• Title/Summary/Keyword: R/C shell

Search Result 136, Processing Time 0.022 seconds

Behavior of R/C cylindrical shell under lateral load

  • Hara, Takashi;Shigematsu, Tsunemi;Tamura, Takahiro
    • Structural Engineering and Mechanics
    • /
    • v.16 no.3
    • /
    • pp.361-369
    • /
    • 2003
  • In this paper, the structural behavior of R/C cylindrical panel is analyzed by experimental results. To avoid the geometric imperfection, R/C shell specimens are made by use of a stiff steel mold. From experimental results, the load carrying behavior of R/C cylindrical panel is presented under an external lateral pressure. Even if R/C shell does not posses geometric imperfections, the inaccuracy of the reinforcement position strongly affects to the ultimate strength and the failure patterns of such shells. To explain these effects, FEM nonlinear analyses are done under the same conditions as those of experiments. The behavior of R/C cylindrical shells are well simulated under the consideration of both the geometric imperfection and several inaccuracies.

Application of computational technologies to R/C structural analysis

  • Hara, Takashi
    • Computers and Concrete
    • /
    • v.8 no.1
    • /
    • pp.97-110
    • /
    • 2011
  • In this paper, FEM procedure is applied to the static and dynamic analyses of R/C structures. Simple R/C shell structure is solved by using FEM procedures and the experimental evaluations are performed to represent the applicability of FEM procedure to R/C structures. Also, R/C columns are analyzed numerically and experimentally. On the basis of these results, FEM procedures are applied to the R/C cooling tower structures assembled by huge R/C shell structure and a lot of discrete R/C columns. In this analysis, the parallel computing procedures are introduced into these analyses to reduce the computational effort. The dynamic performances of R/C cooling tower are also solved by the application of parallel computations as well. From the numerical analyses, the conventional FEM procedures combined with computational technologies enables us to design the huge R/C structures statically and dynamically.

Synthesis of Au@TiO2 Core-shell Nanoparticle-decorated rGO Nanocomposite and its NO2 Sensing Properties

  • Kumar Naik, Gautam;Yu, Yeon Tae
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.225-230
    • /
    • 2019
  • $Au@TiO_2$ core-shell decorated rGO nanocomposite (NC) was prepared using a simple solvothermal method followed by heat treatment for gas sensor application. The crystal structure and morphology of the composites were characterized by X-ray powder diffraction and transmission electron microscopy, respectively. The $NO_2$ sensing response of the $Au@TiO_2/rGO$ NC was tested at operating temperatures from $250^{\circ}C$ to $500^{\circ}C$, and was compared with those of the bare rGO and $Au@TiO_2$ core-shell NPs. The $Au@TiO_2/rGO$ NC-based sensor showed a far higher response than the rGO or $Au@TiO_2$ core-shell based sensors, with the maximum response detected when the operating temperature was $400^{\circ}C$. This improved response was due to the high rGO gas absorption capability for $NO_2$ gas and the catalytic effect of $Au@TiO_2$ core-shell NPs in oxidizing $NO_2$ to $NO_3$.

Study on R-l34a, R-407C, and R-410A Condensation Performance in the Oblong Shell and Plate Heat Exchanger (오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 응축성능에 관한 실험적 연구)

  • Park, Jae-Hong;Kim, Young-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1535-1548
    • /
    • 2004
  • Condensation heat transfer experiments were conducted with the oblong shell and plate heat exchanger without oil in a refrigerant loop using R-l34a, R-407C and R-410A. An experimental refrigerant loop has been developed to measure the condensation heat transfer coefficient h$_{r}$ and frictional pressure drop $\Delta$p$_{f}$ of the various refrigerants in a vertical oblong shell and plate heat exchanger. The effects of the refrigerant mass flux(40∼80kg/$m^2$s), average heat flux(4∼8kW/$m^2$), refrigerant saturation temperature(30∼4$0^{\circ}C$) and vapor quality of refrigerants on the measured data were explored in detail. Similar to the case of a plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. A comparison of the performance of the various refrigerants revealed that R-410A had the highest heat transfer performance followed by R-l34a, and R-407C had the lowest performance of the refrigerants tested. The pressure drops were also reported in this paper. The pressure drops for R-410A were approximately 45% lower than those of R-l34a. R-407C had 30% lower pressure drops than R-l34a. Experimental results were compared with several correlations which predicted condensation heat transfer coefficients and frictional pressure drops. Comparison with the experimental data showed that the previously proposed correlations gave unsatisfactory results. Based on the present data, empirical correlations of the condensation heat transfer coefficient and the friction factor were proposed.tor were proposed.sed.

Nonlinear behavior of R/C cooling tower shells

  • Hara, Takashi;Kato, Shiro;Ohya, Makoto
    • Structural Engineering and Mechanics
    • /
    • v.5 no.5
    • /
    • pp.541-552
    • /
    • 1997
  • In this paper the ultimate strength of the R/C cooling towers, which have initial imperfection and pre-cracked elements, is analyzed. The initial geometric imperfections arise from the unavoidable inaccuracies under the construction and the pre-cracks are assumed to be produced by the temperature stress gradients or cyclic loading under wind pressure and/or earthquake load. Both effects are strongly influenced on the strength of the R/C cooling tower shell structures. The reinforcing ratio is also the important factor to evaluate the ultimate strength of the R/C cooling tower shells. However we could not analyze these structures experimentally because of their large, analyses are the powerful schemes to evaluate the safety and reliability of these structures. The analyzed model is Port Gibson cooling tower shell. In the numerical analysis the geometric and material nonlinearities are taken into account.

Preset State of Thermoreversible Poly(vinylidene fluoride)/propylene Carbonate Gel System: 1. Core-Shell Model (열가역적인 Poly(vinylidene fluoride)/Propylene Carbonate(PC) 겔 시스템에서의 Pregea 상태 : 1. Core-Shell 모델)

  • 박일현
    • Polymer(Korea)
    • /
    • v.26 no.2
    • /
    • pp.227-236
    • /
    • 2002
  • The structure of pregel state in thermoreversible poly(vinylidene fluoride)(PVDF) /propylene carbonate(PC) system was investigated by laser light scattering. It was found that the PVDF chain did not exist as a separate chain even in a very dilute concentration(i.e. 100 times more dilute than the gel formation concentration) but as a large spherical aggregate with the radius of gyration $R_G$, of 232 nm and the effective hydrodynamic radius $R_H$= of 407 nm at $40^{\circ}C$. Based upon experimental results such as $R_H/R_G$=ratio of 1.75 and the pattern of scattering intensity with a minimum, a core-shell type sphere model was suggested as a structure of the aggregate. According to this model, the radius of core part was estimated as 215 nm, the shell thickness as 192 nm, and the ratio of monomer density of the shell part to that of the core part as about 0.075.

Study on Evaporation Pressure Drop of R- l34a, R-407C, and R-410A in the Oblong Shell and Plate Heat Exchanger (오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 증발 압력강하에 관한 실험적 연구)

  • 박재홍;김영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.855-862
    • /
    • 2004
  • This study reports pressure drops during evaporation for R-l34a, R-407C (a mixture of 23 wt% R-32, 25 wt% R-125, and 52 wt% R-l34A) and R-410A (a mixture of 50 wt% R-32 and 50 wt% R-125) in the oblong shell and Plate heat exchanger. The effects of the mass fluxes, heat fluxes, refrigerant saturation temperatures and vapor quality of refrigerants on the measured data were explored in detail. The present data showed that pressure drops of all refrigerants increase with the vapor quality. At a higher mass flux, pressure drops are higher for the entire range of the vapor quality A rise in the heat flux doesn't show significant effects on the pressure drops. Finally, at a higher saturation temperature the pressure drops are found to be lower. The pressure drops for R-407C were approximately 20% lower than those of R-l34a. R-410A had 33% lower pressure drops than R-l34a. Correlation is also provided for the measured pressure drops in terms of the friction factor.

THE DEVELOPMENT OF THE WATER LOADED PRESSURE METHOD FOR MEASURING EGGSHELL QUALITY

  • Kang, C.W.;Nam, K.T.;Olson, O.E.;Carlson, C.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.6
    • /
    • pp.723-726
    • /
    • 1996
  • A water loaded pressure device using water as the breaking force was developed to evaluate eggshell strength and compared with a dropping ball techniques. Further, relationships of shell thickness and weight of eggs to shell strength were also studied. Values for both of the shell strength measuring methods showed a highly significant correlation (p < 0.001) with shell thickness. The water loaded pressure method had a much higher simple correlation coefficient for shell thickness (r = + 0.786) than the dropping ball method (r = + 0.577). The shell strength measured by the water loaded pressure method appeared not to be correlated to egg weight. On the other hand, the negative sign of the standard partial regression coefficient and the partial regression coefficient of egg weight in the estimated multiple regression equation implied that for a given shell thickness a larger egg tended to have less shell strength than a smaller egg.

Study on Evaporation Heat Transfer of R-l34a, R-407C, and R-410A in the Oblong Shell and Plate Heat Exchanger (오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 증발 열전달에 관한 실험적 연구)

  • 박재홍;김영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.845-854
    • /
    • 2004
  • The evaporation heat transfer coefficient for R-l34a, R-407C (a mixture of 23wt% R-32, 25 wt% R-125, and 52 wt% R-l34a) and R-410A (a mixture of 50 wt% R-32 and 50 wt% R-125) flowing in the oblong shell and plate heat exchanger were investigated experimentally in this study. Four vertical counterflow channels were formed in the exchanger by four plates of commercial geometry with a corrugated sinusoid shape of a chevron angle of 45 degree. The effects of the mean vapor quality, mass flux, heat flux, and saturation temperature of different refrigerants on the evaporation heat transfer were explored in detail. Similar to the case of a Plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. It is found that the evaporation heat transfer coefficient in the plates is much higher than that in circular pipes. The present data show that the evaporation heat transfer coefficients of all refrigerants increase with the vapor quality. At a higher mass flux h, is higher than for the entire range of the vapor quality. Raising the imposed wall heat flux was found to slightly improve h$_{r}$, while h$_{r}$ is found to be lower at a higher refrigerant saturation temperature. A comparison of the performance of the various refrigerants reveals that R-410A has the highest heat transfer performance followed by R-l34a, and R-407C had the lowest performance of the refrigerants tested. Based on the present data, empirical correlations of the evaporation heat transfer coefficient were proposed.sed.

The Effect of Silica binder content ans Sintering condition on the Strength of Zircon-based Shell Mold (실리카 바인더 함량과 소결조건이 지르콘계 주형의 강도에 미치는 영향)

  • Kim, Jae-Won;Kim, Du-Hyeon;Kim, In-Su;Seo, Seong-Mun;Jo, Hae-Yong;Kim, Du-Su;Jo, Chang-Yong;Choe, Seung-Ju
    • Korean Journal of Materials Research
    • /
    • v.10 no.6
    • /
    • pp.415-421
    • /
    • 2000
  • The effect of silica binder content on the mechanical properties of zircon shell mold was investigated. Content of binder silica sol to refractory powder in weight[$R_W$] was adjusted from 0.18 to 0.43. Sintering of the shell mold was carried out in the temperature range of $871^{\circ}C$ to $1400^{\circ}C$. Green strength of the shell mold at room temperature increased with increasing $R_W$ and sintering temperature up to $1300^{\circ}C$. However, the mold with $R_W$ of 0.43 that sintered at $1400^{\circ}C$ for 3 hours showed relatively low strength and large level of porosity. The mechanical behavior of the shells is supposed to attributed to the difference in thermal expansion coefficient between refractory powder and binder silica. The optimum value of $R_W$ for zircon-based shell molds was found to be 0.33.

  • PDF