• Title/Summary/Keyword: RACK1

Search Result 284, Processing Time 0.027 seconds

Seismic Qualification of Class 1E Battery by Combined Analysis and Testing (수치해석과 실험을 통한 안전등급 축전지의 내진검증)

  • 김영중;박성환;정태영;정정훈
    • Journal of KSNVE
    • /
    • v.3 no.1
    • /
    • pp.39-46
    • /
    • 1993
  • The seismic qualification for the class 1E battery of Korea Multipurpose Research Reactor was accomplished by the analysis as well as testing. The full rack consists of 4 similar sections of typical frame structure and contains 60 cells. However, since the seismic qualification was required on the frame structure and only on 3 aged ones among 60 dells, 2 sections of the full rack were assembled as a test rack with 28 cells including the 3 aged cells for an economic test. Seismic analysis for the full rack was carried out using the finite element program ANSYS. The modal parameters identified from the resonance search thest on the test rack were used to the seismic analysis of the full rack. It was confirmed that the test rack could represent the full rack with regards to seismic responses and function of cells, and that the full rack and aged cells were qualified to the given seismic test requirements.

  • PDF

Effect of Rack Compartment using Barriers on Reducing the Fire Spread (차단막에 의한 랙크 구획화가 화재확산 저감에 미치는 영향)

  • Cho, Gyu-Hwan;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.66-75
    • /
    • 2018
  • A barrier installed within a rack plays a significant role in delaying the initial spread of fire but it can be an obstacle to a ceiling-type sprinkler installed for extinguishing fires and for supplying fire extinguishing water. An in-rack sprinkler and a barrier can be applied at the same time, but a study on a barrier's ability to delay fire spread or its effect on the in-rack sprinkler is needed. Accordingly, this study examined the effect of a barrier on the delay of fire spread and the in-rack sprinkler according to installation conditions through the reduced scale fire test. As a result, the delay in fire spread increased more than four times when a horizontal barrier and a vertical barrier were installed at the same time. The temperature was also increased two to three times with the compartment, resulting in the early operation of the in-rack sprinkler.

Behavioral Characteristics Investigation of Rack Structure Depending on Forklift Impact Scenarios and Storage Distributions (지게차 충돌 위치 및 보관물류 분포에 따른 선반구조물의 거동특성분석)

  • Ok, Seung-Yong;Kwon, Oh-Yong;Paik, Shin Won
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.6
    • /
    • pp.49-56
    • /
    • 2013
  • The statistics of recent accidents in warehouses show that a heavy toll of lives were produced by various accidents, e.g. collision, overturn, fall, slip, exposure to harmful substances or environments, etc. Of significant concern amongst them is the collision, especially the collision between forklift and storage rack structure. Accordingly, this study focuses on behavioral characteristics of rack structure subjected to dynamic impact loading of a forklift. For this purpose, time-domain response analysis has been performed on a standard 2-bay six-story rack structure consisting of columns, beams and bracing members with perforated open section. In order to investigate the most critical scenario, the impact loads are applied in both down-aisle and cross-aisle directions, and the impact locations are also varied along the shelves of the palettes. In order to deal with storage distributions, three types of rack structures are further taken into account: original empty rack structure with no storage, half-loaded rack structure and fully-loaded rack structure. The numerical simulation results demonstrate that the dynamic characteristics of the rack structure are significantly dependent on the distribution of the storage goods and its natural period varies from 0.24sec to 1.06sec, approximately 4.4 times. Further, the parametric studies show that the forklift impact is most critical to the safety of the rack structure when it collides either at the base or at the top of the rack structure.

Rack-Level DC Power Solution for Volume Servers

  • Kwon, Won-Ok;Seo, Hae-Moon;Choi, Pyung
    • ETRI Journal
    • /
    • v.32 no.6
    • /
    • pp.940-949
    • /
    • 2010
  • Rack-level DC power supply is the optimal technology for providing DC power to a volume server without any power infrastructure changes in an existing AC data center. In this paper, we propose a smartly controllable and monitorable DC rack power system. The proposed system improves power efficiency by changing the power distribution architecture of a conventional method in the rack. We developed an optimal power control method in multipower modules to provide high efficiency at low loads. In addition, the proposed system provides real-time web monitoring of the rack power and environment around a rack. In our experiments, the proposed system improved the power efficiency by over 10% compared to an AC power system providing N+1 redundant power and power monitoring.

Evaluation of Nutrients during Rack and Bag Culture or Suspended Culture of Pacific Oyster Crassostrea gigas (부유망식과 수하식 양성방법에 따른 참굴(Crassostrea gigas)의 영양상태)

  • Choi, Yong-Jun;Tri, Nguyen Thanh;Lee, Jeong-Mee;Kang, Seok-Joong;Choi, Byeong-Dae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.3
    • /
    • pp.263-269
    • /
    • 2017
  • The mineral contents, and free amino acid, and fatty acid composition of rack and bag or suspended cultured oysters Crassostrea gigas were compared. The moisture content did not change much from 82.8% to 86.3% in the different culture methods. The glycogen level was low 4.7% during rack and bag culture but high 7.2% during suspended culture. The sodium level was the highest during suspended culture, while copper and zinc level were highest during rack and bag culture. The taurine level was 1,385-1,375 mg/100 g in oyster cultured using the rack and bag method, but that in the market sample was lowest at 1,015.8 mg/100 g. Hydroxyproline, glutamic acid, proline, glycine, and alanine were detected at high levels in the experimental oysters. The polyunsaturated fatty acid content was similar among samples. The docosahexaenoic acid level was 14% with rack and bag culture and 12% with suspended culture, whereas the eicosapentaenoic acid level was 15% with rack and bag culture and 20% with suspended culture. The atherogenic index (AI), thrombogenicity index (TI), and hypocholesterolemic/ hypercholesterolemic (h/H) ratio were important factors in the nutritional evaluation. The AI and TI values were 0.5-0.2, and the h/H ratio were 2.0 and 2.4 with the rack and bag and suspended culture, respectively.

Study on Optimal Condition for Oyster Rack Culture in terms of tidal exposure and rack height in Wando Coast, Korea

  • Han, Hyon Sob;Cho, Sang-Man
    • The Korean Journal of Malacology
    • /
    • v.29 no.1
    • /
    • pp.43-50
    • /
    • 2013
  • We investigated the growth performance of oysters (initial shell height $57.5{\pm}8.5$ mm) under differing conditions of tidal exposure time and culture rack height in an experiment that commenced in April, 2011. Significant differences were observed in shell height from June 2011, in total weight from August, and in meat weight from September. Fatness tended to decrease during the experimental period, but was not significantly different at the end of the experiment. Significant differences in survival rates were mainly observed from June to August. After September, further changes were not observed in any experimental treatment group. The greatest growth potential ($L_{\infty}$) and survival rate were observed at a sea level of approximately 116 cm. The results indicate that in the study area the use of oyster culture conditions involving 1 or 2 h of tidal exposure and 60 - 70 cm rack height could result in oysters reaching the favored commercial half shell size within 14 months, with > 80% survival.

A Case Study on Construction Cost Comparison for On-Site Construction and Off-Site Construction of Plant Project (플랜트 건설의 현장시공 및 모듈시공에 대한 공사비 비교 사례연구 - Pipe Rack을 대상으로 공사비 산정 -)

  • Kang, Hyun Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.4
    • /
    • pp.25-34
    • /
    • 2023
  • The purpose of this study is to calculate and compare construction costs for On-Site Construction and Off-Site Construction in Plant Project. For this purpose, the target for calculating the construction cost was limited to the Pipe Rack(Steel Structure and Piping). The results derived according to the purpose of the study are as follows. 1)The direct construction cost for On-Site Pipe Rack construction was KRW 56 billion, with Steel Structure KRW 25.1 billion and Piping KRW 30.8 billion won. 2)Comparing the rate of change between On-Site Construction and Off-Site Construction, material costs increased by 1.9% and expenses by 192.1%, but labor costs decreased by -9.1%, resulting in a total direct construction cost increase of 8.4%. These results can be used as reference data to check the current status of the increase or decrease in construction costs when constructing Pipe Racks as Off-Site Construction.

Application of Horizontal Barrier on a Rack to Reduce Fire Spread (화재확산 저감을 위한 랙크 내 수평차단막 적용에 관한 연구)

  • Yeo, In-Hwan;Cho, Gyu-Hwan
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.71-79
    • /
    • 2017
  • A rack warehouse with a vertically loading type and high loading density has severe risks and damage during its fire. In this regard, US and Japan strive to minimize the fire spread by applying in-rack sprinkler, horizontal barriers, etc. corresponding to their own rack warehouse but there is no study and policy in Korea. Therefore, a model scale fire test was carried out targeting the standard rack incorporating the national rack warehouse in order to check fire characteristics in ignition points and installation distances of horizontal barriers in this study. As a result of the test, vertical fire spread of about 30% was inhibited by narrowing its installation distance from 2-layer to 1-layer in an ignition condition of the flue space. In addition, as a result of the measurement of the temperature in the upper and lower parts of the horizontal barrier, the temperature distribution showed about 2~4 higher in a condition with an installation of the barrier than that in the condition without the barrier. Consequently, it is likely that the horizontal barrier will help the initial operation of in-rack sprinkler.

The of Rack with Modularized Cell considering Heterogeneous Unit Load Size in AS/RS (자동창고 Effectiveness 시스템에서 크기가 다른 저장단위를 고려한 모듈화 셀을 갖는 랙의 효과)

  • 이문환;이영해
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2000.04a
    • /
    • pp.1-4
    • /
    • 2000
  • In general, under the concept of unit load, Automated Storage/Retrieval Systems (AS/RS) have the rack of equal sized cells. However, they are inadequate and inefficient meeting the various sizes of customers' demands in today's business environment. Higher utilization and flexibility of warehouse storage can be achieved by using AS/RS with tile rack of modularized cell. In this paper, the model of AS/RS with the rack of modularized cell is proposed, and the effectiveness of proposed model is presented by way of numerical examples. The model developed in this research, as one type of AS/RS that is more flexible to the size and has higher space utilization than those of existing rack structure, could every useful for the storage of heterogeneous unit load sizes.

  • PDF