• Title/Summary/Keyword: R-Peak

Search Result 1,514, Processing Time 0.03 seconds

Interictal Epileptiform Discharges and Background Delta Frequency Bands in Scalp EEGs of Epileptic Patients: Anatomical Correlation between the Current Source Distributions (간질환자 두피뇌파의 발작사이간질모양방전과 배경파 델타영역: 전류원분포의 해부학적 연관성)

  • Jung, Seung-Uk;Kwon, Oh-Young;Kang, Jong-Soo;Ha, Eun-Ok;Jung, Seo-Kwon;Kang, Kyu-Sik;Kang, Hee-Young;Park, Ki-Jong;Choi, Nack-Cheon;Lim, Byeong-Hoon
    • Annals of Clinical Neurophysiology
    • /
    • v.11 no.1
    • /
    • pp.16-23
    • /
    • 2009
  • Background: The intermittent delta activity in electroencephalographies (EEGs) of patients with focal brain lesions has been reported to be a marker of an epileptogenic focus. This study investigated the concordance between the current source distribution (CSD) of the interictal epileptiform discharges (IEDs) and that of the background delta frequency bands (DFBs) of the scalp EEG. Methods: We collected scalp EEGs of 13 patients with focal epilepsy that contained uniregional IEDs and unilateral delta to theta slow waves. We applied a distributed source model using LORETA$^{(R)}$ to determine the CSD of the peak points of the IEDs and the DFBs of the background activity. Results: The CSDs of the DFBs were ipsilateral to the CSDs of the peak point of the averaged IEDs in ten patients, and bilateral with ipsilateral predominance in three patients. In the cases with an ipsilateral CSD of the DFB, 8 of 10 patients had concordance of the CSD localization between the averaged IED and the DFB. In the cases with bilateral CSD of the DFB, 2 of 3 patients had concordance of the CSD localization between the averaged IED and the DFB. Conclusions: The CSD localization and lateralization appear to be concordant between the IEDs and the DFB of background activity in epileptic patients. Therefore, the CSD of the DFB in EEGs with visually observable slow activities may predict those of IEDs.

  • PDF

Comparison of Grain Quality Traits between Japonica Rice Cultivars from Korea and Yunnan Province of China

  • Yu, Teng-Qiong;Jiang, Wenzhu;Ham, Tae-Ho;Chu, Sang-Ho;Lestari, Puji;Lee, Jeong-Heui;Kim, Myeong-Ki;Xu, Fu-Rong;Han, Longzhi;Dai, Lu-Yuan;Koh, Hee-Jong
    • Journal of Crop Science and Biotechnology
    • /
    • v.11 no.2
    • /
    • pp.135-140
    • /
    • 2008
  • Improving eating quality is one of the most important objectives in japonica rice breeding programs in Yunnan Province of China. Eating quality and its relevant traits of nine Korean and 11 Yunnan rice cultivars were comparatively analyzed in this study. The grain shape of most Yunnan japonica rice cultivars have a relatively slender shape and are slightly larger than Korean rice cultivars. Palatability value of cooked rice of Yunnan rice cultivars was significantly lower, while the protein content of Yunnan rice cultivars was significantly higher than that of Korean cultivars. Peak viscosity and breakdown viscosity of the Yunnan rice cultivars were significantly lower, while setback viscosity of the Yunnan rice cultivars was significantly higher than in Korean rice cultivars. Palatability value of cooked rice was negatively correlated with protein content and setback viscosity but positively correlated with peak viscosity, breakdown viscosity, and cool paste viscosity. Through multiple linear regression analysis, an equation for estimating palatability value(PV) of cooked rice based on quality traits was generated as dependent only upon protein content(PC), PV=139.024-(10.865$\times$PC) with an $R^2$ value of 0.822. The results suggest that reducing protein contents should be the major target in improving eating quality of Yunnan japonica rice cultivars through integrated approaches of both cultivar development and appropriate cultural practices. Genetic similarities among cultivars based on DNA markers which had been identified as associated with grain quality seemed not to be directly related to PV.

  • PDF

Changes of IgE production, splenic helper and suppressor T lymphocytes in mice infected with Paragonimus westermani (폐흡충(Paragonimus westermani) 감염이 흰쥐의 IgE 생성 및 비장림프구 아군분포에 미치는 영향)

  • Min, Deuk-Yeong;Ryu, Jae-Suk;Sin, Myeong-Heon
    • Parasites, Hosts and Diseases
    • /
    • v.31 no.3
    • /
    • pp.231-238
    • /
    • 1993
  • Effects of Paragonims westermai infection were observed in mice on the change of serum IgE level, the number of peripheral eosinophils and the distribution of Thy $1.2^{+}{\;}(CD3),{\;}L3T4^{+}{\;}(CD4),{\;}and{\;}Lyt-2^{+}$ (CD8) splenic T Iymphocytes without mitogen serum IgE increased at 3 weeks after the infection and reached a peak on week 4 and maintained high levels of IgE until the 23r6 week. Peripheral eosinophil numbers Increased at the second week and attained peak level on week 9. The frequency of $L3T4^{+}$(CD4) and $Lyt-2^{+}$ (CD8) T Iymphocytes decreased slightly until 4 weeks after the infection, but not significantly. Absolute number of $L3T4^{+}{\;}and{\;}Lyt-2^{+}$ T Iymphocytes, and the ratio of L3T4/Lyt-2 were not markedly changed over the period of observation. The frequency of Thy $1.2^{+}$ (CD3) T lymphocytes in the infected group slightly decreased until 4 weeks after the infection and showed significant reductions at the 2nd and 4th week of the infection (p < 0.05).

  • PDF

Ductile Behavior of Ultra High Performance Fiber Reinforced Concrete Segmental Box Girder (초고강도 섬유보강 콘크리트 분절형 박스거더의 연성 거동)

  • Jeong, Min-Seon;Park, Sung-Yong;Han, Sang-Mook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.282-289
    • /
    • 2017
  • The flexural behavior tests of UHPC segmental Box girder which has 160MPa compressive strength and 15.4m length were carried out. The test variables are area of prestressing wires, volume fraction of steel fibers and longitudinal reinforcing bars in upper flange and web. PS tendons which has 32 strands of 15.2mm diameter in lower flange, 24 strands and 14 strands in lower flange were arranged and volume fraction of 2%, 1.5% and 1.0% is used in box girder concrete. UHPFRC box girder which has 32 strands in lower flange showed the over reinforcement and brittle behavior. UHPFRC box girder which has 24 strands showed the similar peak load as 32 strands girder and ductile behavior as large deflection. UHPFRC box girder which has 14 strands showed half of the peak load of 24 strands box girder and ductile behavior. After the application of the formular for the reinforcement index to the behavior of the UHPFRC box girders, reinforcement index does not determine the characteristic of behavior of UHPFRC box girder exactly. So the index should consider the dimension precisely and modify the reference value corresponding to the 0.005 strain of the prestressing strands.

A 3-D Measuring System of Thermoluminescence Spectra and Thermoluminescence of CaSO4 : Dy, P (열자극발광 스펙트럼의 3차원 측정 장치와 CaSO4 : Dy, P의 열자극발광)

  • Lee, Jung-Il;Moon, Jung-Hak;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.71-75
    • /
    • 2001
  • In this paper, a three-dimensional measuring system of thermoluminescence(TL) spectra based on temperature, wavelength and luminescence intensity was introduced. The system was composed of a spectrometer, temperature control unit for thermal stimulation, photon detector and personal computer for control the entire system. Temperature control was achieved by using feedback to ensure a linear-rise in the sample temperature. Digital multimeter(KEITHLEY 195A) measures the electromotive force of Copper-Constantan thermocouple and then transmits the data to the computer through GPIB card. The computer converts this signal to temperature using electromotive force-temperature table in program, and then control the power supply through the D/A converter. The spectrometer(SPEX 1681) is controlled by CD-2A, which is controlled by the computer through RS-232 communication port. For measuring the luminescence intensity during the heating run, the electrometer(KEITHLEY 617) measures the anode current of photomultiplier tube(HAMAMATSU R928) and transmits the data to computer through the A/D converter. And, we measured and analyzed thermoluminescence of $CaSO_4$ : Dy, P using the system. The measuring range of thermoluminescence spectra was 300K-575K and 300~800 nm, $CaSO_4$ : Dy. P was fabricated by the Yamashita's method in Korea Atomic Energy Research Institute(KAERI) for radiation dosimeter. Thermoluminesce spectra of the $CaSO_4$ : Dy, P consist of two main peak at temperature of $205^{\circ}C$, wavelength 476 nm and 572 nm and with minor ones at 658 nm and 749 nm.

  • PDF

Effect of Annealing in a Nitrogen Atmosphere on the Properties of In2O3 Films Deposited with RF Magnetron Sputtering (RF 마그네트론 스퍼터로 증착된 In2O3 박막의 질소분위기 열처리에 따른 특성변화)

  • Kong, Young-Min;Lee, Young-Jin;Heo, Sung-Bo;Lee, Hak-Min;Seo, Min-Su;Kim, Yu-Sung;Kim, Dae-Il
    • Korean Journal of Materials Research
    • /
    • v.22 no.1
    • /
    • pp.24-28
    • /
    • 2012
  • $In_2O_3$ films were deposited by RF magnetron sputtering on a glass substrate and then the effect of post deposition annealing in nitrogen atmosphere on the structural, optical and electrical properties of the films was investigated. After deposition, the annealing process was conducted for 30 minutes at 200 and $400^{\circ}C$. XRD pattern analysis showed that the as deposited films were amorphous. When the annealing temperature reached 200-$400^{\circ}C$, the intensities of the $In_2O_3$ (222) major peak increased and the full width at half maximum (FWHM) of the $In_2O_3$ (222) peak decreased due to the crystallization. The films annealed at $400^{\circ}C$ showed a grain size of 28 nm, which was larger than that of the as deposited amorphous films. The optical transmittance in the visible wavelength region also increased, while the electrical sheet resistance decreased. In this study, the films annealed at $400^{\circ}C$ showed the highest optical transmittance of 76% and also showed the lowest sheet resistance of $89{\Omega}/\Box$. The figure of merit reached a maximum of $7.2{\times}10^{-4}{\Omega}^{-1}$ for the films annealed at $400^{\circ}C$. The effect of the annealing on the work-function of $In_2O_3$ films was considered. The work-function obtained from annealed films at $400^{\circ}C$ was 7.0eV. Thus, the annealed $In_2O_3$ films are an alternative to ITO films for use as transparent anodes in OLEDs.

Isokinetic Test of the Extensors and Flexors in Total Knee Replacement Patients (슬관절 전치환술 환자의 슬관절 신전근 및 굴곡근에 대한 등속성운동검사)

  • Lee, Keun-Heui;Lee, Hyun-Ok;Lee, In-Sil;Seo, Hyun-Kyu;Kim, Seung-Joon;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.585-596
    • /
    • 2001
  • The twenty one individuals with total knee replacement who were admitted to Kang-Dong Hospital for comprehensive physical therapy were studied in order to demonstrate the effectiveness of an isokinetic test program using the Cybex 6000 machine. The subjects were divided into three groups with the isometric exercise group receiving isometric exercise, the isokinetic eccentric exercise group, and isokinetic concentric exercise group receivind isokinetic exercise(eccentric, concentric) to knee flexors and extensors muscles for a six weeks' period using the Cybex 6000. The results are follow: 1. The extensors were increased significantly at all groups after 6 weeks training(p<.05). The flexors were increased significantly at isokinetic eccentric and isokinetic concentric group but no significantly differences at isometric group(p>.05) 2. At the effect of extensors and flexors after 6 weeks training. higher to 30$^{\circ}$ /sec of isokinetic concentric exercise, lower to 120$^{\circ}$ /sec of isometric exercise. 3. The peak torque was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups. 4. The total work was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups. 5. The ratio of peak torque to body weight were more increased significantly in the flexors and extensors of the isikinetic conccentric exercise among three groups. 6. The average power was more increased significantly in the flexors and extensors of the isikinetic conccentric exercise among three groups. 7. The average R.O.M in the pre-exercise and post-exercise was not different significantly in all three groups. According to the above results, In the muscle strength recovery for total knee replacement patients, isokinetic concentric exercise group was significantly greater than the isokinetic eccentric and isometric exercise groups after a six weeks training.

  • PDF

Analysis of the Mean and Standard Deviation due to the Change of the Probability Density Function on Tidal Elevation Data (조위의 확률밀도함수 변화에 따른 평균 및 표준편차 분석)

  • Cho, Hong-Yeon;Jeong, Shin-Taek;Lee, Khil-Ha;Kim, Tae-Heon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.4
    • /
    • pp.279-285
    • /
    • 2010
  • In the process of the probabilistic-based design on the coastal structures, the probability density function (pdf) of tidal elevation data is assumed as the normal distribution function. The pdf shape of tidal elevation data, however, is better-fitted to the double-peak normal distribution function and the equivalent mean and standard deviation (SD) estimation process based on the equivalent normal distribution is required. The equivalent mean and SD (equivalent parameters) are different with the mean and SD (normal parameters) estimated in the condition that the pdf of tidal elevation is normal distribution. In this study, the difference, i.e., estimation error, between equivalent parameters and normal parameters is compared and analysed. The difference is increased as the tidal elevation and its range are increased. The mean and SD differences in the condition of the tidal elevation is ${\pm}400cm$ are above 100 cm and about 80~100 cm, respectively, in Incheon station. Whereas, the mean and SD differences in the condition of the tidal elevation is ${\pm}60cm$ are very small values in the range of 2~4 cm, in Pohang station.

Behavior of Non-seismic Detailed Low-Rise R/C Exterior Beam-to-Column Joints Subjected to Cyclic Loading (반복 하중을 받는 비내진 저층 RC 구조물의 외부 기둥-보 접합부의 거동)

  • Sur, Man-Sik;Chang, Chun-Ho;Kim, Young-Moon
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.109-118
    • /
    • 1999
  • Seismic design code has been performed since 1988 in Korea, so it has not been applied to low-rise reinforced concrete buildings which had been built before 1988. Those building have been designed only for gravity loads based on non-seismic code, Therefore, even minor earthquake occurred, those buildings might have serious damages. In this paper, to investigate the behavior of low-rise reinforced concrete moment resisting frame which had been built in according to the building code of Korea that had been published before 1988, two type of 1/2 scaled exterior beam-column subassemblies which have non-seismic detailing based on the building code of Korea were constructed and tested with reversed cycling loading under the displacement control method. The special features of joint with non-seismic detailing is that there is no transverse reinforcement in the joint. In tests, cracks pattern, strength degradation, loss of stiffness, energy dissipation and the slippage of beam and column bars were investigated. Cracks did not occurred in the joint even seismic loading of 0.12g which is considered as peak ground acceleration in Korea was applied. And increasing seismic loading above 0.12g shear crack happened in the joint which have not transverse beam.

Characterizations of graded AlGaN epilayer grown by HVPE (HVPE 방법에 의해 성장된 graded AlGaN 에피층의 특성)

  • Lee, Chanbin;Jeon, Hunsoo;Lee, Chanmi;Jeon, Injun;Yang, Min;Yi, Sam Nyung;Ahn, Hyung Soo;Kim, Suck-Whan;Yu, Young Moon;Sawaki, Nobuhiko
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.2
    • /
    • pp.45-50
    • /
    • 2015
  • Compositionally graded AlGaN epilayer was grown by HVPE (hydride vapor phase epitaxy) on (0001) c-plane sapphire substrate. During the growth of graded AlGaN epilayer, the temperatures of source and the growth zone were set at $950^{\circ}C$ and $1145^{\circ}C$, respectively. The growth rate of graded AlGaN epilayer was about 100 nm/hour. The changing of Al contentes was investigated by field emission scanning electron microscope (FE-SEM) and energy dispersive spectroscopy (EDS). From the result of atomic force microscope (AFM), the average of roughness in 2 inch substrate of graded AlGaN epilayer was a few nanometers scale. X-ray diffraction (XRD) with the result that the AlGaN (002) peak ($Al_{0.74}Ga_{0.26}N$) and AlN (002) peak were appeared. It seems that the graded AlGaN epilayer was successfully grown by the HVPE method. From these results, we expect to use of the graded AlGaN epilayer grown by HVPE for the application of electron and optical devices.