• Title/Summary/Keyword: Quality assurance system

Search Result 647, Processing Time 0.027 seconds

A new research program that aims to establish an external audit system to radiotherapy QA in Japan

  • Shimbo, Munefumi;Tabushi, Katsuyoshi;Endo, Masahiro;Ikeda, Hiroshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.17-18
    • /
    • 2002
  • Last year, a three-year research program was started in order to establish an external audit system to radiotherapy QA in Japan. It consists of questionnaire surveys, mailed (off-site) dosimetry and visited (on-site) dosimetry at radiotherapy facilities in Japan. The first questionnaire was sent to all Japanese radiotherapy facilities in October 2001, surveying basic QA procedures at each facility. 628 answers were returned with the return rate of 87%. In February 2002, the second questionnaire was sent. Off-site and on-site dosimetry have been tested in several facilities, and will be started soon. We anticipates that this program will gradually grow to a radiotherapy quality control center similar to Radiological Physics Center at MD Anderson Hospital.

  • PDF

Development of A Lot Quality Assurance and Inspection Cost Estimation System for Process-Centered Inspections (공정 중심의 검사 방식에 대한 로트 품질보증 및 검사비용 추정 시스템 개발)

  • Lee, Do-Kyung;Lee, Seung-Woo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.1
    • /
    • pp.34-40
    • /
    • 2006
  • Many producers put sampling inspection policy into the way of their convenience. Examples of the convenience are irregular lot size and too small sample size. Because they don't use a standard sampling inspection policy, they can not guarantee the quality level of their products. In this study, we developed a user-centered design program which can calculate the AOQL of their products to their buyers in the case of irregular lot size and too small sample size. Also this program propose a linear inspection cost by Hald's model.

Using the Analytical Hierarchy Process as a Tool for Assessing Service Quality

  • Liu, Dahai;Bishu, Ram R.;Najjar, Lotfollah
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.2
    • /
    • pp.129-135
    • /
    • 2005
  • Continuous quality improvement through process refinement is a must for survival of all industries in the contemporary market place. This is true for both manufacturing and service sectors. While manufacturing has spearheaded quality efforts, the service sector has lagged behind primarily because of inherent difficulties. Customer satisfaction is perhaps the most important performance measure for service quality. There are a number of quality dimensions in service quality, such as reliability, responsiveness, assurance, empathy, and tangibles. An issue of concern is ‘how can one have a unified measure of service quality across all the dimensions?' The intent of this paper is to determine if the Analytical Hierarchy Process (AHP) method could be used to derive a single quality index. AHP is a quantitative technique that structures a multi-attribute, multi-person and multi-period problem hierarchically so that solutions are facilitated. This paper presents the development of an AHP model and the derivation of a Quality Index through it. The model is used in a hypothetical case and a quality index was developed. The advantages of using such a technique are discussed.

Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT (PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가)

  • Choong-Woon Lee;Yeon-Wook You;Jong-Woon Mun;Yun-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

The Study on Equipment Qualification of Emergency Diesel Generator Excitation Control System for Nuclear Power Plant (I) (원전 디젤발전기 여자시스템 기기검증시험에 관한 연구(I))

  • Lee, Joo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.143-145
    • /
    • 2007
  • The development of excitation control system (ECS) for emergency diesel generator in nuclear power plant is the replacement project of existing control system to resolve the maintenance problems caused by aging and obsolescence, The excitation control system is classified as a safety-related system. To guarantee the performance of developing excitation control system is equal to or higher than that of other systems, establishing the quality assurance scheme, doing software verification and validation activities, and planning equipment qualification. In this paper, we'd like to introduce the equipment qualification of excitation control system.

  • PDF

Evaluation of Industrial Hygiene Laboratories by on-Site Investigation for Revised Quality Control System (개정된 정도관리제도를 적용한 작업환경측정기관의 실험실 현장 평가)

  • Shin, Jung-Ah;Yi, Gwang-Yong;Park, Seung-Hyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.243-249
    • /
    • 2013
  • Objectives: This study assessed the status of domestic industrial hygiene laboratories using data from on-site investigation for revision of quality control systems in 2012-2013. Methods: The target laboratories were 60 industrial hygiene laboratories chosen by random selection and nationwide distribution which had participated in on-site investigations for revision of quality control systems from March 2012 to August 2013. The investigation was performed on-site following standard quality control procedures. The score between each group was compared using Mann-Whitney and Kruskal-Wallis tests, and the correlation between analytical career, sex, academic major of analyst and score of analytical performance was expressed as Spearman's rank correlation coefficient. Results: The assessment revealed that the items to be improved, in sequence, were effort at staff training (score 65.5), ability to calculate data (score 73.4), establishment of internal quality control guidelines (score 75.7), laboratory facilities (score 77.1), degree of understanding and skill at gas chromatography (score 77.1). Analysis performance showed a positive correlation with career of analyst (r=0.56, p<0.01). Conclusions: The practice of on-site investigation for quality control systems showed the current status of industrial hygiene laboratories in the first trial. There were many laboratories which needed improvement and development of analytical systems. This assessment can provide information for the systematic operation and improvement of facilities at each laboratory. Further practice of this investigation will lead to a proficiency testing and accreditation system for autonomous quality control as is the practice in many countries, rather than mandatory practice by legal regulation.

Systematic Quality Assurance Activity for TDX-10 ISDN Switching System (TDX-10 ISDN 시스템의 시험 및 평가분석 체계화에 따른 품질보증 활동)

  • Lee, Haeryong;Jeong, Taegwon
    • Journal of Korean Society for Quality Management
    • /
    • v.23 no.1
    • /
    • pp.127-141
    • /
    • 1995
  • 대용량 ISDN(Integrated Services Digital Network)용 전전자 교환기 TDX-10 연구개발 사업의 궁극적 목적은 미래 통신망이 요구하는 다양한 음성 및 비음성 정보통신 서비스를 제공하고 정보의 교환, 가공, 축적 및 처리에 고도의 융통성을 부여할 수 있는 국내표준 전전자 교환기를 개발하여 통신투자의 경제적 통신운영기술 자립화를 달성하는데 있다. 현재 대용량 전전자 교환기인 TDX-10 ISDN의 상용화 단계의 마무리 업무가 진행중이며, 통신서비스의 다양화, 광대역화, 고속화를 위한 광대역통신망의 주축이 되는 ATM교환기가 개발중에 있다. 본 고에서는 TDX-10 ISDN 시스템개발단계에서 구현된 시스템 시험수행 과정 및 평가작업을 토대로한 체계적이며 전략적인 품질보증 활동에 관해 기술하였으며, 신뢰성 있는 시험결과를 도출할 수 있는 다양한 시험관리 기법과 그 결과를 분석하고 차후 시험 및 보완작업을 위한 제반 활동체계가 소개된다.

  • PDF

Study on a Procedure to Determine of the Economic Incoming Quantity of Materials in Consideration of the Ingoing-Outgoing Qualify Level (입출검품질을 고려한 자재의 경제적 납입량 결정)

  • 이회식;황의철
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.13 no.21
    • /
    • pp.73-79
    • /
    • 1990
  • The quality and cost of manufacturing products is a significant problem in view of duality assurance, but the quality level of the incoming materials is not considered to determine in the economic order quantity of conservative inventory model. A typical situation we face is the difference of quantity between order quantity and the determined outgoing quantity after acceptance inspection. In this paper we present a procedure to reduce the difference of order(ingoing) quantity and outgoing quantity of incoming materials a method of justifying the acceptance plans whether accept or not by comparing with ingoing outgoing quality.

  • PDF

Vehicle Identification Number Recognition using Edge Projection and PCA (에지 투영과 PCA를 이용한 차대 번호 인식)

  • Ahn, In-Mo;Ha, Jong-Eun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.5
    • /
    • pp.479-483
    • /
    • 2011
  • The automation of production process is actively expanding for the purpose of the cost reduction and quality assurance. Among these, automatic tracking of the product along the whole process of the production is also important topic. Typically this is done by adopting OCR technology. Conventional OCR technology operates well on the rather good quality of the image like as printed characters on the paper. In industrial application, IDs are marked on the metal surface, and this cause the height difference between background material and character. Illumination systems that guarantee an image with good quality may be a solution, but it is rather difficult to design such an illumination system. This paper proposes an algorithm for the recognition of vehicle's ID characters using edge projection and PCA (Principal Component Analysis). Proposed algorithm robustly operates under illumination change using the same parameters. Experimental results show the feasibility of the proposed algorithm.

Product Specification Management in Collaborative NPD: An Investigation of Problems and Good Practices in Electronics Industry

  • Lam, Ping-Kit;Chin, Kwai-Sang;Cheung, Wai-Ying
    • International Journal of Quality Innovation
    • /
    • v.7 no.1
    • /
    • pp.35-47
    • /
    • 2006
  • Client-supplier collaboration has been an imperative approach to new product development (NPD), in which a good product specification management system and practice is crucial to the assurance of product quality. This study investigates product specification management in client-supplier collaborative NPD. Based on the interviews and survey study, 12 problems and 13 good practices of product specification management are identified. It also compares the importance and degree of the implementation of the product specification practices in Hong Kong electronics industry. The results suggest that more intensive practices should be implemented for better product specification management.