• Title/Summary/Keyword: RC building

Search Result 733, Processing Time 0.02 seconds

Analysis of Vibration Characteristics Changes in a Single-Span Bridge Due to Temperature Using Continuous Measurement Data (상시 계측 데이터를 이용한 단경간 교량의 온도에 따른 진동 특성 변화 분석)

  • Tae-Ho Kwon;Byeong-Cheol Kim;Ki-Tae Park;Chi-Ho Jeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.5
    • /
    • pp.62-68
    • /
    • 2024
  • The Republic of Korea experiences four distinct seasons, with significant temperature differences between summer and winter, causing bridges to undergo large temperature variations throughout the year. When the temperature changes, the dynamic characteristics of bridge structures also change. However, during load-bearing capacity assessments in domestic bridge maintenance, this temperature effect is not considered, and only the natural frequency measured over a short period is used for evaluation. In this paper, we theoretically analyze the impact of changes in natural frequency on bridges and extract daily estimated natural frequency data from bridges with continuous vertical acceleration measurements taken over more than a year to confirm temperature-induced changes. The results show that a 1% decrease in natural frequency corresponds to an approximately 2% decrease in the load-bearing capacity of the bridge. Additionally, it was found from the measurement data that a 10℃ increase in temperature did not affect the natural frequency of RC slab bridges and Rahmen bridges, but in PSC-I girder bridges and steel box girder bridges, the natural frequency decreased by approximately 1.04% to 2.48%.

An Experimental Study on the Manufacture Ultra-High Strength Concrete of 1800kg/$\textrm{cm}^2$ Compressive Strength (Part I The Experimental Program and Preliminary Experiment) (압축강도 1800kg/$\textrm{cm}^2$의 초고강도콘크리트 개발에 관한 실험적 연구 (제1보 실험계획 및 예비실험))

  • 김규용;김진만;이상수;남상일;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.167-170
    • /
    • 1994
  • To reduce the size of structural members, high strength concrete has recently been utilized for structure such as ultra-high-rise buildings and prestressed concrete bridges in North America, and its compressive strength has gone up to 1300kg/$\textrm{cm}^2$. In Japan, research on high-strength concrete has been undertaken on a large scale by the national enterprise so-called New RC Project. And high-strength concrete with a design compressive strength over 450kg/$\textrm{cm}^2$ has recently been employed for high rised reinforced concrete building. As a result of the serious land availability situation of metropolitan areas in the world, buildings will become taller, and even higher strengths will be required. In the future, the utilization of high-strength concrete will spread widely through the development of new structural concepts, application of steels of a higher yield stress, silica fume, and other new materials. Considering these circumstance, the aim of this experimental study is to develop ultra-high-strength concrete with compressive strength over 1800kg/$\textrm{cm}^2$ with domestic current materials. There are so many factors which influence the manufacturing of ultra-high-strength concrete. The experimental factors selected in this study are mixing methods, curing methods, water-binder ratio, maximum size of coarse by silica fume. The results of this experimental study show that it is possible to develop the ultra-high-strength concrete with compressive strength over 1700kg/$\textrm{cm}^2$ at 28days, 1800kg/$\textrm{cm}^2$ at 56 days.

  • PDF

An Experimental Study on the Manufacture Ultra-High Strength Concrete of 1800kg/$\textrm{cm}^2$ Compressive Strength (Part 2 The Experiment on the Manufacture of the U.H.S Concrete) (압축강도 1800kg/$\textrm{cm}^2$의 초고강도콘크리트 개발에 관한 실험적 연구 (제2보 초고강도콘크리트의 제조에 관한 실험))

  • 남상일;김진만;최민수;김규용;최희용;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.171-174
    • /
    • 1994
  • To reduce the size of structural members, high strength concrete has recently been utilized for structure such as ultra-high-rise buildings and prestressed concrete bridges in North America, and its compressive strength has gone up to 1300kg/$\textrm{cm}^2$. In Japan, research on high-strength concrete has been undertaken on a large scale by the national enterprise so-called New RC Project. And high-strength concrete with a design compressive strength over 450kg/$\textrm{cm}^2$ has recently been employed for high rised reinforced concrete building. As a result of the serious land availability situation of metropolitan areas in the world, buildings will become taller, and even higher strengths will be required. In the future, the utilization of high-strength concrete will spread widely through the development of new structural concepts, application of steels of a higher yield stress, silica fume, and other new materials. Considering these circumstance, the aim of this experimental study is to develop ultra-high-strength concrete with compressive strength over 1800kg/$\textrm{cm}^2$ with domestic current materials. There are so many factors which influence the manufacturing of ultra-high-strength concrete. The experimental factors selected in this study are mixing methods, curing methods, water-binder ratio, maximum size of coarse by silica fume. The results of this experimental study show that it is possible to develop the ultra-high-strength concrete with compressive strength over 1700kg/$\textrm{cm}^2$ at 28days, 1800kg/$\textrm{cm}^2$ at 56 days.

  • PDF

Prevention of Human injury and Countermeasure of evacuation about Fire of Nursing Homes by Conversion of existing buildings - Focused on rural areas in Gwangju and Jeonnam - (기존 건축물을 용도변경한 노인의료복지시설의 화재 인명피해 예방과 피난 대책 -광주·전남 농촌지역을 중심으로-)

  • Kim, Hyun-Tae;Kim, Won-Jin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.27-36
    • /
    • 2018
  • At present, the elderly population in Korea is 14% of the total population and then We has entered an the society of advanced age. Along with this, elderly people with dementia and palsy are also increasing. The demand for elderly nursing homes for elderly people with severe diseases such as dementia and stroke is also increasing, and the existing buildings are being secured by Conversion of existing buildings. However, it is difficult to evacuate and fire due to the out of date of buildings by Conversion of existing buildings. For example, there is a fire in the Indukukwon, Pohang City and Hyosung Geriatric Hospital, Jangseong in Korea, which have changed the use of existing buildings. Many elderly people died in a night fire. It was because of the sandwich panel walls and PVC flooring material produced toxic gas instantly. In this study, we investigated the nursing home that changing the use and established fire prevention of human injury and countermeasure of evacuation. First, the sandwich panels which leading to deaths due to the toxic gas were installed in most nursing home. We recommend the RC, the masonry wall, and the glass fiber panel instead of the sandwich panels, In addition, the PVC flooring is most used in nursing home, the flooring material is considered such as the building stones, the tile, and the yellow soil closing instead of the PVC flooring. Second, we investigated the installation status of fire fighting equipment. As a result, the automatic-emergency open&shut equipment, the smoke ventilator and the evacuation slide were rarely installed. In order to secure the golden time in case of fire and to prevent the asphyxia caused by the toxic gas, the law should be amended to install the equipment.

Compressive behavior of galvanized steel wire mesh (GSWM) strengthened RC short column of varying shapes

  • Marthong, Comingstarful
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.3
    • /
    • pp.215-231
    • /
    • 2020
  • In a reinforced concrete building different shapes of column are adopted depending on the structural orientation and the architectural aspect. When there is an increase in loading due to changes in usage or revision in the design codes these columns need to be strengthened for enhanced performance during their service life. Strengthening materials such as carbon fiber and glass fiber polymer has been successfully used however, due to high cost application other alternative materials need to be explore. Galvanized steel wire mesh (GSWM) is one of the suitable materials locally available. High tensile strength, low weight, corrosion resistance, easy installation, minimum change in dimensions of the sections and cost effectives are the advantages of GSWM. Therefore, in this paper, four different shapes of column such as circular, square, rectangular and L were wrapped with different layers GSWM and jacketed with mortar. All the specimens were tested under axial compression. The objective of the study is to investigate the effectiveness of GSWM as a confining material for strengthening of column having varying shape. Test results shows that the axial strength enhanced with wrapping of GSWM jacket and a circular column presented the highest load carrying capacity and ductility as compared to the others. From the study of 22 column specimens, it is found that axial load is increased upto 20% and 19% when circular and square column are strengthened with one wrap of GSWM respectively, while a rectangular and L column required a wraps of two and three layers respectively in order to achieved the same load capacity as that of a circular column. Based on the present study, it is concluded that GSWM can be effectively used for strengthening of different shapes of concrete columns economically.

Seismic Evaluation of Low-rise RC Building in korea (국내 저층구조물의 내진성능평가)

  • Park, Jin Hwa;Ahn, Tea Sang;Seo, Hyun Sik;Kim, Sang Dea
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.29-29
    • /
    • 2011
  • 국내에서 기존건축물의 내진성능평가 기법이 연구되기 시작한지 20여 년간 다양한 평가방법이 제안되었다. 그러나, 제안된 평가방법은 미국이나 일본의 평가 방법을 도입 및 수정하는 내용이 주가 되어 국내실정에 맞지 않는 부분도 많이 발견되었다. 따라서 국내에서 제안된 기존 건축물의 내진성능 평가기법, 지진피해예측에 근거한 보강건축물의 합리적인 선정방법 및 이들 건축물에 적합한 내진보강방법 등의 연구는 아직까지 초보적인 단계라고 할 수 있다. 이에 본 연구의 목적은 이러한 평가 기법을 적용한 국내 저층구조물의 내진성능을 평가하는 것이다. 저층구조물의 내진성능을 평가하기 위하여 1988년 내진설계가 도입되기 이전에 건립된 4층 규모의 학교구조물을 해석대상 구조물로 선정하였다. 대상 해석구조물의 내진성능평가는 일본의 내진성능 평가법을 참고하여 평가절차가 다소 복잡한 부분을 국내 실정에 맞게 개선시킨 내진화 우선도 평가방법과 정밀한 내진성능을 평하는 방법으로 세계적으로 널리 사용되고 있는 ATC-40 성능평가방법에서 등가단자유 모델로 변환 과정에서 등가유효감쇠 및 등가유효주기 산정 관계식의 문제점을 개선한 FEMA-440의 선형화 성능평가방법(Linearization Method)을 사용하여 구조물의 성능을 평가하였다. 내진 성능 평가를 위해 현재 전 세계적으로 널리 사용되고 있는 구조물 비선형 전용 해석 프로그램인 Perform-3D를 이용하여 해석을 수행하였다. 본 연구를 통해 기존 저층구조물로 선정한 학교구조물에 대한 내진성능을 평가한 결과, 내진화 우선도 평가법 및 FEMA-440의 내진성능 평가는 유사한 경향의 결과를 나타내었고, 두 평가결과를 요약하면 Y방향은 보와 기둥에 끼인 조적벽체의 영향으로 별도의 내진성능이 향상 보강이 필요없으나, X방향은 창문하부 허리 조적벽 등의 영향으로 다소 취성적인 내진성능을 보유하고 있어 충분한 내진성능 확보를 위한 추가적인 보강이 필요한 것으로 판단된다.

  • PDF

Fuzzy methodology application for modeling uncertainties in chloride ingress models of RC building structure

  • Do, Jeongyun;Song, Hun;So, Seungyoung;Soh, Yangseob
    • Computers and Concrete
    • /
    • v.2 no.4
    • /
    • pp.325-343
    • /
    • 2005
  • Chloride ingress is a common cause of deterioration of reinforced concrete located in coastal zone. Modeling the chloride ingress is an important basis for designing reinforced concrete structures and for assessing the reliability of an existing structure. The modeling is also needed for predicting the deterioration of a reinforced structure. The existing deterministic solution for prediction model of corrosion initiation cannot reflect uncertainties which input variables have. This paper presents an approach to the fuzzy arithmetic based modeling of the chloride-induced corrosion of reinforcement in concrete structures that takes into account the uncertainties in the physical models of chloride penetration into concrete and corrosion of steel reinforcement, as well as the uncertainties in the governing parameters, including concrete diffusivity, concrete cover depth, surface chloride concentration and critical chloride level for corrosion initiation. There are a lot of prediction model for predicting the time of reinforcement corrosion of structures exposed to chloride-induced corrosion environment. In this work, RILEM model formula and Crank's solution of Fick's second law of diffusion is used. The parameters of the models are regarded as fuzzy numbers with proper membership function adapted to statistical data of the governing parameters instead of random variables of probabilistic modeling of Monte Carlo Simulation and the fuzziness of the time to corrosion initiation is determined by the fuzzy arithmetic of interval arithmetic and extension principle. An analysis is implemented by comparing deterministic calculation with fuzzy arithmetic for above two prediction models.

Non-linear analysis of side-plated RC beams considering longitudinal and transversal interlayer slips

  • Kolsek, Jerneja;Hozjan, Tomaz;Kroflic, Ales;Saje, Miran;Planinc, Igor
    • Steel and Composite Structures
    • /
    • v.16 no.6
    • /
    • pp.559-576
    • /
    • 2014
  • A new mathematical model and its finite element formulation for the non-linear stress-strain analysis of a planar beam strengthened with plates bolted or adhesively bonded to its lateral sides is presented. The connection between the layers is considered to be flexible in both the longitudinal and the transversal direction. The following assumptions are also adopted in the model: for each layer (i.e., the beam and the side plates) the geometrically linear and materially non-linear Bernoulli's beam theory is assumed, all of the layers are made of different homogeneous non-linear materials, the debonding of the beam from the side-plates due to, for example, a local buckling of the side plate, is prevented. The suitability of the theory is verified by the comparison of the present numerical results with experimental and numerical results from literature. The mechanical response arising from the theoretical model and its numerical formulation has been found realistic and the numerical model has been proven to be reliable and computationally effective. Finally, the present formulation is employed in the analysis of the effects of two different realizations of strengthening of a characteristic simply supported flexural beam (plates on the sides of the beam versus the tension-face plates). The analysis reveals that side plates efficiently enhance the bearing capacity of the flexural beam and can, in some cases, outperform the tensile-face plates in a lower loss of ductility, especially, if the connection between the beam and the side plates is sufficiently stiff.

Seismic Performance Evaluation of Medium-and Low-rise R/C Buildings Strengthened with RCSF External Connection Method by Pseudo Dynamic Test (유사동적실험에 의한 RCSF 외부접합공법으로 내진보강 된 중·저층 철근콘크리트 건물의 내진성능 평가)

  • Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.13-22
    • /
    • 2015
  • In this study, a new RCSF (Reinforced Concrete Steel Frame) external connection method is proposed for seismic strengthening of medium-and low-rise reinforced concrete buildings. The RCSF method, proposed in this study, is capable of carrying out the seismic retrofitting construction while residents can live inside structures. The method is one of the strength design approach by retrofit which can easily increase the ultimate lateral load capacity of concrete buildings controlled by shear. The pseudo-dynamic test, designed using a existing school building in Korea, was carried out in order to verify the seismic strengthening effects of the proposed method in terms of the maximum load carrying capacity and ductility. Test results revealed that the proposed RCSF strengthening method installed in RC frame enhanced conspicuously the strength and displacement capacities, and the method can resist markedly under the large scaled earthquake intensity level.

RC Flat Plate Subject to Combined In-Plane Compressive and Out-of-Plane Floor Loads (면내 압축력 및 면외 바닥하중을 받는 플랫 플레이트 슬래브)

  • Park, Hong-Gun
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.231-242
    • /
    • 1999
  • This paper presents a numerical study on the flat plates in deep basements, subjected to out-of-plane floor load and in-plane compressive load due to soil and hydraulic lateral pressure. For nonlinear finite element analysis, a computer program addressing material and geometric nonlinearities is developed. The validity of the numerical model is established by comparison with existing experiments performed on plates simply supported on four edges. The flat plates to be studied are designed according to the Direct Design Method in Korean Building Code for Structural Concrete. Through numerical study on the effects of different load combinations and loading sequence, the load condition that governs the strength of the flat plates is determined. For the plates under the governing load condition, parametric studies are performed to investigate variations of the strength with reinforcement ratio, aspect ratio, concrete strength, and slenderness ratio. Based on the numerical results, the floor load magnification factor is proposed.