• 제목/요약/키워드: RC control

검색결과 574건 처리시간 0.029초

체적제어법에 의한 철근 콘크리트 원통형 구조물의 파괴 해석 (Failure Analysis of RC Cylindrical Structures using Volume-Control Method)

  • 송하원;방정용;변근주
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.195-202
    • /
    • 1999
  • In this Paper, a so-called volume-control method for nonlinear failure analysis of reinforced concrete cylindrical structures is proposed. The pressure node which defines uniform change of pressure on finite element is added into layered shell element utilizing in-plane constitutive models of reinforced concrete and layered formulation. With the pressure node formulation, one can control the change in volume enclosed by the cylindrical structures and determine the required change in pressure. An algorith of volume-control method is employed and failure analyses for RC cylindrical structures are carried out using proposed method.

  • PDF

변전소의 보호.제어를 위한 디지탈 시스템 개발 PART 2 - 광 통신망 개발 (Development of a Digital System for Protection and Control of a Substation Part 2 - Development of Fiber Optic Network)

  • 권옥현;박상환;김명준;이영일;박혁기;문영수;윤만철;김일동;이제헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.362-364
    • /
    • 1992
  • In this paper, the development of a fiber optic network for an integrated digital protection relay system is described. The structure of the developed network is determined to loosen the optic requirements and to have good extensibility while providing sufficient functions for protection and control for substations. The network has a hierarchical structure with two levels. The upper level handles data for monitoring and control of the system with star topology. The lower level manages the real time data for bus protection with one-to-one connections. Communication flows of each level are described. The HDLC is employed as the network protocol.

  • PDF

변전소의 보호.제어를 위한 디지탈 시스템 개발 PART 1 - 하드웨어 개발 (Development of a Digital System for Protection and Control of a Substation Part 1 - Development of hardware)

  • 권옥현;이영일;박혁기;박상환;김명준;문영수;윤만철;김일동;이제헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.359-361
    • /
    • 1992
  • This paper describes the development of an Integrated Digital Protection And Control System (IDPACS) for 345 KV substation. The developed IDPACS system containes digital protection units for transmission lines, delivery lines, transformers, bus, shunt reactors and Shunt capacitors. We deloped a Local Area Network (LAN) Which connects the digital protection units to the station computer for monitoring and control purposes.

  • PDF

Experimental study on RC frame structures strengthened by externally-anchored PC wall panels

  • Choi, Seung-Ho;Hwang, Jin-Ha;Lee, Deuck Hang;Kim, Kang Su;Zhang, Dichuan;Kim, Jong Ryeol
    • Computers and Concrete
    • /
    • 제22권4호
    • /
    • pp.383-393
    • /
    • 2018
  • Infill wall strengthening method has been widely used for seismic strengthening of deteriorated reinforced concrete (RC) frame structures with non-seismic details. Although such infill wall method can ensure sufficient lateral strengths of RC frame structures deteriorated in seismic performances with a low constructional cost, it generally requires quite cumbersome construction works due to its complex connection details between an infill wall and existing RC frame. In this study, an advanced seismic strengthening method using externally-anchored precast wall panels (EPCW) was developed to overcome the disadvantage inherent in the existing infill wall strengthening method. A total of four RC frame specimens were carefully designed and fabricated. Cyclic loading tests were then conducted to examine seismic performances of RC frame specimens strengthened using the EPCW method. Two specimens were fully strengthened using stocky precast wall panels with different connection details while one specimen was strengthened only in column perimeter with slender precast wall panels. Test results showed that the strength, stiffness, and energy dissipation capacity of RC frame specimens strengthened by EPCWs were improved compared to control frame specimens without strengthening.

Flexural strengthening of RC one way solid slab with Strain Hardening Cementitious Composites (SHCC)

  • Basha, Ali;Fayed, Sabry;Mansour, Walid
    • Advances in concrete construction
    • /
    • 제9권5호
    • /
    • pp.511-527
    • /
    • 2020
  • The main aim of the current research is to investigate the flexural behavior of the reinforced concrete (RC) slabs strengthened with strain hardening cementitious composites (SHCC) experimentally and numerically. Seven RC slabs were prepared and tested under four-points loading test. One un-strengthened slab considered as control specimen while six RC slabs were strengthened with reinforced SHCC layers. The SHCC layers had different reinforcement ratios and different thicknesses. The results showed that the proposed strengthening techniques significantly increased the ultimate failure load and the ductility index up to 25% and 22%, respectively, compared to the control RC slab. Moreover, a three dimensional (3D) finite element model was proposed to analyze the strengthened RC slabs. It was found that the results of the proposed numerical model well agreed with the experimental responses. The validated numerical model used to study many parameters of the SHCC layer such as the reinforcement ratios and the different thicknesses. In addition, steel connectors were suggested to adjoin the concrete/SHCC interface to enhance the flexural performance of the strengthened RC slabs. It was noticed that using the SHCC layer with thickness over 40 mm changed the failure mode from the concrete cover separation to the SHCC layer debonding. Also, the steel connectors prevented the debonding failure pattern and enhanced both the ultimate failure load and the ductility index. Furthermore, a theoretical equation was proposed to predict the ultimate load of the tested RC slabs. The theoretical and experimental ultimate loads are seen to be in fairly good agreement.

RC 계단실 연속화 시공을 위한 PC 계단 공법 현장사례 분석 (Analysis of Construction Cases for Sequential PC Stairway Method)

  • 이석용;임홍철;김욱종;조홍덕;정미라
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.15-19
    • /
    • 2008
  • The use of Precast Concrete (PC) stairways is increasing to replace existing Reinforced Concrete (RC) stairways for the faster construction and the better quality control. Among several already developed PC stairway construction methods, RC Core Sequential Construction Method by Using PC Stairways (COSEC) has advantages of 1) allowing core of a building to be built prior to PC stairways so that two different procedures will not interfere with each other, and 2) having a newly developed joint connection with the core so that the RC core and PC stairways can be easily put together. In this paper, cases of several construction sites with the PC stairways method are analyzed. The elements of the developed method are described for further application and improvement.

  • PDF

Shear behaviour of RC T-beams strengthened with U-wrapped GFRP sheet

  • Panda, K.C.;Bhattacharyya, S.K.;Barai, S.V.
    • Steel and Composite Structures
    • /
    • 제12권2호
    • /
    • pp.149-166
    • /
    • 2012
  • This paper presents an experimental investigation on the performance of 2.5 m long reinforced concrete (RC) T-beams strengthened in shear using epoxy bonded glass fibre fabric. Eighteen (18) full scale, simply supported RC T-beams are tested. Nine beams are used as control beam specimens with three different stirrups spacing without glass fibre reinforced polymer (GFRP) sheet and rest nine beams are strengthened in shear with one, two, and three layers of GFRP sheet in the form of U-jacket around the web of T-beams for each type of stirrup spacing. The objective of this study is to evaluate the effectiveness, the cracking pattern and modes of failure of the GFRP strengthened RC T-beams. The test result indicates that for RC T-beams strengthened in shear with U-jacketed GFRP sheets, increase the load carrying capacity by 10-46%.

Analysis of behavior of bare and in-filled RC frames subjected to quasi static loading

  • Sandhu, Balvir;Sharma, Shruti;Kwatra, Naveen
    • Structural Engineering and Mechanics
    • /
    • 제73권4호
    • /
    • pp.381-395
    • /
    • 2020
  • Study on the inelastic response of bare and masonry infilled Reinforced Concrete (RC) frames repaired using Carbon Fibre Reinforced Polymers (CFRP) and Glass Fiber Reinforced Polymers (GFRP) subjected to quasi- static loading is presented in the work. The hysteresis behaviour, stiffness retention, energy dissipation and damage index are the parameters employed to analyze the efficacy of FRP strengthening of bare and brick in-filled RC frames. It is observed that there is a significant improvement in load carrying capacity of brick infilled frame over bare RC frame. Also FRP strengthened brick infilled frame performs much better than FRP repaired bare frame under quasi static loading. Repair and retrofitting of brick infilled RC frame shows an improved load carrying and damage tolerance capacity than control frame.

사물인터넷 환경에서 스마트 CCTV 방범 서비스 (Smart CCTV Security Service in IoT(Internet of Things) Environment)

  • 조정래;김희숙;채두걸;임숙자
    • 디지털콘텐츠학회 논문지
    • /
    • 제18권6호
    • /
    • pp.1135-1142
    • /
    • 2017
  • 본 논문에서는 사각지대의 범죄를 예방하고, 예측하지 못한 화재 또는 위험을 예방하기 위하여 IoT 기반의 스마트 CCTV 방범 서비스를 제안한다. 제안 방식에서는 라즈베리파이를 이용하여 RC(Radio Control)카를 만들고 RC카에 카메라 및 각종 모듈을 장착하였으며 방범 서비스 처리는 Raspbian O/S, Apach Web Server, Shell script, Python, PHP, HTML, CSS, Javascript를 사용하여 구현되었다. RC카는 영상, 음성 그리고 온도 등의 모듈로 현장의 위험을 판단하여 관리자에게 상황을 알려주는 방범 서비스를 제공한다. 실험 결과 영상과 음성 정보의 전달 시간이 0.1초 내에서 처리되었을 뿐 아니라 AVG, 위급 상황, 수동 모드에도 실시간 상태 전송이 가능하였다. 스마트시티 구현에 무인자동차, 드론 등에도 적용하여 제안 방식이 활용할 수 있을 것으로 기대한다.

스카이브릿지를 이용한 RC 주거용 건물의 진동제어 (Vibration Control of RC Residential Building Structure Using Sky-Bridge)

  • 안상경;오정근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.450-453
    • /
    • 2006
  • Coupling adjacent building with supplemental damping devices is a developing method of reduced structural response due to wind and seismic excitations. The philosophy is to allow structures, vibrating at different frequencies, to exert control forces upon one another to reduce the overall responses of the system. This paper studies the effect of installing vibration control devices of two high rise building structures(49 stories and 42 stories) connected by sky-bridge. According to the analysis results the use of sky-bridge can be effective in increasing damping ratio of the system.

  • PDF