• Title/Summary/Keyword: R-Peak

Search Result 1,514, Processing Time 0.032 seconds

Toxicokinetics of 4-tert-octylphenol in rats (Rat에서의 Octylphenol의 독성동태 연구)

  • 손수정;강현구;이선우;서수경;박인숙;안미령;최홍석;조재민;손동환
    • Environmental Mutagens and Carcinogens
    • /
    • v.21 no.2
    • /
    • pp.122-127
    • /
    • 2001
  • 4-tert-octylphenol (OP) is a surfactant additive widely used in the manufacture of a variety of detergents and plastic products. Also, OP is known to have estrogenic activity by interacting with development and functions of endocrine system. This study was carried out to obtain toxicokinetic parameters of OP in male Sprague-Dawley rats. Male rats were administered OP, by either single oral (gavage) applications of 50, 100 or 200 mg/kg body weight. or a single intravenous injections of 1, 5 or 10 mg/kg body weight. Blood samples taken at several time intervals after administration were obtained from the femoral artery. Analysis of blood samples for OP was performed by gas chromatography mass spectrometry (GC/MS). The detection limit of OP was 1.9 ng/$m\ell$ at SIM (selected ion monitoring) mode of GC/MS. Calibration curve for analysis of the concentrations of OP in plasma was (OP/butylphenol peak area ratio) = 0.0294 $\times$ (plasma cone.) + 0.028 ($r^2$= 0.9991). The OP plasma concentration was 3921 ng/$m\ell$ immediately after single intravenous application, decreased rapidly within 45 min, and was detectable at low concentration up to 6 hr after application. When administered orally in rats (50, 100 and 200 mg/kg), OP was detected in the blood early after gavage administration, indicating the rapid initial uptake from gastrointestinal tract, with Tmax obtained from 0.67~0.83 hr. Using the AUC (area under the curve) of plasma concentration vs. time, low oral bioavailabilities of 1.2, 5.0 and 5.3% were calculated for the 50, 100 and 200 mg/kg groups, respectively.

  • PDF

Determination of Hg22+ Ions Using a Modified Glassy Carbon Electrode with 2,2':6':2''-Terpyridine

  • Kong, Young-Tae;Bae, Yun-Jung;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.346-350
    • /
    • 2002
  • A glassy carbon electrode (GCE) modified with 2,2':6':2”-terpyridine (2,2':6':2”-TPR) using a spin coating method was applied for the highly selective and sensitive analysis of a trace amount of $Hg_2^{2+}$ ions. Various experimental parameters, which influenced the response of the 2,2':6':2”-TPR modified electrode to $Hg_2^{2+}$ ions, were optimized. The linear sweep and differential pulse voltammograms for the 2,2':6':2”-TPR modified electrode deposited with Hg show a well-defined anodic peak at +0.65 V (vs. Ag|AgCl). After a 25 min preconcentration time in an $Hg_2^{2+}$ ion solution (0.1 M acetate buffer, pH 5.0), differential pulse voltammetry(DPV) with 2,2':6':2”-TPR modified electrode shows a linear response between $1.0\;{\times}\;10^{-6}M\;and\;2.0\;{\times}\;10^{-7}M$. The least-square treatment of these data produce an equation of I[${\mu}A$] = 0.031 + 0.005C with r = 0.980(n = 5). The detection limit of this electrode with linear sweep voltammetry and differential pulse anodic voltammetry were $2.0\;{\times}\;10^{-6}M\;and\;8.0\;{\times}\;10^{-8}M$, respectively. The presence of Pb, Fe, Cd, Ti, Ni, Co, Mg, Al, Mn, and Zn did not interfere in the analysis of the $Hg_2^{2+}$ ion. The 2,2':6':2”-TPR modified GCE has been successfully applied in determination trace amounts of Hg in a human urine sample.

Fabrication and Test of the Three-Phase 6.6 kV Resistive Superconducting Fault Current Limiter Using YBCO Thin Films (YBCO 박막을 이용한 3상 6.6kV 저항형 초전도 한류기 제작 및 시험)

  • Sim J.;Kim H. R.;Park K. B.;Kang J. S.;Lee B. W.;Oh I. S.;Hyun O. B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.3
    • /
    • pp.50-55
    • /
    • 2004
  • We fabricated and tested a resistive type superconducting fault current limiter (SFCL) of three-phase 6.6 $kV_{rms}/200 A_{rms}$ rating based on YBCO thin films grown on sapphire substrates with a diameter of 4 inches, Short circuit tests were carried out at a accredited test facility for single line-to- ground faults, phase-to-phase faults and three-phase faults, Each phase of the SFCL was composed of 8${\times}$6 elements connected in series and parallel respectively. Each element was designed to have the rated voltage of 600 $V_{rms}$. A NiCr shunt resistor of 23 Ω was connected to each element for simultaneous quenches. Firstly, single phase-to-ground fault tests were carried out. The SFCL successfully developed the impedance in the circuit within 0.12 msec after fault and controlled the fault current of 10 $kA_{rms} below 816 A_{peak}$ at the first half cycle. In addition, in case of phase-to-phase fault and three- phase fault test. simultaneous quenches among the SFCLs of the phases successfully accomplished. In conclusion. the SFCL showed excellent performance of current limitation upon fault and stable operation regardless of the amplitude of fault currents.

Evaluation of Machining Characteristics through Wire-Cut EDM of Brass and SKD 11 (황동과 금형강의 와이어 컷 방전가공을 통한 가공특성 평가)

  • 김정석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.4
    • /
    • pp.130-137
    • /
    • 1997
  • The demand for wire-cut EDM is increasing rapidly in the die and tool making industry. In this study machining characteristics such as machining rate, surface roughness, hand drum form and hardness of machined material are investigated experimentally under the conditions varing pulse on time, pulse off time, peak voltage, wire tension after fixing other conditions in SKD 11 and brass and brass workpiece. It was found that various operating conditions had significant influences on machining characteristics. But the hardness of workpiece was uneffected by operating conditions. Also it was obtained experimentally that brass workpeice had better machinability than SKD 11 one.dition according to the current(Ip) in an electric spark machine : 1) Electrode is utilized Cu and Graphite. 2) Work piece is used the material of carbon steel. The condition of experiment is : 1) Current is varied 0.7(A) to 50(A) and the time of electric discharging to work piece in each time is 30(min) to 60(min). 2) After the upper side of work piece was measured in radius(5$\mu$m) of stylus analyzed the surface roughness to ade the table and graph of Rmax by yielding data. 3) Electro wear ratio is : \circled1Cooper was measured ex-machining and post-machining by the electronic balance. \circled2The ex-machining of graphite measured by it, the post-machining was found the data from volume $\times$specific gravity and analyzed to made its table and graph on ground the data. 4) In order to keep the accuracy of voltage affected to the work piece was equipped with the A.V. R and the memory scope was sticked to the electric spark machine. 5) In order to preserve the precision of current, to get rid of the noise occured by internal resistance of electric spark machine and to force injecting for the discharge fluid , it made the fixed table for a work piece to minimize the work error by means of one's failure during the electric discharging.

  • PDF

Using a Bismuth-film Glassy Carbon Electrode Based on Anodic Stripping Voltammetry to Determine Cadmium and Lead in a Standard Rice Flour (양극벗김전위법 비스무스막 유리탄소전극을 이용한 표준 쌀 분말 내 카드뮴과 납 측정)

  • Kim, Hak-Jin;Son, Dong-Wook;Mo, Chang-Yeon;Han, Jae-Woong;Kim, Gi-Young;Park, Sang-Won;Om, Ae-Son
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.377-381
    • /
    • 2009
  • Excessive presence of heavy metals in environment may contaminate plants and fruits grown in that area. Rapid on-site monitoring of heavy metals can provide useful information to efficiently characterize heavy metal-contaminated sites and minimize the exposure of the contaminated food crops to humans. This study reports on the evaluation of a bismuth-coated glassy carbon electrode for simultaneous determination of cadmium (Cd) and lead (Pb) in a NIST-SRM 1568a rice flour by anodic stripping voltammetry (ASV). The use of a supporting electrolyte 0.1 M $HNO_3$ at a dilution ratio (sample pretreated with acid digestion in a microwave oven: supporting electrolyte) of 1:1 provided well-defined, sharp and separate peaks for Cd and Pb ions, thereby resulting in strongly linear relationships between Cd and Pb concentrations and peak currents measured with the electrode ($R^2\;=\;0.97$, 0.99 for Cd and Pb, respectively). The validation test results for spiked standard solutions with different concentrations of Cd and Pb gave acceptable predictability for both spiked Cd and Pb ions with mean prediction errors of 6 to 30%. However, the applicability of the electrode to the real rice flour sample was limited by the fact that Cd concentrations spiked in the rice flour sample were overly estimated with relatively high variations even though Pb ion could be quantitatively measured with the electrode.

Evaluation of Combustion Characteristics of Outdoor Advertisement Materials (옥외 광고물 소재의 연소특성 평가)

  • Eom, Sang-Yong;Kim, Kyoung-Jin;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.79-84
    • /
    • 2012
  • Combustion characteristics of outdoor advertisement materials were evaluated for fire risk assessment about fire expanding. At this study, the flame retardancy and the limiting oxygen index (LOI) was measured by UL 94 and ASTM D 2863 respectively. At the result of flame retardancy, foamex was V-0 grade and those of others were out of grade. LOI measurement showed that the LOI of foamex was highest in the samples. The cone calorimeter test was done by ISO 5660-1 to find the combustion characteristics. The cone calorimeter test showed that the outdoor advertisement materials were not good to prevent of fire expanding. The time to ignition (TTI) of flex was the fastest and the peak heat release rate (PHRR) as well as the total heat release (THR) of acrylic panel was higher than those of others.

Association of Metabolic Syndrome with Exercise Capacity and Heart Rate Recovery after Treadmill Exercise Test

  • Shin, Kyung-A
    • Biomedical Science Letters
    • /
    • v.17 no.4
    • /
    • pp.305-311
    • /
    • 2011
  • Heart rate recovery (HRR) immediately after a treadmill exercise test is a function of vagal reactivation. A delayed heart rate recovery is associated with an increased risk for overall cardiovascular mortality. The purpose of this study is to find out if metabolic syndrome is associated with autonomic nerve function and exercise capacity in healthy adults. We measured the treadmill exercise capacity (METs) and heart rate recovery in 119 subjects through a medical checkup at $J$ General Hospital. The metabolic syndrome was defined according to the National Cholesterol Education Program Adult Treatment Panel III (NCEP-ATP III) criteria. The value for the HRR was defined as the difference between the heart rate obtained during the peak exercise and the heart rate obtained at first minute during the recovery period. The subjects with the metabolic syndrome had significantly lower exercise duration ($9.6{\pm}1.5$ vs $8.7{\pm}1.4$), METs ($11.6{\pm}1.7$ vs $10.4{\pm}2.5$), and HRR ($37.5{\pm}14.3$ vs $27.1{\pm}8.9$). The waist circumference in subjects with the metabolic syndrome was more strongly correlated with HRR ($r$=-.517, $P$ <.001) than in normal subjects. Furthermore, delayed HRR was associated with high resting heart rate and increased waist circumference ($P$=.032, $P$ <.001, respectively). In conclusion, delayed HRR during the first minute after a treadmill exercise test was associated with the metabolic syndrome risk factors. Delayed HRR was also associated with high resting heart rate and increased waist circumference.

Microbial Enrichment and Community Analysis for Bioelectrochemical Acetate Production from Carbon Dioxide (이산화탄소로부터 생물전기화학적 아세트산 생산을 위한 미생물 농화배양 및 군집 분석)

  • Kim, Junhyung;Kim, Young-Eun;Park, Myeonghwa;Song, Young Eun;Seol, Eunhee;Kim, Jung Rae;Oh, You-Kwan
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.58-67
    • /
    • 2020
  • Microbial electrosynthesis has recently been considered a potentially sustainable biotechnology for converting carbon dioxide (CO2) into valuable biochemicals. In this study, bioelectrochemical acetate production from CO2 was studied in an H-type two-chambered reactor system with an anaerobic microbial consortium. Metal-rich mud flat was used as the inoculum and incubated electrochemically for 90 days under a cathode potential of -1.1 V (vs. Ag/AgCl). Four consecutive batch cultivations resulted in a high acetate concentration and productivity of 93 mmol/L and 7.35 mmol/L/day, respectively. The maximal coulombic efficiency (rate of recovered acetate from supplied electrons) was estimated to be 64%. Cyclic voltammetry showed a characteristic reduction peak at -0.2~-0.4 V, implying reductive acetate generation on the cathode electrode. Furthermore, several electroactive acetate-producing microorganisms were identified based on denaturing- gradient-gel-electrophoresis (DGGE) and 16S rRNA sequence analyses. These results suggest that the mud flat can be used effectively as a microbial source for bioelectrochemical CO2 conversion.

Pharmacokinetic Drug Interaction between Carvedilol and Ticlopidine in Rats

  • Choi, Jun-Shik;Choi, Dong-Hyun
    • Biomolecules & Therapeutics
    • /
    • v.18 no.3
    • /
    • pp.343-349
    • /
    • 2010
  • This study was designed to investigate the effects of ticlopidine on the pharmacokinetics of carvedilol after oral or intravenous administration of carvedilol in rats. Carvedilol was administered orally (3 mg/kg) or intravenously (1 mg/kg) without or with oral administration of ticlopidine (4, 12 mg/kg) to rats. The effects of ticlopidine on P-glycoprotein (P-gp) and cytochrome P450 (CYP) 2C9 activity were also evaluated. Ticlopidine inhibited CYP2C9 activity in a concentration-dependent manner with 50% inhibition concentration ($IC_{50}$) of $25.2\;{\mu}M$. In addition, ticlopidine could not significantly enhance the cellular accumulation of rhodamine 123 in MCF-7/ADR cells overexpressing P-gp. Compared with the control group (given carvedilol alone), the area under the plasma concentration-time curve (AUC) was significantly (12 mg/kg, p<0.05) increased by 14-41%, and the peak concentration ($C_{max}$) was significantly (12 mg/kg, p<0.05) increased by 10.7-73.3% in the presence of ticlopidine after oral administration of carvedilol. Consequently, the relative bioavailability (R.B.) of carvedilol was increased by 1.14- to 1.41-fold and the absolute bioavailability (A.B.) of carvedilol in the presence of ticlopidine was increased by 36.2-38.5%. Compared to the i.v. control, ticlopidine could not significantly change the pharmacokinetic parameters of i.v. administered carvedilol. The enhanced oral bioavailability of carvedilol may result from inhibition of CYP2C9-mediated metabolism rather than P-gpmediated efflux of carvedilol in the intestinal and/or in liver and renal eliminatin of carvedilol by ticlopidine.

PEGylated Erythropoietin Protects against Brain Injury in the MCAO-Induced Stroke Model by Blocking NF-κB Activation

  • Im, Jun Hyung;Yeo, In Jun;Hwang, Chul Ju;Lee, Kyung Sun;Hong, Jin Tae
    • Biomolecules & Therapeutics
    • /
    • v.28 no.2
    • /
    • pp.152-162
    • /
    • 2020
  • Cerebral ischemia exhibits a multiplicity of pathophysiological mechanisms. During ischemic stroke, the reactive oxygen species (ROS) concentration rises to a peak during reperfusion, possibly underlying neuronal death. Recombinant human erythropoietin (EPO) supplementation is one method of treating neurodegenerative disease by reducing the generation of ROS. We investigated the therapeutic effect of PEGylated EPO (P-EPO) on ischemic stroke. Mice were administered P-EPO (5,000 U/kg) via intravenous injection, and middle cerebral artery occlusion (MCAO) followed by reperfusion was performed to induce in vivo ischemic stroke. P-EPO ameliorated MCAO-induced neurological deficit and reduced behavioral disorder and the infarct area. Moreover, lipid peroxidation, expression of inflammatory proteins (cyclooxygenase-2 and inducible nitric oxide synthase), and cytokine levels in blood were reduced by the P-EPO treatment. In addition, higher activation of nuclear factor kappa B (NF-κB) was found in the brain after MCAO, but NF-κB activation was reduced in the P-EPO-injected group. Treatment with the NF-κB inhibitor PS-1145 (5 mg/kg) abolished the P-EPO-induced reduction of infarct volume, neuronal death, neuroinflammation, and oxidative stress. Moreover, P-EPO was more effective than EPO (5,000 U/kg) and similar to a tissue plasminogen activator (10 mg/kg). An in vitro study revealed that P-EPO (25, 50, and 100 U/mL) treatment protected against rotenone (100 nM)-induced neuronal loss, neuroinflammation, oxidative stress, and NF-κB activity. These results indicate that the administration of P-EPO exerted neuroprotective effects on cerebral ischemia damage through anti-oxidant and anti-inflammatory properties by inhibiting NF-κB activation.