• Title/Summary/Keyword: R&D evaluation system

Search Result 727, Processing Time 0.03 seconds

Development of Evaluation System for Fatigue Strength on the Connection Between Longitudinals and Transverse Web (유조선 종통보강재와 횡늑골 연결부의 피로강도 평가용 자동화 시스템 개발)

  • Hong, Ki-Sup;Kim, Sung-Chan;Ahn, Jae-Wook;Kim, Seong-Ki
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.5
    • /
    • pp.510-519
    • /
    • 2009
  • Ship structure is composed of the welded mixture members which are plate and stiffeners. Ship structure is also influenced by variable loadings such as wave and inertia load. There have been several fatigue damage problems on the connection between longitudinal and transverse web due to wide usage of high tensile steel and adoption of wide web space to improve shipbuilding productivity. It is impossible to estimate the fatigue lives for all connection details through refined fatigue analysis. It is necessary to use the simplified approach for the fatigue life estimation of the connection details. PLUS analysis, which is suggested by the classification society, is one of the simplified approaches and is widely adopted to get fatigue lives for the connection details along whole cargo hold area. However, ship building yards still have difficulties to get fatigue lives due to large amount of calculation and time even if this approach reduce the time and amount of calculation. This paper treats the computing system developed to reduce efforts of estimating the fatigue lives. The influence factors of mean shear stress and local dynamic pressure are easily calculated and fatigue lives for all hot spots can be estimated automatically by the developed computing system. It is possible to reduce computing time and efforts to get the fatigue lives for the connection details between longitudinals and transverse webs along the ship. This system was applied to get fatigue lives on the connection details of a VLCC and verified the availability.

Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT (PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가)

  • Choong-Woon Lee;Yeon-Wook You;Jong-Woon Mun;Yun-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

De-NOX evaluation of SCR catalysts adding vanadium-graphene nanocomposite (바나듐 담지된 그래핀 나노복합체를 첨가한 SCR 촉매의 제조 및 활성 평가)

  • Jeong, Bora;Lee, Heesoo;Kim, Eok-Soo;Kim, HongDae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.6
    • /
    • pp.252-256
    • /
    • 2015
  • Nitrogen oxides ($NO_X$) was emitted from flue gas of stationary sources and exhaust gas of mobile sources, can leads to various environments problems. Selective Catalysts Reduction (SCR) is the most effective $NO_X$ removal system. Commercial $V_2O_5-WO_3/TiO_2$ catalysts, usually containing $V_2O_5$ 0.5~3 wt%, $WO_3$ 5~10 wt%, and $V_2O_5$ is active in the reduction of $NO_X$ but also in the desired oxidation of $SO_2$ to $SO_3$. To reduce the amount of vanadium, using graphene matrix supported vanadium to synthesize nanocomposite. Then, we fabricated to 1 inch honeycomb type of SCR catalysts adding graphene-vanadium nanocomposite. The chemical-physical characteristics and the catalytic activity were performed by XRD, XRF, BET and Micro-Reactor (MR). As a result, the De-NOX performance was showed, similar to the commercial catalyst activity as 77.8 % and using nanocomposite catalyst as 77.1 % at $350^{\circ}C$.

Properties of De/Anti-icing Fluid for High Speed Railway Rolling Stock Based on Propylene-glycol Containing Water Repellent Agent (발수 성분을 포함하는 프로필렌글리콜(PG) 기반 고속철도차량용 제·방빙액의 특성)

  • Jin-Myeong, Park;Tae-Hyun, Kim;Jung-Mu, Yang;Cha-Jung, Yun;Hong-Ki, Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.1
    • /
    • pp.69-74
    • /
    • 2023
  • As a chemical de-icing method, propylene glycol de-icing fluid is applicable for melting ice caused by snow and ice adhering to the lower part of high-speed rail rolling stock and bogie parts in winter. By spraying propylene-glycol de-icing fluid on high-speed rail rolling stock and bogie parts in advance to minimize snow adhesion, ice-melting efficiency can be further improved. In the case of high-speed rail rolling stock, even if propylene-glycol de-icing fluid is sprayed, the anti-icing performance is poor because the fluid is almost lost on the surface of the vehicle when operating at high speed. In this study, in order to prevent freezing caused by snow and ice adhering to the lower part of high-speed rail rolling stock and bogie parts, we have investigated the properties of propylene-glycol de/anti-icing fluid containing water-repellent agents that prevent surface freezing. We tried to find the optimal component for de/anti-icing fluid for high-speed rail rolling stock by evaluating the ice melting performance, contact angle, and anti-icing performance according to the types of water-repellent agent. As a result of the evaluation, it was confirmed that an de/anti-icing fluid containing an ethoxysilane-type water repellent agent was most suitable.

Systemic literature review on the impact of government financial support on innovation in private firms (정부의 기술혁신 재정지원 정책효과에 대한 체계적 문헌연구)

  • Ahn, Joon Mo
    • Journal of Technology Innovation
    • /
    • v.30 no.1
    • /
    • pp.57-104
    • /
    • 2022
  • The government has supported the innovation of private firms by intervening the market for various purposes, such as preventing market failure, alleviating information asymmetry, and allocating resources efficiently. Although the government's R&D budget increased rapidly in the 2000s, it is not clear whether the government intervention has made desirable impact on the market. To address this, the current study attempts to explore this issue by doing a systematic literature review on foreign and domestic papers in an integrated way. In total, 168 studies are analyzed using contents analysis approach and various lens, such as policy additionality, policy tools, firm size, unit of analysis, data and method, are adopted for analysis. Overlapping policy target, time lag between government intervention and policy effects, non-linearity of financial supports, interference between different polices, and out-dated R&D tax incentive system are reported as factors hampering the effect of the government intervention. Many policy prescriptions, such as program evaluation indices reflecting behavioral additionality, an introduction of policy mix and evidence-based policy using machine learning, are suggested to improve these hurdles.

Protein Evaluation of Dry Roasted Whole Faba Bean (Vicia faba) and Lupin Seeds (Lupinus albus) by the New Dutch Protein Evaluation System: the DVE/OEB System

  • Yu, P.;Egan, A.R.;Leury, B.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.6
    • /
    • pp.871-880
    • /
    • 1999
  • The effects of dry roasting (110, 130, $150^{\circ}C$ for 15, 30, 45 min) on potential ruminant protein nutritional values in terms of: a), rumen bypass protein (BCP); b), rumen bypass starch (BST); c), fermented organic matter (FOM); d), true absorbed bypass protein (ABCP); e) microbial protein synthesized in the rumen based on available energy (E_MP); f), microbial protein synthesized in the rumen based on available nitrogen (N_MP); g), true protein supplied to the small intestine (TPSI); h), true absorbed rumen synthesized microbial protein (AMP); i), endogenous protein losses (ENDP); j), true digested protein in the small intestine (DVE); k), degraded protein balance (OEB) of whole lupin seeds (WLS) and faba beans (WFB) were evaluated by the new Dutch DV/OEB protein evaluation system. Dry roasting significantly increased BCP, BST, TPSI, ABCP, DVE (p<0.001) and decreased FOM, E_MP, AMP, N_MP and OEB (p<0.001) with increasing temperatures and times except that when temperature was at $110^{\circ}C$. The values of BCP, BST, TPSI, ABCP and DVE at $150^{\circ}C/45min$ for WLS and WFB were increased 2.2, 3.7; -, 2.0; 1.7, 1.7; 2.3, 3.7 and 1.7, 1.7 times and the values of FOM, E_MP, AMP, N_MP and OEB at $150^{\circ}C/45min$ for WLS and WFB were decreased by 15.3, 25.8; 18.1, 25.8; 18.7, 25.8; 54.6, 41.6 and 82.3% 54.7%, respectively, over the raw WLS and WFB. The results indicated that though dry roasting reduced microbial protein synthesis due to reducing FOM, TPSI didn't decrease but highly increased due to increasing BCP more than enough for compensation of the microbial protein decreasing. Therefore the net absorbable DVE in the small intestine was highly increased. The OEB values were significantly reduced for both WLS and WFB but not to the level of negative. It indicated that microbial protein synthesis might not be impaired due to the sufficient N supplied in the rumen, but the high positive OEB values in the most treatments except of $150^{\circ}C$ for 30 and 45 min of WLS (The OEB values: 54.8 and 26.0 g/kg DM) indicated that there were the large amounts of N loss in the rumen. It was concluded that dry roasting at high temperature was effective in shifting protein degradation from rumen to intestines and it increased the DVE values without reaching the negative OEB values. No optimal treatment was found in WLS due to the too high OEB values in all treatments. But dry roasting at $150^{\circ}C$ for 30 and 45 min might be optimal treatments for WLS due to the very lower OEB values.

A Study on the Performance Evaluation Index of Multi-Water Resources Connection and Continuous Utilization in Micro Water Grid (마이크로 워터 그리드에서 다중수원 연계·연속 활용 성능평가지표에 관한 연구)

  • Chae, Soo-Kwon;Lee, Sang-Hoon;Ah, Hong-Kyu
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.556-567
    • /
    • 2019
  • As the number of skyscrapers in micro water grid units such as green building and smart building is increasing in the world, the green building certification system is being implemented to solve problems such as increased demand for water resources and energy. However, researches on the use of sustainable water resources like water reuse and water conservation through linkage and continuous use of water resources, while the power and energy sectors are actively conducting R&D projects in the green building certification system on the micro water grid level. Therefore, this paper analyzes the characteristics and limitations of the water resources sector for the continuous utilization of multiple water sources in the green building certification system, due to the inadequate consideration of sustainability. Then investigates whether various water resources such as constants, nature, and alternative water resources are continuously used in and out of the green building or smart building and complex in the micro water grid unit to suggest evaluation methods and performance evaluation standards.

A Study on Land Warrior System Design Based on IEEE 802.15.4 (IEEE 802.15.4 기반의 미래병사체계 시스템 설계에 관한 연구)

  • Heo, Jun;Lee, Sang-Jin;Choi, Yong-Hoon;Choi, Hyo-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.5
    • /
    • pp.71-80
    • /
    • 2012
  • In this paper, applications that require low-speed data rate on personal area network to operate the Land Warrior system is proposed. These applications can refer to WSN(wireless sensor network) technology. However, this technology is not suitable to support various data transmission rate. A suitable CSMA/CA algorithm for Land Warrior System in order to solve these existing system problems is proposed. The proposed algorithm is designed to be variable CSMA/CA algorithm parameter, depending on data rate. For the evaluation of Land Warrior system model and CSMA/CA algorithm, we used Castalia. As a result of the simulation, it is found that the proposed system model can not only relieve loads of data processing, but also probability of collision was decreased.

Evaluation of electron dose distribution obtained from ADAC Pinnacle system against measurement and Monte Carlo method for breast patients

  • Lee, S.;Lee, R.;Park, D.;S. Suh
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.82-82
    • /
    • 2003
  • Introduction: With the development of dose calculation algorithms for electron beams, 3D RTP systerns are available for electron beam dose distribution commercially. However, no studies evaluated the accuracy of dose calculation with ADAC Pinnacle system for electron beams. So, the accuracy of the ADAC system is investigated by comparing electron dose distributions from ADAC system against the BEAMnrc/DOSXYZnrc. Methods: A total of 33 breast cancer patients treated with 6, 9, and 12MeV electrons in our institution was selected for this study. The first part of this study is to compare the dose distributions of measurement, TPS and the BEAMnrc/DOSXYZnrc code in flat water phantom at gantry zero position and for a 10 ${\times}$ 10 $\textrm{cm}^2$ field. The second part is to evaluate the monitor unit obtained from measurement and TPS. Adding actual breast patient's irregular blocks to the first part, monitor units to deliver 100 cGy to the dose maximum (dmax) were calculated from measurement and 3D RTP system. In addition, the dose distributions using blocks were compared between TPS and the BEAMnrc/DOSXYZnrc code. Finally, the effects of tissue inhomogeneities were studied by comparing dose distributions from Pinnacle and Monte Carlo method on CT data sets. Results: The dose distributions calculated using water phantom by the TPS and the BEAMnrc/ DOSXYZnrc code agreed well with measured data within 2% of the maximum dose. The maximum differences of monitor unit between measured and Pinnacle TPS in flat water phantom at gantry zero position were 4% for 6 MeV and 2% for 9 and 12 MeV electrons. In real-patient cases, comparison of depth doses and lateral dose profiles calculated by the Pinnacle TPS, with BEAMnrc/DOSXYZnrc code has generally shown good agreement with relative difference less than +/-3%. Discussion: For comparisons of real-patient cases, the maximum differences between the TPS and BEAMnrc/DOSXYZnrc on CT data were 10%. These discrepancies were due in part to the inaccurate dose calculation of the TPS, so that it needs to be improved properly. Conclusions: On the basis of the results presented in this study, we can conclude that the ADAC Pinnacle system for electron beams is capable of giving results absolutely comparable to those of a Monte Carlo calculation.

  • PDF

Pharmacokinetic Evaluation and Gastric Ulcer Symptoms comparison of Ketorolac Tromethamine Sustained-Release Pellets after Oral Administration in Beagle Dogs (비글견을 이용한 케토롤락트로메타민 서방형 펠렛 제제의 위궤양 증상 비교와 약물속도론적 평가)

  • Yoon, Yang-No;Kim, Su-Ji;Jung, Suk-Hyun;Kim, Hyo-Jeong;Park, Eun-Seok;Hwang, Sung-Joo;Lee, Yong-Won;Seong, Ha-Soo;Shin, Byung-Cheol;Cho, Sun-Hang
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.6
    • /
    • pp.401-409
    • /
    • 2009
  • Ketrorolac tromethamine (KT), a nonsteroidal anti-inflammatory drug (NSAID) is required repeated administration due to its short blood half-life. To avoid dose-dependent side effects of KT, sustained-release pellets containing KT were prepared by coating with Eudragit$^{(R)}$ RS 100 and Eudragit$^{(R)}$ NE 30D. The in vitro and in vivo drug release behavior of KT from Eudragit$^{(R)}$ RS 100 and NE 30D coated pellet (SR-A), Eudragit$^{(R)}$ RS 100 coated pellet (SR-B) and conventional commercial immediate-release tablet (IR) was investigated. KT from SR-A and SR-B was slowly released over several hours, whereas IR showed rapid initial release in vitro. The pharmacokinetic study in vivo was performed by oral administration in beagle dogs. 5 mg IR was administered 3 times at intervals 5 hr. Five milligrams of IR was administered 3 times at intervals of 5 hr and 15 mg of SR-A and SR-B did once. After administering IR, KT concentration in blood showed high peak- trough fluctuation and stomach ulcer were discovered. On the other hand, SR-A and SR-B sustainedly released KT and reduced the occurrence of stomach ulcer. There sustained-release pellets will be effective system to minimize dosedependent of side effect and improve patient compliance.