• 제목/요약/키워드: R&D monitoring

검색결과 587건 처리시간 0.024초

국가R&D 종합모니터링시스템 구축에 관한 연구 (A Study on Construction of Integrated National R&D Monitoring System)

  • 최기석;박만희;김영국
    • 산업경영시스템학회지
    • /
    • 제32권4호
    • /
    • pp.25-37
    • /
    • 2009
  • This Study constructs a dashboard system to synthetically and systematically monitor national R&D information based on data warehouse. Managing the national R&D statistics and trend is important since it provides data for policies and decision making for national R&D. Many agencies related to national R&D information collect the basic R&D statistic data which provides the basis of logical decision making and R&D policies. The data has not well been used. The data has not been consistently collected nor managed. The raw data has not been organized nor processed to meet various demands. The needs has been arisen for a consistent national R&D monitoring system to increase the relevance, accessibility and efficiency of data for various users. This study selects 25 key indicators based on the user requirements and designs data warehouse for supporting the indicators using star schema. The dashboard system is developed in this study provides the infrastructure of monitoring national R&D information and analytic environment of supporting statistical analysis and time-series data analysis.

무선데이타 통신을 이용한 실시간 타공사 감시 시스템 개발 (Development of Real Time Monitoring System for third party damage Detection Using Wireless Data Communicating)

  • 박승수;조성호;유휘룡;김동규;전경수;박대진;구성자;노용우
    • 한국가스학회지
    • /
    • 제4권3호
    • /
    • pp.59-64
    • /
    • 2000
  • 배관에 가해지는 충격을 실시간으로 모니터링하고, 충격위치를 산출 할 수 있는 모니터링 시스템을 무선데이타 통신을 이용하여 개발하였고, 마산만 해저배관에 현장적용 후 충격실험을 통하여 유용성을 검증하였다. 실험에 사용된 배관은 총 길이 1365m, 운용압력 8.6kgf/cm^2$$, 직경 12inch인 실제 운용중인 해저가스배관을 사용하였다. 충격실험에서 충격위치 계산오차는 배관내에서 충격음파 속도의 $1\%$정도의 거리였다.

  • PDF

태양광발전소 운영유지보수를 위한 이기종 장비 지원 모니터링 시스템 (Heterogeneous Equipment Support Monitoring System for Operation and Maintenance of Solar power plant)

  • 임수창;홍석훈;박철영;조현욱;송법성;김종찬
    • 한국멀티미디어학회논문지
    • /
    • 제23권9호
    • /
    • pp.1171-1180
    • /
    • 2020
  • The number of the PV systems installed in south korea has been gradually increasing. Interest of operation & management of PV System is rising up as PV System installation trends to increase. The vital function of operation & management is the monitoring system. Most monitoring systems are only available for equipment of suppliers and manufacturers. In this study, a monitoring system was implemented to support multi-domain equipment (inverter, junction box, water distribution board, environmental sensors) that are not limited to specific manufacturers. Monitoring system includes a visualization function, which makes it easy for users to check the power generation and the operation status of the equipment of PV System. In the future, this monitoring system will be utilized as an operation & maintenance foundation element in the PV system industry.

R&D Trends Monitoring through Scanning Public R&D Investments: The Case of Information & Communication Technology (ICT) in Meteorology and Climatology

  • Heo, Yoseob;Kim, Hyunwoo;Kim, Jungjoon;Kang, Jongseok
    • Asian Journal of Innovation and Policy
    • /
    • 제5권3호
    • /
    • pp.315-329
    • /
    • 2016
  • Public R&D investment information has diverse implications for researching R&D trends. Also, as it is important for the establishment of R&D policy to grasp the current situation and trends of R&D to improve science and technology level, science and technology information service system, such as NTIS (National Science & Technology Information Service), is operated at a national level in most countries. However, since the data forms provided by current NTIS are raw data, it is necessary to develop the R&D performance indicator or to use additional scientometric methods by analyzing scientific papers or scientific R&D project information for grasping R&D trends or analyzing R&D task results. Thus, this study applied public R&D investment information to investigate and monitor R&D trends in the field of information & communication technology (ICT) of meteorology and climatology by using NTIS data of Korea and NSF (National Science Foundation) data of USA.

지진 피해 최소화를 위한 지진 감지 시스템 개발 및 현장적용 연구 (Development of Seismic Monitoring System for Natural Gas Governor Station and It's Field Application to Minimize Earthquake Damage)

  • 유휘룡;박승수;박대진;구성자;조성호;노용우
    • 한국가스학회지
    • /
    • 제4권3호
    • /
    • pp.19-25
    • /
    • 2000
  • 지진 발생 시 일어날 수 있는 대규모 가스 폭발과 같은 2차 재앙을 미연에 방지하기 위해 천연가스 공급관리소에 설치하는 지진 감지 및 전송 시스템을 개발하였다. 천연가스 공급관리소에서 지진 감지 시스템을 효율적으로 설치하고 운용하기 위하여, 공급관리소의 지반 노이즈패턴 분석을 통하여 지반의 운동을 좀더 정밀히 계측할 수 있는 센서 설치 위치와 설치 방법을 제안하였다. 지진 발생 시 가스 차단 여부를 신속히 판단하기 위해 PGA(Peak Ground Acceleration)와 지진파가 가지는 에너지와 밀접한 연관성을 가지는 Sl(Spectrum Intensity)를 실시간으로 계산하는 알고리즘을 개발하였고 이를 지진 감지 시스템 내에 실현하였다.

  • PDF

부영양화 사전 예방을 위한 휴대용 총인 모니터링 시스템 개발 (Development of a Portable Total-phosphorus Monitoring System for Preventing Eutrophication in Advance)

  • 정동건;김승덕;권순열;이재용;김유성;이준엽;김재건;김세완;공성호;정대웅
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.342-347
    • /
    • 2020
  • In this study, a portable total-phosphorus (TP) monitoring system utilizing a photocatalytic-reaction-based pretreatment method is proposed, fabricated, and characterized. Commercial TP monitoring systems are only used in laboratories because of their complex monitoring procedure, bulk-size, and high-cost. In particular, pretreatment in commercial TP monitoring systems is performed at high temperatures (> 120 ℃) and pressure (> 1.1 kg cm-2) making it difficult to minimize the scale of the systems. The proposed TP monitoring system employs a pretreatment method with a photocatalytic reaction; thus, its size can be reduced, as photocatalytic reactions occur at room temperature and atmospheric pressure. Analytes with various TP concentrations are pretreated using the proposed portable TP monitoring system and are quantitatively measured with an LED and a photodiode.

Development of Multi-Sensor Convergence Monitoring and Diagnosis Device based on Edge AI for the Modular Main Circuit Breaker of Korean High-Speed Rolling Stock

  • Byeong Ju, Yun;Jhong Il, Kim;Jae Young, Yoon;Jeong Jin, Kang;You Sik, Hong
    • International Journal of Advanced Culture Technology
    • /
    • 제10권4호
    • /
    • pp.569-575
    • /
    • 2022
  • This is a research thesis on the development of a monitoring and diagnosis device that prevents the risk of an accident through monitoring and diagnosis of a modular Main Circuit Breaker (MCB) using Vacuum Interrupter (VI) for Korean high-speed rolling stock. In this paper, a comprehensive MCB monitoring and diagnosis was performed by converging vacuum level diagnosis of interrupter, operating coil monitoring of MCB and environmental temperature/humidity monitoring of modular box. In addition, to develop an algorithm that is expected to have a similar data processing before the actual field test of the MCB monitoring and diagnosis device in 2023, the cluster analysis and factor analysis were performed using the WEKA data mining technique on the big data of Korean railroad transformer, which was previously researched by Tae Hee Evolution with KORAIL.

광산란 계측기의 미세먼지 측정 정확도 향상을 위한 수분제거 전처리 기술 개발 (Development of Drying Systems for Accurate Measurement of Particulate Matter by means of Optical Particle Measuring Instruments)

  • 강두수;오정은;이상열;신희준;봉하경;최주현;김대성
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.191-203
    • /
    • 2018
  • IIn this study, we have developed drying systems for reducing the error by humidity on measuring particulate matter (PM) in the ambient air with optical particle measuring instruments. Two types of drying systems were designed: drying systems using heating and dilution methods. In addition, 3 types of drying systems using a heating method were designed: Type A (1 hole), B (3 holes) and C (7 holes). After making them, the laboratory and field tests were carried out to evaluate the developed drying systems. As a result, it was shown that the PM concentrations obtained by PM monitoring devices with drying systems agree well with that of the reference devices. Therefore, it could be concluded that the drying systems can be applied to PM monitoring devices for real-time monitoring of the ambient aerosols.

전력품질 감시 시스템 개발(1): 전력품질 데이터베이스 설계 (Development of Power Quality Monitoring System(PQMS) : Database Design for PQMS)

  • 김영일;방순정;한진희;윤태욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.128-130
    • /
    • 2003
  • Recently, with the increasing use of power semiconductors and microprocessors which are very sensitive to little change of power quality and power market being formed according to the reorganization of the power market, power providers and consumers show much interest in the power quality problem. This situation makes the demand creation of integrated system for power quality analysis and monitoring based on speedy and powerful functions by the growth of computer hardware and information technology, and besides advanced corporation already have created and employed power quality analysis and monitoring system. In this papers, it will be introduced that power quality database design-database is essential to integrated system-for managing effectively and confidently data from the power quality meters(PQM).

  • PDF