• Title/Summary/Keyword: RAD18

Search Result 59, Processing Time 0.024 seconds

Postoperative Evaluation of Congenital Atrial Septal Defect in Adult (성인 심방중격결손증의 술후평가)

  • Kim, Ae-Jung;Jo, Jung-Gu;Gu, Ja-Hong;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.386-392
    • /
    • 1996
  • Preoperative and postoperative evaluation was done in 60 adult patients above 20 years of age among 152 patients, who had operation for the congenital atrial septal defect from January 1984 to June 1993 in the Department of Thoracic and Cardiovascular Surgery, Chonbuk National University Hospital. Anatomically, the secundum type defect was present In 58 cases and the other two were ostium primum type defect. The defect were closed directly in 45 cases and with patches in 15 cases. Preopera ive EKG findings revealed regular sinus rhythm in 81%, arrhythmia 19%, RVH 32%, RAD 30%, Postoperative findings were regular sinus rhythm in 76%, arrhythmia 24%, RVH 25%. RAD 25%. In hemodynamic data, the mean SPAP in patients over 40 years old was 41.91 $\pm$ 14.33mmHg compared to 31.46 $\pm$ 13.77 mmHg in patients under 40 years old, and the difference between the two groups was stastistically significant. And then the patients were classified into two groups (group A sinus group, and group B : arrhythmia group) according to their preoperative rhythm. The patients in group B were older, had greater value of mean SPAP and Rp/Rs. Mean Qp/qs was higher in group A. But the difference between two groups about the mean Qp/qs and Rp/Rs was not significant. Postoperative complications such as arrhythmia, pneumothorax or hemothorax occurred in 7 cases, but there was no operative mortality. The functional improvement were remarkable in half of the patients who underwent surgery.

  • PDF

Power Generating Performance of Photovoltaic Power System for Greenhouse Equipment Operation (온실설비 작동용 태양광발전시스템의 발전 성능 분석)

  • Yoon, Yong-Cheol;Bae, Yong-Han;Ryou, Young-Sun;Lee, Sung-Hyoun;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2009
  • For the purpose of reducing the cost for greenhouse operation by acquiring the electric power necessary for it, this study installed a solar photovoltaic system on the roof of the building adjacent to green-houses and experimentally examined the quantity of power generation based on weather conditions. The results of the study are as per the below: The maximum, average and minimum temperature while the experiment was conducted was $0.4{\sim}34.1,\;-6.1{\sim}22.2$, and $-14.1{\sim}16.7^{\circ}C$ respectively, and the solar radiation was $28.8MJ{\cdot}m^{-2}$ (maximum), $14.9MJ{\cdot}m^{-2}$ (average), and $0.6MJ{\cdot}m^{-2}$ (minimum). The quantity of electric power didn't increase in proportion to the quantity of solar radiation and instead, it was almost consistent around 750W. Daily maximum, average and minimum consumption of electric power was 5.2kWh, 2.5kWh and 0kWh respectively. Based on the average electric power consumption of the system used for this experiment, it was sufficient in case the capacity and the working time of a hot blast heater are small, but it was short in case they are big. In case the capacity of the hot blast heater is big, the average electric power quantity will be sufficient for array area $21m^2$, about three times of the present area. In summer when the temperature of the array becomes high, the generation of electric power didn't increase in proportion to the quantity of solar radiation, but this experiment result shows a high correlation between two factors (coefficient of correlation 0.84).

The Effect of 131I Therapy by Taking in Laxatives (방사성요오드 치료 시 완하제 투여 효과)

  • Kil, Sang-Hyeong;LEE, Hyo-Yeong;Park, Kwang-Yeol;Jo, Kyung-Nam;Baek, Seung-Jo;Hwang, Kyo-Min;Cho, Seong-Mook;Choi, Jae-Hyeok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2014
  • Purpose: Our goals were to evaluate the effect of high dose radioiodine treatment for thyroid cancer by taking in laxatives. Materials and Methods: Twenty patients(M:F=13:7, age $46.3{\pm}8.1\;yrs$) who underwent high dose radioiodine treatment were seperated into Group 1 taking $^{131}I$ 5,500 MBq and Group 2 with the use of laxatives after taking $^{131}I$ 5,500 MBq. The whole body was scanned 16 hours and 40 hours after taking radioactive iodines by using gamma camera, the ROIs were drawn on the gastro-intestinal tract and thigh for calculation of reduction ratio. At particular time during hospitalization, the radioactivity remaining in the body was measured in 1 meter from patient by using survey meter (RadEye-G10, Thermo Fisher Scientific, USA). Schematic presentation of an Origin 8.5.1 software was used for spatial dose rate. Statistical comparison between groups were done using independent samples t-test. P value less than 0.05 was regarded as statistically significant. Results: The reduction ratio in gastro-intestinal 16 hours and 40 hours after taking laxatives is $42.1{\pm}6.3%$ in Group 1 and $72.1{\pm}6.4%$ in Group 2. The spatial dose rate measured when discharging from hospital was $23.8{\pm}6.7{\mu}Sv/h$ in Group 1 and $8.2{\pm}2.4{\mu}Sv/h$ in Group 2. The radioactivity remaining in the body is much decreased at the patient with laxatives(P<0.05). Conclusion: The use in combination with laxatives is helpful for decreasing radioactivity remaining in the body. The radioactive contamination could be decreased at marginal individuals from patients.

  • PDF

Treatment of Unresectale Non-Small-Cell Lung Cancer with Curative Radiotherapy (비소세포성폐암의 방사선치료 성적)

  • Kim Il Han;Ha Sung Whan;Park Charn Il;Shim Young Soo;Kim Noe Kyeong;Kim Keun Youl;Han Yong Chol
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.203-211
    • /
    • 1984
  • From 1979 to 1982, 80 patients with unresectable non-small-cell lung cancer without metastasis were treated with high-dose radiotherapy to the primary and to regional lymph nodes with or without supraclavicular lymphatics in the Department of Therapeutic Radiology, Seoul National University Hospital. Of these, 56 patients$(70\%)$ were completely evaluable, and 59 patients$(74\%)$ had squamous cell carcinoma, 13a large cell undifferentiated carcinoma and 831 adenocarcinoma. 21 patients$(26\%)$ had Stage II and 59 patients$(74\%)$ had Stage III. The complete and partial response rate in the high-dose$(\approx\;6,000\;rad)$ radiotherapy was $70\%\;with\;19\%$ complete response. 69 patients$(86\%)$ failed in the treatment, by the failure pattern, $64\%$ had local failure alone, $35\%$ had local failure and distant metastasis and $1\%$ had distant metastasis alone. The failure rate in the thorax were $76\%$ in squamous cell carcinoma, $40\%$in adenocarcinoma and $20\%$ in large cell undifferentiated carcinoma Preliminary result shows that actuarial survival at 1, 2 and 3 years were $56\%,\;26\%\;and\;20\%$ in overall patients and $64\%,\;37\%\;and\;21\%\;in\;Stage\;II\;and\;54\%1,\;21\%\;and\;18\%$ in Stage III, respectively. Overall median survival was 14 months; 17 months in Stage II and 13 months in Stage m. 8 patients$(10\%)$ have lived a minimum of 2 years with no evidence of disease. There was no fatal complication confirmed to be induced by radiotherapy, so definitive high-dose radiotherapy was tolerated well without major problems and resulted in good local control and survival.

  • PDF

Study on Waxy Corn IX. Amylogram Properties, Antioxidant Activity and Texture Analysis on the Developed Waxy Corn Hybrids (찰옥수수 연구 IX. 찰옥수수 교잡종의 아밀로그램 특성, 항산화성 및 식미관련 종실의 물성)

  • Bok, Tae-Gyu;Lee, Moon-Sub;Choi, Yun-Pyo;Cha, Hui-Jung;Baek, Seoung-U;Jo, Yang-Hee;Lee, Hee-Bong
    • Korean Journal of Breeding Science
    • /
    • v.43 no.1
    • /
    • pp.62-67
    • /
    • 2011
  • This study was carried out to gain basic informations about amylogram, antioxidant activity function and physicochemical properties for kernel of the newly developed waxy corn hybrids. The used materials were produced in 2008 and cultivated at breeding farm of CNU in 2009. From amylogram analysis, peak and minimum viscosity of the used hybrids were appeared in CNU08H-71 and CNU08H-69 hybrid, respectively. DPPH free radical scavenging effect marked as election donating ability was highly appeared in CNU08H-15 and CNU08H-69 hybrid, while CNU08H-h102 hybrid was the lowest. Hardness of kernel was highly appeared in CNU08H-35 hybrid, and chewiness and gumminess were also the highest in this hybrid, but those of CNU08H-h105 hybrid were the lowest. In these facts, we confirmed that the used hybrids were very different among traits related to amylogram, functions and table qualities. Accordingly, development of the new waxy corn hybrid will be profitable to select and develop as a crossing combination including many excellent traits.

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.

The Usability Evaluation of the Usefulness of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon;Nam, Kun-Sik;Lyu, Kwang-Yeul;Lee, Tae Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we identify the quality of the image and the impact on the Standard Uptake Value (SUV). In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mm Pb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference when gab is decrease and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep organs should be a priority rather than superficial organ disease. Use of bismuth shielding factor considering the standard clinical examination, decrease unnecessary exposure can be expected to be considered.

The Usability Evaluation According to the Application of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Nam-Kung, Sik;Kim, Ji Hyeon;Lee, Ju young;Park, Hoon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.36-42
    • /
    • 2013
  • Purpose: Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we want to identify the quality of the image and the impact on the SUV. Materials and Methods: In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mmPb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. Results: When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Conclusion: Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose be considered. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference is more decreased as gab of shields and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep or other organs should be a priority rather than superficial disease. Through this study, when applying identified to clinical examination, the reduction of unnecessary exposure is considered.

  • PDF

Effect of Tumor Hypoxia on Efficacy of Tirapazamine Combined with Fractionated Irradiation in Mouse Tumor (마우스종양에서 분할방사선조사와 병용된 Tirapazamine의 효과에 미치는 종양 저산소상태의 영향)

  • Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.120-126
    • /
    • 2000
  • Purpose : Tumor hypoxia can be overcome with hypoxic cytotoxin. In mouse tumor, tirapazamine's efficacy of the potentiating radiation effect was tested by the tumor oxygenation status combined with hype facti on ated rad iotherapy .:The control and hypoxic mouse tumors we established by inoculation of RIF-1 tumor cells into the normal or previously irradiated back and thigh of C3H mice. When the tumors reached a proper size, both the control and hypoxic tumors were given hypefractionated treatments (8fractions/4 days) with saline (0.02 ml/g), tirapazamin (0.08 mM/0.02 ml/kg), irradiation (2.5 Gy), irradiation combined with tirapazamine given 30 minutes prior to each irradiation. The response was evaluated by the growth delay assay by measuring tumor size from day 0 (12 hrs prior to the first fractionation) to the day when the volume had 4-fold increase or cross sectional area had 2-fold increase. Results : Overall growth pattern showed that tirapazamine Potentiated radiation effect in back and thigh tumors grew in the normal and preirradiated tumor bed. With growth delay assay using reference point of initial tumor volume or cross sectional area, tirapazamine potentiated radiation effect 1.9 times for the control and 2.4 times for the hypoxic tumors in back, and 1.85 times for the control and 1.6 times for the hypoxic tumors. With reference of 4-fold increase of the initial volume or 2-fold increase of the cross sectional area, tirapazamine potentiated radiation effect 1.48 times for the control and 2.02 times for the hypxic tumors in back, and 1.85 times for the control and 1.6 times for the hypoxic tumors. Conclusions : Present result indicated that radiation response of hypoxic tumors was potentiated by tirapazamine in the back or thigh tumors grew in the control or preirradiated tumor bed, and potentiation of the hypoxic tumors was eDual to or greater than that of the control tumors in the back or thigh.

  • PDF