• Title/Summary/Keyword: RC모델

Search Result 471, Processing Time 0.025 seconds

Analysis of Nonlinear Torsional Behavior for High Strength Reinforced Concrete Structure Using 3-Dimensional Lattice Model (3차원 래티스 모델을 사용한 고강도 철근콘크리트 구조물의 비선형 비틀림 해석)

  • Kwon, Min-Ho;Seo, Hyun-Su;Lim, Jeong-Hee;Kim, Jin-Sup
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • Because of earthquakes that have recently struck, seismic design criteria that considered performance of structure were included in the design concepts. Thus, a simple analysis tool is needed to predict the strength and ductility of RC structures. In this study, three-dimensional lattice model was developed to expand the two-dimensional lattice model. Torsional analysis of the structure was done to evaluate the developed three-dimensional lattice model. Lattice model was evaluated by comparing analytical results with experimental results. Lattice element size was evaluated using the results of analysis. Torsional analysis results, using three-dimensional lattice model, show that the results are relatively consistent with the experimental values.

Punching Shear Strength of RC Slabs by Simple Truss Model (단순 트러스 모델에 의한 철근콘크리트 교량 바닥판의 펀칭전단강도)

  • Lee, Yongwoo;Hwang, Hoonhee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.187-196
    • /
    • 2008
  • The punching shear strength of RC slabs is estimated analytically by the simple truss model. To avoid intrinsic difficulties in punching shear analysis of reinforced concrete slabs, the slabs were divided into three sub-structures as the punching cone and the remaining parts. The strength of the punching cone was evaluated by the stiffness of inclined strut. The stiffness of springs which control lateral displacement of the roller supports consists of the steel reinforcement which passed through the punching cone. Initial angle of struts was determined by curve fitting method of the experimental data with variable reinforcement ratio in order to compensate for uncertainties in the slab's punching shear, the simplification errors and the stiffness of the remaining sub-structures. The validity of computed punching shear strength by simple truss model was shown by comparing with experimental results. The punching shear strength, which was determined by snap-through critical load of shallow truss, can be used effectively to examine punching shear strength of RC slabs.

Shear Analysis of RC Structure using Evolutionary Structural Optimization (점진적 구조 최적화 기법을 이용한 철근 콘크리트 구조물의 전단 해석)

  • Kwak, Hyo-Gyoung;Yang, Kyu-Young;Shin, Dong-Kyu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.319-328
    • /
    • 2011
  • This paper introduces the construction of Strut-Tie model based on the Evolutionary Structural Optimization(ESO) method. Differently from conventional ESO method which uses plane stress elements, the introduced approach adopts the use of truss elements with the fact that the optimum topology of structures by ESO method is open a truss-like structure. Several examples are provided to demonstrate the capability of the proposed method in finding the best Strut-Tie models. In advance, it is shown that the introduced method is supported through the correlation studies between two-dimensional plane stress analysis and Strut-Tie models, and can be used effectively in practice, especially in shear design of complex reinforced concrete members where no previous experience is available.

Simple Modeling of Floor Heating Systems based on Optimal Parameter Settings (최적 파라미터를 이용한 단순 모델 기반 바닥 난방 시스템 모델링)

  • Park, Seung Hoon;Jang, Yong Sung;Kim, Eui-Jong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.472-481
    • /
    • 2017
  • Radiant floor heating systems have been used as common heating supply systems in most residential buildings in Korea. Since the system uses a floor as thermal storage, proper control strategy should be adopted to avoid over-or under-heating problems. So far, studies related to control of the floor heating system have been conducted based on computer simulations. The active layer in TRNSYS is known for its usability as a floor heating system model and is integrated with the TRNSYS building model (Type 56). However, floor heating system simulations with the active layer are operated only if pre-defined minimum mass flow rate is ensured. This study proposes a simple RC (Resistance-Capacitance) model for radiant floor heating systems. Model parameters such as Rs and Cs are defined by optimization. The active layer, in this study, is used as the target system to search for optimal values. A TRNOPT optimization tool was used to conduct optimization under given simulation conditions. The RC model with optimal parameters are tested in other mass flow rates that were not used during optimization. Results reveal the RC model describes the active layer with successfully optimized model parameters. The RC model has fewer model limitations, and is expected to be used for various target systems, e.g. experimental data of a real radiant heating system.

Shear Strength of Retrofitted RC Squat Wall by Additional Boundary Element (단부 증타 보강된 RC 전단벽체의 전단강도)

  • Yi, You-Sun;Hong, Sung-Gul;Park, Young-Mi
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.5
    • /
    • pp.489-499
    • /
    • 2015
  • This study suggested shear strength prediction model for retrofitted single-layered RC squat wall by providing column element as additional boundary element. This model revised existing shear strength prediction model of shear wall to consider detail and shear deformation capacity of column by assuming the length that concentrated shear deformation of the column is occurred. It was able to suggest additional compatibility condition related to shear strain of retrofitted of retrofitted shear wall at the ultimate state by using this length. Therefore, this study proposed a flow chart for predicting shear strength of the retrofitted shear wall considering this additional condition. Moreover, this study also proposed a method for predicting initial stiffness of the retrofitted shear wall by transforming the wall's resisting mechanism against to lateral load to a single diagonal strut mechanism. The proposed methods can predict shear strength and initial stiffness of not only the retrofitted shear wall of this study, also infilled RC shear wall in RC frame.

Effects of Unripe Rubus coreanus Miquel Extract on Improvement of Lipid Metabolism in C57BL/6 Mice Fed a High-Cholesterol Diet (미숙과 복분자 열매 추출물이 고콜레스테롤 식이를 섭취시킨 C57BL/6 Mice의 지질대사 개선 효과)

  • Jung, Myung-A;Cho, Sook-Hyun;Lee, Sun Young;Kim, Ji Hye;Oh, Kyonyeo;Kim, Young-Suk;Yoo, GooSang;Lee, Dong-Wook;Kim, Sunoh
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.5
    • /
    • pp.650-655
    • /
    • 2014
  • Hypercholesterolemia is the presence of high levels of cholesterol in the blood, and it is regarded as a risk factor for cardiovascular disease due to the effects of cholesterol. The objective of this study was to investigate the effects of unripe Rubus coreanus Miquel (uRC) extract on lipid metabolism in hypercholesterolemic mice fed a high cholesterol diet (HC). uRC 50 (unripe R. coreanus 5% ethanol extract 50 mg/kg/day), uRC 100 (unripe R. coreanus 5% ethanol extract 100 mg/kg/day), uRC 300 (unripe R. coreanus 5% ethanol extract 300 mg/kg/day), and BO (borage seed oil containing minimum of 20% ${\gamma}$-linolenic acid 30 mg/kg/day) were orally administered for 60 days after HC. Oral administration of uRC 50, uRC 100, uRC 300, and BO significantly reduced serum total-cholesterol, triglyceride, LDL-cholesterol, glutamic oxaloacetic transaminase, glutamic pyruvic transaminase, atherogenic index, and cardiac risk factor levels. Similarly, uRC treatment elevated serum HDL-cholesterol levels. These results suggest that unripe R. coreanus extract could be established as a functional food for the improvement of lipid metabolism.

Study on the Nonlinear Analysis Model for Seismic Performance Evaluation of School Buildings Retrofitted with Infilled Steel Frame with Brace (철골 끼움가새골조로 보강된 학교건물의 내진성능평가를 위한 비선형 해석 모델에 관한 연구)

  • Yoo, Suk-Hyeong;Ko, Kwan-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.65-72
    • /
    • 2022
  • Recently, damage to buildings due to earthquakes in Korea occurred mainly in school buildings and Piloti-type multi-family houses, highlighting the need for seismic retrofit for buildings of the same type. In the early days of the seismic retrofit project for school facilities, various patented methods using dampers as a ductile seismic retrofit method were applied without sufficient verification procedures. However, in 「School Facility Seismic Performance Evaluation and Retrofit Manual, 2021」, when the patented method is applied, it must be applied through a separate strict verification procedure, and instead, the strength/stiffness retrofit method was induced as a general method. In practice,when evaluating seismic performance for retrofit by infilled steel frame with brace, the analysis model is constructed by directly connecting only the steel brace to the existing RC member. However, if the frame is removed from the analysis model of the infilled steel frame with brace, the force reduction occurring on the existing RC member near the retrofit is considered to be very large, and this is judged to affect the review of whether to retrofit the foundation or not. Therefore, in this study, preliminary analysis with variables such as whether or not steel frame is taken into account and frame link method for the analysis model of RC school building retrofitted by infilled steel frame with brace and nonlinear analysis for actual 3-story school building was performed, and basic data for rational analysis model setting were presented by comparing preliminary analysis and pushover analysis results for each variable.

Truss Models for Deformation Analyses of RC Members (트러스 모델을 이용한 RC 부재의 변형 해석)

  • 홍성걸;이수곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.201-206
    • /
    • 2001
  • This paper presents truss model that can be used to determine the deformation as well as strength of RC members. This model is constituted to address plastic hinge rotation at tile deformation concentrated regions under severe lateral load. The behavior of each element of truss model is evaluated on the basis of stress field analysis. The deformation is obtained by combining element deformations with joint rotation. Initial strength is calculated at the first failure of any element, and strength deterioration after failure depends on the strength reduction of this element. The proposed model will provide useful tools in seismic design of ductility-required members.

  • PDF

Hysterisis Rules of RC member by Shaking Table Test (진동대 실험에 의한 RC부재의 이력거동)

  • Lee, Dae-Hyoung;Yang, Dong-Wook;Baek, Min-Chul;Hong, Hyun-Ki;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.9-10
    • /
    • 2009
  • The object of this research is to investigate the hysteresis rules of RC members by shaking table test. These hysteresis rules are essential to verify of safety under earthquake excitation. The effect of mass was investigated in stiffness of hysteresis rules.

  • PDF

Behavior Analysis of Eccentrically Loaded Restrained Reinforced Concrete Slender Columns (편심축하중을 받는 구속 RC장주의 거동 해석)

  • Park, Jai Oun;Choung, Kyoung Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.11-24
    • /
    • 1990
  • The effect of end restraints for adjoining members is the different variables influencing the column ultimate strength and the behavior. The propose of this study is to analyze eccentrically loaded reinforced concrete columns with the end restraind effect having rectangular cross-section and general boundary conditions. Accordingly, this investigation are to construct a typical analytical model of the reinforced concrete columns with general end boundary conditions. The mechanical components of the analytical model are to be rationally defined the actual behavior as possible, and the different variables influencing the behavior and the ultimate strength of the reinforced concrete columns are investigated by using a parametric study.

  • PDF