• Title/Summary/Keyword: Quantitative CT

Search Result 345, Processing Time 0.03 seconds

Quantitative Analysis of ${\mu}$-CT about Neo-Bone Regeneration on Mouse Calvarial Defected Model (신생 뼈의 재생에 관한 마우스 두개골 결손모델 시 마이크로 시티의 정량적 분석법)

  • Jung, Hong-Moon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • Bone is so crucial anatomy for human body. Many researchers study deep into a subject about bone regeneration. There is no standard analysis for quantitative Neo-bone regeneration on calvarial defected model. Micro CT is so useful method to quantitative analysis of Neo-bone regeneration. This study was show that how to quantitative analysis of Neo-bone regeneration with ${\mu}-CT$ Micro CT was possible to quantitative analysis for Neo-bone regeneration on Calvarial defected model. futhermore Not only was Micro CT possible for qualitative analysis but quantitative analysis on the mouse calvarial model. This study will provide bone biology researchers with accurate quantitative analysis.

  • PDF

Use of Quantitative CT to Predict Postoperative Lung Function (Comparison of Quantitative CT and Perfusion Lung Scan) (폐절제술후의 폐기능 예측에 대한 나선식 정량적 CT의 유용성 (나선식 정량적 CT와 폐관류스캔과의 비교))

  • 이조한
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.798-805
    • /
    • 2000
  • Background : the prediction on changes in the lung function after lung surgery would be an important indicator in terms of the operability and postoperative complications. In order to predict the postoperative FEV1 - the commonly used method for measuring changes in lung function- a comparison between the quantitative CT and the perfusion lung scan was made and proved its usefulness. Material and Method : The subjects included 22 patients who received perfusion lung scan and quantitative CT preoperatively and with whom the follow-up of PFT were possibles out of the pool of patients who underwent right lobectomy or right pneumonectomy between June of 1997 and December of 1999. The FEV1 and FVC were calibrated by performing the PFT on each patient and then the predicted FEV1 and FVC were calculated after performing perfusion lung scan and quantitative CT postoperatively. The FEV1 and FVC were calibrated by performing the PFT after 1 week and after 3 momths following the surgery. Results : There was a significant mutual scan and the actual postoperative FEV1 and FVC at 1 week and 3 months. The predicted FEV1 and FVC(pneumonectomy group : r=0.962 and r=0.938 lobectomy group ; r=0.921 and r=913) using quantitative CT at 1 week postoperatively showed a higher mutual relationship than that predicted by perfusion lung scan(pneumonectomy group : r=0.927 and r=0.890 lobectomy group : r=0.910 and r=0.905) The result was likewise at 3 months postoperatively(CT -pneumonectomy group : r=0.799 and r=0.882 lobectomy group : r=0.934 and r=0.932) Conclusion ; In comparison to perfusion lung scan quantitative CT is more accurate in predicting lung function postoperatively and is cost-effective as well. Therefore it can be concluded that the quantitative CT is an effective method of replacing the perfusion lung scan in predicting lung function post-operatively. However it is noted that further comparative analysis using more data and follow-up studies of the patients is required.

  • PDF

Relationship between 18F-FDG PET/CT Semi-Quantitative Parameters and International Association for the Study of Lung Cancer, American Thoracic Society/European Respiratory Society Classification in Lung Adenocarcinomas

  • Lihong Bu;NingTu;Ke Wang;Ying Zhou;Xinli Xie;Xingmin Han;Huiqin Lin;Hongyan Feng
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.112-123
    • /
    • 2022
  • Objective: To investigate the relationship between 18F-FDG PET/CT semi-quantitative parameters and the International Association for the Study of Lung Cancer, American Thoracic Society/European Respiratory Society (IASLC/ATS/ERS) histopathologic classification, including histological subtypes, proliferation activity, and somatic mutations. Materials and Methods: This retrospective study included 419 patients (150 males, 269 females; median age, 59.0 years; age range, 23.0-84.0 years) who had undergone surgical removal of stage IA-IIIA lung adenocarcinoma and had preoperative PET/CT data of lung tumors. The maximum standardized uptake values (SUVmax), background-subtracted volume (BSV), and background-subtracted lesion activity (BSL) derived from PET/CT were measured. The IASLC/ATS/ERS subtypes, Ki67 score, and epidermal growth factor/anaplastic lymphoma kinase (EGFR/ALK) mutation status were evaluated. The PET/CT semi-quantitative parameters were compared between the tumor subtypes using the Mann-Whitney U test or the Kruskal-Wallis test. The optimum cutoff values of the PET/CT semi-quantitative parameters for distinguishing the IASLC/ATS/ERS subtypes were calculated using receiver operating characteristic curve analysis. The correlation between the PET/CT semi-quantitative parameters and pathological parameters was analyzed using Spearman's correlation. Statistical significance was set at p < 0.05. Results: SUVmax, BSV, and BSL values were significantly higher in invasive adenocarcinoma (IA) than in minimally IA (MIA), and the values were higher in MIA than in adenocarcinoma in situ (AIS) (all p < 0.05). Remarkably, an SUVmax of 0.90 and a BSL of 3.62 were shown to be the optimal cutoff values for differentiating MIA from AIS, manifesting as pure ground-glass nodules with 100% sensitivity and specificity. Metabolic-volumetric parameters (BSV and BSL) were better potential independent factors than metabolic parameters (SUVmax) in differentiating growth patterns. SUVmax and BSL, rather than BSV, were strongly or moderately correlated with Ki67 in most subtypes, except for the micropapillary and solid predominant groups. PET/CT parameters were not correlated with EGFR/ALK mutation status. Conclusion: As noninvasive surrogates, preoperative PET/CT semi-quantitative parameters could imply IASLC/ATS/ERS subtypes and Ki67 index and thus may contribute to improved management of precise surgery and postoperative adjuvant therapy.

Quantitative Evaluation of CT Artifact Elimination with various Cut-off Frequency of Hann Filter (Hann 필터의 Cut-off 주파수 변화에 따른 CT 영상의 Artifact 제거효과에 대한 정량적 평가)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.5-9
    • /
    • 2008
  • In the computerized tomography(CT), various filters are using in the reconstruction algorithm to reduce or eliminate the artifacts which are intrinsically induced by the imperfection of mathematical methods for reconstruction, lack of real informations about anatomic structures in the projection image, errors in data acquisition and so on. Hann filter was used to evaluate the filter effects on the elimination of reconstruction artifact in the CT image. The quantitative study was done by changing cut-off frequency of Hann filter from 0.1 to 0.9 with frequency increasement by 0.2. NPS analysis was fulfilled for the quantitative evaluation of filter effect.

  • PDF

Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation

  • Kim, Yeon Soo;Kim, Se Hyung;Ryu, Hwa Sung;Han, Joon Koo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1077-1088
    • /
    • 2018
  • Objective: To correlate CT parameters on detector-based dual-energy CT enterography (DECTE) with Crohn's disease activity index (CDAI) and externally validate quantitative CT parameters. Materials and Methods: Thirty-nine patients with CD were retrospectively enrolled. Two radiologists reviewed DECTE images by consensus for qualitative and quantitative CT features. CT attenuation and iodine concentration for the diseased bowel were also measured. Univariate statistical tests were used to evaluate whether there was a significant difference in CTE features between remission and active groups, on the basis of the CDAI score. Pearson's correlation test and multiple linear regression analyses were used to assess the correlation between quantitative CT parameters and CDAI. For external validation, an additional 33 consecutive patients were recruited. The correlation and concordance rate were calculated between real and estimated CDAI. Results: There were significant differences between remission and active groups in the bowel enhancement pattern, subjective degree of enhancement, mesenteric fat infiltration, comb sign, and obstruction (p < 0.05). Significant correlations were found between CDAI and quantitative CT parameters, including number of lesions (correlation coefficient, r = 0.573), bowel wall thickness (r = 0.477), iodine concentration (r = 0.744), and relative degree of enhancement (r = 0.541; p < 0.05). Iodine concentration remained the sole independent variable associated with CDAI in multivariate analysis (p = 0.001). The linear regression equation for CDAI (y) and iodine concentration (x) was y = 53.549x + 55.111. For validation patients, a significant correlation (r = 0.925; p < 0.001) and high concordance rate (87.9%, 29/33) were observed between real and estimated CDAIs. Conclusion: Iodine concentration, measured on detector-based DECTE, represents a convenient and reproducible biomarker to monitor disease activity in CD.

CT Quantitative Analysis and Its Relationship with Clinical Features for Assessing the Severity of Patients with COVID-19

  • Dong Sun;Xiang Li;Dajing Guo;Lan Wu;Ting Chen;Zheng Fang;Linli Chen;Wenbing Zeng;Ran Yang
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.859-868
    • /
    • 2020
  • Objective: To investigate the value of initial CT quantitative analysis of ground-glass opacity (GGO), consolidation, and total lesion volume and its relationship with clinical features for assessing the severity of coronavirus disease 2019 (COVID-19). Materials and Methods: A total of 84 patients with COVID-19 were retrospectively reviewed from January 23, 2020 to February 19, 2020. Patients were divided into two groups: severe group (n = 23) and non-severe group (n = 61). Clinical symptoms, laboratory data, and CT findings on admission were analyzed. CT quantitative parameters, including GGO, consolidation, total lesion score, percentage GGO, and percentage consolidation (both relative to total lesion volume) were calculated. Relationships between the CT findings and laboratory data were estimated. Finally, a discrimination model was established to assess the severity of COVID-19. Results: Patients in the severe group had higher baseline neutrophil percentage, increased high-sensitivity C-reactive protein (hs-CRP) and procalcitonin levels, and lower baseline lymphocyte count and lymphocyte percentage (p < 0.001). The severe group also had higher GGO score (p < 0.001), consolidation score (p < 0.001), total lesion score (p < 0.001), and percentage consolidation (p = 0.002), but had a lower percentage GGO (p = 0.008). These CT quantitative parameters were significantly correlated with laboratory inflammatory marker levels, including neutrophil percentage, lymphocyte count, lymphocyte percentage, hs-CRP level, and procalcitonin level (p < 0.05). The total lesion score demonstrated the best performance when the data cut-off was 8.2%. Furthermore, the area under the curve, sensitivity, and specificity were 93.8% (confidence interval [CI]: 86.8-100%), 91.3% (CI: 69.6-100%), and 91.8% (CI: 23.0-98.4%), respectively. Conclusion: CT quantitative parameters showed strong correlations with laboratory inflammatory markers, suggesting that CT quantitative analysis might be an effective and important method for assessing the severity of COVID-19, and may provide additional guidance for planning clinical treatment strategies.

Assessment of the Severity of Coronavirus Disease: Quantitative Computed Tomography Parameters versus Semiquantitative Visual Score

  • Xi Yin;Xiangde Min;Yan Nan;Zhaoyan Feng;Basen Li;Wei Cai;Xiaoqing Xi;Liang Wang
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.998-1006
    • /
    • 2020
  • Objective: To compare the accuracies of quantitative computed tomography (CT) parameters and semiquantitative visual score in evaluating clinical classification of severity of coronavirus disease (COVID-19). Materials and Methods: We retrospectively enrolled 187 patients with COVID-19 treated at Tongji Hospital of Tongji Medical College from February 15, 2020, to February 29, 2020. Demographic data, imaging characteristics, and clinical data were collected, and based on the clinical classification of severity, patients were divided into groups 1 (mild) and 2 (severe/critical). A semiquantitative visual score was used to estimate the lesion extent. A three-dimensional slicer was used to precisely quantify the volume and CT value of the lung and lesions. Correlation coefficients of the quantitative CT parameters, semiquantitative visual score, and clinical classification were calculated using Spearman's correlation. A receiver operating characteristic curve was used to compare the accuracies of quantitative and semi-quantitative methods. Results: There were 59 patients in group 1 and 128 patients in group 2. The mean age and sex distribution of the two groups were not significantly different. The lesions were primarily located in the subpleural area. Compared to group 1, group 2 had larger values for all volume-dependent parameters (p < 0.001). The percentage of lesions had the strongest correlation with disease severity with a correlation coefficient of 0.495. In comparison, the correlation coefficient of semiquantitative score was 0.349. To classify the severity of COVID-19, area under the curve of the percentage of lesions was the highest (0.807; 95% confidence interval, 0.744-0.861: p < 0.001) and that of the quantitative CT parameters was significantly higher than that of the semiquantitative visual score (p = 0.001). Conclusion: The classification accuracy of quantitative CT parameters was significantly superior to that of semiquantitative visual score in terms of evaluating the severity of COVID-19.

Motion Correction in PET/CT Images (PET/CT 영상 움직임 보정)

  • Woo, Sang-Keun;Cheon, Gi-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.172-180
    • /
    • 2008
  • PET/CT fused image with anatomical and functional information have improved medical diagnosis and interpretation. This fusion has resulted in more precise localization and characterization of sites of radio-tracer uptake. However, a motion during whole-body imaging has been recognized as a source of image quality degradation and reduced the quantitative accuracy of PET/CT study. The respiratory motion problem is more challenging in combined PET/CT imaging. In combined PET/CT, CT is used to localize tumors and to correct for attenuation in the PET images. An accurate spatial registration of PET and CT image sets is a prerequisite for accurate diagnosis and SUV measurement. Correcting for the spatial mismatch caused by motion represents a particular challenge for the requisite registration accuracy as a result of differences in PET/CT image. This paper provides a brief summary of the materials and methods involved in multiple investigations of the correction for respiratory motion in PET/CT imaging, with the goal of improving image quality and quantitative accuracy.

Phantom of the AAPM CT imaging evaluation Studies on the quantitative analysis method (CT 정도관리 영상의 정량적 분석방법에 관한 연구)

  • Kim, Young-su;Ko, Seong-Jin;Kang, Se-Sik;Ye, Soo-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.271-274
    • /
    • 2016
  • CT quality assurance imaging evaluation and enforcement as quantitative assessment by phantom image evaluation, assessment items include There are also contrasting the water attenuation coefficient, uniformity, noise, resolution, spatial resolution, 10mm slice thickness evaluation, contrast resolution, space for the resolution, the slice thickness evaluation, it is possible to estimate the error due to the evaluation by the subjective judgment of the tester, using a subjective error image processing program to be computed to minimize the objective evaluation. Basic recording conditions of the CT image quality control assessment is the same as special medical equipment quality control checks, the images were evaluated quantitatively using IMAGE J. For a CT attenuation coefficient, the uniformity, noise evaluation, were evaluated as CT quality control image the standard deviation of the measured value of the digital processing of image smaller and less noise uniform images than the, contrast and resolution assessment is the size of the diameter of a circle having a large the 1 inch, 0.75 inch, 0.5 inch quality if the diameter of the circle, was evaluated in the small circle in the near circle ellipse. Spatial resolution is evaluated by using a self-extracting features of an image processing program, all of the groups of members comprising the acceptance criteria to automatically extract, was evaluated to be very useful for the quantitative assessment. When CT image quality control assessment on the basis of the results such as the above, if using an image processing program to minimize the subjective judgment of the error evaluator and is determined more efficient than would be made quantitative evaluation.

  • PDF