• Title/Summary/Keyword: Quality factor(Q)

Search Result 459, Processing Time 0.03 seconds

High-Q Resonator with Substrate Integrated Waveguide(SIW) Structure (높은 Q 값을 갖는 기판 집적형 도파관(SIW) 공진기)

  • Yun Tae-Soon;Nam Hee;Lee Jong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.324-329
    • /
    • 2006
  • In this paper, a resonator with the substrate integrated waveguide(SIW) structure at the satellite communication band is presented. The SIW structure is realized by via-holes on the dielectric substrate and has an advantage of integration with other circuits. For the measurement, a designed back-to-back transition has the insertion loss of 0.4 dB at 18 GHz. Also, the quality factor of the resonator with the SIW structure including back-to-back transition is obtained to be 222. The high-Q resonator with the SIW structure can be used in filter, oscillator, and voltage controlled oscillator.

Effect of Cobalt Substitution on the Magnetic Properties of NiZnCu Ferrite for Multilayer Chip Inductors (Cobalt 치환된 칩인덕터용 NiZnCu Ferrite의 자기적 특성 연구)

  • An, Sung-Yong;Kim, Ic-Seob;Son, Soo-Hwan;Song, So-Yeon;Hahn, Jin-Woo;Choi, Kang-Ryong
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.5
    • /
    • pp.182-186
    • /
    • 2010
  • Effect of cobalt substitution on the sintering behavior and magnetic properties of a NiZnCu ferrite was studied. $Ni_{0.36-x}Co_xZn_{0.44}Cu_{0.22}Fe_{1.98}O_4(0{\leq}x{\leq}0.04)$ ferrite was fabricated by a solid stat reaction method. It was proposed and experimentally verified that $Co^{2+}$ substituted NiZnCu ferrite was effective on improving the quality factor and magnetic properties of NiZnCu ferrites for multilayer chip inductors. The ferrite was sintered without sintering aids, at $880{\sim}920^{\circ}C$, for 2 h and the initial permeability, quality factor, density, shrinkage, saturation magnetization, and coercivity were also measured. The quality factor (Q) was increased linearly up to x = 0.01 and decreased rapidly over x = 0.01. As the cobalt content increased, the initial permeability and density of the ferrites decreases. The initial permeability of toroidal sample for $Ni_{0.35}Co_{0.01}Zn_{0.44}Cu_{0.22}Fe_{1.98}O_4$ ferrites sintered at $900^{\circ}C$ was 130 at 1 MHz and quality factor was 230.

Electrical properties of $MnO_2$doped PSN-PNN-PT ceramics ($MnO_2$가 첨가된 PSN-PNN-PT세라믹스의 전기적인 특성)

  • 이종덕;박상만;박기엽
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.959-962
    • /
    • 2001
  • In this study, the piezoelectric and dielectric properties and Temperature stability of resonant frequency with MnO$_2$doped 0.36Pb(Sc$_{1}$2/Nb$_{1}$2/)O$_3$- 0.25Pb(Ni$_{1}$3/Nb$_{2}$3/)O$_3$-0.39PbTiO$_3$(hereafter PSNNT) were investigated. The tetagonality of crystal structure was developed with increasing MnO$_2$additive content. With increasing MnO$_2$additive content, the electromechanical coupling factor and quality factor were increased. Electromechanical coupling k$_{p}$ and quality factor Q$_{m}$ at MnO$_2$doped with 2.0mol% were showed highest value of 55.6% and 252. In the case of specimen for MnO$_2$doped with 2mol%, temperature dependance of resonant frequency had a good properties.ies.

  • PDF

Dielectric and Piezoelectric Properties of Low Temperature Sintering PSN-PZI Ceramics with BiFe3 Substitution (BiFe3첨가에 따른 저온소결 PSN-PZT세라믹스의 유전 및 압전 특성)

  • 류주현;정광현;정영호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.492-496
    • /
    • 2004
  • In this study, (0.96 -x)(PSN-PZT)-xBF-0.04 PNW+0.3wt%MnO$_2$+0.6wt%CuO ceramics were fabricated with the variations of the amount of BiFeO$_3$substitution and sintering temperature for the development of modified ceramics which can be sintered in the low temperature($\leq$100$0^{\circ}C$ ), and their microstructural, dielectric and piezoelectric characteristics were investigated. As the amount of BiFeO$_3$ substitution was increased, the density, mechanical quality factor(Q$_{m}$) and electromechanical coupling factor(k$_{p}$) showed the maximum value at each of sintering temperature. At sintering temperature of 98$0^{\circ}C$ and BiFeO$_3$substitution of 2 mol%, the density, dielectric constant and electromechanical coupling factor(k$_{p}$) showed the maximum value of 7.84 g/㎤, 1415 and 0.49, respectively. And at sintering temperature of 95$0^{\circ}C$ and BiFeO$_3$substitution of 3mol%, mechanical quality factor showed the maximum value of 1062. 1062.

Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses (흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.120-125
    • /
    • 2010
  • For the measurements of an absorbed dose using the standard dosimetry based on an absorbed dose to water the variety of factors, whether big, small, or tiny, may influence the accuracy of dosimetry. The beam quality correction factor ${\kappa}_{Q,Q_0}$ of an ionization chamber might also be one of them. The cylindrical type of ionization chamber, the PTW30013 chamber, was chosen for this work and 9 chambers of the same type were collected from several institutes where the chamber types are used for the reference dosimetry. They were calibrated from the domestic Secondary Standard Dosimetry Laboratory with the same electrometer and cable. These calibrated chambers were used to measure absorbed doses to water in the reference condition for the photon beam of 6 MV and 10 MV and the electron beam of 12 MeV from Siemens ONCOR. The biggest difference among chambers amounts to 2.4% for the 6 MV photon beam, 0.8% for the 10 MV photon beam, and 2.4% for the 12 MeV electron beam. The big deviation in the photon of 6 MV demonstrates that if there had been no problems with the process of measurements application of the same ${\kappa}_{Q,Q_0}$ to the chambers used in this study might have influenced the deviation in the photon 6 MV and that how important an external audit is.

Revenue Determination Model of Raw Ginseng Production (원료삼 생산수익 결정모형)

  • Park, Hoon
    • Journal of Ginseng Research
    • /
    • v.33 no.3
    • /
    • pp.240-243
    • /
    • 2009
  • To better understand how to increase a ginseng grower's revenue, a 4-factor revenue determination model (RDM) of raw ginseng production (R=A Y Q P) was proposed. The total revenue (R) is a multiplicative function of four factors: cultivation area(A), unit yield (Y), quality grade (Q) and unit price (P). The A appears to be a pure capital factor. Y and Q are technological factors and P is social and market factor. When P is constant, the technological term (YQ) is the revenue per unit area (R/A) production efficiency per capital. The RDM appears to be a linear model between R and A with the slope [YQ]. RDM was applied to three farmers' raw ginseng production for assessment of its dependency on capital and technological factors.

The Impact of the Quality Factor of Smart Factory on the Intention to accept Advance Smart Factor: Mediating Effect of Perceived Value and Smart Factory Performance (스마트 팩토리 품질요인이 스마트 팩토리 고도화 의도에 미치는 영향: 지각된 가치 및 스마트 팩토리 성과의 매개효과)

  • Lee, Sangwon
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.5
    • /
    • pp.367-382
    • /
    • 2022
  • This study examined the impact of smart factory's quality factors on the intention to accept Advance Smart Factory(ASF) by mediating Perceived Value(PV) and Smart Factor Performance(SFP) of domestic SMEs that had introduced smart factor. As a result, First, Information Quality(IQ) and Service Quality(SQ) had a significant positive impact on Perceived Value(PV). Second, System Quality(SysQ), IQ, and SQ had a significant positive impact on SFP. Third, PV had a significant positive impact on intention to ASF, and PV and SFP had a significant positive impact on the intention to accept ASP. Also, PV had a mediating effect between SysQ, IS and Perfromance, and PV and Performance had a moderation between SQ and ASF. These results could provide one implication to SMEs that are taking into account to improve their smart factor to be advanced.

KCT첨가에 따른 $(Na,K)NbO_3$ 세라믹스의 압전특성

  • No, Jeong-Rae;Lee, Yu-Hyeong;Ryu, Ju-Hyeon;Yun, Hyeon-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.93-93
    • /
    • 2009
  • In this study, in order to develop excellent lead-free composition ceramics for piezoelectric transformer, $(K_{5.4}Cu_{1.3}Ta_{10}O_{29})$ added $(K_{0.5}Na_{0.5}](Nb_{0.97}Sb_{0.03})O_3$ were fabricated using conventional mixed oxide method. At the 0.9mol% KCT added specimen, electromechanical coupling factor(kp) and mechanical quality factor ($Q_m$) showed the optimal values of 0.437 and 727.07, respectively, for piezoelectric transformer application.

  • PDF

GEANT4-based Monte Carlo Simulation of Beam Quality Correction Factors for the Leksell Gamma Knife® PerfexionTM

  • Schaarschmidt, Thomas;Kim, Tae Hoon;Kim, Yong Kyun;Yang, Hye Jeong;Chung, Hyun-Tai
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1814-1820
    • /
    • 2018
  • With the publication of TRS-483 in late 2017 the IAEA has established an international code of practice for reference dosimetry in small and non-standard fields based on a formalism first suggested by Alfonso et al. in 2008. However, data on beam quality correction factors ($k^{f_{msr},f_{ref}}_{Q_{msr},Q_0}$) for the Leksell Gamma $Knife^{(R)}$ $Perfexion^{TM}$ is scarce and what little data is available was obtained under conditions not necessarily in accordance with the IAEA's recommendations. This study constitutes the first systematic attempt to calculate those correction factors by applying the new code of practice to Monte Carlo simulation using the GEANT4 toolkit. $k^{f_{msr},f_{ref}}_{Q_{msr},Q_0}$ values were determined for three common ionization chamber detectors and five different phantom materials, with results indicating that in most phantom materials, all chambers were well suited for reference dosimetry with the Gamma $Knife^{(R)}$. Similarities and differences between the results of this study and previous ones were also analyzed and it was found that the results obtained herein were generally in good agreement with earlier PENELOPE and EGSnrc studies.

Performance of Respirator Filters Using Quality Factor (qF) (양질계수(Quality Factor)를 이용한 방진마스크 필터의 성능평가)

  • Han, Don-Hee;Jeong, Yoon-Sok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.170-178
    • /
    • 2000
  • Most of manufacturers try to produce the most efficient filter for respirators with the lowest breathing resistance. Filter performance depends on low penetration, i.e., high efficiency (%), and low pressure drop ($mmH_2O$). This study was performed to evaluate performance of respirator filters by quality factor ($q_F$) and suggest the direction for improvement of respirator filters of good quality in Korea. Two mechanical filters, S and K made in Korea, three filtering facepieces, S made in China, C made in Korea and M made in USA, which were widely used in the workplace, were selected and tested efficiency and pressure drop in accordance with flow rate, using with Automated Filter Tester Model 8110 (TSI, USA). The best quality factor within the same respirator filter categories was $0.0672cm^{-1}\;H_2O$ for mechanical filter S, $0.0698cm^{-1}\;H_2O$ for filtering facepiece M at flow rate of 32Lpm. Mechanical filter S would be the best suitable during heavy work since qulity factors decrease less sharply than any others as increased flow rates. It was necessary for mechanical filter S to lower pressure drop without increasing efficiency, but mechanical filter K should be increased efficiency and decreased pressure drop. While filtering facepiece M had the best quality performance of three ones, Sand C should get much higher efficiency and lower pressure for better performance.

  • PDF