• Title/Summary/Keyword: Quality of insertion

Search Result 243, Processing Time 0.027 seconds

An Efficient Anisotropic Volume Rendering using an Intensity Interpolation and Adaptive Intermediate Voxel Insertion Method (광도 보간과 적응형 중간복셀 삽입법을 이용한 효율적인 비균등 볼륨 렌더링)

  • 김태영;신병석
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.30 no.11
    • /
    • pp.655-662
    • /
    • 2003
  • In some volume visualization fields such as medical imaging, anisotropic volume data are more common than isotropic ones. In this paper, we propose an efficient rendering method for anisotropic volume data, which directly computes the intensity of intermediate samples by interpolating the intensity of two corresponding voxels on consecutive slices. Unlike density interpolation method, it does not require a preprocessing step for generating intermediate slices or additional memory for storing them. Additionally, we propose an adaptive intermediate voxel insertion method that avoids overblurring on object surfaces. This may occur when we render high frequency areas using the intensity interpolation method. Using these methods, we can improve the rendering speed without sacrificing image quality.

Hole Identification Method Based on Template Matching for the Ear-Pins Insertion Automation System (이어핀 삽입 자동화 시스템을 위한 템플릿 매칭 기반 삽입 위치 판별 방법)

  • Baek, Jonghwan;Lee, Jaeyoul;Jung, Myungsoo;Jang, Minwoo;Shin, Dongho;Seo, Kapho;Hong, Sungho
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.1
    • /
    • pp.7-14
    • /
    • 2021
  • In jewelry industry, the proportion of labor costs is high. Also, the production time and quality of products are highly varied depending on the workers' capabilities. Therefore, there is a demand from the jewelry industry for automation. The ear pin insertion automation system is the robot automatically inserts the ear pins into the silicone mold, and this automated system require accurate and fast hole detection method. In this paper, we propose optimal binarization method and a template matching method that can be applied in the ear pin insertion automation system. Through the performance test, it was shown that the applied method has an accuracy of 98.5% and 0.5 seconds faster processing speed than the Otsu binarization method. So, this automation system can contribute to cost reduction, work time reduction, and productivity improvement.

A Study on complex waterproofing Method Using Part of Joint Watertightness Improved Sheet (접합부 수밀성 향상 시트를 이용한 복합방수 공법에 관한 연구)

  • Suh Woo-Il;Kim Su-Ryon;Kwak Kyu-Sung;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.1-6
    • /
    • 2004
  • We ensure a flat and regular basic surface by using part of joint waterproofing improved sheet method applying the upper slab of a concrete structure. We solve the problem of getting loose scale the general sheet by waterproofing of the sheet and improving adhesive strength of the basic concrete. Also, waterproofing sheet union to problem of joint have solved using of insertion type method so that, it improved a watertightness. It has improved in resist impact, resist abrasion and it is the effect of shortened construction period and cutting down on construction expenses. Here are the special quality and superiority of this waterproofing research. (1) Level material has the super adhesive strength so that it makes the basic surface without the gab of waterproofing sheet and waterproofing layer with the string adhesive strength. (2) We unite the sheet with the joining part between sheets by waterproofing sheet joint using of method. (3) There is the effect of shortened construction period and cutting down on construction expenses without waterproofing of protection.

  • PDF

Early experiences with robot-assisted prosthetic breast reconstruction

  • Ahn, Sung Jae;Song, Seung Yong;Park, Hyung Seok;Park, Se Ho;Lew, Dae Hyun;Roh, Tai Suk;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.46 no.1
    • /
    • pp.79-83
    • /
    • 2019
  • Robotic surgery facilitates surgical procedures by employing flexible arms with multiple degrees of freedom and providing high-quality 3-dimensional imaging. Robot-assisted nipple-sparing mastectomy with immediate reconstruction is currently performed to avoid breast scars. Four patients with invasive ductal carcinoma underwent robot-assisted nipple-sparing mastectomy and immediate robot-assisted expander insertion. Through a 6-cm incision along the anterior axillary line, sentinel lymph node biopsy and nipple-sparing mastectomy were performed by oncologic surgeons. The pectoralis major muscle was elevated, an acellular dermal matrix (ADM) sling was created with robotic assistance, and an expander was inserted into the subpectoral, sub-ADM pocket. No patients had major complications such as hematoma, seroma, infection, capsular contracture, or nipple-areolar necrosis. The mean operation time for expander insertion was 1 hour and 20 minutes, and it became shorter with more experience. The first patient completed 2-stage prosthetic reconstruction and was highly satisfied with the unnoticeable scar and symmetric reconstruction. We describe several cases of immediate robot-assisted prosthetic breast reconstruction. This procedure is a feasible surgical option for patients who want to conceal surgical scars.

Superconducting Bandpass Fitter Using Hairpin-type Microstrip Line with Narrow Bandwidth Centered at 14 GHz (14 GHz 헤어핀형 초전도 대역통과 필터)

  • Son, Seok-Cheon;Kim, Cheol-Su;Lee, Sang-Yeol;Yoon, Hyung-Kuk;Yoon, Young-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1852-1854
    • /
    • 1999
  • In order to enhance satellite communication system performance, filters are required with the characteristics of sharp skirt, low insertion loss, and high power handling capability. But the performance of microwave passive filters is significantly declined by the conduction losses, especially in case of planar structures using film conductors. By using high temperature superconducting(HTS) film material as the conductor, higher performance could be expected. We have designed and developed narrow bandpass filters using haripin-type superconducting microstrip line for satellite communication. High quality superconducting YBCO thin films have been grown on MgO substrates by pulsed laser deposition(PLD) The deposited YBCO films were patterned by conventional wet-etching process. The transition temperatures of these films had shown 86 - 89 K. The film thicknesses were about 500 nm. Experimental results are presented for the insertion loss and return loss of the filter at 60 K.

  • PDF

Clinical Evaluation of a Low-pain Long Microneedle for Subcutaneous Insulin Injection

  • Lee, Ghunil;Ma, Yonghao;Lee, Yong-ho;Jung, Hyungil
    • BioChip Journal
    • /
    • v.12 no.4
    • /
    • pp.309-316
    • /
    • 2018
  • Microneedles (MNs) are being developed to overcome the limitations of the conventional hypodermic needle, e.g. the injection pain. In this study, we conducted an analysis of clinical pain and bleeding at the site of MN insertion and evaluated the insulin pharmacodynamic profile compared with parameters obtained with a conventional pen needle. MN insertion into the skin of 25 healthy adults or 15 patients with type 2 diabetes (T2D) revealed significantly less pain relative to a conventional hypodermic pen needle, thus reducing pain scores from $2.1{\pm}1.9$ to $21.3{\pm}1.4$ ($mean{\pm}standard$ deviation [SD]). Besides, no bleeding was observed when the MN was used. In the insulin pharmacodynamic assay, no significant differences were observed in the blood glucose-lowering effect between the pen needle and MN. Based on these results, the MN is expected to be a good substitute for conventional hypodermic pen needles and improve the quality of life of patients by significantly reducing the pain associated with insulin treatment.

Analysis of Inrush Current Reduction Rate According to Insertion Resistance of the Superconducting Fault Current Limiter (초전도 한류기 투입저항 변화에 따른 여자돌입전류 저감률 분석)

  • Park, Se-Ho;Seo, Hun-Chul;Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.257-258
    • /
    • 2008
  • The inrush current of a transformer is a high-magnitude and harmonic-rich current generated when the transformer core is driven into saturation during energizing. The inrush current usually leads to undesirable effects, for example potential damage to the transformer, misoperation of a protective relay, and power quality deterioration in the distribution power system. Inrush current reduction is therefore important for power system operation. In this paper, to reduce the inrush current, the insertion resistance of the Superconducting Fault Current Limiter (SFCL) that is connected in series with the transformer in the distribution system is used. This paper implements the SFCL by using the Electromagnetic Transient Program-Restructured Version (EMTP-RV) to model the SFCL in the distribution system. The simulation results show the beneficial effects of the SFCL for reduction of the inrush current.

  • PDF

Implementation of Motion Picture Processor for Low-cost CSTN-LCD (저가형 CSTN-LCD 동영상 프로세서 설계)

  • Kim, Yong-Bum;Choi, Myung-Ryul
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.8
    • /
    • pp.963-970
    • /
    • 2006
  • In this paper, we proposed a motion picture processor for using low-cost color super twisted nematic liquid crystal display(CSTN-LCD). The proposed processor apply a new driving scheme using SFP(Subgroup Frame Pattern), so we extends gray scale and eliminates flicker phenomenon. In addition, we apply the BFI (Black Field Insertion) to the design compensated for response time of a LC (Liquid Crystal). We use an edge enhancement and interpolation method to improve image quality of motion picture. The hardware architecture of proposed processor has been implemented and verified on a prototype FPGA board. The proposed method can be used in the display devices such as PDA(Personal Digital Assistants), mobile phone, and PMP(Portable Multimedia Player).

  • PDF

Prognostic factors associated with the success rates of posterior orthodontic miniscrew implants: A subgroup meta-analysis

  • Hong, Sung-Bin;Kusnoto, Budi;Kim, Eun-Jeong;BeGole, Ellen A;Hwang, Hyeon-Shik;Lim, Hoi-Jeong
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.111-126
    • /
    • 2016
  • Objective: To systematically review previous studies and to assess, via a subgroup meta-analysis, the combined odds ratio (OR) of prognostic factors affecting the success of miniscrew implants (MIs) inserted into the buccal posterior region. Methods: Three electronic searches that were limited to articles on clinical human studies using MIs that were published in English prior to March 2015 were conducted. The outcome measure was the success of MIs. Patient factors included age, sex, and jaw of insertion (maxilla vs. mandible), while the MI factors included length and diameter. A meta-analysis was performed on 17 individual studies. The quality of each study was assessed for non-randomized studies and quantified using the Newcastle-Ottawa Scale. The meta-analysis outcome was a combined OR. Subgroup and sensitivity analyses based on the study design, study quality, and sample size of miniscrews implanted were performed. Results: Significantly higher success rates were revealed for MIs inserted in the maxilla, for patients ${\geq}20$ years of age, and for long MIs (${\geq}8mm$) and MIs with a large diameter (> 1.4 mm). All subgroups acquired homogeneity, and the combined OR of the prospective studies (OR, 3.67; 95% confidence interval [CI], 2.10-6.44) was significantly higher in the maxilla than that in the retrospective studies (OR, 2.10; 95% CI, 1.60-2.74). Conclusions: When a treatment plan is made, these risk factors, i.e. jaw of insertion, age, MI length, and MI diameter, should be taken into account, while sex is not critical to the success of MIs.

Comparative Biomechanical Study of Self-tapping and Non Self-tapping Tapered Dental Implants in Artificially Simulated Quality 2 Bone

  • Baek, Yeon-Wha;Kim, Duck-Rae;Park, Ju-Hee;Lim, Young-Jun
    • Journal of Korean Dental Science
    • /
    • v.4 no.2
    • /
    • pp.52-58
    • /
    • 2011
  • Purpose: Modifications of implant design have been related to improving initial stability. The purpose of this study was to investigate their respective effect on initial stability between two tapered implant systems (self-tapping vs. non-self-tapping) in medium density bone using three different analytic methods. Materials and Methods: Self-tapping implant (GS III$^{(R)}$; Osstem Implant Co., Busan, Korea) and non-self-tapping implant (Replace Select$^{(R)}$; Nobel Biocare, G$\H{o}$teborg, Sweden) were investigated. In Solid rigid polyurethane blocks of artificially simulated Quality 2 bone, each of the 5 implants was inserted according to the manufacturer's instructions for medium-bone drilling protocol. Evaluation of initial stability was carried out by recording the maximum insertion torque (IT) and performing the resonance frequency analysis (RFA), and the pull-out test. Results: The IT and RFA values of self-tapping implant were significantly higher than those of non self-tapping implant (P=.009 and P=.047, respectively). In the pull-out values, no significant differences were found in implants between two groups (P=.117). Within each implant system, no statistically significant correlation was found among three different outcome variables. Conclusions: These findings suggest that design characteristics of implant geometry significantly influence the initial stability in medium bone density.