• Title/Summary/Keyword: R-Mode

Search Result 1,586, Processing Time 0.029 seconds

Dielecrtric and Voltage Holding Properties of the Half-V-shaped Switching Ferroelectric Liquid Crystal Mode Driven by Active Matrix

  • Choi, Suk-Won;Kim, Hong-Chul;Jeong, Woo-Nam;Seo, Chang-Ryong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1121-1124
    • /
    • 2003
  • For high quality displays, analog responding liquid crystals with spontaneous polarization ($P_{s}$) need to be coupled with active matrix driving schemes. We have characterized the half-V-shaped switching ferroelectric liquid crystal mode (half-V FLC mode) in terms of dielectiric and voltage holding properties. Research on these switching properties provided us with the technology for switching half-V FLC mode FLCs by using amorphous silicon TFTs.

  • PDF

A Design of IFF Mode 5 Interworking Gateway Prototype (IFF Mode 5 연동 게이트웨이 프로토타입 설계)

  • Nam, Sung-woo;Kim, Jun-young;Oh, Sun-taek
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.05a
    • /
    • pp.208-211
    • /
    • 2018
  • 현재 해군에서는 기존 전투함에서 사용 중인 IFF Mode 4 를 대체하여 IFF Mode 5 를 도입할 계획을 갖고 있다. IFF Mode 5 기능을 사용하기 위해서는 IFFMode 5 설치뿐만 아니라 IFFMode 5 와 연동을 수행하는 기존 전투함의 전투체계 변경도 필요하다. 하지만 기존 전투함의 전투체계를 변경할 경우 개발 비용과 개발 기간이 크게 증가하게 된다. 본 논문에서는 이를 완화시키기 위한 방안에 대해서 프로토타입을 통해 검증했던 프로젝트를 소개하고, 기존의 전투체계를 변경하지 않는 방식으로 IFFMode 5 와 연동을 수행할 수 있는 게이트웨이 설계 방안을 제시한다.

A Novel Fast-Switching LCD with Dual-Domain Bend Mode

  • Satake, Tetsuya;Kurata, Tetsuyuki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.209-212
    • /
    • 2004
  • A navel fast-switching LCD with dual-domain bend (DDB) mode is described DDB alignment is achieved using antiparallel-rubbed cell filled with chiral-doped LC. Initial alignment is mono-domain 180-degree twist. Tilt direction is controlled by oblique electric field to be counter direction in each domain Twist-to-DDB deformation occurs continuously so that DDB mode does not require high-voltage initialization which is inevitable in Optically Compensated Bend (OCB) mode. DDB gives wide and symmetric viewing angle in contrast to mono-domain bend formed from 180-degree twist showing strong asymmetry.

  • PDF

Common-Mode Current Reduction with Synchronized PWM Strategy in Two-Inverter Air-Conditioning Systems

  • Baek, Youngjin;Park, Gwigeun;Park, Dongmin;Cha, Honnyong;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1582-1590
    • /
    • 2019
  • A new method for reducing the common-mode current generated by the voltage variations in a two-inverter air conditioner system by applying a synchronized pulse-width modulation (PWM) strategy is proposed. The PWM signals of the master-mode inverter are generated based on the reference voltage, while those of the slave-mode inverter are output in the opposite direction when the master-mode inverter changes its switching state. However, the slave-mode control results in a mismatch between the reference voltage and the actual output voltage that is modified by synchronized control operation. The proposed method is capable of reducing and controlling this voltage error by performing signal selection in the vector space of the slave-mode inverter, which mitigates the distortion of the phase current. The efficacy of this method in reducing conducted emissions has been validated both theoretically and experimentally.

A New Transflective TFT-LCD with Novel Color Filter

  • Lim, Joo-Soo;Jung, Tae-Yong;Nam, Chul;Kang, Sung-Ku;Kim, Kyeong-Jin;Ahn, Byung-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.181-183
    • /
    • 2002
  • A new 10.4" transflective TFT-LCD has been developed using newly designed color filter for sunlight readable application. High transmittance and color gamut are realized by the dual color filter and dual cell gap structure in the ECB mode. The color gamut of new device provides 17% in transmissive and 18% in reflective mode. This new device provides the $125cd/m^2$ of luminance, 240:1 and 27:1 of contrast ratio in the transmissive and reflective mode, respectively.

  • PDF

IPS-Mode Dynamic LCD-TV Realization with Low Black Luminance and High Contrast by Adaptive Dynamic Image Control Technology

  • Oh, E.Y.;Baik, S.H.;Sohn, M.H.;Kim, K.D.;Hong, H.J.;Bang, J.Y.;Kwon, K.J.;Kim, M.H.;Jang, H.;Yoon, J.K.;Chung, I.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.799-802
    • /
    • 2004
  • In this paper, the active backlight control technology with data processing algorithm was developed in order to improve image quality for IPS-mode LCD-TV applications. The image blinking problem caused by repeatedly abrupt change of the backlight luminance was solved by algorithms-Fba(Flexible Boundary algorithm) and Cfa(Cumulative Feedback algorithm)-and the optimized number and space of backlight dimming steps based on perception. In the IPS-mode 42" TFT-LCD panel, the dynamic contrast ratio can be more than twice the typical level by means of lower block luminance and higher white luminance. Additionally, Power consumption and LCD temperature was decreased.

  • PDF

Experimental Study on the Mutual Influence of Thermal Management System for Hydrogen Fuel Cell Vehicle (수소연료전지 자동차 열관리 시스템의 상호 영향도 분석을 위한 실험적 연구)

  • Lee, Moo-Yeon;Won, Jong-Phil;Cho, Choong-Won;Lee, Ho-Seong
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.6
    • /
    • pp.852-858
    • /
    • 2011
  • This paper is aiming to estimate the mutual influence of the stack cooling performances with the operation modes of the thermal management system for the hydrogen fuel cell vehicles. The heat capacity of the thermal management system was measured by varying the operating modes such as stack cooling heat exchanger only (Mode 1), stack cooling and electric devices cooling heat exchangers (Mode 2), and stack cooling and electric devices cooling heat exchangers with an operation of the condenser (Mode 3).As the results, Performance of the thermal management system (TMS) at Mode 3 decreased up to 34.0%, compared with the result of the Mode 1. In addition, in order to optimize the performance of TMS, the entropy change of stack cooling heat exchanger using irreversibility analysis technique was analyzed with the relationship between entropy generation and entering air velocity of the thermal management system.

Development of An Accelerated Durability Test Mode for Fuel Cell (연료전지 가속내구모드 개발)

  • LEE, YONGHEE;OH, DONGJO;JEON, UISIK;LEE, JONGHYUN
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.5
    • /
    • pp.493-498
    • /
    • 2015
  • The fuel cell vehicle is a type of hydrogen vehicle which uses a fuel cell to produce electricity, powering its on-board electric motor. The fuel cell vehicle driving principle is completely different from the internal combustion engine vehicle. In order to ensure the durable quality of the fuel cell vehicle, durability test mode considering the characteristics of the fuel cell must be developed. In this study, we derived the durability test mode profile through collecting and analyzing fuel cell vehicle driving data. Then, the accelerated durability test mode is developed by adding degradation conditions and is experimentally validated to have an acceleration factor of 5~6.

The Study of Measuring Method for Signal Processing Delay to Dual Mode Signal Transmission for Satellite DMB System (위성 DMB Dual Mode 신호전송에 따른 신호변환 Delay 측정 방법에 관한 연구)

  • Lee Young-Su;Choi Gyeong-Ho;Lee Byung-Suk;Cho Sung-Min;Ihm Tae-Jong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.31-34
    • /
    • 2004
  • 본 논문에서는 현재 위성 DMB 국내 표준으로 채택되어 있는 System E 방식의 Dual Mode 신호 전송에 따른 신호변환시 Time Delay측정 방법에 대해서 제안을 하였다. 제안된 방식의 경우 아날로그 방식이 아닌 디지털 방식으로 정확한 Time Delay 측정이 가능하다. 그리고 위성 DMB Gap Filler System의 입 출력 단자를 통하여 측정이 가능함으로 측정값에 대한 신뢰성 확보가 가능하며 자동측정 방식임으로 측정시 발생될 수 있는 Human Error를 최소화 할 수 있다는 장점을 가지고 있다.

  • PDF

Voltage Amplitude Control of Square-Wave VSIs with an R-L Load (R-L부하를 가진 구형파 VSI의 전압크기 제어)

  • Kim Kyung-Won;Hong Soon-Chan;Yoo Jong-Gul;Kim Sang-Kyun;Park Chae-Woon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.479-482
    • /
    • 2001
  • This paper proposes a modified $\alpha$ conduction mode for controlling the output voltage magnitude of three-phase square-wave VSIs with an R-L load. From the viewpoint of both power capacity and switching losses, three-phase square-wave inverters are now used in most high power systems. When the square-wave VSI is driven with $\alpha$ conduction mode to control the magnitude of output voltages, interval over than half period is operated with $180^{\circ}$ conduction mode and the other interval with $120^{\circ}$ conduction mode. In $120^{\circ}$ conduction mode operation, two output terminals are connected to DC supply and the third one remains open. The potential of this open terminal will depend on the load characteristics and is unpredictable except the case of pure resistive loads. To cope this problem, we propose the modified α conduction mode.

  • PDF