• 제목/요약/키워드: R-phase

검색결과 3,487건 처리시간 0.042초

Integration of Headspace Solid Phase Micro-Extraction with Gas Chromatography for Quantitative Analysis of Formaldehyde

  • Lo, Kong Mun;Yung, Yen Li
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권1호
    • /
    • pp.139-142
    • /
    • 2013
  • A study was carried out to evaluate the solid phase micro-extraction (SPME) for formaldehyde emission analysis of uncoated plywood. In SPME, formaldehyde was on-fiber derivatized through headspace extraction and analyzed by gas chromatography coupled with mass spectrometry (GC/MS). The SPME was compared with desiccators (DC-JAS 233), small-scale chamber (SSC-ASTM D6007) and liquid-liquid extraction (LLE-EPA 556) methods which were performed in accordance with their respective standards. Compared to SSC (RSD 4.3%) and LLE (RSD 5.0%), the SPME method showed better repeatability (RSD 1.8%) and not much difference from DC (RSD 1.4%). The SPME has proven to be highly precise (at 95% confidence level) with better recovery (REC 102%). Validation of the SPME method for formaldehyde quantitative analysis was evidenced. In addition, the SPME by air sampling directly from plywood specimens (SPME-W) correlated best with DC ($r^2$ = 0.983), followed by LLE ($r^2$ = 0.950) and SSC ($r^2$ = 0.935).

Membrane-Attached Biofilm Reactor(MABR)에서의 독립영양 미생물을 이용한 질소 제거 (Nitrogen Removal using Autotrophic Microorganism in Membrane-Attached Biofilm Reactor (MABR))

  • 신정훈;상병인;정윤철;정연규
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.624-629
    • /
    • 2005
  • The purpose of this study is to investigate the performance of nitrogen removal using autotrophic microorganism in the Membrane-Attached Biofilm Reactor (MABR). The treatment system consists of an aerobic MABR (R1) for nitrification and an anaerobic MABR (R2) for hydrogenotrophic denitrification. Oxygen and hydrogen were supplied through the lumen of hollow-fiber membranes as electron acceptor and donor, respectively. In phase Ι, simultaneous organic carbon removal and nitrification were carried out successfully in R1. In phase II, to develop the biofilm on the hollow-fiber membrane surface and to acclimate the microbial community to autotrophic condition, R1 and R2 were operated independently. The MABRs, R1 and R2 were connected in series continuously in phase III and operated at HRT of 8 hr or 4 hr with $NH_4{^+}-N$ concentration of influent, from 150 to 200 mgN/L. The total nitrogen removal efficiency reached the maximum value of 99% at the volumetric nitrogen loading rate of $1.20kgN/m^3{\cdot}d$ in the combined MABR system with R1 and R2. The results in this study demonstrated that the combined MABR system could operate effectively for the removal of nitrogen in wastewater not containing organic materials and can be used stably as a high rate nitrogen removal technology.

Physico-Chemical Properties of Pseudoceramide in Relation to Bilayer-Forming

  • Jeong, Min-Woo;Oh, Seong-Geun;Kim, Do-Hoon;Kang, Hak-Hee
    • 대한화장품학회지
    • /
    • 제27권1호
    • /
    • pp.3-15
    • /
    • 2001
  • The bilayer forming ability of pseudo-ceramide PC104 in octanoic acid/water/n-octyl $\beta$-D-glucoside mixtures was investigated through the phase diagram. Because of its low solubility in water and of its crystallization, pseudoceramide PC104 was dissolved in octanoic acid, which is nontoxic additive for foods and cosmetics. The mixtures formed four different phases (L1, L2, LC and two phases). Depending on the concentration of PC104 in octanoic acid, the region of each phase was extended or contracted. On the contrary to the region of L2, regions of lamellar phase and L1 phase were expanded. The bilayer-forming ability of PC104 was explained on the basis of concentration of PC104 at interface and interaction between PC104 and octanoic acid. From FT-IR results, it was found that the interactions of PC104’s polar head group with octanoic acid increased as the amount of PC104 in octanoic acid increased. Also emulsion size and size distribution have been studied depending upon the emulsification path. droplets of emulsion prepared from lamellar phase were smaller and more homogeneous compared to those of emulsions formed from L2 phase.

  • PDF

Two-Phase Flow Distribution and Phase Separation Through Both Horizontal and Vertical Branches

  • Tae, Sang-Jin;Keumnam Cho
    • Journal of Mechanical Science and Technology
    • /
    • 제17권8호
    • /
    • pp.1211-1218
    • /
    • 2003
  • The present study investigated two-phase flow distribution and phase separation of R-22 refrigerant through various types of branch tubes. The key experimental parameters were the orientation of inlet and branch tubes (horizontal and vertical), diameter ratio of branch tube to inlet tube (1 and 0.61), mass flux (200-500 kg/㎡s), and inlet quality (0.1-0.4). The predicted local pressure profile in the tube with junction was compared and generally agreed with the measured data. The local pressure profile within the pressure recovery region after the junction has to be carefully investigated for modeling the pressure drop through the branch. The equal flow distribution case can be found by adjusting the orientation of the inlet and branch tubes and the diameter ratio of the branch tube to the inlet tube. The T-junction with horizontal inlet and branch tubes showed the nearly equal phase distribution ratio. The quality at the branch tube varied from 0 to 1 as the orientation of the branch tube changed, while it varied within${\pm}$50% as the orientation of the inlet tube changed.

계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어 (An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition)

  • 박태현;김학원;조관열;민준기;최원일
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

The Method of Reducing Echo Time in 3D Time-of-flight Angiography

  • Park, Sung-Hong;Park, Jung-Il;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.367-369
    • /
    • 2002
  • We have designed ramp profile excitation pulse based on the Shinnar-Le Roux (SLR) algorithm. The algorithm provides many advantages to pulse designers. The first advantage is the freedom of deciding the amplitudes, frequencies, and ripple sizes of stopband, passband, and transition band of pulse profile. The second advantage is the freedom of deciding the pulse phase, more specifically, minimum phase, linear phase, maximum phase, and any phase between them. The minimum phase pulse is the best choice in the case of 3D TOF, because it minimizes the echo time, which implies the best image quality in the same MR examination condition. In addition, the half echo technique is slightly modified in our case. In general, using the half echo technique means that the acquired data size is half and the rest part can be filled with complex conjugate of acquired data. But in our case, the echo center is just shifted to left, which implies the reduction of echo time, and the acquired data size is the same as the one without using the half echo technique. In this case, the increase of right part of data leads to improvement of the resolution and the decrease of left part of data leads to decrease of signal to noise ratio. Since in the case of 3D TOF, the signal to noise ratio is sufficiently high and the resolution is more important than signal to noise ratio, the proposed method appears to be significantly affective and gives rise to the improved high resolution angiograms.

  • PDF

인터페로미터 방향 탐지기의 디지털 위상차 측정 기법 성능 분석 (Performance Analysis on Digital Phase Difference Measurement Techniques for Interferometer Direction Finder)

  • 강종진;박성균;노지현
    • 한국정보통신학회논문지
    • /
    • 제22권8호
    • /
    • pp.1076-1082
    • /
    • 2018
  • 본 논문은 서로 다른 안테나로부터 수신되는 무선 신호의 위상차를 계산하여 신호의 도래방향을 측정하는 인터페로미터 방향 탐지 장치에 관한 것이다. 최신의 전자전용 방향 탐지기는 위상차 측정에 있어서 온도에 따른 위상측정 편차가 작고, 낮은 신호 대 잡음비 환경 에서도 비교적 위상측정 성능이 우수한 디지털 위상차 측정 방법이 적용되고 있다. 시스템에서 요구되는 방향 탐지 정확도 성능 달성을 위한 위상차 측정 허용 오차를 도출하고, 디지털 위상차 측정 방법에 대하여 소개하였다. 샘플 개수, 신호 대 잡음비, 간섭신호 유입에 따른 성능을 정량적으로 분석하였고, 시뮬레이션을 통하여 주파수 영역 측정방법이 시간영역 대비 낮은 SNR 및 간섭신호 유입 환경에서 더 좋은 성능을 보임을 확인하였다. 제안한 방법은 인터페로미터 방향 탐지 장치의 성능 결정에 활용 할 수 있을 것이다.

고속전철용 단상 PWM 컨버터에 관한 연구 (A Single Phase PWM Converter for High Speed Traction System)

  • 김연준;김두식;이현원;서광덕;김남해
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.630-633
    • /
    • 1997
  • This paper describes a design of a single phase PWM converter for high speed train. Parallel operation and control method of four Quadrant PWM converters are described. Simulation and modelling of the converters is performed. Capacity of the converter/inverter and power circuit for high speed traction system designed. And harmonic contents of AC line current's are analyzed. The results of the simulation are presented.

  • PDF

세관내 HCFC계 대체냉매의 압력강하에 관한 연구 (The Pressure Drop Characteristics in Small Diameter Tubes Using HCFC Alternative Refrigerants)

  • 손창효;이호림;정진호;최영석;오후규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.347-352
    • /
    • 2000
  • The pressure drop characteristics of R-22 and R-410A(a mixture of 50wt% R-32 and 50wt% R-125) flowing in a small diameter tube with 1.77[mm] inner diameter and 3.14[mm] outer diameter was investigated experimentally. the mass fluxes of refrigerants are ranged from 450 to $1050[kg/(m^2{\cdot}s)]$ and the qualites are varied from 0.05 to 0.95. The main experimental results were summarized as follows; The single-phase liquid friction factors for small diameter tubes are higher than those predicted by the Blasius equation. In case of two-phase flow, the pressure gradient of the small diameter tube increases with increasing mass velocity and vapor quality. The experimental data are not well correlated by predictions which were proposed for the large diameter tube.

  • PDF

확률적 수요하에서의 자동창고의 필요 저장능력 추정 (Storage Capacity Estimation for Automated Storage/Retrieval Systems under Stochastic Demand)

  • 조면식
    • 대한산업공학회지
    • /
    • 제27권2호
    • /
    • pp.169-175
    • /
    • 2001
  • Most of studies on automated storage/retrieval (AS/R) system assumed that storage capacity is given, although it is a very important decision variable in the design phase. We propose a simple algorithm to estimate the required storage capacity, i.e., number of aisles and number of openings in vertical and horizontal directions in each aisle, of an AS/R system under stochastic demand, in which storage requests occur endogenously and exogenously while the retrieval requests occur endogenously from the machines. Two design criteria, maximum permissible overflow probability and maximum allowable storage/retrieval (S/R) machine utilization, are used to compute the storage capacity. This model can be effectively used in the design phase of new AS/R systems.

  • PDF