing with halitosis patients. Also, the progress and state of the patient's symptom of halitosis as diagnosed objectively by the portable gas chromatography could also possibly be analyzed instead by the DTDS tongue coating score.

Relationship between Halitosis and Gastric Fever Analysed by Questionnaire Cold-Heat Patternization (구취의 한열변증 분석: 구취는 위열증으로 발생하는가?)

  • Lee, Seon-Young;Kim, So-Yeon;Hur, Won-Young;Eom, Guk-Hyeon;Kim, Hyun-Kyung;Lee, Joon-Suk;Yoon, Sang-Hyub;Ryu, Bong-Ha;Kim, Jin-Sung
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.2
    • /
    • pp.500-509
    • /
    • 2006
  • Objectives: We performed this study to check the effect of Cold-Heat attribute analyzed quantitatively by questionnaire on halitosis patient. Methods: We made a questionnaire composed of 15 items(6 categories) about the contents of Cold-Heat and asked 105 subjects to answer in the form Likert-like seven-points score. And then, we extracted Cold-Heat attribute from 15 items, 6 categories, 6 weighted categories, heat score and cold score. On the other hand we measured the halimeter measurements. VAS, winkle tongue coating index. Afterward, the data were analyzed by statistical methods. Results:1) In the 15 items, question number 6, 7, 8 is negative correlated with halimeter measurements. Question number10 is positive correlated with halimeter measurements. And question number 11, 12, 14 is positive correlated with VAS. 2) In the 6 categories, constipation is negative correlated with halimeter measurements. Chill is positive correlated with VAS. And Cold-limbs is positive correlated with halimeter measurements. 3) In the 6 weighted score categories, constipation is negative correlated with halimeter measurements. Chill is positive correlated with VAS. And Cold-limbs is positive correlated with halimeter measurements. Conclusions: Further clinical research is necessary in the development of the questionnaire's items. And to get the better of this study, we should research more analytic method made casual relationship clear between Cold-Heat attributes and the index of halitosis.

  • PDF

Comparative Study on the Efficiency Test Using Remodeled Bubble Generating Pump for Aquarium Fish and Established Air Sampling Pump (관상어용 기포발생기를 개조한 시료채취 장치와 기존의 시료채취기와의 성능 비교)

  • Jang, Bong-Ki;Chun, Jae-Young;Son, Bu-Soon;Lee, Jong-Wha;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.183-191
    • /
    • 2005
  • This study is designed to compare the performance of established samplers (personal air sampler and MiniVOL portable air sampler) commonly used in the air environment or work environment with that of the sampler made by remodeling the air bubble generator for aquarium fishes. Sampling method used in this study is the filter collection method for PM10 and total suspended particles (TSP), the liquid collection method for sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$), and the solid collection method for toluene, respectively. There is not a significant difference in the average concentration of TSP between the Gilian personal air sampler (1st, $0.316{\pm}0.095$; 2nd $0.191{\pm}0.090$; 3rd, $0.185{\pm}0.073mg/m^3$) and the remodeled sampler (1st, $0.317{\pm}0.106$, 2nd $0.201{\pm}0.050$; 3rd $0.189{\pm}0.081mg/m^3$). There are also not significant differences in the average concentration of PM10 among the Gilian personal air sampler ($0.058{\pm}0.006mg/m^3$), the remodeled sampler ($0.052{\pm}0.008mg/m^3$) and the MiniVOL portable air sampler ($0.054{\pm}0.007mg/m^3$). The average concentration of the SO2 by the established sampler and the remodeled one is $3.79{\pm}0.21ppb$ and $3.45{\pm}0.15ppb$, respectively. In addition, there are not sigmficant differences in the average concentration of the NO2 between the Gilian personal air sampler (1st, $0.325{\pm}0.068$; 2nd $0.341{\pm}0.206$; 3rd, $2.971{\pm}0.078{\mu}g/m^3$) and the remodeled sampler (1st, $0.300{\pm}0.062$; 2nd $0.332{\pm}0.144$, 3rd, $2.968{\pm}0.085{\mu}g/m^3$). There are not significant differences in the average concentration of toluene between the Gilian personal air sampler (1st, $0.499{\pm}0.072$; 2nd $0.598{\pm}0.112$; 3rd $2.284{\pm}0.077{\mu}g/m^3$) and the remodeled sampler (1st, $0.463{\pm}0.133$; 2nd $0.603{\pm}0.082$; 3rd $2.353{\pm}0.115{\mu}g/m^3$). From these results, we can conclude that the performance of the remodeled sampler is not different from that of established samplers. There is possibility that the remodeled sampler can be used as a alternative device for Gilian personal air sampler in area and personal air sampling.

Functional Expression of Recombinant Tumstatin in Stably Transformed Drosophila melanogaster S2 Cells

  • Sohn, Bong-Hee;Kim, Yong-Soon;Kang, Pil-Don;Lee, Sang-Uk;Lee, Jong-Min;Chung, In-Sik
    • Proceedings of the Korean Society of Sericultural Science Conference
    • /
    • 2003.10a
    • /
    • pp.147-148
    • /
    • 2003
  • The purpose of this experiment is to confirm whether the recombinant tumstatin revealed from the stably transformed Drosophila melanogaster S2 cells has in vitro capacity. Materials and Methods : Materials - Cell line : Drosophila melanogaster Schneider 2 (S2) cells - vector pMT/BiP/V5-His and pCoHygro (Invitrogen) (omitted)

  • PDF

Children's Self-Esteem : Dimensions and Development (아동의 자아존중감 : 구성영역과 발달)

  • Kim, Hee Haw;Kim, Kyong Yun
    • Korean Journal of Child Studies
    • /
    • v.14 no.1
    • /
    • pp.129-139
    • /
    • 1993
  • The purpose of this study was (1) to explore the dimensions of children's self-esteem and (2) to explain the development of children's self-esteem through a short-term longitudinal approach. 219 children in 1st, 3rd, and 5th grades participated twice once each year over a 2 year period. Factor analysis, Pearson's correlation, Cronbach alpha, pairs t-test, and MANOVA were conducted. Instruments used in this study were made by present researchers. The results showed that (1) children's self-esteem consisted of the cognitive-competence self, peer-related self, teacher-related self, family self, negative self, and physically competent self: (2) the lst and 2nd grade children's self-esteem was higher than that of 3rd-6th grade children and the 3rd grade children's self-esteem changed little until they reached 5th grade, but the 6th grade children's self-esteem decreased.

  • PDF

Soluble Non-ammonia Nitrogen in Ruminal and Omasal Digesta of Korean Native Steers Supplemented with Soluble Proteins

  • Choi, Chang-Weon;Kim, K.H.;Chang, S.S.;Choi, N.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.9
    • /
    • pp.1269-1275
    • /
    • 2012
  • An experiment was conducted to study the effect of soluble protein supplements on concentration of soluble non-ammonia nitrogen (SNAN) in the liquid phase of ruminal (RD) and omasal digesta (OD) of Korean native steers, and to investigate diurnal pattern in SNAN concentration in RD and OD. Three ruminally cannulated Korean native steers in a $3{\times}3$ Latin square design consumed a basal diet of rice straw and corn-based concentrate (control), and that supplemented (kg/d DM basis) with intact casein (0.24; IC) or acid hydrolyzed casein (0.46; AHC). Ruminal digesta was sampled using a vacuum pump, whereas OD was collected using an omasal sampling system at 2.0 h intervals after a morning feeding. The SNAN fractions (free amino acid (AA), peptide and soluble protein) in RD and OD were assessed using the ninhydrin assay. Concentrations of free AA and total SNAN in RD were significantly (p<0.05) lower than those in OD. Although free AA concentration was relatively high, mean peptide was quantitatively the most important fraction of total SNAN in both RD and OD, indicating that degradation of peptide to AA rather than hydrolysis of soluble protein to peptide or deamination may be the most limiting step in rumen proteolysis of Korean native steers. Diurnal variation in peptide concentration in OD for the soluble protein supplemented diets during the feeding cycle peaked 2 h post-feeding and decreased thereafter whereas that for the control was relatively constant during the entire feeding cycle. Diurnal variation in peptide concentration was rather similar between RD and OD.

Analgesic effect of Daeganghwal-Tang on a rat model of CFA-induced arthritis (CFA에 의해 유도된 백서(白鼠)모델 관절염(關節炎)에서 대강활탕(大羌活湯)의 진통효과(鎭痛效果))

  • Seo, Yoon-Jung;Koo, Sung-Tae;Yang, Yoon-Jung;Kim, San;Yoo, In-Sik;Lim, Kyu-Sang
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.83-99
    • /
    • 2004
  • Objectives : Daeganghwal-Tang(DGHT) is one of the prescriptions used for the treatment of rheumatoid arthritis(RA) in oriental medicine. The present study aimed to examine the analgesic effect of DGHT on a rat model of CFA-induced arthritis, and the relations between DGHT-induced analgesia and endogenous nitric oxide(NO) and inducible NO synthase(iNOS)/neuronal NOS. Methods : CFA-induced arthritis model used to test the effect of DGHT was chronic pain model. After the induction of arthritis, rats subsequently showed a reduced stepping force of the affected limb for at least the next 18 days. the reduced stepping force of the limb was presumably due to a painful knee. DGHT dissolved in water was orally administrated. After the treatment, behavioral tests measuring stepping force were periodically conducted during the next 4 hours. Results : DGHT produced significant improvement of stepping force of the hindlimb affected by the arthritis lasting at least 2 hours. DGHT produced the improvement of stepping force of the affected hindlimb in a dose-dependent manner. Both NO production and nNOS/iNOS protein expression which is increased by arthritis were suppressed by DGHT administration. Conclusions : The data suggest 1) that DGHT produces a potent analgesic effect on the chronic knee arthritis pain model in the rat and 2) that DGHT-induced analgesia modulate endogenous NO through the suppression of nNOS/iNOS protein expression.

  • PDF

A Questionnaire Analysis about the Female Patients with Functional Gastrointestinal Disturbance and Effect of Oriental Medical Treatment (설문을 통한 여성 기능성 위장장애 환자의 경향과 한방치료 효과에 대한 연구)

  • Lee, Soo-Jung;Kim, Hyo-Jin;Han, Hyun-Young;Lee, Su-Young;Kim, Jong-Hwan;Kim, Won-Il
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.15 no.2
    • /
    • pp.101-113
    • /
    • 2009
  • Objectives: Nowadays, the number of patients having the Functional Gastrointestinal Disturbance has been on the rise and this tendency is clear in the female group. This study is aimed to investigate their cause of disease, dietary lifestyle, digestion functions, general symptoms and any disadvantages in daily lives etc. Also, it would suggest any effective results from oriental medical treatments. Methods: The total number of 20 female patients, who have been participated in this study, have been treated at Oriental Internal Medicine, Dong-eui Hospital. We have performed the survey with 50 questionnaires. Results: Most patients were having dyspepsia and had been treated more than once before the survey. The major cause of their disease includes irregular eating habits(p<0.05) and stressful mental conditions. The patients had suffered much disadvantages in daily lives and different symptoms. Specially, pain in the below of stomach pit and early satiation were common.(p<0.05) However, the Discomfort index of patients has been decreased from 9.22 point to 2.85 point after oriental medical treatment. It means this treatment has meaningful effectiveness to the Functional Gastrointestinal Disturbance patients. Conclusion: We have investigated the features of female patients with Functional Gastrointestinal Disturbance and conclude that the Oriental Medical Treatment is effective to them.

  • PDF

System Analysis for Receiving Performance Improvement of Mobile Station in PCS (개인휴대통신에서 이동국의 수신성능개선을 위한 시스템 분석)

  • Ju, Jae-Han;Park, Se-Seung;Park, Jong-An;Cheon, Jong-Hun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.1
    • /
    • pp.159-166
    • /
    • 1999
  • In this paper, we examined noise figure and the 3rd order intercept point in sensitivity single tone desensitization, and response attenuation by intermodulation spurious of receiver and also analyzed them through simulation based on J-STD-0.18, which is the minimum specification of PCS mobile station. The result of simulation was as follows ; In sensitivity specification, the total noise figure was 5.99dB and the 3rd order intercept point was -33.979dB. Ins ingle tone desensitization and intermodulation spurious response attenuation specification, the total noise figure was 6.375dB and the 3rd order intercept point was -26.99dBm. When there is an interference tone, the nosie figure and the 3rd order intercept point have been increasedly 0.367dB respectively, compared wit that of no interference tone. Because the amount of increase in the 3rd order intercept point was highly raised more than that of noise figure, mixer, closely related to interference tone should be specified in high 3rd order intercept point. At a frequency spacing of 1.25MHz and 2.05MHz from center frequency in IF SAW filter, attenuation should be more than 45dB.

  • PDF

SAR Test-bed to Acquire Raw Data and Form Real-time Image (실시간 영상형성 및 원시데이터 획득용 SAR 테스트 베드)

  • Shin, Hyun-Ik;Kwon, Kyoung-Il;Yoon, Sang-Ho;Kim, Hyung-Suk;Hwang, Jeonghun;Ko, Young-Chang;You, Eung-Noh;Kim, Jin-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.181-186
    • /
    • 2017
  • Synthetic aperture radar(SAR) has been widely used for reconnaissance. It provides high-resolution, day-and-night and weather-independent images for a multitude of applications. Because SAR coherently combines many viewing angles to effectively create a large aperture(narrow beam) radar, the test-bed should be capable of moving straightly SAR sensor for the integration angle to meet resolution. This paper describes the test-bed developed to test and evaluate the SAR performance. It forms high-quality images in real time and saves the raw data for the purpose of post processing on the ground.