• Title/Summary/Keyword: RA value

Search Result 675, Processing Time 0.034 seconds

Determination of $^{226}Ra$ Isotope in the Leachate around Phosphogypsum Stack Using Ethylenediaminetetraacetic Acid (EDTA) (Ethylenediaminetetraacetic acid (EDTA)를 이용한 인산석고 야적장 침출수 중의 $^{226}Ra$ 분석법 개발)

  • Kim, Geun-Ho;Kim, Yong-Jae;Chang, Byung-Uck
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.223-229
    • /
    • 2011
  • Ba is the most useful element to get the $Ba(Ra)SO_4$ precipitate. However, when the high concentrations of ions such as sulfate, calcium are existed in the leachate of phosphogypsum stack, it is difficult to get the $Ba(Ra)SO_4$ precipitate. Since this reason, the developed method for the Ba coprecipitate using EDTA was performed to determine the $^{226}Ra$ concentration in the high sulfate sample. The average concentration of $^{226}Ra$ in a leachate of phosphogypsum using this method was 0.102 $Bq{\cdot}kg^{-1}$ and the minimal detectable activity is 3.4 $mBq{\cdot}kg^{-1}$. The $mBq{\cdot}kg^{-1}$ method was 0.102 $Bq{\cdot}kg^{-1}$ and the minimal detectable activity is 3.4 $mBq{\cdot}kg^{-1}$. The $^{226}Ra$ stock solution and the CRM (Certified Reference Material) were analyzed to verify this method. In analyzed $^{226}Ra$ stock solution, bias with added concentration was approximately 1% and the correlation curve between $^{226}Ra$ concentration in simulated standard sample and measured $^{226}Ra$ concentration showed good agreement with a correlation coefficient ($R^2$) of 0.99. In analyzed CRM, maximum bias with reference value was 5.8% (k=1) and the analytical results were in good agreement with the reference value.

Estimation of Diagnostic Range for Measurement Tools, while BMD Testing to Health Examination in Transitional Ages (생애전환기 건강진단 골밀도 검사시 측정도구에 따른 진단범위의 유효성 평가)

  • Kim, Nam-Soo;Jung, Kyung-Sick;Kang, Eun-Jung;Oh, Jung-Eun;Lee, Byung-Kook
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.385-394
    • /
    • 2012
  • The aim of this study was to determine the effectiveness of diagnostic range for BMD measurement tools(DEXA, QUS, and RA) to health examination in transitional ages. In standard T-score -2.5 of DEXA, cutoff value by RA is -1.675(sensitivity: 70.0%, specificity: 63.7%) and cutoff value by QUS is -1.733(sensitivity: 70.4, specificity: 59.5%), also T-score -3.0 of DEXA, cutoff value by RA is -2.325(sensitivity: 70.0%, specificity: 42.9%) and cutoff value by QUS is -2.323(sensitivity: 70.4, specificity: 56.8%). There was, however, no significant difference in standard DEXA(lumbar spine and femur) between RA and QUS by repeat measurement(precision), and correlation were without effect. ROC analysis showed that all methods are qualified for BMD measurement tools to health examination in transitional ages; however, the different sensitivities and specificities of the methods, as well as age and gender, calibration parameters for diagnostic tests have to be considered.

Study of the determination of 226Ra in soil using liquid scintillation counter (액체섬광계수기를 이용한 토양 중 226Ra 분석 방법 연구)

  • Jung, Yoonhee;Kim, Hyuncheol;Chung, Kun Ho;Kang, Mun Ja
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.65-72
    • /
    • 2016
  • This study presented an analytical method for detecting radium in soils using a liquid scintillation counter (LSC). The isotope 226Ra was extracted from soil using the fusion method and then separated from interfering radionuclides using the precipitation method. Radium was coprecipitated as sulfate salts with barium (Ba) and then converted into Ba(Ra)CO3, which is soluble in an acidic solution. The isotope 222Rn, the decay progeny of 226Ra, was trapped in a water immiscible cocktail and analyzed by LSC. The pulse shape analysis (PSA) level was estimated using 90Sr and 226Ra standard solutions. The figure of merit was the highest at PSA 80, while the alpha spillover was the lowest at PSA 80. The counting efficiency was 243 ± 2% in a glass vial. This analytical method was verified with International Atomic Energy Agency (IAEA) reference materials, including IAEA-312, IAEA-314, and IAEA-315. The recovery ranged from 60–82%, while the relative bias between the measured value and the recommended value was less than 10%. The minimum detectable activity was 2.1 Bq kg−1 with dry mass 1 g, the background count rate of 0.02 cpm, the recovery rate of 70% and counting time of 30 min.

The Verification for Extreme Hydrological Variables of HadGEM3-RA (HadGEM3-RA 자료의 극치수문변수에 대한 검증)

  • Sung, Jang-Hyun;Kang, Hyun-Suk;Park, Su-Hee;Cho, Chun-Ho;Kim, Young-Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.122-122
    • /
    • 2011
  • 수자원 분야에서 기후변화 관련 연구는 치수 측면 보다는 이수 측면에서 주로 이뤄지고 있다. 이는 홍수분석을 위한 시간 단위를 충족시켜주는 전지구 대기순환모형(Global Circulation Model: GCM)의 자료가 드물고, 시간 단위의 GCM 자료라 하더라도 극치값(extreme value) 표현에는 한계가 있기 때문이다. 이를 극복하기 위하여 과거 관측자료의 통계적 특성으로 극치자료의 편의(bias)를 보정하고 시간 단위로 분해하기도 한다. 하지만 이런 통계적 상세화(statistical downscaling)는 미래 기후는 과거자료와 통계적 차이가 유의하지 않음을 가정하고 있어, 미래 기후는 현재와 다를 것이라는 공감대에 는 적합하지 않다. 이와 같은 이유로 타당한 극치수문변수 결과를 얻기 위해서는 시간 단위의 고분해능(high resolution) GCM이나 지역기후모델(regional climate model)과 같은 고해상도의 미래 기후변화 자료가 필요하게 된다. 이에 국립기상연구소에서는 영국 기상청의 통합모델(UM)기반의 지역기후모델(HadGEM3)을 사용하여 50 km 및 12.5 km 격자 단위로 역학적 상세화(dynamic downscaling)를 수행하였다. 본 연구에서는 개발된 HadGEM3-RA 결과의 극치수문변수 검증을 위하여 한강유역의 관측 자료와 다양한 방법으로 비교하였다. 두 자료의 극치값을 GEV (Generalized Extreme Value) 분포에 적합(fitting)시켜 비초과확률별 극치사상과, 특정 임계값(threshold value) 이상의 극치사상 발생확률을 비교하였다. 검토 결과, HadGEM3-RA는 통계적 상세화로 구한 극치값 보다는 작았으나 기존의 지역 기후모델에 비하여 현실성 있는 극치값이 계산되었음을 확인하였다.

  • PDF

The Study of Flexural Strength of Full Zirconia Crown using Block after Clinical Work (Full Zirconia Crown용으로 사용되는 block의 제조사의 굴곡강도와 임상작업후의 굴곡강도에 관한 연구)

  • Jung, Hyo-Kyung;Kwak, Dong-Ju
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.283-289
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate flexural strength of full zirconia crown using block after clinical work. Methods: The three point bending test was used to measure the flexural strength of zirconia block. Statistical analysis was done using the Statistical Package for Social Sciences version 19.0 for Windows. As for the analysis methods, the study used analysis of variance, Tukey's test. Results: The ave Rage value of flexural strengths of WIELAND, Zirkonzahn, Hass, D-MAX were 516.2 MPa, 612.6MPa, 566.2MPa, 744.6MPa. The ave Rage value of Surface Roughness of WIELAND, Zirkonzahn, Hass, D-MAX were 0.39Ra, 0.33Ra, 0.33Ra, 0.47Ra. Conclusion: Flexural strength of zirconia block decreased after clinical work. Flexural strength of zirconia block is equal to or higher than flexural strength of dental metal, so zirconia block can be used as dental material.

Measurement of Radon Daughters in Airborne Dust (공기부유진내(空氣浮游塵內)의 Radon 붕괴생성물(崩壞生成物)의 농도측정(濃度測定))

  • Kim, Pill-Soo;Min, Duck-Kee;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.2 no.1
    • /
    • pp.9-16
    • /
    • 1977
  • A simple method has been established for determining RaA, RaB and RaC concentrations in airborne dust. This is to evaluate the concentration from measurement of total alpha activities in three selected-time intervals after an air sample is taken from the membrane filter paper (mean pore size: $0.8{\mu}m$). As a preliminary trial, a time-variation of the concentrations has been determined using the single-filter method at the KAERI site (N. Lat. $37^{\circ}38'$ and E. Long $127^{\circ}15'$), Seoul, Korea. It appears that there is a large variation of the concentrations depending on the sampling time. Generally the highest value was observed in the morning that may coincide with the highest density of atmosphere in a day while the lowest value was obtained around fourteen o'clock.

  • PDF

A Study on Sa(紗) and Ra(羅) at the End of the Joseon Period (조선 말기 사ㆍ라에 관한 연구)

  • 이은진;조효숙
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.8
    • /
    • pp.121-135
    • /
    • 2003
  • The purpose of this study is to suggest a theoretical basis to name Sa(紗) and Ra(羅) remains properly by comparing and analyzing the name, usage, value, length and width of Sa(紗) and Ra(羅) recorded on documents made at the end period of Joseon. The features of Sa(紗) and Ra(羅) at the end of the Joseon Period are as follows. 1. The kinds of Sa(紗) are about 80, those of Ra(羅) are about 12, and those of Sa(紗) are significantly more than those of Ra(羅). In regard to the aspect of patterns, there were about 20 types of patterns in the case of Sa(紗), but no specific pattern for Ra(羅). 2. Some newly revealed patterns in the case of Sa (紗) are as follows. Baek -bok-mun(백복문) was a pattern full of ‘bats(박쥐[복])’, and Baek-jeop-mun(백접문) was a pattern full of ‘butterflies(나비[蝶])’ Jeop-mun(접문) was classified into ‘butterfly patterns(나비문[접문])’ and ‘traditional window flame patterns(창살문[접문])‘. 3. When considering the usages of Sa(紗) and Ra(羅), Sa(紗) was used for various detailed purposes according to their kinds and patterns, but Ra(羅) was mostly used for underwear. The most commonly used Sa(紗) was the Gab-sa type(甲紗類). On the contrary, the Go-sa type(庫紗類) was significantly less used than the Gab-sa type(甲紗類). However, it must have been of relatively high quality Sa(紗), shown by the fact that it was used for outer garments. In addition, the Gung-sa type(宮紗類) was the best quality Sa(紗), shown by the fact that it was used for court dress and official uniforms in the royal court. 4. Sa(紗) and Ra(羅) whose features have been examined we Gapsa(甲紗), Sun-in (純仁), Gosa(庫紗), Gwansa(官紗), Jusa(走紗), Eunjosa(은조사), Gwangsa(廣紗), Waesa(倭紗), Dorisa(도리사), Gong-yangsa(공양사), Rasa(羅紗), Danghangra(唐亢羅), Yanghangra(洋亢羅), Yunjura(윤주라), Eunra(銀羅), Jeohangra(저항라), Chura(秋羅). 5. Regarding the values of Sa(紗) and Ra(羅), they were high quality textures and its length and width of 1 Pil(疋), a roll of cloth, were not subdivided in detail such as in the case of plain weaved silks(平絹).

On the Numerical Stability of Dynamic Reliability Analysis Method (동적 신뢰성 해석 기법의 수치 안정성에 관하여)

  • Lee, Do-Geun;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.49-57
    • /
    • 2020
  • In comparison with the existing static reliability analysis methods, the dynamic reliability analysis(DyRA) method is more suitable for estimating the failure probability of a structure subjected to earthquake excitations because it can take into account the frequency characteristics and damping capacity of the structure. However, the DyRA is known to have an issue of numerical stability due to the uncertainty in random sampling of the earthquake excitations. In order to solve this numerical stability issue in the DyRA approach, this study proposed two earthquake-scale factors. The first factor is defined as the ratio of the first earthquake excitation over the maximum value of the remaining excitations, and the second factor is defined as the condition number of the matrix consisting of the earthquake excitations. Then, we have performed parametric studies of two factors on numerical stability of the DyRA method. In illustrative example, it was clearly confirmed that the two factors can be used to verify the numerical stability of the proposed DyRA method. However, there exists a difference between the two factors. The first factor showed some overlapping region between the stable results and the unstable results so that it requires some additional reliability analysis to guarantee the stability of the DyRA method. On the contrary, the second factor clearly distinguished the stable and unstable results of the DyRA method without any overlapping region. Therefore, the second factor can be said to be better than the first factor as the criterion to determine whether or not the proposed DyRA method guarantees its numerical stability. In addition, the accuracy of the numerical analysis results of the proposed DyRA has been verified in comparison with those of the existing first-order reliability method(FORM), Monte Carlo simulation(MCS) method and subset simulation method(SSM). The comparative results confirmed that the proposed DyRA method can provide accurate and reliable estimation of the structural failure probability while maintaining the superior numerical efficiency over the existing methods.

A study on surface roughness depending on cutting direction and cutting fluid type during micro-milling on STAVAX steel (STAVAX 강의 마이크로 밀링 중 가공 방향 및 절삭유체 분사형태에 따른 표면 거칠기 경향에 관한 연구)

  • Dong-Won Lee;Hyeon-Hwa Lee;Jin Soo Kim;Jong-Su Kim
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.22-26
    • /
    • 2023
  • As Light-Emitting Diodes(LEDs) continue to advance in performance, their application in automotive lamps is increasing. Automotive LEDs utilize light guides not only for aesthetics but also to control light quantity and direction. Light guides employ patterns of a few hundred micrometers(㎛) to regulate the light, and the surface roughness(Ra) of these patterns can reach tens of nanometers(nm). Given that these light guides are produced through injection molding, mold processing technology with high surface quality micro-patterns is required. This study serves as a preliminary investigation into the development of high surface quality micro-pattern processing technology. It examines the surface roughness of the workpiece based on the cutting direction of the pattern and the cutting fluid type when cutting micro-patterns on STAVAX steel using cubic Boron Nitride(cBN) tools. The experiments involved machining a step-shaped micro-pattern with a height of 60 ㎛ and a pitch of 400 ㎛ in a 22×22 mm area under identical cutting conditions, with only the cutting direction and cutting fluid type being varied. The machining results of four cases were compared, encompassing two cases of cutting direction(parallel to the pattern, orthogonal to the pattern) and two cases of cutting fluid type (flood, mist). Consequently, the Ra value was found to be the highest(Ra 128.33 nm) when machining with the flood type in parallel to the pattern, while it was the lowest(Ra 95.22 nm) when machining with the mist type orthogonal to the pattern. These findings confirm that there is a difference of up to 25.8 % in the Ra value depending on the cutting direction and cutting fluid type.