• Title/Summary/Keyword: RAID configuration

Search Result 14, Processing Time 0.026 seconds

Design and Implementation of a Video-On-Demand System using Software RAID Technology (소프트웨어 RAID 기술을 이용한 주문형 비디오 시스템의 설계 및 구현)

  • Kim, Jong-Hoon
    • Journal of The Korean Association of Information Education
    • /
    • v.3 no.1
    • /
    • pp.22-32
    • /
    • 1999
  • In this paper, a von system which is based on current computer technologies is implemented. This von system organizes many personal computers in a local network into a configuration server, storage servers, and clients. To provide reliability, the data is stored using software RAID technology. Also, multimedia services are client-based for efficiency. The software components of this von system are the von configuration software, the von configuration service software, the von management software, and the von service software. Only the von service software runs in the client, while all the others run in the configuration server. The operating system on which the configuration server is run is the Windows NT such that the software executes like the UNIX-daemon process in the Windows NT service manager.

  • PDF

Design and Implementation of RAID Controller using Serial ATA Interface (Serial ATA Interface를 통한 RAID Controller 보드의 설계 및 구현)

  • Lim, Seung-Ho;Lee, Ju-Pyung;Park, Kyu-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.665-668
    • /
    • 2003
  • In this paper, we have designed and implemented the RAID controller board which connects to the host computer with serial ATA interface and connects to the disks with parallel ATA interface. Serial ATA interface is proposed to overcome the design limitation of parallel ATA while enabling the storage interface to scale with the slowing media rate demands for PC platforms. Serial ATA is to replace parallel ATA with the compatibility with existing operating systems and drivers, adding performance headroom for years to come. It Moreover, serial ATA provides even faster transfer rate of 150 Mbytes/s which is larger than that of current parallel ATA. The RAID controller board designed in this paper combines up to 4 disks with parallel ATA interface, and connects to PC host computer with serial ATA interface. We have implemented RAID controller using Verilog HDL language with FPGA chip. The RAID controller supports RAID level 0 and 1 functionality. Experimently, the average read/write performance of parallel ATA interface is about 30 Mbytes/s. Therefore, when 4 parallel disks is connected to the RAID controller board, we can get almost full throughput of serial ATA protocol using the RAID level 0 configuration with 4 disks.

  • PDF

A Safety IO Throttling Method Inducting Differential End of Life to Improving the Reliability of Big Data Maintenance in the SSD based RAID (SSD기반 RAID 시스템에서 빅데이터 유지 보수의 신뢰성을 향상시키기 위한 차등 수명 마감을 유도하는 안전한 IO 조절 기법)

  • Lee, Hyun-Seob
    • Journal of Digital Convergence
    • /
    • v.20 no.5
    • /
    • pp.593-598
    • /
    • 2022
  • Recently, data production has seen explosive growth, and the storage systems to store these big data safely and quickly is evolving in various ways. A typical configuration of storage systems is the use of SSDs with fast data processing speed as a RAID group that can maintain reliable data. However, since NAND flash memory, which composes SSD, has the feature that deterioration if writes more than a certain number of times are repeated, can increase the likelihood of simultaneous failure on multiple SSDs in a RAID group. And this can result in serious reliability problems that data cannot be recovered. Thus, in order to solve this problem, we propose a method of throttling IOs so that each SSD within a RAID group leads to a different life-end. The technique proposed in this paper utilizes SMART to control the state of each SSD and the number of IOs allocated according to the data pattern used step by step. In addition, this method has the advantage of preventing large amounts of concurrency defects in RAID because it induces differential lifetime finishes of SSDs.

Cache Management using a Adaptive Parity Group Configuration in RAID 5 Controller (적응형 패리티 그룹 구성을 이용한 RAID 5 제어기에서의 캐시 운영)

  • Huh, Jung-Ho;Song, Ja-Young;Chang, Tae-Mu
    • The KIPS Transactions:PartA
    • /
    • v.10A no.2
    • /
    • pp.83-92
    • /
    • 2003
  • RAID 5 is a widely-used technique used to construct disk systems of high reliability and performance. This paper proposes APGOC (Adaptive Parity Group On Cache) organization on cache to solve "small write" problem of RAID 5 especially in OLTP (On-Line Transaction Processing System) environments. In our approach, when user process makes a request for a file to kernel, the information on the read/write characteristics is added to the file data structure of the file system. With this information, data and parity cache can be managed interchangeably through parity fetching. Therefore we can enhance the cache utilization and improve the disk request response time. Our method is analyzed and evaluated with a simulation method. Comparing with previous works, we observed about 6~l3% of performance enhancement.hancement.

A study on the Construction of Remote Status Display Software for Soft-RAID system of Linux based Server (리눅스 기반 서버의 소프트-RAID 시스템용 원격 상태 표시 소프트웨어의 구성에 관한 연구)

  • Na, Won-Shik;Lee, Hyun-Chang
    • Journal of Software Assessment and Valuation
    • /
    • v.15 no.1
    • /
    • pp.97-102
    • /
    • 2019
  • In this paper, we propose a method to remotely intuitively identify faults found in storage devices in soft-RAID used in a server system composed of Linux. To do this, we analyze the principle and problem of fault reporting method in the soft-RAID system of Linux OS and suggest the state of storage devices in remote Internet Home-page. The proposed method consists of a method of displaying images on the Internet home-page, so that it can be arranged freely when creating a home-page, and the image data is composed of external files, so it is bery convenient to edit and replace images In order to verify the effectiveness of the proposed method, we have confirmed that the state of each storage device can be confirmed at a long distance without any major addition to the Home-page configuration.

A Study on Optimized RAID Disk Configuration for Medical Information Systems (의료정보시스템에서 최적화된 RAID 디스크 구성에 대한 연구)

  • Kang, Byung Ik;Park, Jun Pyo;Chung, Yon Dohn
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.104-107
    • /
    • 2011
  • 의료정보시스템에서 처리하는 데이터 크기가 급속하게 늘어남에 따라 대용량 데이터 처리에 대한 필요성이 갈수록 증가되고 있다. 최근 몇 년 동안 의료정보시스템을 구성하는 요소 중 디스크의 성능 향상 및 발전 속도가 중앙처리장치에 비해 둔화되고 있으며, 이와 같은 성능차이로 인해 디스크 장치가 시스템의 병목지역이 되어 전체 성능을 저하시키는 주된 요인이 되고 있다. 의료정보시스템은 주로 관계형 데이터베이스를 이용하여 저장하기 때문에 서버의 데이터 접근 처리방식과 I/O에 대한 부분이 성능을 크게 좌우한다. 따라서 본 논문에서는 의료정보시스템의 특성에 따른 하드웨어 RAID 디스크 구성 최적화 방안을 알아봄으로써 본 논문의 연구 결과가 시스템 구성 초기에 최적화된 I/O 를 위한 구성정보로 활용될 수 있도록 하고자 한다.

A Study on Comparison of Massive Data Recording Equipments for VLBI Radio Observation Data (VLBI 전파 관측데이터를 위한 대용량 기록장치 비교에 관한 연구)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Dong-Kyu;Hwang, Ju-Yeon;Oh, Chungsik;Kim, Hyo-Ryoung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.125-132
    • /
    • 2018
  • KVN(Korean VLBI Network) introduced the Mark6 system of the MIT haystack observatory as a recorder for data recording up to 32 Gbps for VLBI(Very Long Baseline Interferometry) observation. The Mark6 recorder can record data at up to 32Gbps when two systems and 64 HDDs are installed. However, because of the unique recording method that is characteristic of Mark6, we are introducing a large amount of data into a virtual file system, or using a general RAID method, which causes data loss when reading and transferring files at the highest recording speed or file system have. The Flexbuff system, a software recorder developed by JIVE(Joint Institute for VLBI ERIC), can be configured to operate as a data recorder through RAID configuration and network upgrades. In particular, when installed in the Mark6 system, it can record VLBI data at a maximum speed of 32 Gbps with less loss of data compared to the existing Mark6 by utilizing Mark6 resources well. In this paper, we propose that the existing Mark6 system can be operated as Mark6-Flexbuff by installing jive5ab software, and it is verified through experiment that it can be effectively used for VLBI observation operation through data recording test.

A Study on the Design Analysis and Test of a Ballute Type Parachute of the Smart Submunition (지능형 자탄의 벌루트형 낙하산 설계 해석 및 시험에 관한 연구)

  • Lee, Sang-Kil;Lee, Sang-Seung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.23-31
    • /
    • 2008
  • The configuration model of a ballute type RAID(Ram Air Inflated Decelerator) for reducing the high speed and high revolution of smart submuntion is designed and tested. Three dimensional incompressible turbulent flow computational fluid dynamic analysis for the assembly of ballute and submunition is performed and pressure distribution, velocity, and drag around the assembly is calculated. Aerodynamic characteristics of the ballute assembly such as air flow inside and outside of the ballute and pressure distribution is clearly shown and it's drag coefficient is computed. Trajectory analysis of the submunition is performed and is in good agreement with the descending trajectory data of experimental model tested.

Design on Smart Security Disk System with Wireless Interface of High Definition Image (고해상도 영상의 무선 인터페이스를 갖는 스마트 보안 디스크 시스템의 설계)

  • Kim, Won
    • Journal of Digital Convergence
    • /
    • v.11 no.9
    • /
    • pp.195-200
    • /
    • 2013
  • In visual surveillance system abandoned objects in public places are the deliberately left things, which should be automatically detected by intelligent systems in the environment where the number of cameras is increasing. This research deals with the design scheme of a smart security disk system which can detect these abandoned objects automatically and save the relevant image information with the wireless interface of high definition images. By implementing the proposed system in this research it is confirmed that the transmission performance shows 60 frames per second without compression of high definition images and the capability of the disk system shows the relevant images can be saved in a RAID configuration. Also, the proposed visual surveillance software shows a good detection rate of 80% in PAT performance.

The Configuration of Total Distribution Automatic System (종합배전자동화 시스템의 구성)

  • Jeong Mi Ae;Ha Bok Nam;Seol Leel Ho;Kang Moon Ho;Lee Heung Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.572-574
    • /
    • 2004
  • The configuration of Distribution Automatic System(BAS) is dual servers and raid 5(redundant arrays of inexpensive disks) clustering dual HDD. The DAS has the distributed object-oriented architecture using middleware software(BASEstar), so the number of client nodes has no limitation. Because the DAS is scalable, it can be configured using various application programs and be upgraded easily. The DAS has competitive to export because there are system development and accumulation of technology that coincide in International Standard, using common 05 and DB. This paper describes the structure of DAS hardware and software separately and proposes to improve program to share real time DB efficiently at each node.

  • PDF