• Title/Summary/Keyword: RC structural wall

Search Result 224, Processing Time 0.019 seconds

Evaluation of Local Damage of SC Wall using Local Collision Simulation (국부충돌해석에 의한 SC벽체의 국부손상 평가)

  • Woo, Dong In;Chung, Chul Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.265-274
    • /
    • 2015
  • The structural safety of nuclear power plant against impact from aircraft crash has been performed so far in two viewpoints such as local behavior and global behavior, and the local behavior has been evaluated using local damage evaluation formulas suggested based on the results of experimental data of RC (Reinforcement Concrete) wall. However, few data have been collected from recent research to evaluate the local behavior and damage of SC (Steel plate reinforced Concrete) wall, which is recently applied to the newly designed nuclear power plant. In this study, local damages of SC wall and RC wall against an idealized aircraft engine projectile impact are evaluated through FE simulation analyses with various wall thicknesses and steel ratio. Through analysis of local collision simulation results of SC and RC wall, the penetration depth of SC wall and RC wall are compared.

Early-Age Behavior of Base Restrained RC Walls (철근콘크리트 벽체의 초기재령 거동 해석)

  • 곽효경;하수준
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.251-258
    • /
    • 2003
  • The early -age behavior of base restrained reinforced concrete (RC) walls is analyzed using a three-dimensional finite element method in this study. After calculating the temperature and internal relative humidity variations of an RC wall, determination of stresses due to thermal gradients, differential drying shrinkage, and average drying shrinkage is followed, and the relative contribution of these three stress components to the total stress is compared. The mechanical properties of early-age concrete, determined from many experimental studies, are taken into consideration, and a discrete reinforcing steel derived using the equivalent nodal force concept is also used to simulate the cracking behavior of RC walls. In advance, to Predict the crack spacing and maximum crack width in a base restrained RC wall, an analytical model which can simulate the post-cracking behavior of an RC tension member is introduced on the basis of the energy equilibrium before and after cracking of concrete.

  • PDF

Reliability assessment of RC shear wall-frame buildings subjected to seismic loading

  • Tuken, Ahmet;Dahesh, Mohamed A.;Siddiqui, Nadeem A.
    • Computers and Concrete
    • /
    • v.20 no.6
    • /
    • pp.719-729
    • /
    • 2017
  • A considerable research is available on the seismic response of Reinforced Concrete (RC) shear wall-frame buildings, but the studies on the reliability of such buildings, with the consideration of human error, are limited. In the present study, a detailed procedure for reliability assessment of RC shear wall-frame building subjected to earthquake loading against serviceability limit state is presented. Monte Carlo simulation was used for the reliability assessment. The procedure was implemented on a 10-story RC building to demonstrate that the shear walls improve the reliability substantially. The annual and life-time failure probabilities of the studied building were estimated by employing the information of the annual probability of earthquake occurrence and the design life of the building. A simple risk-based cost assessment procedure that relates both the structural life-time failure probability and the target reliability with the total cost of the building was then presented. The structural failure probability (i.e., the probability of exceeding the allowable drift) considering human errors was also studied. It was observed that human error in the estimation of total load and/or concrete strength changes the reliability sharply.

Experimental Study on the Retrofit Method to Improve the Structural Capacity of Reinforced Concrete Shear Wall (철근콘크리트 전단벽의 구조성능개선을 위한 보강방안에 관한 실험적 연구)

  • Ha, Gee-Joo;Seo, Soo-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.4
    • /
    • pp.79-86
    • /
    • 2008
  • Four RC shear wall specimens with a/d of 2.2 are designed. And a flexural retrofitting is performed for one specimen by both enlarging wall section and adding additional vertical reinforcements. Also the effectivity of jaketting wall sides is evaluated for the two methods using only steel plate or welded wire mesh with enlargement of section. Cyclic loads are applied to the retrofitted specimens according to the loading history proposed by ACI under constant axial force. Test result showed that the strength and ductility of specimen were improved where the section was enlarged after the installation of additional vertical reinforcements. Confining the ends of wall by U shape W.W.F. with enlargement of section showed most excellent structural capacity regarding to the strength and ductility. Retrofitting by using steel plate was much effective not only to protect the abrupt decrease of strength after yield but also to improve the deformation capacity.

Development of a displacement-based design approach for modern mixed RC-URM wall structures

  • Paparoa, Alessandro;Beyer, Katrin
    • Earthquakes and Structures
    • /
    • v.9 no.4
    • /
    • pp.789-830
    • /
    • 2015
  • The recent re-assessment of the seismic hazard in Europe led for many regions of low to moderate seismicity to an increase in the seismic demand. As a consequence, several modern unreinforced masonry (URM) buildings, constructed with reinforced concrete (RC) slabs that provide an efficient rigid diaphragm action, no longer satisfy the seismic design check and have been retrofitted by adding or replacing URM walls with RC walls. Of late, also several new construction projects have been conceived directly as buildings with both RC and URM walls. Despite the widespread use of such construction technique, very little is known about the seismic behaviour of mixed RC-URM wall structures and codes do not provide adequate support to designers. The aim of the paper is therefore to propose a displacement-based design methodology for the design of mixed RC-URM edifices and the retrofit of URM buildings by replacing or adding selected URM walls with RC ones. The article describes also two tools developed for estimating important quantities relevant for the displacement-based design of structures with both RC and URM walls. The tools are (i) a mechanical model based on the shear-flexure interaction between URM and RC walls and (ii) an elastic model for estimating the contribution of the RC slabs to the overturning moment capacity of the system. In the last part of the article the proposed design method is verified through nonlinear dynamic analyses of several case studies. These results show that the proposed design approach has the ability of controlling the displacement profile of the designed structures, avoiding concentration of deformations in one single storey, a typical feature of URM wall structures.

Evaluation of Structural Behavior of SC Walls in Nuclear Power Plant with Openings (개구부를 갖는 원전 SC구조 벽체의 구조거동 평가)

  • Chung, Chul-Hun;Lee, Han-Joo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5A
    • /
    • pp.277-287
    • /
    • 2012
  • The shear wall with openings built with reinforced concrete (RC) have been elaborately studied by many researchers, whereas the steel plate concrete (SC) wall structure has not been investigated as much. The recent SC wall structures developed in Korea have been partly applied to nuclear power plant structures, although its design specification or guideline for the SC wall structure with openings has not been completed yet. This study based on numerical analysis evaluates the effects of opening on the structural resistance of the SC structure in nuclear power plant. As a result from nonlinear analysis, since the strengthening for openings significantly affect the overall strength of SC wall, the openings should be considered to strengthen them around adjacent area. It is also proved that the strengthened openings have the sufficient resistance and ductility regardless their size, shape, location, and quantity.

Capacity design considerations for RC frame-wall structures

  • Sullivan, Timothy J.
    • Earthquakes and Structures
    • /
    • v.1 no.4
    • /
    • pp.391-410
    • /
    • 2010
  • There are several important considerations that need to be made in the capacity design of RC frame-wall structures. Capacity design forces will be affected by material overstrength, higher mode effects and secondary loadpaths associated with the 3-dimensional structural response. In this paper, the main issues are identified and different means of predicting capacity design forces are reviewed. In order to ensure that RC frame-wall structures perform well it is explained that the prediction of the peak shears and moments that develop in the walls is particularly important and unfortunately very challenging. Through examination of a number of case study structures it is shown that there are a number of serious limitations with capacity design procedures included in current codes. The basis and potential of alternative capacity design procedures available in the literature is reviewed, and a new simplified capacity design possibility is proposed. Comparison with the results of 200 NLTH analyses of frame-wall structures ranging from 4 to 20 storeys suggest that the new method is able to predict wall base shears and mid-height wall moments reliably. However, efforts are also made to highlight the uncertainty with capacity design procedures and emphasise the need for future research on the subject.

Environmental Impact Characteristics Analysis of High-rise Structural System Based on Life Cycle Assessment (전과정평가 기법에 기반한 고층구조시스템의 환경영향특성 분석)

  • Kim, Rak-Hyun;Kim, Young-Hwa;Roh, Seung-Jun;Park, Sang-Hoon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.4
    • /
    • pp.71-79
    • /
    • 2022
  • Recently, the construction of tall buildings utilized by high strength-concrete in the whole world is tending to be on the rise. The application of high-rise structural system in buildings results in the excellent cut-down effect in construction materials due to section reduction. Therefore, in order to investigate the CO2 and resource reduction effect for the high-rise structural system, comparisons of GWP and ADP in embodied energy of structural materlais between 4 type of high-rise structural system have been performed. As a result, GWP emission increased in the order of steel structure outrigger system, RC shear wall system, and RC outrigger system. On the other hand, ADP emissions increased in the order of RC shear wall system, RC outrigger system, and steel structure outrigger system.

Seismic performance of L-shaped RC walls sustaining Unsymmetrical bending

  • Zhang, Zhongwen;Li, Bing
    • Structural Engineering and Mechanics
    • /
    • v.78 no.3
    • /
    • pp.269-280
    • /
    • 2021
  • Reinforced concrete (RC) structural walls with L-shaped sections are commonly used in RC buildings. The walls are often expected to sustain biaxial load and Unsymmetrical bending in an earthquake event. However, there currently exists limited experimental evidence regarding their seismic behaviour in these lateral loading directions. This paper makes experimental and numerical investigations to these walls behaviours. Experimental evidences are presented for four L-shaped wall specimens which were tested under simulated seismic load from different lateral directions. The results highlighted some distinct behaviour of L-shaped walls sustaining Unsymmetrical bending relating to their seismic performance. First, due to the Unsymmetrical bending, out-of-plane reaction forces occur for these walls, which contribute to accumulation of the out-of-plane deformations of the wall, especially when out-of-plane stiffness of the section is reduced by horizontal cracks in the cyclic load. Secondly, cracking was found to affect shear centre of the specimens loaded in the Unsymmetrical bending direction. The shear centre of these specimens distinctly differs in the flange in the positive and negative loading direction. Cracking of the flange also causes significant warping in the bottom part of the wall, which eventually lead to out-of-plane buckling failure.

An equivalent linear SDOF system for prediction of nonlinear displacement demands of non-ductile reinforced concrete buildings with shear walls

  • Saman Yaghmaei-Sabegh;Shabnam Neekmanesh;Nelson Lam;Anita Amirsardari;Nasser Taghizadieh
    • Structural Engineering and Mechanics
    • /
    • v.85 no.5
    • /
    • pp.655-664
    • /
    • 2023
  • Reinforced concrete (RC) shear wall structures are one of the most widely used structural systems to resist seismic loading all around the world. Although there have been several efforts to provide conceptually simple procedures to reasonably assess the seismic demands of structures over recent decades, it seems that lesser effort has been put on a number of structural forms such as RC shear wall structures. Therefore, this study aims to represent a simple linear response spectrum-based method which can acceptably predict the nonlinear displacements of a non-ductile RC shear wall structure subjected to an individual ground motion record. An effective period and an equivalent damping ratio are introduced as the dynamic characteristics of an equivalent linear SDOF system relevant to the main structure. By applying the fundamental mode participation factor of the original MDOF structure to the linear spectral response of the equivalent SDOF system, an acceptable estimation of the nonlinear displacement response is obtained. Subsequently, the accuracy of the proposed method is evaluated by comparison with another approximate method which is based on linear response spectrum. Results show that the proposed method has better estimations for maximum nonlinear responses and is more utilizable and applicable than the other one.