• 제목/요약/키워드: Quality indicator

검색결과 948건 처리시간 0.031초

산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화 (Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator)

  • 김만구;권영진;정영림
    • 한국대기환경학회지
    • /
    • 제13권2호
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF

인증시설 보육교사의 의사결정참여도에 따른 평가인증지표의 유지도 (The Maintenance of An Evaluation Accreditation Indicator According to Teachers' Participation in Decision Making)

  • 부수안;이소은
    • 아동학회지
    • /
    • 제31권1호
    • /
    • pp.163-177
    • /
    • 2010
  • The purpose of this study was to examine the maintenance of an evaluation accreditation indicator according to child care center teachers' participation in decision making. The subjects of this study were 139 teachers from 12 accredited national, public, private, and corporate child care centers in Seoul and North Gyeongsang Province. The TIP-2 (Teacher Involvement and Participation Scale V.2) and Accreditation Indicator for Child Care Centers were used to measure teachers' participation in decision making and accreditation indicator maintenance. Frequency, mean, standard deviation, one-way ANOVA and scheffe test were used for data analyses. The results revealed that the teachers who rated middle and high level in terms of their participation in decision-making showed higher levels of maintenance of the evaluation accreditation indicator than those with low levels of participation. This finding suggests that teachers' participation in decision making is an important factor for maintaining the quality of child care centers.

한국아동보육사업의 경제적 규모 평가를 위한 지표개발 연구 (Development of Indicators for Evaluating the Size of Economic Investment for Child Care in Korea)

  • 이승희;백일우;김명순
    • 아동학회지
    • /
    • 제26권1호
    • /
    • pp.183-202
    • /
    • 2005
  • This study performed intensive indicators based on a model of economics of education. Trends of childcare in Korea were obtained by producing values developed with statistical data. Results showed that such simple initial indicator values as numbers of children, institutions and teachers have improved. However, intensive indicator values that take demographic and economic conditions into consideration have not reached the same rate of progress as the initial indicator values. In other words, qualitative growth remains at an unsatisfactory level in comparison to quantitative growth and to qualitative growth in members of the Organization for Economics Cooperation and Development (OECD).Thus, financial investment by the government should be expanded in order to reach the desired level of high quality in daycare for children.

  • PDF

스마트시티 IoT 품질 지표 개발 및 우선순위 도출 (Development of Smart City IoT Data Quality Indicators and Prioritization Focusing on Structured Sensing Data)

  • 양현모;한규보;이정훈
    • 한국빅데이터학회지
    • /
    • 제6권1호
    • /
    • pp.161-178
    • /
    • 2021
  • '빅데이터'는 '21세기 원유'로 비유될 만큼 그 중요성이 증대되고 있다. 스마트시티에서 생성 및 수집되는 IoT 데이터의 경우 데이터의 품질이 공공서비스의 품질과 연관되므로 품질관리에 주의를 기울여야 한다. 그러나 ISO/IEC 기관 및 국내/외 여러 기관을 통해 제시된 데이터 품질 지표는 '사용자' 중심에 한정되어 있다는 한계점을 지닌다. 본 연구는 이러한 한계점을 보완하기 위해 공급자 중심의 지표와 그 우선순위를 도출하였다. 공급자 중심의 스마트시티 IoT 데이터 품질 평가지표 3개의 카테고리와 13개의 지표를 도출한 후 AHP 분석을 통하여 지표 카테고리와 데이터 품질 지표의 우선순위를 도출하였고 각 지표의 타당성을 조사하였다. 해당 연구를 통해 센서 데이터를 수집하고 취합하여 전달하는 직무를 수행하는 개인 혹은 기업에게 데이터가 지녀야 하는 기본적인 요건을 제시함으로써 센서 데이터 품질 향상에 기여할 수 있다. 또한 지표 우선순위를 기반으로 데이터 품질관리를 수행하여 품질관리 업무 효율의 향상을 제공할 수 있다.

수질오염총량관리를 위한 대상물질 적용성 분석 (Applicability of Water Quality Indicators as Target Pollutants for Total Maximum Daily Loads)

  • 박준대;오승영;박재홍
    • 한국물환경학회지
    • /
    • 제29권4호
    • /
    • pp.531-539
    • /
    • 2013
  • In order to apply a water quality indicator as a certain target pollutant, the indicator should have the representability of an index for the management of Total Maximum Daily Loads (TMDLs). Scientific groundwork and treatment technologies also should be provided for the application of the indicator. This study analyzed the applicability of major water quality indicators for target pollutants. The results showed that four water quality indicators of TOC, T-N, SS & T-Coli can be considered as target pollutants besides existing BOD and T-P. These indicators can be applied with the preparations such as essential basic data, pollution load estimation framework as well as legal criteria setting when the need is raised. As the importance of TOC, which is considered as a replacement of BOD, is emphasized, technical and institutional terms are being prepared in order to determine TOC as another target pollutant in the near future. It could be considered to combine TOC with BOD for the time being during the $3^{rd}$ stage of TMDLs in view of the present conditions for the management of TOC. TOC can be the most effective index for the organic matter and help to be managed more systematically in the waterbodies where rivers and lakes are mutually connected.

Computed Radiograhpy (CR)를 통한 목재 수종별 X선 투과 이미지 해석을 위한 기초연구 (1) (Preliminary Study (1) for Development of Computed Radiography (CR) Image Analysis according to X-ray Non-destructive Test by Wood Species)

  • 송정일;김한슬
    • 보존과학회지
    • /
    • 제37권3호
    • /
    • pp.220-231
    • /
    • 2021
  • 문화재 방사선 비파괴 투과 조사 방식은 이미지플레이트(Image Plate, IP)를 사용하는 디지털 방사선영상시스템(Computed Radiography, CR)이 도입되면서 필름방식의 아날로그 이미지에서 점차 디지털 이미지로 교체되고 있다. 방사선 비파괴 투과 조사의 이미지 품질은 촬영 조건(관전압, 관전류, 노출시간), 영상 획득 매체, 촬영 거리, 유물의 두께 등이 영향을 미친다. 이 논문에서는 목재 문화재에 주로 사용되는 수종(소나무, 밤나무, 은행나무, 상수리나무)에 X선 선원의 투과 특성을 GE사(社)의 CR 영상 시스템을 통해 획득된 이미지의 그레이 스케일(Gray Scale)을 분석한 후 신호 대 잡음비(signal to noise ratio) 및 대조도를 평가하고, 이중-선 상질계(Duplex-wire image quality indicator), 구형파 차트(line-pair gauges), 선형 식별계(Image Quality Indicator)를 이용하여 이미지를 분석하였다.

Improved Adaptive Smoothing Filter for Indoor Localization Using RSSI

  • Kim, Jung-Ha;Seong, Ju-Hyeon;Ha, Yun-Su;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.179-186
    • /
    • 2015
  • In the indoor location estimation system, which has recently been actively studied, the received signal strength indicator contains a high level of noise when measuring the signal strength in the range between two nodes consisting of a receiver and a transceiver. To minimize the noise level, this paper proposes an improved adaptive smoothing filter that provides different exponential weights to the current value and previous averaged one of the data that were obtained from the nodes, because the characteristic signal attenuation of the received signal strength indicator generally has a log distribution. The proposed method can effectively decrease the noise level by using a feedback filter that can provide different weights according to the noise level of the obtained data and thus increase the accuracy in the distance and location without an additional filter such as the link quality indicator, which can verify the communication quality state to decrease the range errors in the indoor location recognition using ZigBee based on IEEE 802.15.4. For verifying the performance of the proposed improved adaptive smoothing filter, actual experiments are conducted in three indoor locations of different spatial sections. From the experimental results, it is verified that the proposed technique is superior to other techniques in range measurement.

웹 어플리케이션의 모듈위험수준 측정 도구의 구현 (Implementation of the Module Risk Levels Measurement Tools for Web Application)

  • 김지현;박철
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권2호
    • /
    • pp.87-94
    • /
    • 2002
  • 웹 어플리케이션의 작성에 많이 사용되는 ASP로 개발된 프로젝트에서 각 모듈의 위험수준을 분석할 수 있는 측정 도구를 개발하고 이 측정 도구를 실무에서 사용 중인 프로젝트에 적용하여 유용성을 보인다. 본 논문에서 개발된 측정 도구는 NASA의 GSFC에서 개발한 소프트웨어 산출물 품질 메트릭인 모듈위험수준 인디케이터(Indicator of the Module Risk Levels)를 사용한 것으로, 웹 어플리케이션의 위험수준을 파악하여 오류 가능성이 있는 위험한 모듈을 조기에 발견함으로서 유지보수성 향상에 기여하고자 한다.

  • PDF