대체냉매를 사용한 평활관 및 마이크로핀관 곡관부내 증발 열전달 특성 (Evaporation heat transfer characteristics inside the U-bend of the smooth and the microfin tube using alternative refrigerant)

  • 조금남;김병기
    • 대한기계학회논문집B
    • /
    • 제21권9호
    • /
    • pp.1207-1217
    • /
    • 1997
  • The present work experimentally investigated the effects of mass flux, heat flux, inlet quality on the heat transfer performance inside the U-bend of smooth and microfin tube using R-22 and R-407C refrigerants. The parameters were 200 and 400 kg/m$^{2}$ s for mass flux, 6 and 12 kw/m$^{2}$ for heat flux, 0.1 and 0.2 for inlet quality under the pressure of 0.65 MPa. The apparatus consisted of the test section of four straight sections and three U-bends, preheater, condenser, refrigerant pump, mass flow meter etc. The average heat transfer coefficient at the downstream straight section after U-bend was affected by U-bend due to the centrifugal force and mixing of two-phase flow in the U-bend. The average heat transfer coefficient at the U-bend was 4 ~ 33 % higher than that at the straight section. The average heat transfer coefficients were affected in the order of mass flux, heat flux and inlet quality. The average heat transfer coefficients in the microfin tube were lager by 19 ~ 49% and 33 ~ 69% than that in the smooth tube at the straight section and at the U-bend separately. The average heat transfer coefficients for R-407C were larger by 33 ~ 41% and 17 ~ 29% than that for R-22 in the smooth tube and the microfin tube separately.

낮은 핀관에서 대체냉매의 풀비등 열전달계수 (Pool boiling heat transfer coefficients of alternative refrigerants on low fin tubes)

  • 송길홍;이준강;정동수;김종보
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.411-422
    • /
    • 1998
  • In this study, experiments were carried out to provide nucleate pool boiling heat transfer data for a plain tube and 4 different low fin tubes employing 2 refrigerant mixtures of R410A, R407C, and 12 pure fluids. Low fin tubes were machined on a 19.05mm nominal outside diameter copper block according to the manufacturer's low fin tube specifications. Cartridge heaters were used to generate uniform heat flux on the tubes. For all refrigerants, heat flux varied from 10㎾/$\m^2$ to 80㎾/$\m^2$. It is found that heat transfer coefficients(HTCs) of high vapor pressure refrigerants are usually higher than those of low pressure fluids. On the other hand, the fin effect was more prominent with low pressure refrigerants than with high pressure ones. Optimum fin density as well as the increase in heat transfer coefficient with the increase in fin density were found to be strongly fluid dependent. HTCs of Rl23, a low pressure alternative refrigerant, were similar to those of Rll while HTCs of R134a, an intermediate pressure alternative refrigerant, were roughly 20% higher than those of Rl2. Finally, HTCs of R32, R125, R143a, and R410A were all higher than those of R22 by 30~50%.

  • PDF

미세휜관내 윤활유를 포함한 대체냉매의 압력강하 예측에 관한 연구 (Study on the Prediction of Pressure Drop for Alternative Refrigerants with lubricant in Micro-Fin Tubes)

  • 최준영;이진호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.83-89
    • /
    • 2000
  • This paper presents a pressure drop correlation for evaporation and condensation of alternative refrigerant with oil in micro-fin tubes. The correlation was developed from a data base consisting of oil-free pure and mixed refrigerants in micro-fin tube; Rl25 R134a. R32 R410a(R32/R125 50/50% mass), R22, R407c(R32/R125/R134a, 23/25/52% mass) and R32/R134a(25/75% mass). The micro-fin tube used in this paper had 60 0.2mm high fins with a 18 helix angle. The cross sectional flow area $(A_c)$ was $60.8 mm^2$ giving an equivalent smooth diameter$(D_e)$ of 8.8mm. The hydraulic diameter $(D_h)$ was estimated to the 5.45mm. The new correlation was obtained by replacing the friction factor and the tube-diameter in Bo Pierre correlation by a friction factor derived from pressure drop data for a micro-fin tube and the hydraulic diameter, respectively. This correlation was also used to predict some pressure data with a lubricant after using a mixing viscosity rule of lubricants and refrigerants. As a result, the new correlation was also well predicted to the measured data within a mean deviation of 19.0%.

  • PDF

친수성 폴리머 제피를 이용한 말레인산암로디핀 정제의 안정성 개선 (Stability Improvement of Amlodipine Maleate Tablets using Aqueous Polymer Coating Technique)

  • 최인식;신택환;최성업;이재휘;최영욱
    • Journal of Pharmaceutical Investigation
    • /
    • 제34권5호
    • /
    • pp.407-411
    • /
    • 2004
  • New formulations of amlodipine maleate tablet have been investigated to enhance the stability of the drug against light and humidity. Three kinds of amlodipine maleate tablets were prepared. One is prepared by previously known formulation (formulation C), the others were by new formulations using hydrophilic polymer $(Opadry^{\circledR})$ coated granules (formulations A and B). Amlodipine maleate powder was coated with $Opadry^{\circledR}$ to produce the coated granules and it was mixed with other excipients to produce the tabletting mass of new formulations A and B. Dissolution rate of newly formulated tablets was over 80% within 10 minutes in 0.01 M HCl medium, and its dissolution pattern was similar to that of $Norvasc^{\circledR}$ tablet. After 6 months storage under accelerated conditions, residual drug contents of tested formulations (A and B) were not significantly different from formulation C, ranging from 96.2 to 100.4%. Meanwhile, dissolution amount of formulation C was significantly reduced compared to that of formulation A (p<0.05), showing formulation A was more stable than unprotected formulation C at the accelerated conditions. Results of appearance, hardness and disintegration remained unchanged during stability study. In conclusion, it showed that the new formulations had enhanced the stability characteristics and hydrophilic coating technique was an alternative and promising method to improve the stability of amlodipine maleate tablet.

HFC 및 탄화수소를 포함한 R-22 대체냉매의 성능평가 (Performance Evaluation of R-22 Alternative Refrigerants with Hydrofluorocarbon and Hydrocarbon)

  • 김창년;박영무;이병권;임종성
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.315-324
    • /
    • 2000
  • R-410A, R-407C, and four refrigerant mixtures composed of R-32, R-l34a, R-l43a, R-l52a, R-600(butane), and R-600a(isobutane) were tested in an attempt to replace R-22 used in most of the residential air conditioners. The performance evaluation was carried out in a psychrometric calorimeter test facility using a residential spilt type air conditioner under the KS rating conditions. Except for the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; COP, capacity, compressor power, and VCR. R-410A was shown to have 5.5% higher COP and 3.5% lower capacity than R-22. R-32/134a/600a (42.8/ 46.0/11.2 wt%) mixture have the best performance among the four refrigerant mixtures composed of hydrofluorocarbon and hydrocarbon. This inixture have 3.0% lower COP and 1.6% lower capacity than R-22.

  • PDF

주요 식용꽃 추출물의 폴리페놀과 카테킨류 함량이 항산화 활성에 미치는 영향 (Effects of Polyphenol and Catechin Levels on Antioxidant Activity of Several Edible Flower Extracts)

  • 이미경;박정숙;송희자;천상욱
    • 한국자원식물학회지
    • /
    • 제27권2호
    • /
    • pp.111-118
    • /
    • 2014
  • 주요한 꽃차의 재료로 이용되고 있는 백목련, 매화 및 홍화의 성분 및 생리활성 차이를 검토하고자 폴리페놀 함량, 플라보노이드 함량, 카테킨류 함량 및 항산화성을 분석하였다. 각종 시료의 에탄올 추출물로부터 총 페놀 함량을 Folin-Denis 방법으로 측정한 결과 표준물질을 catechin, chlorogenic acid, tannic acid로 각각 달리하여 측정한 결과 백목련이 72.6 ~ 118.0 mg/kg 범위로 가장 높게 나타났고 그 다음이 매화와 홍화 순으로 나타났다. 한편, 총 플라보노이드 함량은 백목련이 25.1 mg/kg으로 높게 나타났으나 다른 꽃과의 유의적인 차이는 없는 것으로 나타났다. 항산화성을 알아보기 위해 DPPH 라디컬 소거능을 측정한 결과 250 mg/kg의 추출물 농도에서 백목련과 매화는 각각이 93.0과 92.6%로 높게 나타났으나, 홍화는 23.0%로 낮은 활성을 보였다. 총 catechin 함량에 있어서 백목련이 총 8종의 카테킨류 중 6종의 화합물이 함유되어 있었고 9,425.5 mg/kg으로 가장 높게 나타났고, 매화와 홍화는 각각 5종과 2종의 화합물이 함유되어 각각 3,407.8과 190.6 mg/kg으로 낮게 나타났다. 한편 카페인 함량은 매화에서 비타민 C함량은 매화와 홍화가 가장 높은 함량을 보였다. 백목련 꽃은 다른 꽃에 비해 폴리페놀과 플라보노이드 함량이 높고 항산화성이 높아 유망한 기능성 꽃차로서 이용성이 높을 것으로 기대된다. 또한 꽃차의 총 페놀, 총 플라보노이드 및 총 카테킨류 함량은 그들의 항산화성과의 높은 상관계수를 보임으로써 연관성이 높음을 알 수 있었다.

HCFC-22 대체냉매의 모세관 선정 (Selection of Capillary Tubes for HCFC-22 Alternative Fluids)

  • 정동수;김종보
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.435-449
    • /
    • 1995
  • In this paper, pressure drop through a capillary tube is modeled to determine the length of a capillary tube for a given set of conditions. HCFC-22 and its alternatives, HFC-134a, R407B, and R410A are used as working fluids. The conditions on which the model is tested are as follows : condensing temperature; 40.0, 45.0, 50.0, $55.0^{\circ}C$, degree of subcooling;0.0, 2.5, $5.0^{\circ}C$, capillary tube exit condition;choked flow, capillary tube diameter;1.2~2.4mm, mass flow rate;5.0~50.0g/sec. The results justify the use of Stoecker's model which yields the results very close to the values in ASHRAE handbook. While McAdams' method yields much better results than Duckler's in calculating the viscosity of the fluid in 2-phase, the friction factor suggested by Stoecker seems to be the best for capillary tubes of large diameter used in residential air conditioners. For each refrigerant, 372 data with various variables are calculated by the model. The results show that capillary tube length varies very uniformly with changes in condensing temperature and degree of subcooling. Based on this fact, regression analysis is performed to determine the dependence of mass flow rate on the length and diameter of a capillary tube, condensing temperature, and degree of subcooling. Thus determined correlation yields a mean deviation of 2.36% for 1,488 data, showing an excellent agreement.

  • PDF