• Title/Summary/Keyword: Quality of needle

Search Result 170, Processing Time 0.028 seconds

Improved DNA Extraction Method for Molecular Diagnosis from Smaller numbers of Cells

  • Oh, Seo Young;Han, Jeong Yeon;Lee, So Ra;Lee, Hoon Taek
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.46 no.3
    • /
    • pp.99-105
    • /
    • 2014
  • Isolating total DNA from small samples using traditional methods is difficult and inefficient mainly due to loss of DNA during filtration and precipitation. With advances in molecular pathology, DNA extraction from micro-dissected cells has become essential in handling clinical samples. Genomic DNA extraction using small numbers of cells can be very important to successfully PCR amplify DNA from small biopsy specimens. We compared our experimental genomic DNA extraction method (A) with two other commercially available methods: using spin columns (B), and conventional resins (C), and determined the efficacy of DNA extraction from small numbers of cells smeared on a glass slide. Approximately 50, 100, 200, 500 and 1000 cells were isolated from fine needle aspiration biopsy (FNAB) slides aspirated from histologically proven papillary thyroid carcinoma masses. DNA was extracted using the three techniques. After measuring DNA quantity, PCR amplification was performed to detect the ${\beta}$-globin and $BRAF^{V600E}$ gene mutations. DNA extracted by method (A) showed better yield than the other methods in all cell groups. With our method, a suitable amount of genomic DNA to produce amplification was extracted from as few as 50 cells, while more than 100 to 200 cells were required when methods (B) or (C) were applied. Our genomic DNA extraction method provides high quality and improved yields for molecular analysis. It will be especially useful for paucicellular clinical samples which molecular pathologists often confront when handling fine needle aspiration cytology, exfoliative cytology and small biopsy specimens.

A Study on the Fault Detection of Auto-transmission Using the Vibrational Characteristics of Roller Bearings (롤러 베어링의 진동특성을 이용한 자동변속기 결함 검출에 관한 연구)

  • Park, Ki-Ho;Jung, Sang-Jin;Wee, Hyuk;Lee, Gook-Sun;Cho, Seong-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.3
    • /
    • pp.268-273
    • /
    • 2009
  • The roller bearings play an important role not only sustain radial or axial load of system, but carry out a rotatory movement as a various operating conditions. They happen that incipient faults which were caused by excessive load, manufacturing or assembling process's errors and many other reasons are created. The bearing faults make noise and vibration by a continuous collision of rotatory components, which can lower the quality and stability of auto-transmission. Therefore, it is important to detect the early fault as soon as possible. This paper presents a detecting method for the improvement in quality by developing the program which can be used to analyze and predict the vibrational characteristics caused by roller bearing faults. We completed development of the inspection system of vibration by applying the most efficient detecting methods and verified the system's reliability through experiments.

A Study on the Fault Detection of Roller Bearings in the Auto-Transmission (자동변속기에서의 롤러 베어링 결함 검출에 관한 연구)

  • Park, Ki-Ho;Jung, Sang-Jin;Wee, Hyuk;Lee, Gook-Sun;Cho, Seong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.84-88
    • /
    • 2008
  • The roller bearings play an important role not only sustain radial or axial load of system, but carry out a rotatory movement as a various operating conditions. They happen that incipient faults which were caused by excessive load, manufacturing or assembling process's errors and many other reasons are created. The bearing faults make noise and vibration by a continuous collision of rotatory components, which can lower the quality and stability of auto-transmission. Therefore, it is important to detect the early fault as soon as possible. This paper presents a detecting method for the improvement in quality by developing the program which can be used to analyze and predict the vibrational characteristics caused by roller bearing faults. We completed development of the inspection system of vibration by appling the most efficient detecting methods and verified the system's reliability through experiments.

  • PDF

Combination Therapy of Prednisolone and Toceranib Phosphate in a Dog with Malignant Metastatic Insulinoma

  • Kang, Yeo-Lim;Park, Hee-Myung;Kang, Min-Hee
    • Journal of Veterinary Clinics
    • /
    • v.35 no.5
    • /
    • pp.211-214
    • /
    • 2018
  • A 14-year-old intact female Yorkshire terrier was presented with a 2-month history of shivering, intermittent pelvic limb weakness and collapse. Biochemical abnormalities revealed inappropriately increased serum insulin concentration with persistent hypoglycemia. Abdominal ultrasound revealed multiple various sized nodules in liver and fine-needle aspirates of the nodule showed typical neuroendocrine cells with high cellularity. Computed tomography (CT) revealed well-defined hyperattenuating mass in the right pancreatic lobe with homogenous enhancement. CT findings were consistent with a pancreatic tumor with malignant metastasis. Treatment was initiated with low-dose prednisolone and toceranib phosphate. The dog was maintained stable with no more progression of clinical signs and it is worth to try toceranib phosphate in a dog with metastatic insulinoma for improving the quality of life.

EXPERIMENTAL STUDY ON LASER AND HOT AIR REFLOW SOLDERING OF

  • Tian, Yanhong;Wang, Chunqing
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.469-474
    • /
    • 2002
  • Laser and hot air reflow soldering of PBGA solder ball was investigated. Experimental results showed that surface quality and shear strength of solder bumps reflowed by laser was superior than the solder bumps reflowed by hot air, and the microstructure inside the solder bumps reflowed by laser was much finer. Analysis on interfacial reaction showed that eutectic solder reacted with Au/Ni/Cu pad shortly after the solder was melted. Interface of solder bump reflowed by laser consists of a continuous AuSn$_4$ layer and remnant Au element. Needle-like AuSn$_4$ grew sidewise from interface, and then spread out to the entire interface region. A thin layer of Ni$_3$Sn$_4$ intermetallic compound was found at the interface of solder bump reflowed by hot air, AuSn$_4$ particles distributed inside the whole solder bump randomly. It is the combination effect of the continuous AuSn$_4$ layer and finer eutectic microstructure inside the solder bump reflowed by laser that resulted in higher shear strength.

  • PDF

Needle Thoracoscopic Sympathectomy for Essential Hyperhidrosis (2 mm 흉강내시경을 이용한 흉부교감신경 절제술)

  • 이두연;윤용한;홍윤주;문동석
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.598-603
    • /
    • 1998
  • Excessive sweating of the palms, axillae, and face has a strong negative impact on the quality of life for many people. The existing non-operative therapeutic options seldom give sufficient relief and have a transient effect. But a definitive cure can be obtained by upper thoracic sympathectomy. From June 1997 to October 1997, 117 cases of the needle (2 mm) thoracoscopic thoracic sympathectomies were performed in the Department of Thoracic and Cardiovascular Surgery in the Respiratory Center Yong-dong Severance Hospital in Seoul, Korea. We have followed up on 94 cases which include palmar hyperhidrosis (n=85), facial hyperhidrosis(n=5) and axillary hyperhidrosis(n=4). There were 42 males and 52 females whose ages ranged from 14 to 63 years(median:23 years). The T2 ganglia and T3-4 ganglia were excised by electrocuting with a hook and endoscissors and were removed for histologic examination. There have been no mortalities or life-threatening complications. The surgical results were classified as excellent(much improvement,very dry) in 93.6%, good(some improvement, minimally wet) in 2.1%, and fair(slight improvement, still wet) in 4.2%. Five patients(5.3%) required closed thoracostomy drainage because of pneumothorax in the immediate postoperative day. Horner's syndrome occurred in one case. The compensatory sweating occurred in 67 cases(71.2%) and was embarrassing in 21 cases(22.3%) and disabling in 9 cases(9.6%) of these cases. Primary failure occurred in one case. The patient with primary failure underwent successful operation. Fifty-one patients had concomitant hyperhidrosis. Our experiences indicate needle thoracoscopic sympathectomy is a very effective, safe, and time- saving procedure for essential hyperhidrosis.

  • PDF

Changes in the Quality of Beef Jerky Containing Additional Pine Needle or Mugwort Juice during Storage (솔잎즙 및 쑥즙을 첨가한 우육포의 저장 중 품질변화)

  • Jung, In-Chul;Park, Hyun-Suk;Lee, Kyung-Soo;Moon, Yoon-Hee
    • Journal of Life Science
    • /
    • v.18 no.1
    • /
    • pp.63-68
    • /
    • 2008
  • This study was carried out to investigate the effect of the addition of pine needle juice and mugwort juice on the color, hardness, pH, VBN content, TBARS value and total plate count of beef jerky during storage at room temperature for 60 days. Beef jerky was prepared by three types such as beef jerky containing 50 ml water (control), beef jerky containing 50 ml pine needle juice (PBJ) and beef jerky containing 50 ml mugwort juice (MBJ). The L (lightness) value of the control and PBJ was not significantly changed during storage, but the $L^*$ value of MBJ tended to increase during storage (p<0.05). The $a^*$ (redness) value had the highest at the 60 day storage, and the $a^*$ value of PBJ and MBJ were higher than that of the control (p<0.05). The $b^*$ (yellowness) had the highest at the 60 day storage (p<0.05), and the $b^*$ value was not significantly different among samples. The addition of pine needle juice and mugwort juice had no effect on the changes of color of beef jerky. The hardness tended to increase during storage period, the hardness of the control was higher than those of PBJ and MBJ until storage for 30 days (p<0.05). The pH of samples tended to decrease during storage period (p<0.05). The VBN content of samples tended to increase during storage period, and the VBN content of the control was higher than those PBJ and MBJ on the storage of 60 days (p<0.05). The TBARS value of samples tended to decrease during storage period, and the TBARS value of MBJ had the lowest during storage period (p<0.05). The total plate count tended to decrease during storage period (p<0.05), and the total plate count of control, PBJ and MBJ were 4.93, 4.11 and 4.17 log CFU/g, respectively.

Quality Characteristics of Emulsion-Type Sausage Containing Pine Needle, Perilla Leaves and Green Tea Powder (솔잎, 깻잎 및 녹차분말이 함유된 유화형 소시지 품질특성)

  • Kim, I.K.;Jin, S.K.;Hah, K.H.;Lyou, H.J.;Park, K.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.667-678
    • /
    • 2005
  • This study was carried out to investigate the effects of addition of functional material(T1; pine needle powder, 0.4%, T2; perilla leaves powder, 0.4%, T3; green tea powder, 0.4%) on the quality characteristics of emulsion-type sausages. The samples were stored at $9{\pm}1^{\circ}C$ for 40 days and analyzed with an interval of 10 days. The pH of all emulsion-type sausages increased as storage period increased. Water holding capacity(WHC) of all treatments were slightly increased as storage period increased and rapidly decreased on 40 days of storage. In texture analysis, hardness, chewiness, gumminess and brittleness were increased with storage in all treatments group. TBARS values of T3 was lower than those of other treatments at 1 days of storage, while that was the slightly higher in T4 at 40 day of storage. The L* values was decreased as storage period increased. The a* values was highest in C, while it was the lowest in T2 and T3. The residual nitrite content of all samples were in very safe range during the whole storage period. During the storage period 40 days, the Lactobacilli spp. of C were higher($10^7$CFU/g) than those of 3 treatments. In sensory evaluation, the score of overall acceptability were higher in the order of C(5.5-6.5)>T1(4.8-6.0)>T2(4.8-5.8)>T3(4.3-4.8). In the manufacture of functional sausage containing pine needle, perilla leaves and green tea powder, further studied are needs on addition type/ratio of functional materials and the use of added spices.

Effects of Phytoncide Treatment on the Physicochemical, Microbiological, and Sensory Characteristics of Fresh-cut Lettuce (Phytoncide 처리가 신선편이 양상추의 저장 중 이화학적, 미생물학적 및 관능적 특성에 미치는 영향)

  • Kim, Do-Hee;Kim, Han-Bit;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.20 no.2
    • /
    • pp.166-172
    • /
    • 2013
  • The effect of phytoncide solution treatment on the browning and quality of fresh-cut iceberg lettuce during storage was studied. The treatments were applied as four solutions adjusted at $10^{\circ}C$: distilled water (DW) as the control; edible ethanol (EE); 1% (v/v) phytoncide essential oil from pine needle diluted with distilled water (DP); and 1% (v/v) phytoncide essential oil diluted with edible ethanol (EP). Fresh-cut lettuce was dipped in each solution for 60 sec, was rinsed with distilled water, was packaged with an OPP film bag, and was then stored at $4^{\circ}C$ for 12 days. The EP group had a significantly high level of total soluble solids, titratable acidity, and carbon dioxide, and low total bacteria counts, pH, and oxygen. The sensory score of color in the EP group recorded a high value, but the EE and EP groups recorded low scores in aroma and taste during the storage period. Alcohol and phytoncide were vaporized by opening the package for two hours, and the score of the aroma and taste of EP showed no differences from those of the other groups. Based on the above results, it was determined that the phytoncide essential oil diluted in edible alcohol with 1% solution inhibited the browning of and microbial growth in fresh-cut lettuce, and will be a useful natural compound in maintaining the quality of fresh-cut produce.

Use of Sprinkler System for Production Forest Management of Pine Mushroom (Tricholoma matsutake) (살수장치(撒水裝置)를 이용(利用)한 송이산 관리(管理)에 관(關)한 연구(硏究))

  • Chung, Sang Bae;Kim, Chul Su
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.1 s.158
    • /
    • pp.21-25
    • /
    • 2005
  • In order to prevent the pine mushrooms, Tricholoma matsutake, from being damaged by the pine needle gall midges, Thecodiplosis japonensis, and thereby, to increase their production and improve their quality, a sprinkler system was installed on the mushroom field. A low-concentration insecticide (deltamethrin 1% EC, x2,000) was sprayed once at insects' most active time every day during the period of insects' adult occurrence and thereafter, the irrigation by ground water spraying was periodically enforced. Such a test was conducted at Yangyang-Gun, Kwangwon-do, Korea for 2 years from 2000 through 2001. The pine needle gall midges generally emerged for about 40 days from late May to early July. 50% emergence of them was about June 6, and peak emergence (more than 80%) was early or mid-June. Gall formation rate was 3.5% on average with this ground insecticide spraying, while 51.3% when not treated. Control effectiveness of this insecticide spraying was 92.3%, which was higher than 82.5% by the conventional injection of insecticide into tree stems. Pine mushrooms emerged for about 35 days from mid-September through earlier October, and around 80% of them did for about 15 days from late September through early October. As a result of the periodic ground water-spraying (30 mm per week) for 2 months (from August to October), the production of mushrooms increased by 74.3% (110% in terms of weight), with their quality improvement. The mushrooms produced from the treated stand by the spraying system were priced 8,670,000 wons per hectare, and thus, the net income deducting the facility and management cost was 4,310,000 wons, about 5% higher than value from the control stand. It was analyzed that this treatment was significantly cost effective when the facilities are used more than 5 years.