• Title/Summary/Keyword: Quality assurance system

Search Result 643, Processing Time 0.023 seconds

Optimal Resolution of Aerial Photo for Construction of Image Database (영상데이타베이스 구축을 위한 항공사진의 최적해상도)

  • Lee, Hyun-Jik;Lee, Seung-Ho;Park, Hong-Gi
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.8 no.2 s.16
    • /
    • pp.89-99
    • /
    • 2000
  • The Quality and Accuracy of digital image is important factor for decision of accuracy in digital photogrammetry because all the inside works in digital photogrammetry are based on digital image. But it is still difficult to ensure quality assurance and appication of data because there is no distinct criterion about quality and accuracy of digital image when the works in digital photogrammetry is accomplished. This study presents optimal resolution of aerial photo through error analysis of image coordinate using auto inner orientation in digital photograrnrnetry workstation. In second step, we are valified to optimum resolution of aerial photo image with orientation analysis. Finally, we are established to validity optimal resolution of aerial photo image with production of ortho image and mosaic image using optimal resolution aerial photo image.

  • PDF

Analysis and Consideration of the Establishment of a Multiplexed Channel for Domestic RI Waste Nuclide Analysis (국내 방사성동위원소(RI) 폐기물 핵종분석 다중화채널 구축 성과 분석 및 고찰)

  • Han, Sang-Jun;Lee, Hong-Yeon;Kim, Bo-Gil;An, Eun-Mi
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.351-358
    • /
    • 2021
  • This research project is a program promoted to seek diversification of domestic radioactive waste analysis institutions, and seeks public development, win-win cooperation, and cooperation between the entrusted institution and the entrusted institution. Accordingly, the entrusted institution established a standard analysis procedure for establishing a quality control system for radioactivity analysis, establishing a radiation control zone, obtaining KOLAS accreditation, and performing proficiency tests, which are the performance ranges requested by the entrusted institution, and intersecting the radioactive isotope waste generated at the actual site. Verification was performed to confirm the analysis quality. In addition, facilities and equipment for radioactivity analysis were supplemented and expanded, and the basic technology foundation and technical skills were secured through securing professional technicians and education/training. It is judged that the entrusted institution will contribute to securing radiation safety through the smooth execution of treatment, disposal, and transportation through value creation and analysis of radioactive waste generated by radioactive isotope-using institutions (research institutes, hospitals, industries, etc.) by succeeding in this research project do.

Quality Improvement Priorities for Cosmetic Medical Service Using Kano Model and Potential Customer Satisfaction Improvement Index (Kano 모델 및 잠재적 고객만족 개선 지수를 이용한 미용성형의료서비스 품질 개선 우선순위)

  • Park, Youyoung;Jung, Hunsik
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.3
    • /
    • pp.176-183
    • /
    • 2019
  • The environmental changes in the Korean cosmetic medical service industry in the $21^{st}$ century are forming intense competition among medical institutions due to the quantitative expansion of its market. For stable growth of the cosmetic medical service industry, continuous quality improvement is necessary based on empirical research on the quality of cosmetic medical services rather than external expansion. The purpose of this study is to classify the quality attributes of cosmetic medical service using Kano model and to derive the degree of satisfaction and dissatisfaction of each quality attributes through Customer Satisfaction Coefficient (CSC). Through this, the study identified strategic priorities and suggested specific step-by-step approaches and quality improvement priorities that can increase customer satisfaction using the Potential Customer Satisfaction Improvement Index (PCSI Index). Based on SERVPERF, this study used measurement tools consisting of five dimensions : tangibles, reliability, responsiveness, assurance, and empathy. In addition, it was used of measurement items reconstructed into positive, negative, and satisfaction questions for Kano model analysis, CSC analysis, and PCSI Index analysis. A total of 300 medical consumers who experienced cosmetic medical services for the past one year in medical institutions such as plastic surgery and dermatology were collected with convenient sampling. As a result, urgent items for improving the quality of service using the PCSI Index, 'Consideration for customer benefits' in empathy category was followed by 'Immediate help' and 'Sincere response' in responsiveness category, and 'Understanding customer needs' in empathy category, respectively. That is, it is required to improve human service quality attributes such as empathy and responsiveness rather than physical service quality attributes. This study contributes practically in that it provides specific and discriminatory approaches to improve customer satisfaction on cosmetic medical service quality and suggests improvement priorities.

Development of 2D Data Quality Validation Techniques for Pipe-type Underground Facilities (2차원 관로형 지하시설물 정보 품질검증기술 개발)

  • Sang-Keun Bae;Sang-Min Kim;Eun-Jin Yoo;Keo-Bae Lim;Da-Woon Jeong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.285-292
    • /
    • 2023
  • As various accidents have occurred in underground spaces, we aim to improve the quality validation standards and methods as specified in the Regulations on Producing Integrated Map of Underground Spaces devised by the Ministry of Land, Infrastructure and Transport of the Republic of Korea for a high-quality integrated map of underground spaces. Specifically, we propose measures to improve the quality assurance of pipeline-type underground facilities, the so-called life lines given their importance for citizens' daily activities and their highest risk of accident among the 16 types of underground facilities. After implementing quality validation software based on the developed quality validation standards, the adequacy of the validation standards was demonstrated by testing using data from two-dimensional water supply facilities in some areas of Busan, Korea. This paper has great significance in that it has laid the foundation for reducing the time and manpower required for data quality inspection and improving data quality reliability by improving current quality validation standards and developing technologies that can automatically extract errors through software.

A Study on the Environment Test Support for Small and Medium Defense Companies to Improve Weapon System Reliability (무기체계 신뢰성 향상을 위한 중소 방산업체 환경시험 지원방안 고찰)

  • Hwang, Kyunghwan;Kim, Bohyeon;Hur, Jangwook
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.287-294
    • /
    • 2016
  • Purpose: Environment test support is urgent for small and medium defense companies in order to improve the reliability of weapons systems. Also, to reduce the burden of test costs, the voucher system must be strengthened. Quality assurance support should be accompanied by budget support. Methods: First of all, it is necessary to expand infrastructure for test equipment that suffers shortages by considering environmental test frequency and waiting periods to reduce the time required for environmental tests. Results: In regard to the environmental test, expansion for test equipment infrastructure, security of budget for the test, establishment of test plan, education and consulting support are required to resolve some limits of small and medium defense companies. Conclusion: Along with the opening of environmental test courses for industry operators, the expansion for consulting support projects of the defense industry support system is needed.

The Embdedded Software of Development Process & Quality Evaluation Method (임베디드 소프트웨어의 개발 프로세스와 품질평가방법)

  • Yu, Jin Jin;Sool, Yang-Hae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.6
    • /
    • pp.95-105
    • /
    • 2008
  • Recently use of embedded software has been increased to different areas. The requirements and demands for the embedded software have also been altered. In the past, the embedded system was used in simple task and small portable devices but now, the usage of the embedded software has expanded to do much more complex and precise actions in a variety platform environment. The embedded software enables multiple softwares to be integrated into one and at the same time, control it. Currently the biggest challenges embedded software is facing during its development process is the improvement in product production and quality assurance. Our research team has developed an embedded software based on the component (technology or methodology) which both improves production capabilities as well as quality. Additionally, we also established and constructed a reliability test system which can effectively test the quality of the developed embedded software to further increase its competiveness.

  • PDF

Agrometeorological Observation Environment and Periodic Report of Korea Meteorological Administration: Current Status and Suggestions (기상청의 농업기상 관측환경과 정기보고서: 현황 및 제언)

  • Choi, Sung-Won;Lee, Seung-Jae;Kim, Joon;Lee, Byong-Lyol;Kim, Kyu-Rang;Choi, Byoung-Choel
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.2
    • /
    • pp.144-155
    • /
    • 2015
  • Since the relocation project of equipment in 2011, the overall circumstances of KMA's agrometeorological observation have been significantly improved. Some concerns, however, emerged as a result of the evaluation of observational circumstances in terms of quality assurance after the field surveys on all stations. In order to improve the situation, we suggest: (1) establishment of clear management responsibilities, (2) enhancement of mutual cooperation system between relevant organizations, (3) detailed records of the changes in the observational circumstances, (4) standardization of equipment and sensors, (5) installation of unified information boards, (6) transfer of inappropriate facilities to an adjacent cropland and (7) setup of automated evaporation pan. In order to effectively utilize the high-quality data obtained through improvement of observational circumstances and an elaborate quality control, it is recommended to publish and disseminate regular reports on agrometeorological observations. To produce such a report on a trial basis, we have investigated different types of regular reports issued by domestic and foreign organizations, publication periods, geographical scope, main contents and amount. Based on our current situation, it would be beneficial to learn from the cases of Germany and Canada, which summarize mainly the distinctive agrometeorological phenomena occurred over the past years across the country.

A Study on the Advancement of Accreditation Systems and Surveyors' Expertise for Long-term Care Facilities: Focusing on Overseas Cases (해외 사례 고찰을 통한 지자체 노인요양시설 인증 체계 및 조사원 고도화 방안)

  • Seo, Yun Jeong;Lee, Soonsung;Seo, Dong-Min;Yoon, Ju Young;Sagong, Hae;Kim, Da Eun
    • Perspectives in Nursing Science
    • /
    • v.15 no.2
    • /
    • pp.81-91
    • /
    • 2018
  • Purpose: This study aimed to suggest strategies for advancing local-government-based accreditation systems and surveyor training in long-term care facilities in Korea. Methods: A comprehensive review of the literature including research papers and official reports issued by governments from the United States, Australia, and Japan was conducted to explore domestic and international policies related to long-term care facility certification and accreditation systems. Results: The USA has two types of care quality assurance systems including mandatory certification (5-star rating system) by the Centers for Medicare and Medicaid Services and voluntary accreditation by the Joint Commission on Accreditation of Healthcare Organizations. Australia operates a government-based mandatory accreditation system for all long-term care facilities through the Australian Aged Care Quality Agency. Japan, particularly the Tokyo district, operates a third-party evaluation system that involves the voluntary participation of long-term care facilities. Conclusion: This study provides several strategies to enhance accreditation processes and surveyors'expertise. For instance, motivating facilities to voluntarily participate in accreditation is necessary by 1) providing sufficient and continuous consultations and feedback about how to improve care quality, 2) differentiating accreditation domains and indicators from the national health insurance certification system, and 3) actively utilizing accreditation results and providing incentives.

Efficacy of new inspection system of Anticancer Drug Prescription (새로운 항암제 처방 감사 시스템 도입을 통한 의료의 질 향상)

  • Kim, M.S.;Kim, Y.K.;Lee, Y.J.;Choi, Y.J.;Shin, H.Y.;Song, Y.C.
    • Quality Improvement in Health Care
    • /
    • v.14 no.2
    • /
    • pp.125-132
    • /
    • 2008
  • Background : The number of outpatient injected anticancer drug is increasing. and the pathway of prescribing, compounding, and injecting anticancer drug is processed very rapidly in out-patient department. Moreover, Dose of anticancer drug is often changed depending on side effect of patients. So we need more effective inspection of anticancer drug prescriptions. The purpose of this study was to analyze the prescription errors for anticancer drugs in Out-Patient Department and to suggest system to prevent them. Method : The study took place at Asan Medical Center from July to September 2007. The pharmacists performed inspection of anticancer drug prescriptions before compounding and injecting. We used protocol-based anticancer drug order program and Electronic Medical Record (EMR). Result : During the study period, we analyzed 4683 prescriptions for out-patient. And we detected 55 medication errors (1.2%). Most common errors included dosage above or below the correct ones (56.3%), followed by incorrect treatment duration. Because most of dosing errors were in the range of usual dosage, it was hard to detect them. So when inspecting the prescription, we considered the medical records of individual patients. As a result, we could raise the efficiency of intervention. Therefore inspection using EMR could possibly reduce the number of anticancer drug errors. Conclusion : we are preventing the medication errors on stability and dosage above or below the maximum therapeutic dose according to the previous inspection system. However most of dosing errors were in the range of usual dosage according to the result of this study. Because of there was interpatient variability of dosage depending adverse effect. For improvement of quality assurance, we suggest inspection system based on patient's medical history.

  • PDF

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.