• Title/Summary/Keyword: Quality assurance system

Search Result 643, Processing Time 0.025 seconds

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

Classification of submitted KSNMT dissertation (대한핵의학기술학회 투고 논문 분류)

  • Han, Dong-Chan;Lee, Hyuk;Hong, Gun-Chul;Ahn, Byeong-Ho;Choi, Seong-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.65-69
    • /
    • 2017
  • Purpose KSNMT(Korea Society of Nuclear Medicine Technology) stepping first step in 1997, has published first journal related with nuclear medicine technology in 1985. With classifying In Vivo Session Dissertation reported in the entire journal, trend of the Dissertation will be studied. Materials and Methods Dissertations which published from 1985 to first half of 2016 in the journal are classified with presentation form and with scanner, And all the data is organized with Excel program. Through the data, the number of dissertations published in each year, the number of dissertation published in details, and keyword distributions in each period are analyzed. Results The number of In-vivo section dissertations was 1151 and the number of In-vivo section dissertations that have common subject with In-vitro section was 28. The number of In-vivo section dissertation in 1980s was 46, in 1990s was 149, in 2000 was 467 and from 2010 to the first half of 2016 was 517. The number of dissertation with original articles was 571, with abstract was 529, with symposium was 31, with special lecture was 25, with review was 11, with interesting image was 7, with poster was 3 and with case report was 2. With symposium and special lecture excluded, which count 56, the number of dissertation with PET was 319, with Planar was 302, with SPECT was 172, with radiopharmaceutical was 113, with guard and safety management 103, with BMD was 28, etc. was 86. The number of dissertation about oncology was 201, about scanner was 179, about cardiovascular and circulatory system was 102, about safe environment was 82, about musculoskeletal system was 76, about nervous nuclear medicine was 66, about quality assurance was 61, about genitourinary system was 56, about endocrine system was 49, about digestive system was 44, about Therapy, about industrial safety was 24, about molecular imaging was 15, infection and inflammation was 9, about respiratory system was 8 and etc. was 108. The mostly used keyword through 1999 to 2005 was PET and through 2006 to 2016 was PET/CT. Conclusion To encourage various dissertations to be submitted, Korea Society of Nuclear Medicine should analyze date about not only about dissertations that are already published, but also about various research materials. Moreover, Korea Society of Nuclear Medicine also have to provide technical support such as sharing big data from homepage and systematical support to its member to publish dissertation that has high impact factor. It is important each individual researcher to have continuing effort as well as each organization cooperation.

  • PDF

Suggestions for improving data quality assurance and spatial representativeness of Cheorwon AAOS data (철원 자동농업기상관측자료의 품질보증 및 대표성 향상을 위한 제언)

  • Park, Juhan;Lee, Seung-Jae;Kang, Minseok;Kim, Joon;Yang, Ilkyu;Kim, Byeong-Guk;You, Keun-Gi
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.1
    • /
    • pp.47-56
    • /
    • 2018
  • Providing high-quality meteorological observation data at sites that represent actual farming environments is essential for useful agrometeorological services. The Automated Agricultural Observing System (AAOS) of the Korean Meteorological Administration, however, has been deployed on lawns rather than actual farm land. In this study, we show the inaccuracies that arise in AAOS data by analyzing temporal and vertical variation and by comparing them with data recorded by the National Center for AgroMeteorology (NCAM) tower that is located at an actual farming site near the AAOS tower. The analyzed data were gathered in August and October (before and after harvest time, respectively). Observed air temperature and water vapor pressure were lower at AAOS than at NCAM tower before and after harvest time. Observed reflected shortwave radiation tended to be higher at AAOS than at NCAM tower. Soil variables showed bigger differences than meteorological observation variables. In August, observed soil temperature was lower at NCAM tower than at AAOS with smaller diurnal changes due to irrigation. The soil moisture observed at NCAM tower continuously maintained its saturation state, while the one at AAOS showed a decreasing trend, following an increase after rainfall. The trend changed in October. Observed soil temperature at NCAM showed similar daily means with higher diurnal changes than at AAOS. The soil moisture observed at NCAM was continuously higher, but both AAOS and NCAM showed similar trends. The above results indicate that the data gathered at the AAOS are inaccurate, and that ground surface cover and farming activities evoke considerable differences within the respective meteorological and soil environments. We propose to shift the equipment from lawn areas to actual farming sites such as rice paddies, farms and orchards, so that the gathered data are representative of the actual agrometeorological observations.

How to Implement Quality Pediatric Palliative Care Services in South Korea: Lessons from Other Countries (한국 소아청소년 완화의료의 발전 방안 제언: 국외 제공체계의 시사점을 중심으로)

  • Kim, Cho Hee;Kim, Min Sun;Shin, Hee Young;Song, In Gyu;Moon, Yi Ji
    • Journal of Hospice and Palliative Care
    • /
    • v.22 no.3
    • /
    • pp.105-116
    • /
    • 2019
  • Purpose: Pediatric palliative care (PPC) is emphasized as standard care for children with life-limiting conditions to improve the quality of life. In Korea, a government-funded pilot program was launched only in July 2018. Given that, this study examined various PPC delivery models in other countries to refine the PPC model in Korea. Methods: Target countries were selected based on the level of PPC provided there: the United Kingdom, the United States, Japan, and Singapore. Relevant literature, websites, and consultations from specialists were analyzed by the integrative review method. Literature search was conducted in PubMed, Google, and Google Scholar, focusing publications since 1990, and on-site visits were conducted to ensure reliability. Analysis was performed on each country's process to develop its PPC scheme, policy, funding model, target population, delivery system, and quality assurance. Results: In the United Kingdom, community-based free-standing facilities work closely with primary care and exchange advice and referrals with specialized PPC consult teams of children's hospitals. In the United States, hospital-based specialized PPC consult teams set up networks with hospice agencies and home healthcare agencies and provide PPC by designating care coordinators. In Japan, palliative care is provided through several services such as palliative care for cancer patients, home care for technology-dependent patients, other support services for children with disabilities and/or chronic conditions. In Singapore, a home-based PPC association plays a pivotal role in providing PPC by taking advantage of geographic accessibility and cooperating with tertiary hospitals. Conclusion: It is warranted to identify unmet needs and establish an appropriate PPD model to provide need-based individualized care and optimize PPC in South Korea.

Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target (표적의 길이가 긴 환자의 용적회전변조 방사선치료 시 6DoF Couch의 유용성 평가)

  • Choi, Young Se;Park, Hyo Kuk;Kim, Se Young;Kim, Joo Ho;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.53-64
    • /
    • 2017
  • Purpose: To evaluate the usefulness of the $HexaPOD^{TM}$ evo RT system(6DoF couch) and the tendency of dose difference according to size of rotational direction error for volumetric rotational modulated radiotherapy(V-MAT) in patients with long target lengths. Therefore, it is suggested to recommend the need for rotational error correction. Materials and Methods: Ten patients with Esophagus cancer or Breast cancer including SCL treated with HexaPOD 6DoF(Six-Degree of Freedom) couch were included in this study. 6DoF couch was used to measure the difference in dose according to the rotation error in the directions of Rx(pitch), Ry(roll), and Rz(yaw). Each rotation error was applied. Positioning variation on x, y and z axis was verified and random variations were made by 6DoF couch with positioning variation. Modified DQA is conducted and point dose and gamma value are analyzed and compared. In addition, after applying the rotation error every $1^{\circ}$ to treatment plans of each target with a diameter of 3 cm, 5, 10, 15, and 20 cm respectively, gamma passing rate is being monitored by its aspect of change according to types and sizes of the target length and rotation error. Results: Mean error of the point dose and Gamma passing rate when the position variation was applied were $2.50{\pm}1.11%$ and $84.1{\pm}7.39%$ in the Rx direction, $2.36{\pm}1.16%$, and $81.0{\pm}8.49%$ in the Ry, $2.35{\pm}1.10%$ and $84.4{\pm}6.99%$ in the Rz direction, respectively. As a result of analysis on gamma passing rate according to types and sizes of the target length and rotation error, the gamma passing rate tended to decrease with increasing rotation error in the Rx and Rz directions except Ry direction. In particular, the lowest gamma passing rate (74.2 %) was in the case of $2.5^{\circ}$ rotation error in Rz direction of the target of 10 cm. Conclusion: The correction of the rotational error is needed for volumetric modulated radiotherapy of the treatment area with a long target length, and the use of 6DoF couch will improve the reproducibility of the patient position and the quality of the treatment.

  • PDF

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

A study on the Regulatory Environment of the French Distribution Industry and the Intermarche's Management strategies

  • Choi, In-Sik;Lee, Sang-Youn
    • The Journal of Industrial Distribution & Business
    • /
    • v.3 no.1
    • /
    • pp.7-16
    • /
    • 2012
  • Despite the enforcement of SSM control laws such as 'the Law of Developing the Distribution Industry (LDDI)' and 'the Law of Promoting Mutual Cooperation between Large and Small/medium Enterprises (LPMC)' stipulating the business adjustment system, the number of super-supermarkets (SSMs) has ever been expanding in Korea. In France, however, Super Centers are being regulated most strongly and directly in the whole Europe viewing that there is not a single SSM in Paris, which is emphasized to be the outcome from French government's regulation exerted on the opening of large scale retail stores. In France, the authority to approve store opening is deeply centralized and the store opening regulation is a socio-economic regulation driven by economic laws whereas EU strongly regulates the distribution industry. To control the French distribution industry, such seven laws and regulations as Commission départementale d'urbanisme commercial guidelines (CDLIC) (1969), the Royer Law (1973), the Doubin Law (1990), the Sapin Law (1993), the Raffarin Law (1996), solidarite et renouvellement urbains (SRU) (2000), and Loi de modernisation de l'économie (LME) (2009) have been promulgated one by one since the amendment of the Fontanet guidelines, through which commercial adjustment laws and regulations have been complemented and reinforced while regulatory measures have been taken. Even in the course of forming such strong regulatory laws, InterMarche, the largest supermarket chain in France, has been in existence as a global enterprise specialized in retail distribution with over 4,000 stores in Europe. InterMarche's business can be divided largely into two segments of food and non-food. As a supermarket chain, InterMarche's food segment has 2,300 stores in Europe and as a hard-discounter store chain in France, Netto has 420 stores. Restaumarch is a chain of traditional family restaurants and the steak house restaurant chain of Poivre Rouge has 4 restaurants currently. In addition, there are others like Ecomarche which is a supermarket chain for small and medium cities. In the non-food segment, the DIY and gardening chain of Bricomarche has a total of 620 stores in Europe. And the car-related chain of Roady has a total of 158 stores in Europe. There is the clothing chain of Veti as well. In view of InterMarche's management strategies, since its distribution strategy is to sell goods at cheap prices, buying goods cheap only is not enough. In other words, in order to sell goods cheap, it is all important to buy goods cheap, manage them cheap, systemize them cheap, and transport them cheap. In quality assurance, InterMarche has guaranteed the purchase safety for consumers by providing its own private brand products. InterMarche has 90 private brands of its own, thus being the retailer with the largest number of distributor brands in France. In view of its IT service strategy, InterMarche is utilizing a high performance IT system so as to obtainas much of the market information as possible and also to find out the best locations for opening stores. In its global expansion strategy of international alliance, InterMarche has established the ALDIS group together with the distribution enterprises of both Spain and Germany in order to expand its food purchase, whereas in the non-food segment, it has established the ARENA group in alliance with 11 international distribution enterprises. Such strategies of InterMarche have been intended to find out the consumer needs for both price and quality of goods and to secure the purchase and supply networks which are closely localized. It is necessary to cope promptly with the constantly changing circumstances through being unified with relevant regions and by providing diversified customer services as well. In view of the InterMarche's positive policy for promoting local partnerships as well as the assistance for enhancing the local economic structure, implications are existing for those retail distributors of our country.

  • PDF

Simplistic QA for an Enhanced Dynamic Wedge using the Reversed Wedge Pair Method (역방향 조사방식을 통한 동적쐐기의 품질관리)

  • Lee Jeong Woo;Hong Semie;Suh Tae Suk
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.161-166
    • /
    • 2004
  • A simplistic quality assurance (QA) method was designed for a Linac built-in enhanced dynamic wedge (EDW), which can be utilized to make wedged beam distributions. For the purpose of implementing the EDW symmetry QA, a film dosimetry system, low speedy dosimetry film, film densitometer and 3D RTP system were used, and the films irradiated by means of a 60$^{\circ}$ Reversed wedge pair (REWP) method. The profiles were then analyzed in terms of their symmetries, including partial treatment, which is the case of stopping it abruptly during EDW irradiation, and the measured and calculated values compared using the Cad Plan Golden Segmented Treatment Table (Golden STT). The result of this experiment was in good agreement, within 1 %, of the 'reversed wedge pair counterbalance effect'. For the QA of the effective wedge factor (EWF), the authors measured EWFs in relation to the 10$^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, 25$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$ EDW, which were compared with the calculated values using the correction factor derived from the Golden STT and the log files produced automatically during the process of EDW irradiation. By means of this method it was capable of check up the safety of effective wedge factor without any other dosimetry system. The EDW QA was able to be completed within 1 hour from irradiation to analysis as a consequence of the simplified QA procedure, with maximized effectiveness. Unlike the metal wedge system, the EDW system was heavily dependent on the dose rates and jaw movements; therefore, its features could potentially cause inaccuracy. The frequent simplistic QA for the EDW is essential, and could secure against the flaw of dynamic treatment that uses the EDW.

  • PDF

Evaluation of the Accuracy for Respiratory-gated RapidArc (RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.127-132
    • /
    • 2013
  • The position of the internal organs can change continually and periodically inside the body due to the respiration. To reduce the respiration induced uncertainty of dose localization, one can use a respiratory gated radiotherapy where a radiation beam is exposed during the specific time of period. The main disadvantage of this method is that it usually requests a long treatment time, the massive effort during the treatment and the limitation of the patient selection. In this sense, the combination of the real-time position management (RPM) system and the volumetric intensity modulated radiotherapy (RapidArc) is promising since it provides a short treatment time compared with the conventional respiratory gated treatments. In this study, we evaluated the accuracy of the respiratory gated RapidArc treatment. Total sic patient cases were used for this study and each case was planned by RapidArc technique using varian ECLIPSE v8.6 planning machine. For the Quality Assurance (QA), a MatriXX detector and I'mRT software were used. The results show that more than 97% of area gives the gamma value less than one with 3% dose and 3 mm distance to agreement condition, which indicates the measured dose is well matched with the treatment plan's dose distribution for the gated RapidArc treatment cases.

Privilege and Immunity of Information and Data from Aviation Safety Program in Unites States (미국 항공안전데이터 프로그램의 비공개 특권과 제재 면제에 관한 연구)

  • Moon, Joon-Jo
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.23 no.2
    • /
    • pp.137-172
    • /
    • 2008
  • The earliest safety data programs, the FDR and CVR, were electronic reporting systems that generate data "automatically." The FDR program, originally instituted in 1958, had no publicly available restrictions for protections against sanctions by the FAA or an airline, although there are agreements and union contracts forbidding the use of FDR data for FAA enforcement actions. This FDR program still has the least formalized protections. With the advent of the CVR program in 1966, the precursor to the current FAR 91.25 was already in place, having been promulgated in 1964. It stated that the FAA would not use CVR data for enforcement actions. In 1982, Congress began restricting the disclosure of the CVR tape and transcripts. Congress added further clarification of the availability of discovery in civil litigation in 1994. Thus, the CVR data have more definitive protections in place than do FDR data. The ASRS was the first non-automatic reporting system; and built into its original design in 1975 was a promise of limited protection from enforcement sanctions. That promise was further codified in an FAR in 1979. As with the CVR, from its inception, the ASRS had some protections built in for the person who might have had a safety problem. However, the program did not (and to this day does not) explicitly deal with issues of use by airlines, litigants, or the public media, although it appears that airlines will either take a non-punitive stance if an ASRS report is filed, or the airline may ignore the fact that it has been filed at all. The FAA worked with several U.S. airlines in the early 1990s on developing ASAP programs, and the FAA issued an Advisory Circular about the program in 1997. From its inception, the ASAP program contained some FAA enforcement protections and company discipline protections, although some protection against litigation disclosure and public disclosure was not added until 2003, when FAA Order 8000.82 was promulgated, placing the program under the protections of FAR 193, which had been added in 2001. The FOQA program, when it was first instituted through a demonstration program in 1995, did not contain protections against sanctions. Now, however, the FAA cannot take enforcement action based on FOQA safety data, and an airline is limited to "corrective action" under the program. Union contracts can exclude FOQA from the realm of disciplinary action, although airline practice may be for airlines to require retraining if there is no contract in place forbidding it. The data is protected against disclosure for litigation and public media purposes by FAA Order 8000.81, issued in 2003, which placed FOQA under the protections of FAR 193. The figure on the next page shows when each program began, and when each statute, regulation, or order became effective for that program.