• Title/Summary/Keyword: Quality of Medical

Search Result 6,117, Processing Time 0.048 seconds

Antioxidant Activity of Solvent Fractions from Cultivated and Wild Gromwell (재배와 야생 지치의 추출물과 용매별 분획물의 항산화효과)

  • Kim, Jin-Sook;Kang, Myung-Hwa
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.6
    • /
    • pp.789-795
    • /
    • 2010
  • In order to set up an accurate quality criteria for the Boraginaceae that have been traditionally used for medical purposes and food colorant, and to assess its viability as functional food ingredient, antioxidant tests were conducted on the wild and cultivated plants. Variety of indicators including total contents of phenol, DPPH, SOD-liked effect, hydroxy radical-scavenging effect, lecithin oxidation inhibitory effect, etc were analyzed. Wild and cultivated gromwell's total contents of phenol in their methanol extracts were 0.14% and 0.13%, while they were most active in ethyl acetate extracts and n-hexane extracts, respectively. $IC_{50}$ values of methanol extract of the wild and cultivated plants were 794.41 ${\mu}g$/mL and 971.86 ${\mu}g$/mL, indicating that the wild plant is more responsive (p<0.05) to low concentration. Also the wild and cultivated plants were most active in ethyl acetate fraction and n-hexane extracts when their $IC_{50}$ values were measured by each solvent extracts. SOD-liked effects of both plants were concentration dependent while methanol extracts were more active (p<0.05) in 500 ${\mu}g$/mL than other solvent extracts. Hydroxy radical-scavenging effect of both plants showed less than 50% activity in concentration of 1,000 ${\mu}g$/mL except in chloroform fraction and n-hexane fraction. Lecithin oxidation inhibitory effects of the wild and cultivated plants were active in methanol and solvent extracts of 200~1000 ${\mu}g$/mL. Especially it showed 90% of high inhibitory effect in 1,000 ${\mu}g$/mL of chloroform fraction. Hence, both wild and cultivated Boraginaceae were analyzed to be viable as functional food ingredient.

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

A Study on Projection Angles for an Optimal Image of PNS Water's View on Children (유.소아 부비강 Water's 영상의 이상적 구현을 위한 촬영기준각도 변화에 관한 연구)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Sung-Kyu;Hong, Sang-Woo;Kim, Je-Bong
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • This study is to calculate the proper angle for the optimal image of PNS Water's view on children, comparing and analyzing the PNS Water's projection angles between children and adults at every age. This study randomly selected 50 patients who visited the Medical Center from January to May in 2005, and examined the incidence path of central ray, taking a PNS Water's and skull trans-Lat. view in Water's filming position while attaching a lead ball mark on the Orbit, EAM, and acanthion of the patients's skull. And then, we calculated the incidence angles(Angle A) of the line connected from OML and the petrous ridge to the inferior margin of maxilla on general(random) patients's skull image, following the incidence path of central ray. Finally, we analyzed two pieces of the graphs at ages, developing out the patients' ideal images at PNS Water's filming position taken by a digital camera, and calculating the angle(Angle B) between OML and IP(Image Plate). The angle between OML and IP is about $43^{\circ} in 4-years-old children, which is higher than $37^{\circ}, as age increases the angle decreases, it goes to $37^{\circ} around 30 years of age. That is similar result to maxillary growth period. We can get better quality of Water's image for children when taking the PNS Water's view if we change the projection angles, considering maxillary growth for patients in every age stage.

  • PDF

Effects of Leisure Time-Use and Occupational Performance according to the Participation of a Rehabilitation Sports Program for Intellectual Disabilities Residing in a Residential Care Facility (시설 거주 지적장애인들의 재활체육 프로그램 참여에 따른 여가시간 사용과 여가활동 수행에 미치는 영향)

  • Son, Sung-Min;Lee, Kyeong-Lark;Jeon, Byoung-Jin
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.6 no.2
    • /
    • pp.51-59
    • /
    • 2016
  • Objective : The purpose of study is to provide basic information about the effects of leisure time use and leisure activity performance for intellectual disabilities residing in a residential care facility by participating a regular rehabilitation sports program. Methods : Participants were recruited 8 individual with intellectual disability in a residential care facility in Yong-in city and the study period lasted 12 weeks, from september 1 to November 30 in 2015. As a program, participants participated a muscle strengthening exercise using a Gym-ball and a elastic band. In order to analyze leisure time-use, time questionnaire was used every month to analyze total time and exercise frequency. Also, analyze the effects of leisure activity performance, Canadian Occupational Performance Measure(COPM) was used to performance and satisfaction of dynamic leisure activity. Collected data was encoded by item and analyzed with SPSS ver18.0. Descriptive statistics were used for the participants' general information. A non-parametric test (the Friedman test) was used to analyze leisure time-use. A non-parametric test (the Wilcoxon's signed ranked test) was used to analyze to the effects of leisure activity performance. Statistical significance was accepted outside the 95% confidence interval. Results : The results of the total time and the exercise frequency showed significant increase. Also, the results of the performance and the satisfaction showed significant increase. Conclusion : Thus, the participation of the rehabilitation sports program is a vital element to lead to change leisure time use and leisure activity performance for intellectual disabilities residing in a residential care facility. Also, through the providing and the developing a regular rehabilitation sports program systematically, intellectual disabilities residing in a residential care facility have a higher quality of life and satisfaction of the daily routine and life in a residential care facility.

Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS) (선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰)

  • Yoon, Joon;Lee, Gui-Won;Park, Byung-Moon
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • In this paper we evaluated small field dose characteristics of exclusive cone fields versus square fields for stereotactic radiosugery (SRS) which is based on linear accelerators (LINAC). For this test, we used a small beam detector (stereotactic fields detector : SFD) with a 6 MV photon beam and a water phantom system (IBA, Germany). Percentage depth dose (PDD) was measured for different field sets (cones : ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$ ; square fields : $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$) at a source skin distance (SSD) of 100 cm. We measured the point depths at 1.5 cm, 5 cm, 10 cm, 20 cm, and 30 cm. The output factors were measured under the same geometrical conditions of the PDD and normalized at the maximum dose depth. To analyze the penumbra, we measured the dose profile with 95 cm of SSD, 5 cm of depth for each field sizes (${\Phi}1\;cm$, ${\Phi}3\;cm$, $1{\times}1\;cm^2$, and $3{\times}3\;cm^2$) using SFD. We obtained the values for every 1 mm interval in the physical field (90%) and 0.5 mm interval in the penumbra region (20 to 80%). The PDD variation of exclusive cones and square fields were 4.3 to 7.9% lesser than the standard field size ($10{\times}10\;cm^2$. The variation of PDD was reduced while the field size was increased. To compare the beam quality, we analyzed the $PDD_{20,10}$ and the results showed under the 1% of variations for all experiments except for ${\Phi}1\;cm$ cone and $1{\times}1\;cm^2$ fields. Output factors of exclusive cone were increased 3.1~4.6% than the square fields, and the penumbra region of exclusive cone was reduced 20% as compared to the square fields. As the previous researches report, it is very important for SRS and SFD that precise dosimetry in small beam fields. In this paper, we showed the effectiveness of exclusive cone, compared to square field. And we will study on the various detector characteristics for small beam fields.

Strategies for Public Health Service Development in the Times of Local Autonomy (지방자치시대의 공공보건사업 발전 전략)

  • 박정한
    • Health Policy and Management
    • /
    • v.12 no.3
    • /
    • pp.1-22
    • /
    • 2002
  • Health is a fundamental human right and a sine qua non for happiness of people and for national development. Government has a responsibility for the provision of health services for their people. Recent changes of disease pattern, i.e. decrease of Infectious diseases and increase of chronic and degenerative diseases Including cancer and cardiovascular diseases, together with universal coverage of health insurance and improved living standard have prompted medical care utilization and skyrocketed the national health expenses. The goal of national health policy is improving the quality of life through the betterment of health level. To achieve this goal it is necessary to establish a healthcare system for lifetime, to improve the efficiency of healthcare delivery system, and to strengthen the public health services for disease prevention and health promotion. The current public health service programs are Inefficient due to an inconsistent policy for health service program, lack of health information system, irrational health program planning and evaluation, and Inadequate training of health workers. Local government has a legal responsibility for health service program planning and promoting the competence of health workers. Thus, municipal and provincial health departments should expand their roles and strengthen their function. The strategies for developing public health service programs at local level are ${\circled}1$ stipulating the goals of health policy, ${\circled}2$ promoting the ability for health program planning and evaluation, ${\circled}3$ establishing health information and surveillance system, ${\circled}4$ training of health workers, ${\circled}5$ establishing an institution for health information management and training of health workers, and ${\circled}61$ collaboration with local universities.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

A Study on the Guardian's Perception of Attending Patient in Pediatric Radiography (소아 방사선 검사 시 보호자 참여에 대한 인식도 조사)

  • Kwak, JongHyeok;Jeong, JaeBeom
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.189-201
    • /
    • 2014
  • The purpose of this study was to survey guardian's opinion on assisting pediatric radiography and their level of awareness of radiation, improving the quality of pediatric radiography. In this study, the recognition was analyzed for 210 parents of child patients in Pusan National University Hospital from August 20 to September 15, 2013. A total of 66.2 percent of the respondents said they had participated in pediatric radiography in the past. The reason why they did is "Radiologist's request", the highest. According to the survey, 84.3 percent said they thought it is necessary to attending patient in pediatric radiography. "The stability of the child" is the reason for it. And respondents who thought there's no need to do that answered back, the reason for this is "Radiologist's work." There was a significant difference on the psychological state for the medical radiation by gender and child age. (p<0.05) In the analysis of recognition for the radiation, there was the significance by gender and education. (p<0.05) Regarding the awareness of the radiation protector, there was a statistical significance in age, gender, child age and education. (p<0.05) Considering the results, pediatric patient's guardians recognized that it is necessary to attend a child on X-ray for their child's stability and accurate exam above all. It must make guardians wear X-ray protector and radiologist should let the guardians recognize the X-ray examination method, before starting pediatric x-ray. It needs to improve the atmosphere of the examination room and to be considered to take visual and auditory approaches in comfort for reducing the children's fear and anxiety.

Effect of Gill, Drying and Temperature and Chitosan-Ascorbate Treatment on Growth of Contaminated Microorganism in Flounder during Storage (참가자미의 저장 중 오염미생물의 생육에 미치는 아가미의 유무, 건조도, 저장온도 및 키토산-아스코베이트의 처리효과)

  • Kim, Young-Sook
    • KSBB Journal
    • /
    • v.23 no.5
    • /
    • pp.375-380
    • /
    • 2008
  • We made an experiment of keeping extension of raw and semi-dried flounder (Pleuronectes herzensteini). Effect of with(WG) or without gill (OG), drying degree (20% drying:20D, 40% drying:40D) and storage temperature (5 and $10^{\circ}C$) and 0.1% chitosan-ascorbate (CA) treatment of vacuum packaging flounder on growth of contaminated microorganism during storage for 10 days were investigated. Total aerobacter (TA) in the OG-treated raw flounder was $0.3{\sim}0.5$ log cycle lower than that of WG-treated flounder and also, number of coliform (CF) and E. coli (CO) in OG were lower compared with WG. Number of TA,. Especially, the TA was $0.42{\sim}1.20$ log cycle lower compared with raw flounder. The TA of the raw flounder stored at $5^{\circ}C$ compared to $10^{\circ}C$ was $0.6{\sim}1.3$ log cycle lower. The growth of total aerobacter, coliform (and E. coli separated from raw flounder in tryptic soy broth were completely inhibited by 0.1% CA. But the growth of TA in the raw and 20% dried flounder was 1.5 log cycle inhibited by 0.1% CA, and the growth of CF and CO were also slightly inhibited. We did value raw sample that treated CA 0D and 20D, and did vaccum packaging at the $10^{\circ}C$ for 10 days, Sensory quality such as appearance, freshness, and texture and overall acceptability after cooking of the 0.1% CA-treated raw and 20% dried flounder were evaluated from good to very good, while CA non-treated products were evaluated to moderate.

Comparative Chemical Compositions of Four Kinds of Tochukaso (동충하초 품종별 영양성분 비교)

  • Oh, Se-Wook;Kim, Sun-Hee;Song, Hyo-Nam;Han, Dae-Seok
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.15-22
    • /
    • 2003
  • Nutritional compositions of three Tochukaso species (Paecilomyces tenuipes hosted by Larva and pupa, Cordyceps militaris, C. sinensis) were compared. Fruiting body and host fractions were separately analyzed. Fruiting body fraction of P. tenuipes (36.6%) hosted by larva was higher than that hosted by pupa (10.2%), an indication that the quality of the former is superior to the latter. Carbohydrate content of C. sinensis (39.6%) was $2.5{\sim}7$ times higher than those of others, probably due to the presence of polysaccharides. Protein and crude lipid contents of C. sinensis and C. militaris were 25.8 and 10.3%, and 75.1 and 3.9%, respectively. C. sinensis showed the lowest Ca content and $30{\sim}75$ times higher Fe content among the samples tested. Vitamin A content of C. militaris was 308.9 IU/100g, two fold higher than those of the other species. Saturated fatty acid content was the highest in P. tenuipes (pupa, 27.7%), whereas unsaturated fatty acid was the highest in P. tenuipes (larva, 83.3%). Aspartic acid, glutamic acid, and glycine were abundant in all species. Cordycepin content of C. militaris was $20{\sim}50$ times higher than those of the other species.