• 제목/요약/키워드: RC precast structures

검색결과 39건 처리시간 0.019초

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 휨 거동 분석 (Analysis on the Flexural Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;손국원
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.52-62
    • /
    • 2015
  • This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.

Overturning of precast RC columns in conditions of moderate ground shaking

  • Kafle, Bidur;Lam, Nelson T.K.;Lumantarna, Elisa;Gad, Emad F.;Wilson, John L.
    • Earthquakes and Structures
    • /
    • 제8권1호
    • /
    • pp.1-18
    • /
    • 2015
  • A simple method of assessing the risk of overturning of precast reinforced concrete columns is presented in this paper. The displacement-based methodology introduced herein is distinguished from conventional force-based codified methods of aseismic design of structures. As evidenced by results from field tests precast reinforced concrete columns can be displaced to a generous limit without sustaining damage and then fully recover from most of the displacement afterwards. Realistic predictions of the displacement demand of such (rocking) system in conjunction with the displacement capacity estimates enable fragility curves for overturning to be constructed. The interesting observation from the developed fragility curves is that the probability of failure of the precast soft-storey column decreases with increasing size of the column importantly illustrating the "size effect" phenomenon.

프리캐스트 콘크리트 모듈러 보 시스템의 휨 성능에 대한 실험적 연구 (An Experimental Study on Flexural Performance of Precast Concrete Modular Beam Systems)

  • 노경민;조창근;이영학
    • 한국공간구조학회논문집
    • /
    • 제21권3호
    • /
    • pp.69-76
    • /
    • 2021
  • Precast concrete (PC) modules have been increased its use in modular buildings due to their better seismic performance than steel modules. The main issue of the PC module is to ensure structural performance with appropriate connection methods. This study proposed a PC modular beam system for simple construction and improved structural and splicing performance. This modular system consisted of modules with steel plates inserted, and it is easy to construct by bolted connection. The steel plates play the role of tensile rebar and stirrup, which has the advantage of structural performance. The structural performance of the proposed PC modular beam system was evaluated by flexural test on one reinforced concrete (RC) beam specimen consisting of a monolithic, and two PC specimens with the proposed PC modular beam system. The results demonstrated that the proposed PC modular beam system achieved approximately 86% of the structural performance compared to the RC monolithic specimen, with similar ductility of approximately 1.06 fold greater.

RC 벽식 아파트의 손상 제어를 위한 PC 비내력벽 시스템의 실험적 평가 (Experimental Evaluation of PC Non-Bearing Wall System for the Damage Control of RC Wall Type Apartments)

  • 문교영;김시윤;김승직;이기학
    • 한국공간구조학회논문집
    • /
    • 제19권4호
    • /
    • pp.77-84
    • /
    • 2019
  • This study introduces a newly developed PC non-bearing wall system to prevent the damage of RC wall-type apartments that have been heavily damaged by the 2017 Pohang Earthquake. In order to evaluate the performance of the developed PC non-bearing wall system, a static cyclic test is conducted. The prototype of test specimen is from the RC wall-type apartment which has been severely damaged by the 2017 Pohang Earthquake. The specimen with the conventional non-bearing wall system showed the similar damage of RC wall type apartment suffered from the Pohang Earthquake. In case of the specimen with the developed PC non-bearing wall system, cracks and damages were not transmitted between the walls due to the seismic slit and there were almost no cracks in the non-bearing walls. Therefore, the proposed non-bearing wall system, separated from the structural walls, could prevent spreading cracks to bearing walls and make it possible to effectively control damage due to earthquake loads.

Experimental seismic behavior of RC special-shaped column to steel beam connections with steel jacket

  • Hao, Jiashu;Ren, Qingying;Li, Xingqian;Zhang, Xizhi;Ding, Yongjun;Zhang, Shaohua
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.101-118
    • /
    • 2022
  • The seismic performance of the reinforced concrete (RC) special-shaped column to steel beam connections with steel jacket used in the RC column to steel beam fabricated frame structures was investigated in this study. The three full-scale specimens were subjected to cyclic loading. The failure mode, ultimate bearing capacity, shear strength capacity, stiffness degradation, energy dissipation capacity, and strain distribution of the specimens were studied by varying the steel jacket thickness parameters. Test results indicate that the RC special-shaped column to steel beam connection with steel jacket is reliable and has excellent seismic performance. The hysteresis curve is full and has excellent energy dissipation capacity. The thickness of the steel jacket is an important parameter affecting the seismic performance of the proposed connections, and the shear strength capacity, ductility, and initial stiffness of the specimens improve with the increase in the thickness of the steel jacket. The calculation formula for the shear strength capacity of RC special-shaped column to steel beam connections with steel jacket is proposed on the basis of the experimental results and numerical simulation analysis. The theoretical values of the formula are in good agreement with the experimental values.

Seismic performances of centrifugally-formed hollow-core precast columns with multi-interlocking spirals

  • Hwang, Jin-Ha;Lee, Deuck Hang;Oh, Jae Yuel;Choi, Seung-Ho;Kim, Kang Su;Seo, Soo-Yeon
    • Steel and Composite Structures
    • /
    • 제20권6호
    • /
    • pp.1259-1274
    • /
    • 2016
  • A precast composite column system has been developed in this study by utilizing multi interlocking spiral steel into a centrifugally-formed hollow-core precast (CHPC) column. The proposed hybrid column system can have enhanced performances in the composite interaction behavior between the hollowed precast column and cast-in-place (CIP) core-filled concrete, the lap splice performance of bundled bars, and the confining effect of concrete. In the experimental program, reversed cyclic loading tests were conducted on a conventional reinforced concrete (RC) column fabricated monolithically, two CHPC columns filled with CIP concrete, and two steel-reinforced concrete (SRC) columns. It was confirmed that the interlocking spirals was very effective to enhance the structural performance of the CHPC column, and all the hollow-core precast column specimens tested in this study showed good seismic performances comparable to the monolithic control specimen.

U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 휨 거동 분석 (Analysis on the Flexural Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel)

  • 손국원;유승룡;임철우;주호성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권5호
    • /
    • pp.56-66
    • /
    • 2015
  • 이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법을 개발하는 것이다. 1개의 무 보강 보-기둥 실험체와 U형 PC 벽패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하였다. 앵커접합 PR1-UA 실험체와 철판접합 PR1-UP 실험체는 무 보강 실험체보다 평균 2.8배(평균 591.8 kN)의 강도 증가를 보여 주었다. 최대 변위비도 1.4%에서 2.7%사이 값을 보여주었다. RC 골조 우측 상단에서 좌측방향으로 가력 할 때 우측에 있는 RC 기둥과 보강 PC 패널의 수직 요소는 완전 합성상태로 가정하였고, 좌측에 있는 RC 기둥과 PC 패널은 완전 비 합성 거동하는 것으로 가정하여 해석한 결과 전체적인 휨 거동은 실험 결과와 대체적으로 부합하는 것으로 판단되었다.

PC Shell 형식 피어캡의 구조성능 평가 (Structural Performance Evaluation for the Precast Shell type Pier Cap)

  • 신성진;황도규;이재훈;손제국;박동규;유동호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.81-82
    • /
    • 2010
  • 교각 급속 시공 기술 개발의 일환으로 피어캡의 프리캐스트화를 위한 설계 및 시공상의 문제점을 분석하였다. 제안된 공법 중 특히 프리캐스트 쉘 형식을 사용하는 방안에 대하여 구조성능을 평가하고 기존 RC 구조와 비교하는 실험 연구를 수행하였다.

  • PDF

Seismic Isolation Systems Incorporating with RC Core Walls and Precast Concrete Perimeter Frames -Shimizu Corporation Tokyo Headquarter-

  • Shimazaki, Dai;Nakagawa, Kentaro
    • 국제초고층학회논문집
    • /
    • 제4권3호
    • /
    • pp.181-189
    • /
    • 2015
  • Shimizu Corporation Tokyo Headquarters, one of the city's leading office buildings, features many pioneering technologies that contribute to a sustainable society through environmental stewardship and a sophisticated disaster management facility. In terms of structural engineering, a seismic isolation system incorporating reinforced concrete core walls and precast concrete perimeter frames create a robust structure in the event of a large earthquake. In addition to the seismic resistance of the structure, several pioneering construction methods and materials are adopted. This office building can serve as a basis for new design and construction approaches and methodologies to ensure safe and economical structures.

외부 앵커압착형 프리캐스트 벽체로 보강된 비내진 상세를 갖는 철근콘크리트 골조에 대한 실험적 연구 (Experimental Study on RC Frame Structures with Non-Seismic Details Strengthened by Externally-Anchored Precast Wall-Panel Method (EPWM))

  • 최승호;황진하;이득행;김강수;권용근;김길희
    • 콘크리트학회논문집
    • /
    • 제27권4호
    • /
    • pp.451-458
    • /
    • 2015
  • 비내진 상세를 갖는 노후된 철근콘크리트 골조의 내진보강을 위해 철근콘크리트 끼움벽 공법이 많이 사용되고 있다. 기존 콘크리트 골조에 끼움벽을 이용하여 보강하는 방법은 지진과 같은 횡력에 대하여 높은 강도를 확보할 수 있는 방법이다. 그러나, 기존의 끼움벽공법은 공사기간동안 이용자의 사용이 제한될 수 밖에 없으며, 접합부의 시공이 어렵고, 접합부의 합성성능을 확보하기 어려운 측면이 있다. 이 연구에서는 기존 끼움벽 공법의 단점을 개선하기 위하여 공장제작된 프리캐스트 콘크리트 벽체를 건물의 외부에서 압착하여 보강하는 방법을 제안하였다. 제안된 공법을 검증하기 위하여 반복하중을 받는 총 4개의 1/3축소 실험체들을 제작하여 실험을 수행하였으며, 제안된 공법이 적용된 철근콘크리트 골조의 강도, 강성, 에너지 소산 능력이 크게 향상되는 것을 실험적으로 확인하였다.