• Title/Summary/Keyword: Quartz Crystal Microbalance

Search Result 150, Processing Time 0.026 seconds

The Theory and Application or Piezoelectric Quartz Crystal Microbalance[PZ QCM] for Biosensor (압전 수정 결정 미량 천평[PZ QCM] 바이오센서의 원리와 응용)

  • 김의락
    • KSBB Journal
    • /
    • v.18 no.2
    • /
    • pp.79-89
    • /
    • 2003
  • This article contains an overview of acoustic wave devices, the theory and application of piezoelectric quartz crystal microbalances(PZ QCM), clinical analysis, gas phase detection, DNA biosensors, drug analysis, food microbial analysis and environmental analysis.

Measurement of Toluene Solubility in PVAc Using a Quartz Crystal Microbalance (PVAc에서 Quartz Crystal Microbalance를 이용한 톨루엔의 용해도 측정에 관한 연구)

  • Kim, S.B.
    • Elastomers and Composites
    • /
    • v.43 no.3
    • /
    • pp.166-172
    • /
    • 2008
  • The resistance and frequency change of a quartz crystal microbalance during toluene absorption was measured for poly(vinyl acetate) (PVAc) with 268 nm thickness. Solubility of toluene in PVAc were measured at temperatures from 25$^{\circ}C$ to 42$^{\circ}C$ and pressures up to 28.4 torr. The frequency of a quartz crystal microbalance increased with increasing temperature and decreased with an increase in toluene vapor pressure. The resistance of a quartz crystal microbalance increased with increasing toluene vapor pressure and decreased with an increase in temperature. A greater pressure of toluene results in a greater solubility of the toluene into the PVAc film. The change of solubility was calculated by Sauerbrey equation.

Development of Quartz Crystal Microbalance-Based Immunosensor for the Determination of Low-Density Lipoprotein (Quartz Crystal Microbalance 시스템을 이용한 저밀도 지질단백질측정용 면역센서의 개발)

  • 김상현;윤현철;감학성
    • KSBB Journal
    • /
    • v.13 no.4
    • /
    • pp.337-342
    • /
    • 1998
  • Immunosensor for the determination of LDL(Low-Density Lipoprotein), a good indicator for the diagnosis of atherosclerosis and hypercholesterolemia, was developed by using quartz crystal microbalance(QCM). The immunosensor consists of flow-through cell, oscillating circuit, oscilloscope, and frequency counter. FIA(Flow Injection Analysis) was applied to the QCM system for the measurement of LDL in liquid phase. Antibody showing binding affinity against LDL was immobilized on the gold electrode of a quartz crystal by covalent coupling via polyethylenimine / glutaredehyde. LDL was injected and bound to the antibody immobilized on the QCM immunosensor. The response of the immunosensor (F0 - F1) was found to be proportional to the LDL concentration from 200 $\mu\textrm{g}$/ml to 800 $\mu\textrm{g}$/ml. Operational conditions for the operation of immunosensor were also investigated in terms of sensitivity and non-specific binding.

  • PDF

The Impedance Properties of Quartz Crystal Microbalance Coated with LB films (LB막을 누적한 수정진동자의 임피던스 특성)

  • 진철남;김경환;유승엽;박재철;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.171-174
    • /
    • 1998
  • Quartz crystal in contact with viscoelastic medium is described directly in terms of the electrical equivalent circuit of the system. Stearic acid is used as viscoelastic medium and deposited on the surface of quartz crystal using the Langmuir-Blodgett(LB) method. Impedance properties of quartz crystal coated with LB films which were investigated and the possibility of applying the technique to chemical sensing introduced.

  • PDF

Measurement of Water Absorption in Anticorrosive Organic Coatings Using Quartz Crystal Microbalance (QCM) (수정진동자 미세저울을 이용한 방식도막의 물 흡수 측정)

  • 이근대;도윤정;김진호;박성수;홍성수;서차수;박진환
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.6
    • /
    • pp.77-82
    • /
    • 2003
  • The absorption of water into an anti-corrosive organic coating, such as alkyd and urethane resin coating, was investigated, using a quartz crystal microbalance (QCM). Anticorrosive properties of the coatings were also measured, by means of electrochemical impedance spectroscopy (EIS). The overall absorption of water in the coating is determined by the chemical nature of resin, and decreases with increasing thickness. The enhancement of anti-corrosive performance, through increase of coating thickness, was more remarkable in the case of the coating that hadlower equilibrium water absorption. The absorption kinetics curves were Fickian in nature. The EIS analysis confirmed that the resin, having lower equilibrium water absorption, shows higher anti-corrosive performan.

Detection of human and bovine haptoglobin by using quartz crystal microbalance sensor chip containing secondary antibody (이차항체를 포함하는 수정미소저울 센서 칩을 이용한 사람과 소의 헵토글로빈 측정)

  • Kim, Sung-Il;Ha, In-Young;Choi, Suk-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.160-167
    • /
    • 2009
  • In this study, secondary antibody-containing quartz crystal microbalance(QCM) sensor chip was prepared and utilized for the detection of human and bovine haptoglobin. Anti-goat immunoglobulin G antibody, which is a secondary antibody capable of capturing primary antibodies raised in goat, was immobilized through the reaction between hydrazide and aldehyde group prepared on the QCM surface and antibody respectively. The resulting sensor chip showed higher stability in the repeated surface regeneration with acidic dissociation solution as well as requiring lower amount of primary antibody when compared to the protein G sensor chip. The secondary antibody sensor chip was applied for the estimation of bovine and human haptoglobin.

Short Review on Quartz Crystal Microbalance Sensors for Physical, Chemical, and Biological Applications

  • Il Ryu, Jang;Hoe Joon, Kim
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.389-396
    • /
    • 2022
  • Quartz crystal microbalance (QCM) based sensors are used for various applications owing to advantages such as excellent accuracy and precision, rapid response, and tiny footprint. Traditional applications of QCM-based sensors include biological sensing and thin-film thickness monitoring. Recently, QCMs have been used as functional material for novel physical and chemical detections, and with improved device design. QCM-based sensors are garnering considerable attention in particulate matter sensing and electric nose application. This review covers the challenges and solutions in physical, chemical, and biological sensing applications. First, various physical sensing applications are introduced. Secondly, the toxic gas and chemical detection studies are outlined, focusing on introducing a coating method for uniform sensing film and sensing materials for a minimal damping effect. Lastly, the biological and medical sensing applications, which use the monomolecularly decorating method for biomolecule recognition and a brief description of the overall measuring system, are also discussed.

Construction of Low Noise Electrochemical Quartz Crystal Microbalance

  • Hwang, Ui Jin;Im, Yeong Ran
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.1
    • /
    • pp.39-42
    • /
    • 1996
  • A new oscillator for electrochemical quartz crystal microbalance (EQCM) was developed by using an operational amplifier without any LC component. The home-made EQCM using this oscillator showed only 0.02 Hz frequency noise at 0.3 s gate time when a 6 MHz AT-cut crystal was used. Pb underpotential deposition on gold substrate in nitric acid media was examined to demonstrate the performance of this EQCM. The derivative of frequency change could be obtained without averaging multiple scans.

Electrochemical Reactions of $C_{60}$ Films in the Presence of Water : An Electrochemical Quartz Crystal Microbalance Study

  • 서경자;신명순;전일철
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.9
    • /
    • pp.781-786
    • /
    • 1996
  • Mass transport behavior of C60 films on electrodes with different thicknesses has been studied by an Electrochemical Quartz Crystal Microbalance (EQCM) during electrochemical reduction-oxidation processes in the presence of water. C60 films were found to be reduced in the presence of water and they remains quite stable. In thin films, the mass on electrode decreased after a complete cycle while X-ray Photoelectron Spectroscopy (XPS) study does not support the existence or formation of C60-epoxides during electrochemical reduction processes in the presence of water or oxygen.

QCM Study of β-Casein Adsorption on the Hydrophobic Surface: Effect of Ionic Strength and Cations

  • Lee, Myung-Hee;Park, Su-Kyung;Chung, Chin-Kap;Kim, Hack-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.7
    • /
    • pp.1031-1035
    • /
    • 2004
  • The adsorption kinetics of ${\beta}$-casein on a hydrophobic surface has been studied by means of the quartz crystal microbalance (QCM). The self assembled monolayer of 1-octadecanethiol on a gold coated quartz crystal was used as a hydrophobic surface for adsorption. The adsorption kinetics was monitored in different solution conditions. Formation of monolayer is observed in most cases. At high concentration of protein, micelle formation which is interrupted by high ionic strength of solution is observed. Casein binding cations such as $Ca^{2+},\;Ba^{2+}\;and\;Al^{3+}$ increase the hydrophobicity of the protein and the multiple layer adsorption occurs. The strong and weak points of the QCM method in the study of protein adsorption are discussed.