• Title/Summary/Keyword: R134A

검색결과 669건 처리시간 0.033초

R32/125/134a를 사용한 오리피스 팽창장치의 성능실험 및 모델링 (Experimentation and Modeling of R32/125/134a Flow Through Short Tube Orifices)

  • 김용찬
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.45-54
    • /
    • 1996
  • An experimental investigation on the two-phase flow through tube orifices was performed with the refrigerant mixture of R32/125/134a(30/10/60). A series of tests were conducted to generate wide range of data at varying operation conditions with four short tubes. The tests include both single and two-phase flow conditions at the inlet of the short tube with different oil concentrations. Experimental data were presented as a function of major operating parameters and short tube diameter. Based on test results and data analysis, a semi-empirical flow model was developed to predict the mass flow rate through short tube orifices with a given set of conditions. The flow model was formed to cover both single and two-phase flow at the inlet of short tube with considering the effects of oil concentration.

  • PDF

Characteristics of R-22 and R-134a Two-Phase Flow Vaporization in Horizontal Small Tubes

  • Choi, Kwang-Il;Pamitran, A.S.;Rifaldi, M.;Mun, Je-Cheol;Oh, Jong-Taek
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1528-1535
    • /
    • 2009
  • Characteristics of R-22 and R-134a two-phase vaporization in horizontal small tubes were investigated experimentally. In order to obtain the local heat transfer coefficients, the test was ran under heat flux range of 10 to $40\;kW/m^2$, mass flux range of 200 to $600\;kg/m^2s$, saturation temperature range of 5 to $10^{\circ}C$, and quality up to 1.0. The test section, which was made of stainless steel tube and heated uniformly by applying an electric current to the tube directly, have inner tube diameters of 0.5, 1.5 and 3.0 mm, and lengths of 0.33 and 2.0 m. The effects on heat transfer coefficient of mass flux, heat flux and inner tube diameter were presented. The experimental heat transfer coefficients were compared with the predictions using existing heat transfer coefficient correlations. A new boiling heat transfer coefficient correlation based on the superposition model, with considering the laminar flow, was developed.

  • PDF

Development of Species-specific PCR Primers for Detecting Peptoniphilus mikwangii

  • Park, Soon-Nang;Lee, Junhyeok;Kook, Joong-Ki
    • International Journal of Oral Biology
    • /
    • 제42권3호
    • /
    • pp.143-147
    • /
    • 2017
  • In a previous study, Peptoniphilus mikwangii was isolated from the human oral cavity as a new species. The purpose of this study was to develop P. mikwangii-specific PCR primers. The PCR primers were designed, based on the nucleotide sequence of 16S ribosomal RNA (16S rDNA). The specificity of the primers was tested using genomic DNAs of 3 strains of P. mikwangii and 27 strains (27 species) of non-P. mikwangii bacteria. The sensitivity of primers sensitivity was determined using PCR, with serial dilutions of the purified genomic DNAs (4 ng to 4 fg) of P. mikwangii KCOM $1628^T$. The data showed that P. mikwangii-specific qPCR primers (B134-F11/B134-R1 & B134-F5/B134-R5) could detect only P. mikwangii strains, and 400 fg or 40 fg of P. mikwangii genome DNA. These results suggest that PCR primers are useful in detecting P. mikwangii from the oral cavity.

Performance Test of a R134a Centrifugal Water Chiller

  • Jeong, Jin-Hee;Yoon, Pil-Hyun;Kim, Ghil-Yeung;Lee, Hyeon-Koo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권2호
    • /
    • pp.97-105
    • /
    • 2002
  • A centrifugal water chiller using alternative refrigerant R134a has been developed. The prototype was designed to have refrigerating capacity of 300RT. Its compressor employs a single high-speed impeller, airfoil diffuser and collector. Newly developed, enhanced tubes were installed in the evaporator and the condenser to reduce the required head for the compressor. Off-design characteristics at various conditions, performance test of the compressor and analysis of the refrigeration cycle were performed. So the probability of use in part load condition was checked and the direction for revision was suggested.

R134a를 이용한 냉동장치의 성능특성에 관한 실험적 연구 (An Experimental Study on Performance Characteristics of Refrigeration System Using R134a Refrigerating System)

  • 김진현;김종길;김성배;하옥남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2188-2193
    • /
    • 2007
  • Since the use of CFCs and HCFCs refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the R134a gas to study the performance characteristic from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1.5 MPa to 1.6 MPa by 0.05 MPa and for superheat temperature from 0$^{\circ}C$ to 5$^{\circ}C$ by 1$^{\circ}C$ at each condensing pressure. As a result of experiment, when the superheat temperature is 1$^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.

  • PDF

태양열 이용 비프레온계 $CF_3CH_2F$(R-134a)적용 열펌프시스템에 의한 학교교실 난방에 관한 연구(II) (The performance of solar heat pump with non-freon refrigerant $CF_3CH_2F$(R-134a) for school classroom heating[II])

  • 선경호;정현채;김기선
    • 태양에너지
    • /
    • 제17권1호
    • /
    • pp.3-15
    • /
    • 1997
  • 본 연구는 R-12($CF_2Cl_2F$) 대체냉매인 R-134a($CF_3CH_2F$) 적용 태양열 열펌프시스템에 의하여 학교교실($20{\sim}25$평형)이나 학교 화장실($13{\sim}17$평형)의 난방에 관한 것으로서 대체냉매 적용할 때 시스템의 안정성과 성능에 관해 실험되어졌다. 학교교실 난방을 위한 방법 중에서 온풍난방을 택하여 실험하였는데 대체냉매 적용 실제와 모형시스템의 난방성능을 비교 해석하였다. 이 결과를 근거로 R-22($CHClF_2$)와 그 대체냉매들에 대한 성능을 예측하였다. 서울지방 봄 가을철, 겨울철의 외기 온도에서 실내온도가 $18{\sim}20^{\circ}C,\;23{\sim}25^{\circ}C$로 유지할 수 있도록 설계 제작되었다.

  • PDF

다양한 냉매를 적용한 초임계 히트펌프의 성능 비교 (Performance Comparison of Supercritical Heat Pump for a Variety of Refrigerants)

  • 윤정인;손창효;최광환;전민주
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.42-47
    • /
    • 2014
  • In this paper, the cycle performance analysis for the COP of supercritical heat pump using various refrigerants is presented to offer the basic design data for the operating parameters of the system. The working fluids are R134a, R22, R32, R290, R600, R600a, R1270 and R744. The operating parameters considered in this study include superheating degree of evaporator, temperature of gas cooler inlet and outlet, compressor efficiency and evaporating temperature in the supercritical heat pump system. The main results were summarized as follows : Superheating degree, temperature of gas cooler inlet and outlet, compressor efficiency and evaporating temperature of supercritical heat pump system have an effect on the COP of this system. With a thorough grasp of these effect, it is necessary to design the supercritical heat pump using R134a. And, in comparison of COP of supercritical heat pump using various refrigerants, R32 and R600 is the highest, and R744 is the lowest among other refrigerants. From these results, it is confirmed that the COP of supercritical heat pump using R744 is higher than that using freon refrigerants such as R32 and R134a.

미세휜관내 윤활유를 포함한 대체냉매의 압력강하 예측에 관한 연구 (Study on the Prediction of Pressure Drop for Alternative Refrigerants with lubricant in Micro-Fin Tubes)

  • 최준영;이진호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.83-89
    • /
    • 2000
  • This paper presents a pressure drop correlation for evaporation and condensation of alternative refrigerant with oil in micro-fin tubes. The correlation was developed from a data base consisting of oil-free pure and mixed refrigerants in micro-fin tube; Rl25 R134a. R32 R410a(R32/R125 50/50% mass), R22, R407c(R32/R125/R134a, 23/25/52% mass) and R32/R134a(25/75% mass). The micro-fin tube used in this paper had 60 0.2mm high fins with a 18 helix angle. The cross sectional flow area $(A_c)$ was $60.8 mm^2$ giving an equivalent smooth diameter$(D_e)$ of 8.8mm. The hydraulic diameter $(D_h)$ was estimated to the 5.45mm. The new correlation was obtained by replacing the friction factor and the tube-diameter in Bo Pierre correlation by a friction factor derived from pressure drop data for a micro-fin tube and the hydraulic diameter, respectively. This correlation was also used to predict some pressure data with a lubricant after using a mixing viscosity rule of lubricants and refrigerants. As a result, the new correlation was also well predicted to the measured data within a mean deviation of 19.0%.

  • PDF

삼차원 조도를 가진 성형가공관의 R-134a 풀비등 열전달 촉진에 관한 실험적 연구 (An Experimental Study on Pool Boiling Heat Transfer Enhancement of Structured Tubes Having Three-Dimensional Roughness)

  • 김내현
    • 설비공학논문집
    • /
    • 제28권5호
    • /
    • pp.195-201
    • /
    • 2016
  • Enhanced tubes are widely used in air-conditioning and process industries. Structural tubes having three-dimensional roughness are well known to be able to significantly enhance pool boiling heat transfer of refrigerants. In this study, five structural enhanced tubes having different fin density, fin height, and fin gap width were tested using R-134a. Results showed that the heat transfer coefficient was increased with increased fin density. Within test range, the effect of fin height on pool boiling heat transfer coefficient was insignificant. The heat transfer coefficients of the optimum configuration (2047 fpm, 0.21 mm gap width) tube were lower than those of other commercial enhanced tubes. This might be due to the larger fin gap width of the present enhanced tube.