• Title/Summary/Keyword: R-test

Search Result 10,625, Processing Time 0.043 seconds

Comparison of the Results of Multistix$^{(R)}$SG and Comber-9-Test$^{(R)}$ RL Urine Dipstick Assay (Multistix$^{(R)}$-SG와 Comgur-9-test$^{(R)}$RL에 의한 요시험지봉검사 성적의 비교)

  • Kim, Dae-Chul;Kim, Kyung-Dong;Jung, Bo-Chan;Kim, Chung-Sook;Cho, Kil-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.42-52
    • /
    • 1991
  • Two types of urine dipstick assays, Multistix-SG and Combur-9-test RL, were compared for compatibility, accuracy, specificity and predictive values of a positive and negative test in 501 patients urine and artificially prepared specimen. We found that the results of semiquantitative tests of Multistix-SG and Combur-9-Test RL performed were statistically similar in patients specimen. The urinary leukocyte estrase tests of Combur-9-Test RL assays compared with urine sediment microscopy in regard to compatibility, sensitivity, specificity, and predictive values of a positive and negative test 83.7%, 48.1%, 90.3%, 47.4% and 90.1%, respectively. The urinar nitrite tests of Comber-9-Test RL assays compared with urine culture tests, in regard to compatibility, sensitivity, specificity, and predictive values of a positive and negative tests were 90.3%, 19.4%, 84.7%, 53.8% and 94.1%, respectively. For the urinary protein, the sulfosalicylic acid method was the most sensitive test for any kinds of protein, and Multistix-SG appeared more sensitive than Compur-9-Test RL for the albuminuria. For the urinary bilirubin and glusose, two dipstick assays were similar in their diganostic efficiency. Finally in the urinary occult blood tests, Combur-9-Test RL assays was more sensitive than Multistix-SG.

  • PDF

Alternative Method of Determining Resilient Modulus of Subbase Materials Using Free-Free Resonant Column Test (현장공진주시험을 이용한 보조기층 재료의 대체 $M_R$ 시험법)

  • Kweon, Gi-Cheol;Kim, Dong-Su
    • International Journal of Highway Engineering
    • /
    • v.2 no.2
    • /
    • pp.149-161
    • /
    • 2000
  • The stiffness of the subbase materials is represented by the resilient modulus, $M_R$, which are very important properties in the mechanistic design of flexible pavement system. However, the cyclic $M_R$ testing method is too complex, expensive, and time consuming to be applicable on a production basis. In this study, the alternative $M_R$ testing technique for subbase materials was developed using a free-free resonant column (FF-RC) test considering deformational characteristics of subbase materials. To estimate the deformational characteristics of subbase materials, effects of strain amplitude and mean effective stress on modulus of subbase materials were investigated. The $M_R$ values determined by alternative testing procedures matched well with those determined by standard $M_R$ test, showing the capability of the proposed methods being used in determining $M_R$ values.

  • PDF

Performance Analysis of an ORC System for Two Different Working Fluids (두 종류의 다른 작동유체가 ORC 시스템의 성능에 미치는 영향)

  • Chang, Hong-Soon;Song, Yeong-Kil;Han, Young-Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.413-417
    • /
    • 2013
  • The organic Rankine Cycle (ORC) uses a kind of refrigerant as a working fluid that evaporates at relatively low temperature, as the Rankine Cycle uses superheated steam as the working fluid. A small scale ORC test bench was installed, and two different working fluids (R245fa and R134a) were injected into the test bench. The test bench was in operation with the two different working fluids under the same conditions. The effects against the system performance from the different working fluids were analysed, and root causes were identified. Other factors reflecting the power generation efficiency were also found. A conclusion was drawn, that R245fa makes the system perform better, than R134a.

Analysis of Apparatus Variables for Deformation Strength Test of Asphalt Concrete Based on Correlation with Rutting and Prediction Model for Rutting (소성변형과의 상관성 및 추정모델을 통한 변형강도 시험장치 변수 분석)

  • Kim, Kwang-Woo;Lee, Moon-Sup;Kim, Sung-Tae;Lee, Soon-Jae
    • International Journal of Highway Engineering
    • /
    • v.4 no.4 s.14
    • /
    • pp.41-52
    • /
    • 2002
  • This study dealt with analysis of size effect of testing apparatus for Kim test which measures rut resistance characteristics of asphalt mixture under static loading. Two columns in different diameter with each column having different radios of round cut (Curvature) at the bottom were used for testing asphalt mixture. Deformation load ($P_{max}$) and deformation strength ($K_D$) were found to have relatively high correlation with rut depth and dynamic stability of asphalt concrete. Diameter of specimen was not a significant factor in this test. From the statistical correlation analysis with rutting properties, the radius of curvature and diameter of loading column were found to be important factor affecting the results of the test. Among the radios (r) of curvatures, r=0.5cm and 1.0cm showed much higher correlation than the column without curvature, and r=1.0cm being better between the two. The column with diameter of 4cm showed better correlation than diameter of 3cm. Therefore, the column of 4cm diameter with r=1.0cm was found to be the best among various apparatus sizes. Prediction models for rut depth and dynamic stability were developed for each aggregate mixture based on Kim test variables using SAS STEPWISE procedure. Therefore, if this test method is validated through further study, Kim test can be used for selecting asphalt mixture with the highest resistance against permanent deformation.

  • PDF

Strengthening Effect Evaluation Technique of R/C Beams using the Vibration Test (진동시험을 통한 R/C Beam의 보강효과 검증기법)

  • 심종성;유태석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.255-260
    • /
    • 1994
  • This study suggests a strengthening effect evaluation technique of reinforced concrete beams using the vibration test. To evaluate the strengthening effect of R/C beams, Strengthening Factor(Sf) was suggested. Using the value of Sf, 20 beams were evaluated. According to these results the effects of R/C beams strengthened by steel plate is superior than those of R/C beams strengthened by carbon fiber sheet.

  • PDF

REVIEW OF DYNAMIC LOADING J-R TEST METHOD FOR LEAK BEFORE BREAK OF NUCLEAR PIPING

  • Oh, Young-Jin;Hwang, Il-Soon
    • Nuclear Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.639-656
    • /
    • 2006
  • In order to apply the leak before break (LBB) concept to nuclear piping systems, the dynamic strain aging effect of low carbon steel materials has to be taken into account, in compliance with the requirements of the Korean Standard Review Guide (KSRG) 3.6.3-1. For this goal, J-R tests are needed for a range of various temperatures and loading rates, including dynamic loading conditions. In the dynamic loading J-R test, the unloading compliance method can not be applied to measure the crack growth and direct current potential drop (DCPD) method; this method also has a problem defining the crack initiation point. The normalization method is known as a very useful method to determine the J-R curve under dynamic loading because it does not need additional equipment or complicated loading sequences such as electric current or unloading. This method was accepted by the American Society for Testing and Materials (ASTM) as a standard test method E1820 A15 in 2001. However, it has not yet been clearly verified yet if the normalization method is sufficiently reliable to be applied to LBB. In this study, the basic background of the J-integral, LBB and dynamic loading J-R test are explained, and the current status for dynamic loading J-R test methods are reviewed from the view point of LBB for nuclear piping. In particular, the theoretical and historical background of the normalization method which has received attention recently, is summarized. Recent studies for this method are introduced and future works are suggested that may improve the reliability of LBB for nuclear piping.

Application of deep learning technique for battery lead tab welding error detection (배터리 리드탭 압흔 오류 검출의 딥러닝 기법 적용)

  • Kim, YunHo;Kim, ByeongMan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.27 no.2
    • /
    • pp.71-82
    • /
    • 2022
  • In order to replace the sampling tensile test of products produced in the tab welding process, which is one of the automotive battery manufacturing processes, vision inspectors are currently being developed and used. However, the vision inspection has the problem of inspection position error and the cost of improving it. In order to solve these problems, there are recent cases of applying deep learning technology. As one such case, this paper tries to examine the usefulness of applying Faster R-CNN, one of the deep learning technologies, to existing product inspection. The images acquired through the existing vision inspection machine are used as training data and trained using the Faster R-CNN ResNet101 V1 1024x1024 model. The results of the conventional vision test and Faster R-CNN test are compared and analyzed based on the test standards of 0% non-detection and 10% over-detection. The non-detection rate is 34.5% in the conventional vision test and 0% in the Faster R-CNN test. The over-detection rate is 100% in the conventional vision test and 6.9% in Faster R-CNN. From these results, it is confirmed that deep learning technology is very useful for detecting welding error of lead tabs in automobile batteries.

Compatibility for Proposed R.94 PDB Test (PDB 시험에 대한 충돌 상호 안전성)

  • Jang, Eun-Ji;Kim, Joseph;Beom, Hyen-Kyun;Kwon, Sung-Eun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.3
    • /
    • pp.149-155
    • /
    • 2010
  • Currently various safety tests are being performed in many countries with growing interest in vehicle safety. However the vehicles which have good safety performance in these tests could not secure the good performance in real car to car accident. So new test protocol using progressive deformable barrier (PDB) was proposed by EEVC in Europe, NHTSA in USA and some vehicle manufacturers, etc. The target of PDB test is to control partner protection in addition to self-protection on the same test. The proposal is to update current ECE R.94 frontal ODB test. So barrier, impact speed, overlap are changed to avoid bottoming-out in the test configuration. In this paper 3 different tests (R.94, EuroNCAP and PDB test) were carried out using current production vehicles with same structure. The results of these tests were compared to understand PDB test. As a result PDB test shows the highest vehicle deceleration and dummy injury because PDB offers a progressive increase in stiffness in depth and height. However vehicle intrusion was affected with rather test velocity than stiffness of deformable barrier. PDB deformation data is used for partner protection assessment using PDB software and it shows that the test vehicle is rather not aggressive.

Effects of Refrigerant Oils and Molecular Sieve on Air Conditioner using Alternative Refrigerant (대체냉매를 사용한 에어콘에서 합성오일과 건조제(M/S)의 영향)

  • Choa, S.H.;Hong, C.K.;Kim, C.K.;Yoon, B.;Kang, S.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.473-483
    • /
    • 1996
  • To protect the ozone layer, R22 will be replaced with HFCs. R407C is a leading candidate as alternative refrigerant for air conditioner due to its similar thermodynamic characteristics with R22. In replacing R22 with R407C, the compatibility with lubricating oil is of major concern. Polyol ester (POE) oil among the synthetic oils is considered to be the best lubricant for use with R407C because of good electrical properties and miscibility. However, lubricating ability of mixture of R407C/POE oil is lower than that of R22/mineral oil due to the production of acid by hydrolysis which causes corrosive wear. Therefore, to minimize water content, it is needed to develop a molecular sieve desiccant which is compatible with R407C and ester oil. This paper discusses (1) the change of properties of POE oil when current molecular seive is used, (2) the effects of POE oils and additives on durability of compressor. Through compressor life test and bench wear test, it was found that inadequate use of POE oils and additives may promote the deteriation of molecular sieve, resulting in decrease of durability of compressor.

  • PDF