• Title/Summary/Keyword: Quality control device

Search Result 434, Processing Time 0.046 seconds

A Study on Quality Evaluation Model of Mobile Device Management for BYOD (BYOD 환경의 MDM 보안솔루션의 품질평가모델에 관한 연구)

  • Rha, HyeonDae;Kang, SuKyoung;Kim, ChangJae;Lee, NamYong
    • The Journal of Korean Association of Computer Education
    • /
    • v.17 no.6
    • /
    • pp.93-102
    • /
    • 2014
  • A mobile office environment using mobile devices, such as tablet PC, mobile phone is gradually increased in enterprises, banking and public institutions etc which is no limitation on places. It occurs advanced and persist security threats that are required effective security management policy and technical solution to be secure. For BYOD (Bring Your Own Device) environment, technical security management solutions of network control based, MDM (Mobile Device Management), MAM (Mobile Application Management), MCM (Mobile Contents Management) were released, evolved and mixed used. In perspective of integrated security management solution, mobile security product should be selected to consider user experience and environment and correct quality evaluation model of product is needed which is provided standards and guidance on the selection criteria when it was introduced. In this paper, the most widely used MDM solution is selected to take a look at its features and it was reviewed the product attributes with related international standard ISO/IEC25010 software quality attributes. And then it was derived evaluation elements and calculated the related metrics based on the quality analysis model. For the verification of quality evaluation model, security checks list and testing procedures were established; it applied metrics and analyzed the testing result through scenario based case study.

  • PDF

A Study on Characteristics of Measuring Roll for Automatic Flatness Control (자동 형상제어용 측정롤의 특성에 관한 연구)

  • 김순경;전언찬;김중완;김문경;이승수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.551-555
    • /
    • 1996
  • The continuing demand for quality products requires better understanding and improved control of the production process. And, in recent year requirements for flatness control in strip rolling have become increasinglysevere because of the control for flatness of cold rolled strip is essential for further down stream processing. Also a speeds of rolling mills to meet productivity requirements puts a demanding requirement on the control of flatness of rolled strip. The demands on a total flatness control system therefore are a measuring and indication system consisting of a measuring roll that is robust, accurate, reliable and require a minimum of maintenance. The critical prt of any control system is the quality of the information being provided by the measurement instrument or device. It is therfore of utmost importance to have an accurate, repeatable and reliable measuring system. So, in this paper, The measuring roll for automatic flatness control system of contact type has been investigated.

  • PDF

Is it Beneficial to Utilize an Articulating Instrument in Single-Port Laparoscopic Gastrectomy?

  • Kim, Amy;Lee, Chang Min;Park, Sungsoo
    • Journal of Gastric Cancer
    • /
    • v.21 no.1
    • /
    • pp.38-48
    • /
    • 2021
  • Purpose: As the number of gastric cancer survivors is increasing and their quality of life after surgery is being emphasized, single-port surgery is emerging as an alternative to conventional gastrectomy. A novel multi-degree-of-freedom (DOF) articulating device, the ArtiSential® device (LivsMed, Seongnam, Korea), was designed to allow more intuitive and meticulous control for surgeons facing ergonomic difficulties with conventional tools. In this study, we evaluated the feasibility of this new device during single-port laparoscopic distal gastrectomy (SP-LDG) for early gastric cancer (EGC) patients. Materials and Methods: Consecutive patients diagnosed with EGC who underwent SP-LDG with ArtiSential® (LivsMed) graspers between April 2018 and August 2020 were enrolled in the study. The clinical outcomes were compared with those of a control group, in which prebent graspers (Olympus Medical Systems Corp) were used for the same procedures. Results: Seventeen patients were enrolled in the ArtiSential® group. There was no significant difference in operative time (205.4±6.0 vs. 218.1±9.9 minutes, P= 0.270) or the quality of surgery, in terms of the number of retrieved lymph nodes (49.5±3.5 vs. 45.9±4.0, P=0.473), length of hospital stay (15.4±2.0 vs. 12.4±1.3 days, P=0.588), and postoperative complications (40.0% vs. 41.2%, P=0.595), between the ArtiSential® group and the control group. Conclusions: The new multi-DOF articulating grasper is feasible and can be used as an alternative for prebent graspers during SP-LDG.

An Experimental Study on the Pond Sediment and Water Quality Purification using Oxygen Solubilization Device(OSD) System (산소용해수를 이용한 호소 저질 및 수질개선에 관한 실험적 연구)

  • Kim, Young-Taek;Bae, Yoon-Sun;Roh, Eun-Kyung;Park, Chul-Hwi;Lee, Yeon-Ku
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.94-103
    • /
    • 2006
  • The pollution in closing water can be caused by not only artificial factor like sewage but also natural factor like elution from sediment. In this study we analyzed Sediment Oxygen Demand (SOD) for verification of sediment purification effect and sediment elution experiment as well as general items like COD, TN, TP, SS to complement and assess the effect of sediment and water quality. The experiment result showed that the release rate of OSD system were 4 times and 3 times as large as control for P and Fe respectively. SOD for operated OSD system and control were $12.18gO_2{\cdot}m^{-2}{\cdot}d^{-1}$ and $47.95gO_2{\cdot}m^{-2}{\cdot}d^{-1}$. From water qualities analyzed by COD, TN, TP, SS, chlorophyll-a, the removal efficiency increase of TN, TP, chlorophyll-a and COD were about 10~20%, 40~50% and 10% respectively. In conclusion, OSD can contribute to improvement of both the waterbody and the sediment environment effectively.

Development of Composting Technology in Animal Waste Treatment - Review -

  • Haga, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.4
    • /
    • pp.604-606
    • /
    • 1999
  • Solid animal wastes in Japan are treated mainly by composting. The composting process under controlled conditions is able to convert the wastes into high-quality organic fertilizer. Various types of composting facilities with/without forced aeration and turning device are available. Characterization of the maturing process during composting was studied, to improve the quality of compost and to make the degree of maturity. Recycling of animal wastes as compost without any environmental pollution will be closely related to the development of sustainable agriculture with organic fertilizer in Japan.

ANALYSIS OF THE IMAGE SENSOR CONTROL METHOD

  • Park, Jong-Euk;Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Yong, Sang-Soon
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.464-467
    • /
    • 2007
  • All image data acquisition systems for example the digital camera and digital camcorder, use the image sensor to convert the image data (light) into electronic data. These image sensors are used in satellite camera for high quality and resolution image data. There are two kinds of image sensors, the one is the CCD (charge coupled device) detector sensor and the other is the CMOS (complementary metal-oxide semiconductor) image sensor. The CCD sensor control system has more complex than the CMOS sensor control system. For the high quality image data on CCD sensor, the precise timing control signal and the several voltage sources are needed in the control system. In this paper, the comparison of the CCD with CMOS sensor, the CCD sensor characteristic, and the control system will be described.

  • PDF

Continuous Subcutaneous Administration of Morphine Using Patient Controlled Analgesia Device for Control of Cancer Pain (암성 통증 조절을 위한 자가통증조절장치를 이용한 몰핀의 지속적 피하투여 -증례 보고-)

  • Lee, Kyong-Ho;Lee, Cheol;Kim, Won-Tae
    • The Korean Journal of Pain
    • /
    • v.11 no.2
    • /
    • pp.321-325
    • /
    • 1998
  • Most of the patients with pain resulting from advanced cancer need opioid for adequate analgesia. Various Methods of drug administration to control the pain have been developed. One of them, continuous administration of intravenous morphine is used for more effective pain control in the patient with severe pain that cannot be satisfactorily controlled by other Methods of morphine administration. But this is not a suitable method at home because of the possibility of serious infectious complications and the difficulty in managing intravenous access by untrained personnel. Continuous subcutaneous adminstration of drugs can not only overcome such disadvantages of continuous intravenous infusion but also get almost the same effect of pain control as continuous intravenous infusion, and allows opportunity to move freely and return home, improving quality of life. We used continuous subcutaneous morphine and metoclopramide in the patients with cancer pain via a portable PCA device, and accomplished satisfactory pain relief without significant side effect.

  • PDF

Best Site Identification for Spatially Distributed On-Site Stormwater Control Devices in an Urban Drainage System (도시유역에서 공간적으로 분포된 소규모 강우유출수 관리시설의 최적설치위치선정)

  • Kim, Sangdan;Lim, Yong Kun;Kim, Jin Kwan;Kang, Dookee;Seo, Seongcheol;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.986-993
    • /
    • 2010
  • Spatially distributed on-site devices such as bioretentions and bioboxfilters are becoming more common as a means of controlling urban stormwater quality. One approach to modeling the cumulative catchment-scale effects of such devices is to resolve the catchment down to the scale of a land parcel or finer, and then to model each device separately. The focus of this study is to propose a semi-distributed model for simulating urban stormwater quantity and identifying best sites for spatially distributed on-site stormwater control devices in an urban drainage system. A detailed model for urban stormwater improvement conceptualization simulation is set up for a $0.9342km^2$.

A Study on the Fabrication and Comparison of the Phantom for Computed Tomography Image Quality Measurements Using Three-Dimensions Printing Technology (삼차원 프린팅 기술을 이용한 전산화단층영상 품질 측정용 팬텀 제작 및 비교 연구)

  • Yoon, Myeong-Seong;Hong, Soon-Min;Heo, Yeong-Cheol;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.595-602
    • /
    • 2018
  • Quality control (QC) of Computed Tomography (CT) devices is based on image quality measurement on AAPM CT phantom which is a standard phantom. Although it is possible to control the accuracy of the CT apparatus, it is expensive and has a disadvantage of low penetration rate. Therefore, in this study, we make image quality measurement phantom at low cost using FFF (Fused Filament Fabrication) type three-dimensional printer and try to analyze the usefulness, compare it with existing standard phantom. To print a phantom, We used three-dimensional printer of the FFF system and PLA (Poly Lactic Acid, density: $1.24g/cm^3$) filament, and the CT device of 64 MDCT (Aquilion CX, Toshiba, Japan). In addition, we printed a phantom using three-dimensional printer after design using various tool based on existing standard phantom. For image quality evaluation, AAPM CT phantom and self-generated phantom were measured 10 times for each block. The measured data were analyzed for significance using the Mannwhiteney U-test of SPSS (Version 22.0, SPSS, Chicago, IL, USA). As a result of the analysis, phantom fabricated with three-dimensional printer and standard phantom showed no significant difference (p>0.05). Furthermore, we confirmed that image quality measurement performance of a phantom using three-dimensional printer is similar to the existing standard phantom. In conclusion, we confirmed the possibility of low cost phantom fabrication using three dimensional printer.

Quality of Service Tradeoff in Device to Device Communication Underlaid Cellular Infrastructure

  • Boabang, Francis;Hwang, Won-Joo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.591-593
    • /
    • 2016
  • Device-to-device (D2D) communications underlaid cellular infrastructure is an competitive local area services technology to promote spectrum usage for next generation cellular networks. These potential can only be tap through efficient interference coordination. Previous works only concentrated on interference from D2D pairs whiles interference from CUs to D2D pairs were neglected. This work focus on solving uplink interference problem emanating from multiple CUs sharing its resource with multiple D2D pairs. The base station (BS) acting as a supervisor selfishly institute a pricing scheme to manage the interference it experience from D2D pairs based on its Quality of service (QoS) requirement. D2D pairs following the supervisor make power allocation decisions considering the price from the BS in a non-cooperative game fashion. In order for the D2D pairs to also meet their QoS requirement, they suggest a price to the BS called discount price which reflects the interference they receive from the CUs. Finally, we analyze the proposed approach.

  • PDF