• 제목/요약/키워드: Quench time

검색결과 91건 처리시간 0.025초

고온 초전도 퓨즈의 한류 및 방전 특성 (Current Limiting and Discharge Characteristics of High Tc Superconductive Fuse)

  • 최효상
    • 한국전기전자재료학회논문지
    • /
    • 제17권6호
    • /
    • pp.673-677
    • /
    • 2004
  • We present the basic properties of a superconductive fuse (SF) based on YBCO/Au films. The SF consists of YBCO stripes covered with Au layers for current shunt. The fault current was limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enabled the SF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.age.

댐퍼의 두께와 재질 변화에 따른 초전도 선재에 미치는 자장특성 분석 (Analysis of Magnetic Field of Superconducting Winding According to the Changed Damper Thickness and Material)

  • 정재식;이상호;홍정표;조영식
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.5-8
    • /
    • 2012
  • Superconducting windings of synchronous machine have to be operated in below the critical temperature, critical current density and critical magnetic field. If one of these characteristics does not satisfied, then the quench occurred in superconducting winding. Especially the armature current dramatically increased as the superconducting generator is short-circuited at the rated load condition and magnetic field in field winding increased due to the armature current. Therefore, damper is required to reduce the magnetic field of field winding which increases reliability of the superconducting generator. Damper dimension can be decided by time constant[1-2]. In this paper the basic model is high-power and low-speed superconducting generator. Damper time constant was calculated from the changed damper thickness and material. Magnetic flux of field coil at the basic model and changed damper time constant model is analyzed.

고온 초전도 한류퓨즈의 전압별 동작특성 (Operating characteristics of high Tc superconducting current limiting fuse at various voltages)

  • 최효상;현옥배;김혜림;황시돌;박권배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.161-163
    • /
    • 2001
  • We present the basic properties of a superconducting current limiting fuse (SCLF) based on YBCO/Au films. The SCLFs consists of YBCO stripes covered with Au layers for current shunt. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.

  • PDF

초전도소자의 트리거를 이용한 초전도 전류제한기의 전류제한 및 회복특성 분석 (Analysis on Current Limiting and Recovery Characteristics of a SFCL using a Trigger of Superconducting Element)

  • 임성훈
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.112-116
    • /
    • 2010
  • 본 논문에서는 고장발생 초기에 초전도 전류제한기를 구성하는 초전도 소자의 ��치발생을 검출하여 고장전류의 경로를 별도의 상전도 전류제한기로 우회시킴으로써 초전도 전류제한기의 회복시간을 단축시킬 수 있는 초전도소자의 트리거를 이용한 초전도 전류제한기의 전류제한 및 회복특성에 대해 분석하였다. 고장전류 크기를 조절하기 용이한 구성요소로 상전도 전류제한기의 저항크기에 따른 초전도 전류제한기를 구성하고 있는 전력용스위치의 개방시점과 투입시점의 변화를 비교하였으며, 분석을 통해 상전도 전류 제한기의 저항이 증가할수록 초전도 전류제한기를 구성하는 전력용스위치의 복귀시간이 길게 나타남을 확인할 수 있었다.

영덕 서부 지품화산암층의 SHRIMP U-Pb 연대측정과 화산과정 (SHRIMP U-Pb Dating and Volcanic History of the Jipum Volcanics, Western Yeongdeok, Korea)

  • 황상구
    • 암석학회지
    • /
    • 제26권4호
    • /
    • pp.341-352
    • /
    • 2017
  • 영덕 서부에서 산출되는 지품화산암층은 하부로부터 유문암질 화성쇄설암, 층회암, 안산암질 유리쇄설암, 유문암 용암, 응회질 역암, 안산암 용암 순으로 구성되는 층서단위이다. 유문암질 화성쇄설암은 SHRIMP U-Pb 연대측정에 의해 $68.5{\pm}1.6Ma$로 측정되었다. 이 층서단위는 이 무렵에 대부분 유문암질 화산작용에 의해 형성되었으며 국부적이지만 다른 화구로부터 안산암질 화산작용에 의해 추가되었다. 유문암질 화산작용은 먼저 수증기마그마성 폭발작용으로 인해 화성쇄설층을 형성시켰고, 나중에 유문암질 화산작용이 재개되어 기존 화구로부터 용암 분류작용으로 유문암질 용암돔을 형성하였다. 1차 및 2차 유문암질 화산작용 사이에 화산 말단부의 낮은 저지는 침수되어 층회암층이 퇴적되었고 연이어 다른 화구에서 안산암질 화산작용이 일어나 흘러나온 용암이 호수물과의 접촉에 의해 급냉파쇄작용으로 유리쇄설암을 형성하였으며, 마지막으로 다시 안산암질 용암이 재차 흘러들어와 지품화산을 얇은 안산암 용암층으로 덮었다.

무유도성 초전도전류제한기의 특성 해석 및 컴퓨터 시뮬레이션 (The Computer Simulation on the Characteristics of the Non-Inductive Superconducting Fault Current Limiter)

  • 주민석;이상진;오윤상;고태국
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1050-1060
    • /
    • 1994
  • This paper is a study on the computer simulation of the characteristics of the superconducting fault current limiter. Input variable parameters are apparent power, load resistance value, line resistance value and so on. Initial fault current 2 times larger than the trigger current is required to reduce the switching time of SFCL. The propagation velocity increases abruptly, the transport current is several times larger than the ciritical current. In this paper, the switching time is calculated to be 323$\mu$ sec, and the initial fault current is 19 times larger than the critical current. Because the trigger coils are bifilar winding, they have little impedance in superconducting state. After fault occurred, the limiting coil acts as a superconducting reactor and the trigger coils quench at a critical current. Without the SFCL in the circuit, fault current after the load impedence is shorted might be increased to 1100A. The fault current is, therefore, successfully limited by the superconducting limiting coil to 100A determined by the coil inductance.

  • PDF

Single-stranded DNA Enhances the Rate of Product Release During Nucleotide Hydrolysis Reaction by T7 DNA Helicase

  • Kim, Dong-Eun;Jeong, Yong-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권10호
    • /
    • pp.1618-1622
    • /
    • 2006
  • Bacteriophage T7 gp4A' is a ring-shaped hexameric DNA helicase that catalyzes duplex DNA unwinding using dTTP hydrolysis as an energy source. To investigate the effect of single-stranded DNA (ssDNA) on the kinetic pathway of dTTP hydrolysis by the T7 DNA helicase complexed with ssDNA, we have first determined optimal concentration of long circular M13 single-stranded DNA and pre-incubation time in the absence of $Mg^{2+}$ which is necessary for the helicase-ssDNA complex formation. Steady state dTTP hydrolysis in the absence of $Mg^{2+}$ by the helicase-ssDNA complex provided $k_{cat}$ of $8.5\;{\times}\;10^{-3}\;sec^{-1}$. Pre-steady state kinetics of the dTTP hydrolysis by the pre-assembled hexameric helicase was monitored by using the rapid chemical quench-flow technique both in the presence and absence of M13 ssDNA. Pre-steady state dTTP hydrolysis showed distinct burst kinetics in both cases, indicating that product release step is slower than dTTP hydrolysis step. Pre-steady state burst rates were similar both in the presence and absence of ssDNA, while steady state dTTP hydrolysis rate in the presence of ssDNA was much faster than in the absence of ssDNA. These results suggest that single-stranded DNA stimulates dTTP hydrolysis reaction by T7 helicase by enhancing the rate of product release step.

단일 가열봉의 재관수 시 2상유동 및 벽면 열전달에 관한 실험적 연구 (Experimental investigation of two-phase flow and wall heat transfer during reflood of single rod heater)

  • 박영재;김형대
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.23-34
    • /
    • 2020
  • Two-phase flow and heat transfer characteristics during the reflood phase of a single heated rod in the KHU reflood experimental facility were examined. Two-phase flow behavior during the reflooding experiment was carefully visualized along with transient temperature measurement at a point inside the heated rod. By numerically solving one-dimensional inverse heat conduction equation using the measured temperature data, time-resolved wall heat flux and temperature histories at the interface of the heated rod and coolant were obtained. Once water coolant was injected into the test section from the bottom to reflood the heated rod of >700℃, vast vapor bubbles and droplets were generated near the reflood front and dispersed flow film boiling consisted of continuous vapor flow and tiny liquid droplets appeared in the upper part. Following the dispersed flow film boiling, inverted annular/slug/churn flow film boiling regimes were sequentially observed and the wall temperature gradually decreased. When so-called minimum film boiling temperature reached, the stable vapor film between the heated rod and coolant was suddenly collapsed, resulting in the quenching transition from film boiling into nucleate boiling. The moving speed of the quench front measured in the present study showed a good agreement with prediction by a correlation in literature. The obtained results revealed that typical two-phase flow and heat transfer behaviors during the reflood phase of overheated fuel rods in light water nuclear reactors are well reproduced in the KHU facility. Thus, the verified reflood experimental facility can be used to explore the effects of other affecting parameters, such as CRUD, on the reflood heat transfer behaviors in practical nuclear reactors.

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권6호
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

크기가 다른 박막형 초전도 한류소자에서의 저항 분포 (Resistance distribution in SFCLs of two different sizes)

  • 김혜림;차상도;최효상;황시돌;현옥배;오제명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.281-284
    • /
    • 2002
  • We investigated quench distribution in SFCLs of two different sizes. YBa$_2$Cu$_3$O$_{7}$ films coated in-situ with a gold layer were patterned into meander lines of two different sizes by photolithography. The limiters were tested with simulated fault currents at various source voltages. The values of resistivity and their time dependence were similar at similar electric fields. The resistivity was nearly uniform except at the edges in both smaller and larger SFCLs. In particular, the resistivity gradient was smaller in larger SFCLs. However, differences between stripe resistivities were larger in larger SFCLs. The results were quantitatively explained with a heat transfer concept.t.

  • PDF