• 제목/요약/키워드: Quasi steady state

검색결과 159건 처리시간 0.353초

포항 호미곶의 풍환경 분석 (Analysis of Wind Environments at Homi-Cape, Pohang)

  • 김현구;최재우;정우식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.451-454
    • /
    • 2002
  • In the present paper, the practicability of Commentray on Wind Loads of Korean Standard Design Loads fur Buildings, which has been enacted in Minstry of Construction and Transportation in June 2000, is validated by using the meteorological data measured at Homi-Cape, Pohang. Assuming that the vertical wind profile follows the power-law in a quasi-steady state, wind profile exponents are calculated by seasons by using wind data as collected through four monitoring towers. According to the Commentray on Wind Loads, Pohang is classified with its exposure category being B and the wind profile exponent being 0.22, while it is identified that the average wind profile exponent as calculated in this study is 0.26. Also, in this paper, a cross-correlation method is suggested in order to identify any meteorological correlation between measurement sites quantitatively.

  • PDF

공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법 (Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber)

  • 정은수
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF

HWCVD 패시베이션 층을 적용한 이종접합 태양전지 제작 (Fabrication of heterojunction silicon solar cell using HWCVD passivation layer)

  • 강민구;탁성주;이승훈;김찬석;정대영;이정철;김동환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.370-370
    • /
    • 2009
  • 이종접합태양전지는 구조적 대칭성 때문에 웨이퍼 두께가 감소하여도 보우잉이 일어나지 않는 특징이 있으며, 산요에서 개발한 이종접합태양전지의 효율이 22% 이상을 보이고 있다. 이종접합태양전지에서 비정질 실리콘과 실리콘 웨이퍼의 계면에 따라 이종접합태양전지의 특성이 크게 변화한다. 본 연구에서는 패시베이션 층으로 사용되는 비정질 실리콘을 hot wire chemical vapor deposition(HWCVD)을 사용하여 이종접합태양전지에 적용하였으며 기존의 plasma-enhanced chemical vapor deposition을 이용한 비정질 실리콘을 적용한 이종접합태양전지와 비교하였다. 패시베이션 특성을 확인하기 위해 quasi-steady state photoconductance로 minority carrier lifetime을 측정하였고, 태양전지 특성평가로는 암전류특성 및 광전류특성을 사용하였다. HWCVD를 사용하여 패시베이션한 태양전지의 경우 16.1%의 효율을 보였다.

  • PDF

Quasi-steady State Simulation of Rotating Detonation Engine

  • Niyasdeen, Mohammed;Oh, Sejong;Kim, Kui Soon;Choi, Jeong-Yeol
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권4호
    • /
    • pp.548-559
    • /
    • 2015
  • We performed a numerical simulation based on the two-dimensional (2-D) unsteady Euler's equation with a single-step Arrhenius reaction model in order to investigate the detonation wave front propagation of an Argon (Ar) diluted oxy-hydrogen mixture ($2H_2+O_2+12Ar$). This simulation operates in the detonation frame of reference. We examine the effect of grid size and the performance impact of integrated quantities such as mass flow. For a given set of baseline conditions, the minimal and maximum grid resolutions required to simulate the respective detonation waves and the detonation cell structures are determined. Tertiary shock wave behavior for various grids and pre-exponential factors are analyzed. We found that particle fluctuation can be weakened by controlling the mass flow going through the oblique shock waves.

특이섭동방식을 이용한 비선형 적응제어에 관한 연구 (Adaptive controller design for nonlinear systems Using Singular perturbation Method)

  • 김도우;이형찬;양해원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.685-688
    • /
    • 1997
  • In this paper, we introduce a new adaptive controller for induction motor based on singular perturbation theory. The design of 5th induction motor was changed for the 3rd modeling using the singular perturbation method. The resulting boundary layer and quasi-steady-state systems are made exponentially stable. Therefore the statements of Tychonov's theorm are valid for an infinite time interval for induction motor, too.

  • PDF

유한요소법에 의한 PREFLEX BEAM의 용접열분포 특성에 관한 연구 (A Study on the Numerical Analysis of Welding Heat Distribution of Preflex Beam)

  • 방한서;주성민;김하식
    • 한국해양공학회지
    • /
    • 제18권2호
    • /
    • pp.52-57
    • /
    • 2004
  • Preflex beam is a method of construction designed to hold the pre-compressive stresses over the concrete pier by the preflexion load. During the fabrication of the girder, welding causes residual stresses. The welding residual stresses must be relieved in order to generate the accurate compressive pre-stresses. In this study, to determine the thermal distribution characteristics on the girder by welding, both three-dimensional finite element analysis and two-dimensional finite element analysis, in a quasi-steady state, is carried out. After comparing each result between the three-dimensional analysis and the two-dimensional analysis, finite element analysis is carried out against the actual girder, and the welding thermal distribution characteristic over the preflex beam is analyzed. It is possible to provide the input data for the analysis of the welding residual stresses.

미지의 회전자 저항을 갖는 유도기의 적응 자속 관측자 설계 (An Adaptive Flux Observer of Induction Motors with Unknown Rotor Resistance)

  • 김도우;양해원;윤지섭;박병석;김홍필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.438-441
    • /
    • 1998
  • In this paper, we proposes an adaptive flux observer to estimate initial values of rotor fluxes and unknown rotor resistance. The error system between the model of induction motor and a proposed observer is devided as a fast subsystem and a slow one by a singular perturbation system. The fast subsystem is exponentially convergent on a boundary-layer. And the overall error system is reduced to a quasi-steady-state system. The adaptive law for an unknown rotor resistance is designed to stabilize the approximate error system. As computer simulation results show, the proposed adaptive flux observer estimates fast initial values of rotor fluxes and unknown rotor resistance.

  • PDF

공조 시스템용 DDC의 온라인 최적제어에 관한 연구

  • 안병천
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1072-1078
    • /
    • 2001
  • The real time optimal control algorithm of the DDC controller for chilled water and supply air temperature set-point of heating, ventilating, air-conditioning and refrigeration systems has been researched for minimization of the total power which is consumed by the chiller, chilled water pump and air handing unit fan. The study has been done by using TRNSYS program in order to analyze the central cooling system in terms of the environmental variables such as indoor cooling lead and wet-bulb temperature. This optimal control alogorithm saves more energy and is suitable for real time on-line control in comparison with conventional method.

  • PDF

Digital Controller Candidate for Point-of-load Synchronous Buck Converter in Tri-mode Mechanism

  • Xiu, Li-Mei;Zhang, Wei-Ping;Li, Bo;Liu, Yuan-Sheng
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.796-805
    • /
    • 2014
  • A digital controller with a low-power approach for point-of-load synchronous buck converters is discussed and compared with its analog counterpart to confirm its feasibility for system integration. The tri-mode digital controller IC in $0.35{\mu}m$ CMOS process is presented to demonstrate solutions that include a PID, quarter PID, and robust RST compensators. These compensators address the steady-state, stand-by, and transient modes according to the system operating point. An idle-tone free condition for ${\Sigma}-{\Delta}$ DPWM reduces the inherent tone noise under DC-excitation. Compared with that of the traditional approach, this condition generates a quasi-pure modulation signal. Experimental results verify the closed-loop performances and confirm the power-saving mechanism of the proposed controller.

PCV(Positive Crankcase Ventilation) 밸브의 유동특성에 관한 수치해석 (Computational Analysis of Flow Characteristics of a PCV Valve)

  • 이종훈;최윤환;이연원
    • 한국자동차공학회논문집
    • /
    • 제13권4호
    • /
    • pp.66-73
    • /
    • 2005
  • A great deal of exhaust gas inside a combustion room goes out through exhaust pipe. But residual gas 'Blowby gas' enters the crankcase through a small gap between the piston and the cylinder wall. Here, if the blowby gas isn't vented, this causes many bad efffcts such as lubricant oil contamination, corrosion by that and crankcase explosion by rising pressure. So most automobiles are constituted with a PCV(Positive Crankcase Ventilation) system to prevent previous problems. PCV valve is the most important part in this ventilation system. When companies are manufacturing new cases, engineers are designing it depending on their experiments than theoretical knowledges. Much efforts and times are needed for new development. This study will show quantitative results to increase the possibilities for the optimal design.