• Title/Summary/Keyword: R2-MRI

Search Result 170, Processing Time 0.023 seconds

Gadolinium Complex of 1,4,7,10-Tetraazacyclododecane-1,4,7-trisacetic acid (DO3A) Conjugate of [(p-aniline benzothiazole)methyl]pyridine as a Tumor-Targeting MRI Contrast Agent

  • Nam, Ki Soo;Jung, Ki-Hye;Chang, Yongmin;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3654-3658
    • /
    • 2013
  • The synthesis of a DO3A conjugate of [(p-aniline benzothiazole)methyl]pyridine ($L^2H_3$) and its gadolinium complex of the type [$Gd(L^2)(H_2O)$] ($GdL^2$) is described. The $R_1$ relaxivity ($=4.50mM^{-1}sec^{-1}$) and kinetic inertness of $GdL^2$ compares well with those of structurally analogous Dotarem$^{(R)}$ ($R_1=3.70mM^{-1}sec^{-1}$), a typical extracellular (ECF) MRI contrast agent (CA). Yet, by comparison with Dotarem$^{(R)}$, $GdL^2$ exhibits non-covalent interactions with human serum albumin (HSA) as evidenced by the ${\varepsilon}^*$ titration curve along with in vivo MR signal enhancement in both aorta and heart. Liver-specific nature of $GdL^2$ is also observed as excretion is made through gallbladder. Most notably, $GdL^2$ further demonstrates specificity toward the MDA-MB-231 breast cancer.

Relationship between liver iron concentration determined by R2-MRI, serum ferritin, and liver enzymes in patients with thalassemia intermedia

  • Al-Momen, Hayder;Jasim, Shaymaa Kadhim;Hassan, Qays Ahmed;Ali, Hayder Hussein
    • BLOOD RESEARCH
    • /
    • v.53 no.4
    • /
    • pp.314-319
    • /
    • 2018
  • Background Iron overload is a risk factor affecting all patients with thalassemia intermedia (TI). We aimed to determine whether there is a relationship of serum ferritin (SF) and alanine aminotransferase (ALT) with liver iron concentration (LIC) determined by R2 magnetic resonance imaging (R2-MRI), to estimate the most relevant degree of iron overload and best time to chelate in patients with TI. Methods In this cross-sectional study, 119 patients with TI (mean age years) were randomly selected and compared with 120 patients who had a diagnosis of thalassemia major (TM). Correlations of LIC, as determined by R2-MRI, with SF and ALT levels, were assessed in all participants. A P-value <0.05 was considered statistically significant. Results SF and LIC levels were lower in patients with TI than in those with TM; only ferritin values were significant. We found a statistically significant relationship between SF and LIC, with cut-off estimates of SF in patients with TI who had splenectomy and those who entered puberty spontaneously (916 and 940 ng/mL, respectively) with LIC >5 mg Fe/g dry weight (P<0.0001). A significant relationship was also found for patients with TI who had elevated ALT level (63.5 U/L), of 3.15 times the upper normal laboratory limit, using a cut-off for LIC ${\geq}5mg\;Fe/g\;dry\;weight$. Conclusion We determined the cut-off values for ALT and SF indicating the best time to start iron chelation therapy in patients with TI, and found significant correlations among iron overload, SF, and ALT.

Gadolinium Complexes of Bifunctional Diethylenetriaminepentaacetic Acid (DTPA)-bis(amides) as Copper Responsive Smart Magnetic Resonance Imaging Contrast Agents (MRI CAs)

  • Nam, Ki Soo;Park, Ji-Ae;Jung, Ki-Hye;Chang, Yongmin;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.2900-2904
    • /
    • 2013
  • We present the synthesis and characterization of DTPA-bis(histidylamide) (1a), DTPA-bis(aspartamide) (1b), and their gadolinium complexes of the type $[Gd(L)(H_2O)]$ (2a:L = 1a; 2b:L = 1b). Thermodynamic stabilities and $R_1$ relaxivities of 2a-b compare well with Omniscan$^{(R)}$, a well-known commercial, extracellular (ECF) MRI CA which adopts the DTPA-bis(amide) framework for the chelate: $R_1$ = 5.5 and 5.1 $mM^{-1}$ for 2a and 2b, respectively. Addition of the Cu(II) ion to a solution containing 2b triggers relaxivity enhancement to raise $R_1$ as high as 15.3 $mM^{-1}$, which corresponds to a 300% enhancement. Such an increase levels off at the concentration beyond two equiv. of Cu(II), suggesting the formation of a trimetallic ($Gd/Cu_2$) complex in situ. Such a relaxivity increase is almost negligible with Zn(II) and other endogenous ions such as Na(I), K(I), Mg(II), and Ca(II). In vivo MR images and the signal-to-noise ratio (SNR) obtained with an aqueous mixture of 2b and Cu(II) ion in an 1:2 ratio demonstrate the potentiality of 2 as a copper responsive MRI CA.

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.

Interference Issuses of Radio Frequency Identification Devices in Magnetic Resonance Imaging Systems and Computed Tomography Scan

  • Periyasamy, M.;Dhanasekaran, R.
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.295-301
    • /
    • 2015
  • We evaluated certain issues related to magnetic resonance imaging (MRI) coupled with the use of active 2.5 GHz radio frequency identification (RFID) tags for patient identification using low field (0.3 T) MRI and computed tomography (CT) scans. We also investigated the performance of the RFID reader located outside the MRI room by considering several factors. A total of ten active RFID tags were exposed to several MRI sequences and X-rays of CT scan. We found that only card type active RFID tags are suitable for patient identification purpose in MRI environment and both wristbands as well as card tags were suitable for the same in CT environment. Severe artifacts were found in the captured MRI and CT images when the area of the imaging was in proximity to the tags. No external factors affected the performance of active RFID reader stationed outside the MRI scan room.

Prediction of East Asian Brain Age using Machine Learning Algorithms Trained With Community-based Healthy Brain MRI

  • Chanda Simfukwe;Young Chul Youn
    • Dementia and Neurocognitive Disorders
    • /
    • v.21 no.4
    • /
    • pp.138-146
    • /
    • 2022
  • Background and Purpose: Magnetic resonance imaging (MRI) helps with brain development analysis and disease diagnosis. Brain volumes measured from different ages using MRI provides useful information in clinical evaluation and research. Therefore, we trained machine learning models that predict the brain age gap of healthy subjects in the East Asian population using T1 brain MRI volume images. Methods: In total, 154 T1-weighted MRIs of healthy subjects (55-83 years of age) were collected from an East Asian community. The information of age, gender, and education level was collected for each participant. The MRIs of the participants were preprocessed using FreeSurfer(https://surfer.nmr.mgh.harvard.edu/) to collect the brain volume data. We trained the models using different supervised machine learning regression algorithms from the scikit-learn (https://scikit-learn.org/) library. Results: The trained models comprised 19 features that had been reduced from 55 brain volume labels. The algorithm BayesianRidge (BR) achieved a mean absolute error (MAE) and r squared (R2) of 3 and 0.3 years, respectively, in predicting the age of the new subjects compared to other regression methods. The results of feature importance analysis showed that the right pallidum, white matter hypointensities on T1-MRI scans, and left hippocampus comprise some of the essential features in predicting brain age. Conclusions: The MAE and R2 accuracies of the BR model predicting brain age gap in the East Asian population showed that the model could reduce the dimensionality of neuroimaging data to provide a meaningful biomarker for individual brain aging.

Gd-Complexes of DTPA-bis(amides) Functionalized by Pyridine and Picolinamide: Synthesis, Thermodynamic Stability, and Relaxivity Properties

  • Sk, Nasiruzzaman;Park, Ji-Ae;Chang, Yong-Min;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.1211-1216
    • /
    • 2008
  • A series of DTPA-bis(amides) functionalized by pyridine (1a-c) and N-phenylpicolinamide) (1d-e) and their Gd(III)-complexes of the type [Gd(1)($H_2O$)]·x$H_2O$ (2a-e) were prepared and characterized by analytical and spectroscopic techniques. Potentiality of 2a-e as contrast agents for magnetic resonance imaging (MRI CA) was investigated by measuring relevant physicochemical properties and relaxivities and compared with [Gd(DTPA-BMA)($H_2O$)] (DTPA-BMA=N,N''-di(methylcarbamoylmethyl)diethylenetriamine-N,N',N''-triacetate) ($Omniscan^{(R)}$). The R1 relaxivities of aqueous solutions of 2a-c are in the range of 3.33 -5.02 $mM^{-1}$$sec^{-1}$, which are comparable with those of $Omniscan^{(R)}$ (r1=4.58 $mM^{-1}sec^{-1}$). Complexes 2d-e, insoluble in water, exhibit relatively higher R1 values (8.1- 8.3 $mM^{-1}sec^{-1}$) in HP-$\beta$-CD solutions.

Prognostic value of $^{18}F$-fluorodeoxyglucose positron emission tomography, computed tomography and magnetic resonance imaging in oral cavity squamous cell carcinoma with pathologically positive neck lymph node

  • Jwa, Eunjin;Lee, Sang-Wook;Kim, Jae-Seung;Park, Jin Hong;Kim, Su Ssan;Kim, Young Seok;Yoon, Sang Min;Song, Si Yeol;Kim, Jong Hoon;Choi, Eun Kyung;Ahn, Seung Do
    • Radiation Oncology Journal
    • /
    • v.30 no.4
    • /
    • pp.173-181
    • /
    • 2012
  • Purpose: To evaluate the prognostic value of preoperative neck lymph node (LN) assessment with $^{18}F$-fluorodeoxyglucose positron emission tomography ($^{18}F$-FDG PET), computed tomography (CT), and magnetic resonance imaging (MRI) in oral cavity squamous cell carcinoma (OSCC) patients with pathologically positive LN. Materials and Methods: In total, 47 OSCC patients with pathologically positive LN were retrospectively reviewed with preoperative $^{18}F$-FDG PET and CT/MRI. All patients underwent surgical resection, neck dissection and postoperative adjuvant radiotherapy and/or chemotherapy between March 2002 and October 2010. Histologic correlation was performed for findings of $^{18}F$-FDG PET and CT/MRI. Results: Thirty-six (76.6%) of 47 cases were correctly diagnosed with neck LN metastasis by $^{18}F$-FDG PET and 32 (68.1%) of 47 cases were correctly diagnosed by CT/MRI. Follow-up ranged from 20 to 114 months (median, 56 months). Clinically negative nodal status evaluated by $^{18}F$-FDG PET or CT/MRI revealed a trend toward better clinical outcomes in terms of overall survival, disease-free survival, local recurrence-free survival, regional nodal recurrence-free survival, and distant metastasis-free survival rates even though the trends were not statistically significant. However, there was no impact of neck node standardized uptake value ($SUV_{max}$) on clinical outcomes. Notably, $SUV_{max}$ showed significant correlation with tumor size in LN (p < 0.01, $R^2$ = 0.62). PET and CT/MRI status of LN also had significant correlation with the size of intranodal tumor deposit (p < 0.05, $R^2$ = 0.37 and p < 0.01, $R^2$ = 0.48, respectively). Conclusion: $^{18}F$-FDG PET and CT/MRI at the neck LNs might improve risk stratification in OSCC patients with pathologically positive neck LN in this study, even without significant prognostic value of $SUV_{max}$.

Gd-complexes of DTPA-bis(amide) Conjugates of Phosphonated Tranexamic Esters as MRI Contrast Agents

  • Patel, Mehul A.;Kim, Hee-Kyung;Lee, Gang-Ho;Chang, Yong-Min;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.1022-1026
    • /
    • 2011
  • The syntheses of DTPA-bis(amide) conjugates of phosphonated cyclohexane moieties (5a-d) and their Gd(III) complexes of the type $[Gd(L)(H_2O)]{\cdot}nH_2O$ (6a-d; L = 5a-d) are described. All new compounds have been characterized by microanalysis and spectroscopic techniques. High $r_1$ relaxivities of aqueous solutions of 6a-d are observed to be in the range of $10.7-18.3\;mM^{-1}sec^{-1}$, which compare much better than that of $Omniscan^{(R)}$ ($r_1=3.90\;mM^{-1}sec^{-1}$).

The Relationship between Image Parameters and SAR for Each Sequence of MRI (MRI 검사의 시퀀스 별 영상 변수와 SAR의 관계)

  • Seong-Ho Kim;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1133-1138
    • /
    • 2023
  • This study analyzed the relationship between image parameters and specific absorption rate (SAR) in various sequence environments to optimize SAR. For this purpose, image parameters were adjusted for T2, T1, STIR, T1 FLAIR, and T2 FLAIR sequences in a 3.0T MRI, and the whole body (WB) SAR and head SAR calculated by the device were measured. Then, the SAR was evaluated by adjusting the number of images and the flip angle (FA) of the refocusing RF. As a result, SAR increased as the number of image increased in all sequences. T1 and T1 FLAIR had correlation coefficients (r) of 0.876, 0.876 (WB SAR, head SAR), 0.867, 0.867 (WB SAR, head SAR), respectively, and STIR had the highest correlation with 0.898 and 0.899 (WB SAR, head SAR). showed (p<0.05). When applied by increasing the refocusing FA, WB SAR and head SAR increased overall in all sequences. The T1 and T2 sequences showed high correlation with correlation coefficients (r) of 0.897, 0.898 (WB SAR, head SAR) and 0.914, 0.915 (WB SAR, head SAR), respectively, while the sequences to which the inversion recovery technique was applied had relatively low FA, showed less sensitivity to increase. Therefore, in a sequence with a relatively low TR, minimizing the number of image and applying the fast spin echo to reduce the refocusing FA in a sequence with a high duty cycle are effective in reducing SAR.