• 제목/요약/키워드: R2-MRI

검색결과 170건 처리시간 0.023초

선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가 (Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array)

  • 이동훈;홍철표;한봉수;김형진;서재준;김소현;이춘형;이만우
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

3차원 볼륨 렌더링을 이용한 가상 돌출형 전립선 부피 평가 (Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering)

  • 성열훈;주용현;임재동;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.208-215
    • /
    • 2009
  • 2차원의 영상을 이용한 돌출형 전립선 비대증의 부피 평가방법에서 돌출부위를 포함시킬 경우와 포함시키지 않을 경우의 부피변화를 3차원 볼륨 렌더링(volume rendering, VR)을 이용하여 비교 평가하고자 한다. 돌출형 전립선 부피측정을 위한 가상 전립선 모델은 곤약을 이용해 임의로 평균 1 cm 정도로 돌출되도록 하여 10 ml에서 각각 10 ml씩 부피를 변화시켜 100 ml까지 총 10 개의 모델을 제작하였다. 이 때 제작된 모델의 부피측정은 64 channel 전산화단층촬영(computed tomography, CT)과 3.0 Tesla 자기공명영상(magnetic resonance image, MRI)을 이용하여 획득된 3차원 볼륨 영상자료로 계측하였다. 산출한 CT와 MRI영상들의 3차원 볼륨데이터 근접성 평가를 위해 wilcoxon 부호순위(signed rank) 검정을 하였다. 또한 획득한 영상자료는 3차원 영상처리를 통하여 볼륨 렌더링으로 재구성한 후 타원체부피공식법을 이용하여 돌출부위를 포함시킬 때와 포함하지 않을 때의 부피를 구하였다. 이 때 돌출 유무에 따라 각각 측정된 부피와 3차원 볼륨 렌더링의 부피를 wilcoxon 부호순위(signed rank) 검정을 사용하여 유의성을 평가했으며 상관계수(pearson's correlation coefficient, r)를 사용하여 상관관계를 분석하였다. 계측된 가상 전립선 모델의 돌출부위길이는 CT에서 $0.90{\pm}0.18\;mm$, MRI에서 $0.75{\pm}0.11\;mm$이었으며, CT와 MRI에서 계측된 3차원 영상 부피의 p-value는 0.414로 유의한 차이는 없었다. 그러나 MRI에서 측정된 3차원 영상 부피와 2차원 영상에서 돌출부위를 포함시킬 때의 p-value는 0.005인 반면 포함하지 않을 때의 p-value는 0.139로 나타났으며, CT에서도 측정된 3차원 영상 부피와 2차원 영상에서 돌출부위를 포함시킬 때의 p-value는 0.005인 반면 포함하지 않을 때의 p-value는 0.057로 나타났다. 돌출형 전립선의 부피측정은 돌출부위를 제외하고 상하길이를 측정하는 것이 3차원 볼륨 렌더링에 의한 부피 값과 더 가까운 부피 값을 얻을 수 있었다.

  • PDF

Maximum diameter versus volumetric assessment for the response evaluation of vestibular schwannomas receiving stereotactic radiotherapy

  • Choi, Youngmin;Kim, Sungmin;Kwak, Dong-Won;Lee, Hyung-Sik;Kang, Myung-Koo;Lee, Dong-Kun;Hur, Won-Joo
    • Radiation Oncology Journal
    • /
    • 제36권2호
    • /
    • pp.114-121
    • /
    • 2018
  • Purpose: To explore the feasibility of maximum diameter as a response assessment method for vestibular schwannomas (VS) after stereotactic radiosurgery or fractionated stereotactic radiotherapy (RT), we analyzed the concordance of RT responses between maximum diameters and volumetric measurements. Materials and Methods: Forty-two patients receiving curative stereotactic radiosurgery or fractionated stereotactic RT for VS were analyzed retrospectively. Twelve patients were excluded: 4 did not receive follow-up magnetic resonance imaging (MRI) scans and 8 had initial MRI scans with a slice thickness >3 mm. The maximum diameter, tumor volume (TV), and enhanced tumor volume (ETV) were measured in each MRI study. The percent change after RT was evaluated according to the measurement methods and their concordances were calculated with the Pearson correlation. The response classifications were determined by the assessment modalities, and their agreement was analyzed with Cohen kappa statistics. Results: Median follow-up was 31.0 months (range, 3.5 to 86.5 months), and 90 follow-up MRI studies were analyzed. The percent change of maximum diameter correlated strongly with TV and ETV (r(p) = 0.85, 0.63, p = 0.000, respectively). Concordance of responses between the Response Evaluation Criteria in Solid Tumors (RECIST) using the maximum diameters and either TV or ETV were moderate (kappa = 0.58; 95% confidence interval, 0.32-0.85) or fair (kappa = 0.32; 95% confidence interval, 0.05-0.59), respectively. Conclusions: The percent changes in maximum diameter and the responses in RECIST were significantly concordant with those in the volumetric measurements. Therefore, the maximum diameters can be used for the response evaluation of VS following stereotactic RT.

A feasibility study evaluating the relationship between dose and focal liver reaction in stereotactic ablative radiotherapy for liver cancer based on intensity change of Gd-EOB-DTPA-enhanced magnetic resonance images

  • Jung, Sang Hoon;Yu, Jeong Il;Park, Hee Chul;Lim, Do Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • 제34권1호
    • /
    • pp.64-75
    • /
    • 2016
  • Purpose: In order to evaluate the relationship between the dose to the liver parenchyma and focal liver reaction (FLR) after stereotactic ablative body radiotherapy (SABR), we suggest a novel method using a three-dimensional dose distribution and change in signal intensity of gadoxetate disodium-gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) hepatobiliary phase images. Materials and Methods: In our method, change of the signal intensity between the pretreatment and follow-up hepatobiliary phase images of Gd-EOB-DTPA-enhanced MRI was calculated and then threshold dose (TD) for developing FLR was obtained from correlation of dose with the change of the signal intensity. For validation of the method, TDs for six patients, who had been treated for liver cancer with SABR with 45-60 Gy in 3 fractions, were calculated using the method, and we evaluated concordance between volume enclosed by isodose of TD by the method and volume identified as FLR by a physician. Results: The dose to normal liver was correlated with change in signal intensity between pretreatment and follow-up MRI with a median $R^2$ of 0.935 (range, 0.748 to 0.985). The median TD by the method was 23.5 Gy (range, 18.3 to 39.4 Gy). The median value of concordance was 84.5% (range, 44.7% to 95.9%). Conclusion: Our method is capable of providing a quantitative evaluation of the relationship between dose and intensity changes on follow-up MRI, as well as determining individual TD for developing FLR. We expect our method to provide better information about the individual relationship between dose and FLR in radiotherapy for liver cancer.

Utility of False Profile View for Screening of Ischiofemoral Impingement

  • Kwak, Dae-Kyung;Yang, Ick-Hwan;Kim, Sungjun;Lee, Sang-Chul;Park, Kwan-Kyu;Lee, Woo-Suk
    • Hip & pelvis
    • /
    • 제30권4호
    • /
    • pp.219-225
    • /
    • 2018
  • Purpose: Ischiofemoral impingement (IFI)-primarily diagnosed by magnetic resonance imaging (MRI)-is an easily overlooked disease due to its low incidence. The purpose of this study was to evaluate the usefulness of false profile view as a screening test for IFI. Materials and Methods: Fifty-eight patients diagnosed with IFI between June 2013 and July 2017 were enrolled in this retrospective study. A control group (n=58) with matching propensity scores (age, gender, and body mass index) were also included. Ischiofemoral space (IFS) was measured as the shortest distance between the lateral cortex of the ischium and the medial cortex of lesser trochanter in weight bearing hip anteroposterior (AP) view and false profile view. MRI was used to measure IFS and quadratus femoris space (QFS). The receiver operating characteristics (ROC), area under the ROC curve (AUC) and cutoff point of the IFS were measured by false profile images, and the correlation between the IFS and QFS was analyzed using the MRI scans. Results: In the false profile view and hip AP view, patients with IFI had significantly decreased IFS (P<0.01). In the false profile view, ROC AUC (0.967) was higher than in the hip AP view (0.841). Cutoff value for differential diagnosis of IFI in the false profile view was 10.3 mm (sensitivity, 88.2%; specificity, 88.4%). IFS correlated with IFS (r=0.744) QFS (0.740) in MRI and IFS (0.621) in hip AP view (P<0.01). Conclusion: IFS on false profile view can be used as a screening tool for potential IFI.

알코올 사용 장애자의 언어 작업 기억과 관련된 뇌의 보상 기전: fMRI 연구 (fMRI evidence of compensatory mechanisms during a verbal working memory task in individuals with alcohol use disorders)

  • 박미숙;손선주;박지은;음영지;김숙희;유인규;손진훈
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2009년도 춘계학술대회
    • /
    • pp.101-104
    • /
    • 2009
  • This study investigated compensatory mechanisms in the brain during a verbal working memory task among people with Alcohol Use Disorders (AUD). A total of 21 college male students participated in the study: eleven AUD participants and 10 normal controls. Study participants were asked to complete the Korean version of the Wechsler Adult Intelligence Scale-III (K-WAIS-III) prior to the fMRI experiment. Verbal 0-back and 2-back tasks were used to assess brain activities of the participants' verbal working memory. Brain scanning was performed on Siemens SONATA 1.5T Scanner while participants were performing the 0-back and 2-back tasks. Within the AUD group, participants with greater dependency to alcohol (based on DSM-IV criteria) in the past 1 year showed lower mean score on the 'Similarities' of the K-WAIS-III (r=-0.63, p<0.05, N=11). The more participants experienced alcohol withdrawal symptoms in the past 1 year, the lower the score they received on the K-WAIS-III 'Picture Arrangement' (r=-0.69, p<0.05, n=11). The fMRI regression results showed that individuals who present greater degree of alcohol dependency symptoms are likely to show greater brain activation in the bilateral middle frontal gyri (BA 9) during the verbal working memory task. The degree of alcohol withdrawal symptoms were associated with increased brain activation in the left superior and middle frontal gyri (BA8), left precentral gyrus (BA 6), and left inferior parietal lobule (BA 40). The study findings showed that the degree of alcohol abuse/dependence and withdrawal symptoms were associated with decreased cognitive function and increased activations in brain regions particularly important for abstract reasoning (BA 9), central executive (BA 9), or spatial storage (BA 40) during a working memory task. Therefore, these results could support previous studies suggesting that the neural system of people with ADD may adopt a brain compensatory mechanism to maintain normal level of cognitive functions.

  • PDF

유방자기공명영상에서 3 차원 최대 강도 투사 재건 영상의 유용성 (Usefulness of Three-Dimensional Maximal Intensity Projection (MIP) Reconstruction Image in Breast MRI)

  • 김현성;강봉주;김성헌;최재정;이지혜
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권2호
    • /
    • pp.183-189
    • /
    • 2009
  • 목적 : 유방자기공명영상에서 3 차원 최대 강도 투사 (3D MIP) 재건 영상의 유용성을 알아보고자 하였다. 대상 및 방법 : 유방암으로 진단받고 유방자기공명영상을 시행한 27명의 환자의 54개의 유방을 대상으로 하였다. GE Signa Excite Twin speed (GE medical system, Wisconsin, USA) 1.5 T 기기를 이용하여 기본 영상으로 축면 T2 강조 T1 강조 영상과 시상면 T1 강조 지방 억제 영상, 역동적 조영 증강 영상과 감산 영상을 얻었다. 이후 초기 역동적 조영증강 영상의 감산영상으로 워크스테이견 (GE Medical system)을 이용하여 3D MIP 영상을 얻었다. 3D MIP 영상과 기본 유방자기공명영상에서 발견된 병변을 ACR BI-$RADS^{(R)}$ MRI lexicon에 따라 분석하였다. 각각의 영상에서 발견된 병변의 소견들을 비교하고 3D MIP에서 기본자기공명영상에서 보다 추가적인 정보를 얻을 수 있는지 알아보았다. 결과 : 종괴의 경우 기본 유방자기공명영상에서 보이는 56개 중 43개가 3D MIP 영상에서 발견되었다 (76.8%). 비종괴성 조영 증강의 경우 20개 중 17개가 발견되었다 (85%). 169개의 초점성 조영증강 병변이 3D MIP 영상에서, 109개가 기본 유방자기공명영상에서 확인되었다. 3D MIP 영상에서 60.9%의 category 3병변이 발견되었고(14/23), 68.87%의 category 4 병변 (11/16), 100%의 category 5병변 (28/28)이 발견되었다. 3D MIP 영상에서 분석된 조영증강 병변들의 category가 기본 유방 자기공명 영상의 결과들과 통계적으로 일치하였다(p-value < 0.0001). 기본 유방 자기공명 영상에서 초점으로 분석된 2개의 병변들이 3D MIP 영상에서는 다초점성의 악성 병변으로 발견되었고, 1개의 추가적 병변이 3D MIP 영상에서만 발견되었다. 결론 : 3D MIP 영상은 한계점들을 갖고 있으나, 기본 유방자기공명영상의 분석에 있어 추가적으로 이용 시 유용하다.

  • PDF

멀티 생체신호 동기 시스템을 이용한 심장자기공명영상 (Cardiac Magnetic Resonance Imaging Using Multi-physiological Intelligent Trigger System)

  • 박진호;윤종현;양영중;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권3호
    • /
    • pp.244-252
    • /
    • 2014
  • 목적 : 멀티 생체신호를 이용한 지능형 실시간 심장과 호흡에 동기화 하는 시스템을 사용하여 심장자기공명영상을 수행하였다. 또한 멀티 생체신호를 측정하는 과정에서 유기될 수 있는 eddy current의 특성을 분석하였다. 대상 및 방법 : 멀티 생체신호 동기화 시스템에서는 심전도 신호와 호흡신호 외에 추가로 $SPO_2$ 정보를 수집하여 심장의 움직임에 동기화 하였다. 심장운동의 동기화는 심전도와 함께 $SPO_2$의 이차미분 신호를 이용할 수 있음을 보였다. 심장 동기화 과정에서 피검자의 움직임과 부정맥에 의해 발생할 수 있는 잘못된 동기신호를 평균 R-R 시간을 이용하여 제거하였다. 심장 영상화를 위한 시퀀스에서 경사자계의 스위칭에 의해 유기될 수 있는 eddy current의 특성을 분석하여 하드웨어 및 소프트웨어 필터로 차단하였다. 결과 : 제안된 동기화 시스템을 이용하여 심장과 호흡 운동에 동기화된 심장자기공명영상을 얻었다. 심전도 신호에서 피검자의 움직임과 부정맥에 의해 발생할 수 있는 동기신호를 차단하였고, 심장 영상화 과정에서 유기될 수 있는 eddy current를 제거하였다. 또한 심전도 신호를 보완하여 $SPO_2$의 이차미분신호를 이용하여 심장 영상이 가능함을 보였다. 결론 : 본 논문에서 제안한 멀티 생체신호 동기화 시스템은 심장자기공명영상을 위해 여러 생체신호 (심전도, $SPO_2$, 호흡)를 이용하여 실시간으로 심장과 호흡 동기화를 수행한다. 심전도에서 피검사자의 움직임과 부정맥에 의해 발생할 수 있는 동기 신호를 차단하였다. 경사자계의 스위칭에 의해 생체신호에 유기될 수 있는 eddy current를 분석하였고, 심장과 호흡 동기를 병행하여 피검사자가 자유롭게 호흡하면서 심장 영상을 얻을 수 있었다.

성인에서 자기 공명 영상을 이용한 족관절 형태 계측 (Ankle Morphometry in Adults using MRI)

  • 유문집;김유진
    • 대한족부족관절학회지
    • /
    • 제11권1호
    • /
    • pp.18-22
    • /
    • 2007
  • Purpose: To provide basic data on anatomy of the ankle joint in adults using magnetic resonance imaging as well as to compare measurements with available data of corresponding dimension in the different sizes of the total ankle replacements design ($HINTEGRA^{(R)}$). Materials and Methods: Magnetic resonance (MR) sagittal and coronal images from one hundred-forty nine were studied. Post traumatic, arthritic, or grossly deformed ankles at any reason were excluded. Lengths, widths of the main parts of this articulation and also the radius of curvature of talar dome were measured in the MR images. Statistical analysis was performed on these measurements. Results: On MR coronal image data, average tibial width was $30.0{\pm}4.1\;mm$ and talar width was $27.0{\pm}3.4\;mm$. On sagittal image date, average anteroposterior length of the distal tibia was $39.0{\pm}4.2\;mm$, average anteroposterior length of the talus was $31.3{\pm}2.8\;mm$, and average sagittal radius of curvature of talar dome was $20.1{\pm}2.9\;mm$. All measurements in male were significantly larger than in female (p<0.01), but a significant difference according to age was not found. Conclusion: Ankle morphometric data define a basis of size, particularly useful in the design of ankle prostheses.

  • PDF

7.0T 동물용 MRI을 이용한 종양의 현성확산계수와 병리학적 소견의 평가 (Using a 7.0T animal MRI comparison of ADC values and Pathologic Findings)

  • 성재구;임청환
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2011년도 춘계 종합학술대회 논문집
    • /
    • pp.201-202
    • /
    • 2011
  • 본 연구에는 7.0T 동물용 자기공명영상장치를 이용하여 인간의 췌장암 세포인 CFPAC-1를 이종 이식한 쥐에서 자기공명영상을 획득하여 최적화된 검사 Protocol을 정립하며, 동물 실험에서 밝혀진 종양특성과 확산강조영상과의 비교 분석을 해보고 현성확산계수 영상이 췌장암 이종이식 모형의 종양 세포 내부 구조에 관하여 어떠한 정보를 제공 할 수 있는지 알아보고자 한다. 13마리의 쥐의 26개의 종양을 전형적으로 주입 후에 2~4주 뒤에 직경이 5~10mm가 되었을 때 imaged 하였으며, pathologic specimenm을 위해 sacrificed 하였다. isofluoran gas anesthesia를 이용하여 동물 마취 하였다. 사용된 장비로는 small-animal MR images (7.0-T)를 (Bruker BioSpin GmbH, Rheinstetten, Germany)이용하여 Fast T2-weighted 와 single-shot EPI DW image를 얻었다. 종양은 H&E 염색과 CD31와 VEGF에 대한 면역조직학 염색을 하여 종양의 cellularity와 microvessel density(MVD), 종양 내 괴사 정도를 평가하였다. CFPAC-1의 현성확산계수값은 $0.7327{\pm}0.1075{\pm}10^{-3}mm2/s$이였으며, 현성확산계수는 종양내 괴사 정도와 연관성을 보였다(R = 0.7417, p = 0.0001) 이처럼 현성확산계수는 종양 내 괴사 정도 등의 현미경적구조변화를 반영하는 대리인자로 사용될 수 있음을 확인하였다.

  • PDF