• Title/Summary/Keyword: R-Peak

Search Result 1,514, Processing Time 0.027 seconds

DYNAMICAL CHARACTERISTICS OF SUNSPOT CHROMOSPHERES II. ANALYSIS OF CA II H, K AND ${\lambda}8498$ LINES OF A SUNSPOT (SPO 5007) FOR OSCILLATORY MOTIONS

  • Yoon, Tae-Sam;Yun, Hong-Sik;Kim, Jeong-Hoon
    • Journal of The Korean Astronomical Society
    • /
    • v.28 no.2
    • /
    • pp.245-253
    • /
    • 1995
  • We have analyzed the time series of Ca II H,K and ${\lambda}8498$ line profiles taken for a sunspot (SPO 5007) with the Echelle spectrograph attached to Vacuum Tower Telescope at Sacramento Peak Solar Observatory. Each set of spectra was taken simultaneously for 20 minutes at a time interval of 30 seconds. A total of 40 photographic films for each line was scanned by a PDS at Korea Astronomy Observatory. The central peak intensity of Ca II H ($I_{max}$), the intensity measured at ${\Delta}{\lambda}=-0.1{\AA}$ from the line center of ${\lambda}8498(I_{{\lambda}8489})$, the radial velocity ($V_r$) and the Doppler width (${\Delta}{\lambda}_D$) estimated from Ca II H have been measured to study the dynamical behaviors of the sunspot chromosphere. Fourier analysis has been carried out for these measured quantities. Our main results are as follows: (1) We have confirmed the 3-minute oscillation being dominant throughout the umbra. The period of oscillations jumps from 180 sec in the umbra to 500 to 1000 sec in the penumbra. (2) The nonlinear character of the umbral oscillation is noted from the observed sawtooth shaped radial velocity fluctuations with amplitudes reaching up to $5{\sim}6\;km/sec$. (3) The spatial distribution of the maximum powers shows that the power of oscillations is stronger in the umbra than in the penumbra. (4) The spatial distributions of the time averaged < $I_{max}$ > and < $V_r$ > across the spot are found to be nearly axially symmetric, implying that the physical quantities derived from the line profiles of Ca II H and ${\lambda}8498$ are inherently associated with the geometry of the magnetic field distribution of the spot. (5) The central peaks of the CaII H emission core lead the upward motions of the umbral atmosphere by $90^{\circ}$, while no phase delay is found in intensities between $I_{max}$ and $I_{{\lambda}8498}$, suggesting that the umbral oscillation is of standing waves.

  • PDF

Ontogenic Expression of Translocated Purple and Vermilion Genes in Drosophila melanogaster (개체발생에 따른 초파리의 Puple과 Vermilion Gene 발현에 관한 연구)

  • Jeongbin Yim
    • The Korean Journal of Zoology
    • /
    • v.24 no.3
    • /
    • pp.123-131
    • /
    • 1981
  • The purple $(pr^+)$ gene of Drosophila and its associated enzyme, sepiapterin synthase, were employed in a study of the relationship between ontogenic expression and the location of the gene in the genome, Enzyme assays performed at different developmental stages indicate the $T(Y:2)pr^c5, cn/pr^c4 cn$ flies (files in which $pr^+$ has been translocated and which exhibit variegation) have a reduced amount of enzyme activity as compared with both wild-type and $pr^1$ flies. This reduction in activity was not found in larval stages, which suggests that the inactivation process probably occurs in late larval or early pupal stages. Tryptophan pyrrolase, the enzyme system associated with vermilion $(v^+)$, was also examined for activity in different developmental stages of the fly. Genotype carrying a translocated $v^+$ shows a peak of tryptophan pyrrolase activity in late larval stages, whereas, Oregon-R exhibits the lowest activity at this period.

  • PDF

Analysis and Design of a Multi-resonant Converter with a Wide Output Voltage Range for EV Charger Applications

  • Sun, Wenjin;Jin, Xiang;Zhang, Li;Hu, Haibing;Xing, Yan
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.849-859
    • /
    • 2017
  • This paper illustrates the analysis and design of a multi-resonant converter applied to an electric vehicle (EV) charger. Thanks to the notch resonant characteristic, the multi-resonant converter achieve soft switching and operate with a narrowed switching frequency range even with a wide output voltage range. These advantages make it suitable for battery charging applications. With two more resonant elements, the design of the chosen converter is more complex than the conventional LLC resonant converter. However, there is not a distinct design outline for the multi-resonant converters in existing articles. According to the analysis in this paper, the normalized notch frequency $f_{r2n}$ and the second series resonant frequency $f_{r3n}$ are more sensitive to the notch capacitor ratio q than the notch inductor ratio k. Then resonant capacitors should be well-designed before the other resonant elements. The peak gain of the converter depends mainly on the magnetizing inductor ratio $L_n$ and the normalized load Q. And it requires a smaller $L_n$ and Q to provide a sufficient voltage gain $M_{max}$ at ($V_{o\_max}$, $P_{o\_max}$). However, the primary current increases with $(L_nQ)^{-1}$, and results in a low efficiency. Then a detailed design procedure for the multi-resonant converter has been provided. A 3.3kW prototype with an output voltage range of 50V to 500V dc and a peak efficiency of 97.3 % is built to verify the design and effectiveness of the converter.

Elastic floor response spectra of nonlinear frame structures subjected to forward-directivity pulses of near-fault records

  • Kanee, Ali Reza Taghavee;Kani, Iradj Mahmood Zadeh;Noorzad, Assadollah
    • Earthquakes and Structures
    • /
    • v.5 no.1
    • /
    • pp.49-65
    • /
    • 2013
  • This article presents the statistical characteristics of elastic floor acceleration spectra that represent the peak response demand of non-structural components attached to a nonlinear supporting frame. For this purpose, a set of stiff and flexible general moment resisting frames with periods of 0.3-3.6 sec. are analyzed using forty-nine near-field strong ground motion records. Peak accelerations are derived for each single degree of freedom non-structural component, supported by the above mentioned frames, through a direct-integration time-history analysis. These accelerations are obtained by Floor Acceleration Response Spectrum (FARS) method. They are statistically analyzed in the next step to achieve a better understanding of their height-wise distributions. The factors that affect FARS values are found in the relevant state of the art. Here, they are summarized to evaluate the amplification and/or reduction of FARS values especially when the supporting structures undergo inelastic behavior. The properties of FARS values are studied in three regions: long-period, fundamental-period and short-period. Maximum elastic acceleration response of non-structural component, mounted on inelastic frames, depends on the following factors: inelasticity intensity and modal periods of supporting structure; natural period, damping ratio and location of non-structural component. The FARS values, corresponded to the modal periods of supporting structure, are strongly reduced beyond elastic domain. However, they could be amplified in the transferring period domain between the mentioned modal periods. In the next step, the amplification and/or reduction of FARS values, caused by inelastic behavior of supporting structure, are calculated. A parameter called the response acceleration reduction factor ($R_{acc}$), has been previously used for far-field earthquakes. The feasibility of extending this parameter for near-field motions is focused here, suggested repeatedly in the relevant sources. The nonlinearity of supporting structure is included in ($R_{acc}$) for better estimation of maximum non-structural component absolute acceleration demand, which is ordinarily neglected in the seismic design provisions.

3-D Shock Structure of Orion KL Outflow with IGRINS

  • Oh, Heeyoung;Pyo, Tae-Soo;Kaplan, Kyle F.;Koo, Bon-Chul;Yuk, In-Soo;Lee, Jae-Joon;Mace, Gregory N.;Sokal, Kimberly R.;Hwang, Narae;Park, Chan;Park, Byeong-Gon;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.38.3-38.3
    • /
    • 2018
  • We present the results of high-resolution near-IR spectral mapping toward the Orion KL outflow. In this study, we used the Immersion Grating Infrared Spectrometer (IGRINS) on the 2.7 m Harlan J. Smith Telescope at McDonald Observatory. IGRINS's large wavelength coverage over the H & K bands and high spectral resolving power (R ~ 45,000) allowed us to detect over 35 shock-excited ro-vibrational H2 transitions and to measure directly the gas temperature and velocity of the dense outflows. In our previous study toward the H2 peak 1 region in the Orion KL outflow, we identified 31 outflow fingers from a datacube of the H2 1-0 S(1) $2.122{\mu}m$ line and constructed a three-dimensional map of the fingers. The internal extinction (${\Delta}AV$ > 10 mag) and overall angular spread of the flow argue for an ambient medium with a high density (105 cm-3). In this presentation, we show preliminary results of additional mapping toward a remarkable chain of bows (HH 205 - HH 207) farther from the ejection center, and obtain a more clear view of the shock physics of a single isolated bullet that improves on the knowledge gained from observations of the more complex peak 1 region in our earlier study.

  • PDF

Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler (지역난방 첨두부하보일러 대류부 부식 파손 분석)

  • Kim, Youngsu;Chae, Hobyung;Hong, Minki;Song, Min Ji;Cho, Jeongmin;Kim, Woo Cheol;Ha, Tae Baek;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.55-60
    • /
    • 2019
  • Corrosion failure in the convection part of peak load boiler (PLB) of the district heating system led to water leakage. Herein, Internal Rotary Inspection System (IRIS) inspection was employed to examine wall thinning and the cause of leakage in the flue tube. The corrosive products of the turbulator and tube were investigated using scanning electron microscope combined with energy dispersive spectroscopy, X-ray diffraction, and inductively coupled plasma (ICP). Majority of the serious corrosion damage was observed near the turbulator located in the upper flue tube. ICP analysis of the boiler water revealed oxide formation of sodium chloride in the lower end part of the flue tube. A cross-sectional view of the turbulator revealed the presence of double-layers of the oxide film, indicating environmental change during operation associated with water leakage. The outer surface of the turbulator consisted of the acid oxides such as $NO_x$ and $SO_x$ along with sodium and chloride ions. Dew-point corrosion is hypothesized as the main cause for the formation of acid oxides in the region of contact of the flue tube and the turbulator.

Reliability and Validity of an Electronic Inspiratory Loading Device for Assessing Pulmonary Function in Patients with COPD

  • Lee, Seugcheol;You, Seongkwang;Yang, Subin;Park, Daesung
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.1
    • /
    • pp.40-47
    • /
    • 2021
  • Objective: The purpose of this study is to prove the reliability and validity of the Power breath K5 and to compare it with pony FX. Power breathe K5 is one type of device can assess automatically Maximum inspiratory pressure (MIP), Peak inspiratory pressure, Peak inspiratory flow (PIF). Design: Cross-sectional study. Methods: Thirty-five COPD patients participated in the test to investigate for the intra relater reliability and concurrent validity. The tests MIP, Vital capacity (VC), PIF were measured by Powerbreathe K5 and Pony Fx. Data was analyzed by intraclass correlation reliability (ICC) value and a standard error of measurement and Bland-Altman plots for reliability and pearson correlation for validity. Results: Intra rater reliability of the Powerbreathe K5 was very high at MIP (ICC=0.977 95%CI 0.956~0.989, SEM=8.665, MDC=0.295), PIF (ICC=0.966 95%CI 0.933~0.93, SEM=8.665, MDC=0.295), VC (ICC=0.949 95CI 0.902~0.974, SEM=0.042, MDC=0.116). The Powerbreath K5 was significant correlation compared with Pony Fx in assessment for MIP (r=0.971, p<0.05) and vital capacity (r=0.534, p<0.05). Conclusion: In this study, We investigated the clinical usefulness of the Powerbreath K5 in evaulating the MIP, VC and PIF with COPD patients with high reliability and validity.

Antioxidative and Antibacterial Activities of Artemisia princeps Pampanini Extracts (사자발쑥 추출물의 항산화 및 항균 활성)

  • Yang, Hyun Gab;Kim, Hye Jin;Kim, Hae Soo;Park, Soo Nam
    • Microbiology and Biotechnology Letters
    • /
    • v.40 no.3
    • /
    • pp.250-260
    • /
    • 2012
  • In the present study, the antioxidative and antibacterial activities of Artemisia princeps Pampanini (A. princeps Pamp.) extract were investigated. The ethyl acetate fraction of A. princeps Pamp. showed the most prominent free radical (1,1-diphenyl-2-picrylhydrazyl, DPPH) scavenging activity ($FSC_{50}=12.27{\mu}g/mL$). Reactive oxygen species (ROS) scavenging activities ($OSC_{50}$) of A. princeps Pamp. extract on $Fe^{3+}-EDTA/H_2O_2$ systems were investigated using a luminol-dependent chemiluminescence assay. The ethyl acetate fraction of the extract ($OSC_{50}=0.33{\mu}g/mL$) had a 5 times greater ROS scavenging activity than L-ascorbic acid ($1.50{\mu}g/mL$), known as a water soluble antioxidant. The cellular protective effects of fractions of A. princeps Pamp. on the rose-bengal sensitized photohemolysis of human erythrocytes were examined. The aglycone fraction of extracts suppressed photohemolysis in a concentration dependent manner. The inhibitory effects of A. princeps Pamp. extract on tyrosinase were investigated to assess their whitening efficiency. The ethyl acetate fraction demonstrated a 7 times higher tyrosinase inhibitory effect ($IC_{50}=29.20{\mu}g/mL$) than albutin, known as a whitening agent. The antibacterial activity of ethyl acetate fractions against various normal skin flora were measured. The results showed that the antibacterial activity of the fraction was the highest on Staphylococcus aureus, Bacillus subtilis, and Propionibacterium acnes. Antioxidant substances were isolated and purified from the ethyl acetate fractions. Eupatilin and jaceosidin were identified. These results indicate that the extract/fractions of A. princeps Pamp. can function as antioxidant and/or antibacterial agents for the skin.

Rate control to reduce bitrate fluctuation on HEVC

  • Yoo, Jonghun;Nam, Junghak;Ryu, Jiwoo;Sim, Donggyu
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.1 no.3
    • /
    • pp.152-160
    • /
    • 2012
  • This paper proposes a frame-level rate control algorithm for low delay video applications to reduce the fluctuations in the bitrate. The proposed algorithm minimizes the bitrate fluctuations in two ways with minimal coding loss. First, the proposed rate control applies R-Q model to all frames including the first frame of every group of pictures (GOP) except for the first one of a sequence. Conventional rate control algorithms do not use any R-Q models for the first frame of each GOP and do not estimate the generated-bit. An unexpected output rate result from the first frame affects the remainder of the pictures in the rate control. Second, a rate-distortion (R-D) cost is calculated regardless of the hierarchical coding structure for low bitrate fluctuations because the hierarchical coding structure controls the output bitrate in rate distortion optimization (RDO) process. The experimental results show that the average variance of per-frame bits with the proposed algorithm can reduce by approximately 33.8% with a delta peak signal-to-noise ratio (PSNR) degradation of 1.4dB for a "low-delay B" coding structure and by approximately 35.7% with a delta-PSNR degradation of 1.3dB for a "low-delay P" coding structure, compared to HM 8.0 rate control.

  • PDF

Analysis of Cationic Surfactants in Cosmetics By Reverse phase Ion-Pair Chromatigraphy with Suressed Conductivity Detector and UV Detector

  • Jong-Keun Choi;Jae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.23 no.3
    • /
    • pp.161-167
    • /
    • 1997
  • Determination of several cationic surfactants in cosmetics has been investigated. Reverse phase ion pair chromatography was used to identify and quantitate cationic surfactants. Cationic surfactants analyzed in this experiment were cetylpyridium chloride, stearyltrimetylammonium chloride, bezalkonium chloride, benzyldicethylcetylammonium chloride, and bihenyltrimethyl ammonium chloride. The separation was achieved on a reverse phase coumn with 10mM HCl-acetonitrile eluent. In this condition, the most of cationic surfactants with exception of CPC and CTAC respectively with suppressed conductivity detector and UV detector connected in series. The calibration curves obtained by plotting the peak areas of the cationic surfactants were linear at levels ranging from 0.005 to 0.1% correlation coefficient, r=0.9988. The detection limits were 1 to 5ppm in sample solution. The average recoveries of cationic surfactants added to hair treatment cream and hair rinse in three to five experiments were 96.7 105.2% and relative standard deviations were 1.1-3.8%. The case that there were CPC and CTAC in same solution was also tested. CPC and CTAC which couldn't be separated on reverse phase column were quantitated with suppressed conductivity detector and UV detector connected in series. Recovery of CPC and CTAC were 101.6 and 89.2% respectively. The proposed method was applied to the determination of cationic surfactants in commercial hair treatment cream.

  • PDF