• 제목/요약/키워드: Quasi-resonant

검색결과 141건 처리시간 0.033초

Vertical vibrations of a multi-span beam steel bridge induced by a superfast passenger train

  • Klasztorny, M.
    • Structural Engineering and Mechanics
    • /
    • 제12권3호
    • /
    • pp.267-281
    • /
    • 2001
  • Transient and quasi-steady-state vertical vibrations of a multi-span beam steel bridge located on a single-track railway line are considered, induced by a superfast passenger train, moving at speed 120-360 km/h. Matrix dynamic equations of motion of a simplified model of the system are formulated partly in the implicit form. A recurrent-iterative algorithm for solving these equations is presented. Excessive vibrations of the system in the resonant zones are reduced effectively with passive dynamic absorbers, tuned to the first mode of a single bridge span. The dynamic analysis has been performed for a series of types of bridges with span lengths of 10 to 30 m, and with parameters closed to multi-span beam railway bridges erected in the second half of the $20^{th}$ century.

Internal pressure dynamics of a leaky and quasi-statically flexible building with a dominant opening

  • Guha, T.K.;Sharma, R.N.;Richards, P.J.
    • Wind and Structures
    • /
    • 제16권1호
    • /
    • pp.61-91
    • /
    • 2013
  • An analytical model of internal pressure response of a leaky and quasi-statically flexible building with a dominant opening is provided by including the effect of the envelope external pressure fluctuations on the roof, in addition to the fluctuating external pressure at the dominant opening. Wind tunnel experiments involving a flexible roof and different building porosities were carried out to validate the analytical predictions. While the effect of envelope flexibility is shown to lower the Helmholtz frequency of the building volume-opening combination, the lowering of the resonant peak in the internal and net roof pressure coefficient spectra is attributed to the increased damping in the system due to inherent background leakage and envelope flexibility. The extent of the damping effects of "skin" flexibility and background leakage in moderating the internal and net pressure response under high wind conditions is quantified using the linearized admittance functions developed. Analytical examples provided for different combinations of background leakage and envelope flexibility show that alleviation of internal and net pressure fluctuations due to these factors by as much as 40 and 15% respectively is possible compared to that for a nominally sealed rigid building of the same internal volume and opening size.

RCD 스너버 및 준구형파를 이용한 250[W] HPS lamp용 전자석 안정기 개발 (The Development Of the Electronic Ballast for HPS lamp using the RCD Snubber and Quasi-Square Wave)

  • 강도형;박종연
    • 조명전기설비학회논문지
    • /
    • 제16권2호
    • /
    • pp.18-25
    • /
    • 2002
  • 본 논문은 고압 방전램프를 점등시켜 주는 전자식 안정기에 관한 것으로서, Class D LCC 공진 인버터 방식을 이용하여, 램프의 초기 점등, 정상상태를 구동하게 하고, 준구형파로 ZC-ZVS Soft Switching을 구현하여 풀-브리지 스위치의 발열을 최소화할 수 있도록 하였다. 또한, RCD 스너버 회로를 적용하여 스위치 발열 감소뿐만 아니라, 고주파 스위칭으로 인한 서지 전압의 감소를 통한 노이즈를 최소화시켜 제어부의 안정되고, 신뢰성 있는 동작을 가능하게 할 수 있도록 하고, 안정기의 전체적인 스위칭 노이즈 발생을 최소화하였다.

단일 전력변환 준-공진형 플라이백 컨버터 (Single Power-processing Quasi-resonant Flyback Converter)

  • 차우준;조용원;권봉환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.192-193
    • /
    • 2013
  • 본 논문에서는 단일 전력변환 준-공진 플라이백 컨버터를 제안한다. 제안된 컨버터는 기존의 플라이백 컨버터로 구성되며 별도의 역률 개선 회로를 사용하지 않고 새로운 제어 알고리즘을 이용하여 고역률을 구현한다. 또한 준-공진을 이용하여 소프트 스위칭을 함으로써 스위칭 손실을 최소화한다. 제안된 회로의 동작원리와 제어 알고리즘을 설명하고, 최종적으로 90W급 전원회로의 시작품을 제작하여 실험을 통해 제안하는 회로의 이론적 해석을 검증한다.

  • PDF

유도가열 부하를 갖는 인버터 회로의 해석에 관한 연구 (The Analysis of Inverter Circuit with Induction Heating Load)

  • 노희석;권경안;양우종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.424-427
    • /
    • 1995
  • This paper proposes an analysis of an inverter circuit which has an induction heating load. Two major kinds of the inverters are E-class quasi resonant and half-bridge type. The analyses of induction heating load property and operation property are introduced. A simulation program which implements those properties is also introduced. The results of the simulation program are verified through experimental results.

  • PDF

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

Utility Interactive Solar Power Conditioner with Zero Voltage Soft Switching High frequency Sinewave Modulated Inverter Link

  • Terai H.;Sumiyoshi S.;Kitaizumi T.;Omori H.;Ogura K.;Chandhaket S.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.668-672
    • /
    • 2001
  • The utility interactive sinewave modulated inverter for the solar photovoltaic (PV) power conversion and conditioning with a new high frequency pulse modulated link is presented for domestic residential applications. As compared with the conventional full-bridge hard switching PWM inverter with a high frequency AC link, the simplest single-ended quasi-resonant soft switching sinewave modulated inverter with a duty cycle pulse control is implemented, resulting in size and weight reduction and low-cost. This paper presents a prototype circuit of the single-ended zero voltage soft switching sinewave inverter for solar power conditioner and its operating principle. In addition, this paper proposes a control system to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed from an experimental point of view. A newly developed interactive sinewave power processor which has $92.5\%$ efficiencty at 4kW output is demonstrated. It is designed 540mm-300mm-125mm in size, and 20kg in weight.

  • PDF

초고주파 유전체공진기의 복소유전율 측정 (Microwave Measurement of Complex Permittivity of Dielectric Resonators)

  • 김정필;박위상
    • 대한전자공학회논문지
    • /
    • 제27권11호
    • /
    • pp.9-19
    • /
    • 1990
  • 원통형 및 환형 유전체공진기의 복소유전율과 투자율을 측정하기 위한 이론적인 해석과 측정방법을 제시하였다. 두 개의 평면도체 사이에 유전체공진기를 놓고 공진주파수와 무부하 Q, 그리고 치수를 측정하면 복소유전율과 투자율을 구할 수 있으며 이 방법을 고차모우드에 대하여 반복적으로 행하면 더 넓은 주파수 범위에서 측정이 가능하다. 이 때 각각의 공진모우드는 유전체공진기의 방위각과 축방향에 대한 전계 세기의 변화를 측정함으로써 결정할 수 있다. 그리고 여러가지 오차의 요인들을 고려한 측정오차의 해석으로부터 $TE_{0np}$ 또는 quasi-TE 모우드를 측정에 이용할 경우 복소유전율의 실수부분은 $0.5{\%}$, 허수부분은 $4{\%}$ 이내의 측정오차를 가짐이 밝혀졌다.

  • PDF

내부 손실이 고려된 LLC 공진형 하프브릿지 컨버터의 정상상태 특성에 관한 연구 (A Study on Steady State Characteristics of LLC Resonant Half Bridge Converter Considering Internal Losses)

  • 안태영
    • 전기전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.985-991
    • /
    • 2018
  • 본 논문에서는 LLC 공진형 하프브릿지 컨버터의 내부손실이 반영된 등가회로를 제안하고, 손실 요소가 포함된 정상상태 특성식을 유도하였다. 그 결과를 이용하여 입출력 전압이득과 입력 임피던스의 주파수 특성을 무손실 모델과 비교하였다. 제안한 모델과 유도식을 검증하기 위해서 최대 전력이 1kW급인 LLC 공진형 하프브릿지 컨버터의 전원장치의 주요 소자를 동일한 조건에서 선정하여 전압이득과 입력 임피던스와 같은 정상상태 특성을 비교하였다. 특히 두 가지 모델에 대한 정상상태 오차를 보다 면밀하게 비교하기 위해서 실제 회로 설계 단계에서 가장 중요하게 고려되는 부하 전류에 대한 스위칭 주파수의 변화를 관찰 하였다. 그 결과 본 논문에서 제안한 모델과 해석 결과로부터 동작 주파수의 오차가 상당 부분 개선되었다는 것을 확인 하였다.

Wind induced internal pressure overshoot in buildings with opening

  • Guha, T.K.;Sharma, R.N.;Richards, P.J.
    • Wind and Structures
    • /
    • 제16권1호
    • /
    • pp.1-23
    • /
    • 2013
  • The wind-induced transient response of internal pressure following the creation of a sudden dominant opening during the occurrence of high external pressure, in low-rise residential and industrial buildings was numerically investigated. The values of the ill-defined parameters namely the flow contraction coefficient, loss coefficient and the effective slug length were calibrated by matching the analytical response with the computational fluid dynamics predictions. The effect of a sudden i.e., "instantaneously created" windward opening in the Texas Technical University (TTU) test building envelope was studied for two different envelope flexibility-leakage combinations namely: (1) a quasi-statically flexible and non-porous envelope and (2) a quasi-statically flexible and porous envelope. The responses forced by creating the openings at different time leads/lags with respect to the occurrence of the peak external pressure showed that for cases where the openings are created in close temporal proximity to the peak pressure, the transient overshoot values of internal pressure could be higher than the peak values of internal pressure in the pre-sequent or subsequent resonant response. In addition, the influence of time taken for opening creation on the level of overshoot was also investigated for the TTU building for the two different envelope characteristics. Non-dimensional overshoot factors are presented for a variety of cavity volume-opening area combinations for (1) buildings with rigid/quasi-statically flexible non-porous envelope, and (2) buildings with rigid/quasi-statically flexible and porous envelope (representing most low rise residential and industrial buildings). While the factors appear slightly on the high side due to conservative assumptions made in the analysis, a careful consideration regarding the implication of the timing and magnitude of such overshoots during strong gusts, in relation to the steady state internal pressure response in cyclonic regions, is warranted.