• Title/Summary/Keyword: Quantitative sodium analysis

Search Result 70, Processing Time 0.023 seconds

Hepatotoxic mechanism of diclofenac sodium on broiler chicken revealed by iTRAQ-based proteomics analysis

  • Sun, Chuanxi;Zhu, Tianyi;Zhu, Yuwei;Li, Bing;Zhang, Jiaming;Liu, Yixin;Juan, Changning;Yang, Shifa;Zhao, Zengcheng;Wan, Renzhong;Lin, Shuqian;Yin, Bin
    • Journal of Veterinary Science
    • /
    • v.23 no.4
    • /
    • pp.56.1-56.17
    • /
    • 2022
  • Background: At the therapeutic doses, diclofenac sodium (DFS) has few toxic side effects on mammals. On the other hand, DFS exhibits potent toxicity against birds and the mechanisms remain ambiguous. Objectives: This paper was designed to probe the toxicity of DFS exposure on the hepatic proteome of broiler chickens. Methods: Twenty 30-day-old broiler chickens were randomized evenly into two groups (n = 10). DFS was administered orally at 10mg/kg body weight in group A, while the chickens in group B were perfused with saline as a control. Histopathological observations, serum biochemical examinations, and quantitative real-time polymerase chain reaction were performed to assess the liver injury induced by DFS. Proteomics analysis of the liver samples was conducted using isobaric tags for relative and absolute quantification (iTRAQ) technology. Results: Ultimately, 201 differentially expressed proteins (DEPs) were obtained, of which 47 were up regulated, and 154 were down regulated. The Gene Ontology classification and Kyoto Encyclopedia of Genes and Genomes pathway analysis were conducted to screen target DEPs associated with DFS hepatotoxicity. The regulatory relationships between DEPs and signaling pathways were embodied via a protein-protein interaction network. The results showed that the DEPs enriched in multiple pathways, which might be related to the hepatotoxicity of DFS, were "protein processing in endoplasmic reticulum," "retinol metabolism," and "glycine, serine, and threonine metabolism." Conclusions: The hepatotoxicity of DFS on broiler chickens might be achieved by inducing the apoptosis of hepatocytes and affecting the metabolism of retinol and purine. The present study could provide molecular insights into the hepatotoxicity of DFS on broiler chickens.

A Study on the Constituents of Pyrolusitum by XRD and XRF (XRD와 XRF를 이용한 무명이(無名異)의 구성 성분 연구)

  • Lee, Minwoo;Choi, Goya;Lee, Young-Jong
    • The Korea Journal of Herbology
    • /
    • v.33 no.6
    • /
    • pp.87-92
    • /
    • 2018
  • Objectives: The aim of the study was to analyze the constituents of Pyrolusitum, which was used to eliminate static blood and inflammation, to establish the basis of clinical application. Methods: Qualitative analysis was performed by X-Ray Diffraction (XRD) using the sample as a powder, and the elemental content of granular sample was measured by X-Ray Fluorescence (XRF). 1 M hydrochloric acid and 5% sodium hydroxide aqueous solution were added to observe the changing shape, respectively. Results: Qualitative analysis by XRD revealed that the Pyrolusitum samples used in the study contained quarts and kaolinite. Quantitative analysis by XRF revealed that the manganese content in the samples used in the study was 6.16% on average, while iron was contained the highest amount of 22.99%. The minor constituents include 1.08% of titanium, 0.30% of barium, 0.18% of lead, 0.06% of zirconium, 0.05% of chromium, 0.04% of zinc, 0.03% of cadnium, 0.02% of nickel, 0.01% of arsenic, 0.01% of copper, 0.01% of rubidium, 0.01% of strontium, 0.00% of molybdenum, respectively. And cobalt, which is reported to be a constituent of Pyrolusitum, was not detected at all in the samples of the study. Pyrolusitum was dissolved in dark brown when it was put into 1 M hydrochlorid acid, and there was brown precipitate when sodium hydroxide solution was added to Pyrolusitum and stirred. Conclusions: It was found that manganese and iron were the major constituents of Pyrolusitum, and it could be identified by using concentrated hydrochloric acid and sodium hydroxide solution.

The Effect of Filter Paper on the Results of Trace Analysis (거름종이가 미량 분석 결과에 미치는 영향)

  • Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.174-178
    • /
    • 2003
  • Analytical chemists frequently use filter papers during the course of experiments without any hesitation. However, the results of analysis could be deteriorated by the various ions which are extracted from filter papers. In some filter paper made for qualitative use, about $300{\mu}g$ sodium and many other cations were detected. Although the quantities of contaminants was low in the filter paper made for quantitative use, significant amount of Fe, Si, Al, Cu and Zn was detected as well as alkali element. Many cations and anions were also detected in the filtrate obtained from the glass fiber filter.

Analysis of Inorganic Anions in Various Drinking Waters by Capillary Electrophoresis

  • Choi, One-Kyun;Cho, Jae-Sun
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.835-841
    • /
    • 1995
  • The quantitation of inorganic anions in various drinking waters were investigated using capillary electrophoresis(CE) and the results were compared with ion chromatography(IC). With CE, in contrast to IC, was demonstrated rapid analysis, good efficiency, a low detection limit and the low comsumption of a solvent and samples. CE analysis was used 5 mM sodium chromate(pH 8.0) containing 20 mM tetraalkylammoniumbromide at -25kV applied voltage with indirect UV detection at 254 nm. This results in exceedingly short analysis time within 3 min. with efficiencies approaching 200,000 theoretical plates. The coefficients of variants of migration time are less than 0.8% and those of peak area are less than 2.3%. Detection limits for quantitative determination were 300 ppb-50 ppm level. These optimum conditions are applicable to various samples without pretreatment.

  • PDF

A study on the analysis of artificial sweeteners in processed foods including emulsified foods by HPLC-DAD

  • Kim, Min-Hee;Lee, Do-Yeon;Ahn, Jang-Hyuk
    • Analytical Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.209-214
    • /
    • 2020
  • This study has been carried out to develop a standard method for quantifying of 3 permitted artificial sweeteners (including sodium saccharine, aspartame, acesulfame potassium) contained in foods by HPLC-DAD. A simple and rapid sample pretreatment method was used to remove fat and protein from the test solution with Carrez clearing regent precipitant know to be effective for protein and fat removal. The artificial sweeteners in the test solution purified through sample pretreatment were detected by high performance liquid chromatograph using a Reverse phase C18 column (5 ㎛, 4.6 × 250 mm). The simultaneous quantitative test of 3 kinds of artificial sweeteners can be effectively performed on the high fat emulsified foods containing a large amount of fat. Using the established simultaneous quantitative test method, artificial sweeteners were tested in foods such as dairy products, snacks and chocolate. The results calibration curve showed good linearity with high regression coefficients and the result of recovery test showed satisfactory recoveries within 80~110 %.

Determination of Sodium Chondroitin Sulfate by Enzymatic Digestion and HPLC (효소분해와 HPLC를 이용한 황산콘드로이틴나트륨의 정량)

  • Kang, Seong-Ho;Shin, Hoon;Chang, Sun-Ki;Yoon, Hyung-Jung
    • Analytical Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.245-251
    • /
    • 1994
  • In order to determine sodium chondroitin sulfate in the mixture, chondroitinase ABC was used for enzymatic reaction. The procedure was rapid, simple, quantitative and the HPLC analysis of ${\Delta}Di-6S$(2-actamido-2-deoxy-3-0-(${\beta}$-D-gluco-4-enepyranosyluronic acid)-6-0-sulfo-D-galactose) in the sodium chondroitin sulfate was obtained. The absorbance was measured at 230nm and detection limit was $1{\mu}g/ml$. When we applied this method to the drugs(capsule, opthalmic solution), it gave the mean contents of $100.01{\pm}1.58%$ and $99.89{\pm}1.80%$ respectively.

  • PDF

Analysis of Water-soluble Vitamins in Pharmaceutical Products by Capillary Electrophoresis (모세관 전기영동법을 이용한 제제중의 수용성 비타민 분석)

  • Lee, Jong-Jin;Moon, Dong-Cheul;Lee, Kong-Joo
    • YAKHAK HOEJI
    • /
    • v.38 no.1
    • /
    • pp.38-45
    • /
    • 1994
  • An analytical method using capillary electrophoresis (CE) was developed for quantitation of water soluble vitamin contents in various vitamin products. The method includes the optimization of separation of 11 water soluble vitamins changing the micellar concentration and pH of running buffer, applied voltage and sample preparation. Best resolution was obtained with 25 mM phosphate buffer (pH=8.0) containing 50 mM sodium dodecyl sulphate (SDS) as micellar phase. At optimum condition, water soluble vitamins were determined in orange juice and vitamin products such as vitamin C pulvis, vitamin injection, coated multivitamin tablet. The quantitative analysis of water soluble vitamins with CE was suitable for quality control of pharmaceutical products with sound reproducibility.

  • PDF

Development of objective indicators for quantitative analysis of sodium intake: the sodium to potassium ratio of second-void urine is correlated with 24-hour urinary sodium excretion

  • Kim, Jung Gon;Han, Sang-Woong;Yi, Joo Hark;Park, Hyeong Cheon;Han, Sang Youb
    • Nutrition Research and Practice
    • /
    • v.14 no.1
    • /
    • pp.25-31
    • /
    • 2020
  • BACKGROUND/OBJECTIVES: To date, sodium intake has been evaluated based on spot urine instead of 24-hour (hr) urine collection. Nevertheless, the optimal method for assessing daily sodium intake remains unclear. SUBJECTS/METHODS: Fifteen male (age 32.7 ± 6.5 years) participants were offered 3 meals with a total of 9-10 g salt over 24 hours, and 24-hr urine was collected from the second-void urine of the first day to the first-void urine of the second day. Twenty-four-hr urinary sodium (24UNa) was estimated using Tanaka's equation and the Korean formula, and spot urine Na, potassium (K), chloride (Cl), urea nitrogen (UN), creatinine (Cr), specific gravity (SG) and osmolality (Osm) were measured. The ratios of urinary Na to other parameters were calculated, and correlations with total measured 24UNa were identified. RESULTS: Average 24-hr urine volume was 1,403 ± 475 mL, and measured 24UNa was 143.9 ± 42.1 mEq (range, 87.1-239.4 mEq). Measured 24UNa was significantly correlated with urinary Na/UN (r = 0.560, P < 0.01), urinary Na/Osm (r = 0.510, P < 0.01), urinary Na/Cr (r = 0.392, P < 0.01), urinary Na/K (r = 0.290, P < 0.01), 24UNa estimated using Tanaka's equation (r = 0.452, P < 0.01) and the Korean formula (r = 0.414, P < 0.01), age (r = 0.548, P < 0.01), weight (r = 0.497, P < 0.01), and height (r = 0.393, P < 0.01) in all spot urine samples. Estimated 24UNa based on the second-void spot urine of the first day tended to be more closely correlated with measured 24UNa than were estimates from the other spot urine samples. The significant parameters correlated with the second-void urine of the first day were urinary Na/K (r = 0.647, P < 0.01), urinary Na/Cr (r = 0.558, P < 0.05), and estimated 24UNa using Tanaka's equation (r = 0.616, P < 0.05) and the Korean formula (r = 0.588, P < 0.05). CONCLUSIONS: Second-void urine is more reliable than first-void urine for estimating 24UNa. Urinary Na/K in the second-void urine on the first day is significantly correlated with 24UNa. Further studies are needed to establish the most reliable index and the optimal time of urine sampling for predicting 24UNa.

Effects of Procedures for Preparing Fatty Acid Methyl Esters on Fatty Acid Composition of Korean Vegetable Oils (Sesame Seed Oils) (지방산 메틸에스테르 조제방법이 한국산 식물성 기름(참깨 기름)의 지방산 조성에 미치는 영향)

  • Yoon, Tai-Heon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.9-18
    • /
    • 1987
  • The effects of procedures for preparation of fatty acid methyl esters for gas chromatography were investigated. A quantitative comparison of four procedures for the preparation of the fatty acid methyl esters from Korean sesame seed lipids which can be representative of fatty acid ranges of Korean vegetable oils has been made. The procedures employed were $BF_3$-methanol, HCI-methanol, sodium methoxide-methanol, and tetramethylammonium hydroxide-methanol. Twelve fatty acids ranged from 14:0 to 24:0 were identified in the lipids from Korean white and black sesame seeds. All four procedures gave similar results for the fatty acids, 16:0, 18:0, 18:1, 18:2, and 18:3 present in the range of $1{\sim}44%$ but only in the HCI-methanol procedure, the fatty acids, 16:1, 20:0, 22:0, 24:0 present in the range of $0.02{\sim}1%$ showed the lowest values. When using tetramethylammonium hydroxide-methanol procedure for determination of total fatty acid composition from white and black sesame seed lipids, unsaponifiable matters including sesamol, sesamolin and sesamin present in the seed lipids are not removed from the resulting reaction mixture. Thus the transesterification mixture is used without further treatment for injection into the gas chromatography. However, the gas chromatographic analysis of the transesterification mixture showed that the unsaponifiable matters had no effect on the fatty acid composition of the seed lipids. From the results, it appears that the $BF_3$-methanol, sodium methoxide-methanol and tetramethylammonium hydroxide-methanol procedures can be used to prepare fatty acid methyl esters from Korean vegetable oils. Among the methods, the tetramethylammonium hydroxide-methanol procedure, which give total fatty acid composition, glyceride fatty acid composition and composition of free fatty acids present, appears to be a simple, convenient and quantitative procedure and applicable to samples containing broad ranges of fatty acids.

The Evaluation of Solid-Phase Microextraction(SPME) Techniques for Analyzing Mixed Fuel Oxygenates and Products

  • 이재선;이시진;장순웅
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.458-461
    • /
    • 2003
  • Solid-phase microextraction (SPME) and gas chromatography/headspace techniques(HS) and flame ionization detection (GC/FID) have been combined for determination of very polar compounds in water, including the widely used gasoline oxygenates and by-products. A relatively simple extraction method using a CAR/PDMS(75${\mu}{\textrm}{m}$) SPME fiber was optimized for the routine analysis of gasoline oxygenates and by-products in groundwater and reagent water. A sodium chloride concentration of 25%(w/w) combined with an extraction time of 20 min provided the greatest sensitivity while maintaining analytical efficiency Replicate analyses in fortified reagent and groundwater spiked with microgram per liter concentrations of gasoline oxygenates and by-products indicate quantitative and reproducible recovery of these and related oxygenate compounds. Method dynamic range was 50$\mu\textrm{g}$ L-1 to 3000$\mu\textrm{g}$ L-1 for gasoline oxygenates and by-products.

  • PDF