• Title/Summary/Keyword: Quality In Use

Search Result 10,649, Processing Time 0.047 seconds

CONDITIONS FOR ALASKA POLLACK AND FILE FISH SKIN GLUE PROCESSING AND THE QUALITY OF PRODUCT (명태피 및 말쥐치피를 이용한 피교의 최적가공조건과 품질에 대하여)

  • LEE Eung-Ho;HA Jin-Whan;HEO Woo-Deock
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 1977
  • The purpose of this study is to complish a method of fish glue malting with residual products such as fish head and skin discarded from sea food processing. Using the skins of Alaska pollack and file fish from fillet packers, the optimum conditions of skin glue processing were investigated and physical and chemical properties of the product were also determined. The yields of Alaska pollack, Thelagra calcogramma, skin and file fish, Novodon modestus, skin to the total body weight were $4.6\%\;and\;5.0\%$ respectively. The optimum conditions for a $49.3\%$n yield Alaska pollack skin glue processing were considered the extraction of previously tinted in $0.1\%$ calcium hydroxide solution for 3 hours with the additional water as much as 3 times of sample weight at $70^{\circ}C$ for 3 hours under the controlled pH 5.0. The conditions for file fish skin glue were similar to those of Alaska pollack except the addition of five times of water to the weight of sample skin needed for extraction. The content of crude protein of Alaska pollack and file fish skin glue were $98.0\%\;and\;96.0\%$ respectively. The contents of crude ash and crude lipid were not different from that of chemical grade gelatin. Relative viscosity, melting point, gelation temperature and jelly strength of Alaska pollack skin glue marked 5.84, $21.8^{\circ}C,\;7.1^{\circ}C\;and\;10.0g$ respectively and those of file fish skin glue showed $5.79,\;25.0^{\circ}C,\;7.4^{\circ}C\;and\;11.6g$ respectively.The color and turbidity of Alaska pollack skin glue are slightly superior to those of file fish skin glue. It is supposed that the extract residue of skin glue is valuable for use the animal feeds by the results of amino acid composition. And the ratio of each amino acid content to the total amino acid of Alaska pollack and file fish skin glue is similar to that of chemical grade gelatin.

  • PDF

Biodegradation of Phenol by Comamonas testosteroni DWB-1-8 Isolated from the Activated Sludge of Textile Wastewater (섬유 폐수 활성 슬러지에서 분리한 Comamonas testosteroni의 생물학적 페놀 분해)

  • Kwon, Hae Jun;Choi, Doo Ho;Kim, Mi Gyeong;Kim, Dong-Hyun;Kim, Young Guk;Yoon, Hyeokjun;Kim, Jong-Guk
    • Journal of Life Science
    • /
    • v.30 no.2
    • /
    • pp.156-161
    • /
    • 2020
  • Since industrialization, the production and utilization of various chemicals has contributed to improving the quality of our lives, but the subsequent discharge of massive waste is inevitable, and environmental pollution is becoming more serious every day. Exposure to chemicals as a result of environmental pollution is having a negative effect on human health and the ecosystem, and cleaning up the polluted environment that can affect our lives is a very important issue. Toxic aromatic compounds have been detected frequently in soil, groundwater, and wastewater because of the extensive use of oil products, and phenol, which is used to produce synthetic resins, textiles, and dyes, is one of the major pollutants, along with insecticides and preservatives. Phenol can cause dyspnea, headache, vomiting, mutation, and carcinogenesis. Phenol-degrading bacterium DWB-1-8 was isolated from the activated sludge of textile wastewater; this strain was identified as Comamonas testosteroni by 16S rRNA gene sequencing. The optimal culture conditions for the cell growth and degradation of phenol were 0.7% K2HPO4, 0.6% NaH2PO4, 0.1% NH4NO3, 0.015% MgSO4·7H2O, 0.001% FeSO4·7H2O, an initial pH of 7, and a temperature of 30℃. The strain was also able to grow by using other toxic compounds, such as benzene, toluene, or xylene (BTX), as the sole source of carbon.

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Fabrication of Strain Sensor Based on Graphene/Polyurethane Nanoweb and Respiration Measurement (그래핀/폴리우레탄 나노웹 기반의 스트레인센서 제작 및 호흡측정)

  • Lee, Hyocheol;Cho, Hyeon-seon;Lee, Eugene;Jang, Eunji;Cho, Gilsoo
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2019
  • The purpose of this study is to develop a strain sensor based on a nanoweb by applying electrical conductivity to a polyurethane nanoweb through the use of Graphene. For this purpose, 1% Graphene ink was pour-coated on a polyurethane nanoweb and post-treated with PDMS (Polydimethylsiloxane) to complete a wearable strain sensor. The surface characteristics of the specimens were evaluated using a field emission scanning electron microscope (FE-SEM) to check whether the conductive material was well coated on the surface of the specimen. Electrical properties of the specimens were measured by using a multimeter to measure the linear resistance of the specimen and comparing how the line resistance changes when 5% and 10% of the specimens are tensioned, respectively. In order to evaluate the performance of the specimen, the gauge factor was obtained. The evaluation of the clothing was performed by attaching the completed strain sensor to the dummy and measuring the respiration signal according to the tension using MP150 (Biopac system Inc., USA) and Acqknowledge (ver. 4.2, Biopac system Inc., U.S.A.). As a result of the evaluation of the surface characteristics, it was confirmed that all the conductive nanoweb specimen were uniformly coated with the Graphen ink. As a result of measuring the resistance value according to the tensile strength, the specimen G, which was treated with just graphene had the lowest resistance value, the specimen G-H had the highest resistance value, and the change of the line resistance value of the specimen G and the specimen G-H is increased to 5% It is found that it increases steadily. Unlike the resistance value results, specimen G showed a higher gauge rate than specimen G-H. As a result of evaluation of the actual clothes, the strain sensor made using the specimen G-H measured the stable peak value and obtained a signal of good quality. Therefore, we confirmed that the polyurethane nanoweb treated with Graphene ink plays a role as a breathing sensor.

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

An Analytical Study on Stem Growth of Chamaecyparis obtusa (편백(扁栢)의 수간성장(樹幹成長)에 관(關)한 해석적(解析的) 연구(硏究))

  • An, Jong Man;Lee, Kwang Nam
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.4
    • /
    • pp.429-444
    • /
    • 1988
  • Considering the recent trent toward the development of multiple-use of forest trees, investigations for comprehensive information on these young stands of Hinoki cypress are necessary for rational forest management. From this point of view, 83 sample trees were selected and cut down from 23-ear old stands of Hinoki cypress at Changsung-gun, Chonnam-do. Various stem growth factors of felled trees were measured and canonical correlaton analysis, principal component analysis and factor analysis were applied to investigate the stem growth characteristics, relationships among stem growth factors, and to get potential information and comprehensive information. The results are as follows ; Canonical correlation coefficient between stem volume and quality growth factor was 0.9877. Coefficient of canonical variates showed that DBH among diameter growth factors and height among height growth factors had important effects on stem volume. From the analysis of relationship between stem-volume and canonical variates, which were linearly combined DBH with height as one set, DBH had greater influence on volume growth than height. The 1st-2nd principal components here adopted to fit the effective value of 85% from the pincipal component analysis for 12 stem growth factors. The result showed that the 1st-2nd principal component had cumulative contribution rate of 88.10%. The 1st and the 2nd principal components were interpreted as "size factor" and "shape factor", respectively. From summed proportion of the efficient principal component fur each variate, information of variates except crown diameter, clear length and form height explained more than 87%. Two common factors were set by the eigen value obtained from SMC (squared multiple correlation) of diagonal elements of canonical matrix. There were 2 latent factors, $f_1$ and $f_2$. The former way interpreted as nature of diameter growth system. In inherent phenomenon of 12 growth factor, communalities except clear length and crown diameter had great explanatory poorer of 78.62-98.30%. Eighty three sample trees could he classified into 5 stem types as follows ; medium type within a radius of ${\pm}1$ standard deviation of factor scores, uniformity type in diameter and height growth in the 1st quadrant, slim type in the 2nd quadrant, dwarfish type in the 3rd quadrant, and fall-holed type in the 4 th quadrant.

  • PDF

Studies on the Properties of Populus Grown in Korea (포플러재(材)의 재질(材質)에 관(關)한 시험(試驗))

  • Jo, Jae-Myeong;Kang, Sun-Goo;Lee, Yong-Dae;Jung, Hee-Suk;Ahn, Jung-Mo;Shim, Chong-Supp
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.68-87
    • /
    • 1982
  • In Korea, this is the situation at moment that the total demand of timber in 1972 is more than 5 million cubic meters. On the other hand, however, the available domestic supply of timber at the same year is only about, 1 million cubic meters. A great unbalancing between demand and supply of timber has been prevailing. To solve this hard problem, it has been necessitiated to build up the forest stocks as early as possible with fast grown species such as poplar. Under circumstances, poplar plantations which have been carryed on government and private have reached to large area of 116,603 hectors from 1962 up to date. It has now be come a principal timber resources in this country, and required the basic study on various properties of wood for it's proper utilization, since it has not been made of any systematic study on the properties of Populus grown in Korea. In order to investigate the properties such as anatomical, physical and mechanical properties of nine different species (P. euramericana Guiner I-214. P. euramericana Guiner I-476, P. deltoides Marsh, P. nigra var. italica (Muchk) Koeme, P. alba L.,P. alba $\times$ glandulosa P. maximowiczii Henry, P. koreana Rehder, P. davidiana Dode) of poplar for their proper use and development of new ways of grading processing and quality improving, this study has been made by the Forest Research Institute.

  • PDF

Effect of Cellulose Derivatives to Reduce the Oil Uptake of Deep Fat Fried Batter of Pork Cutlet (셀룰로오스 유도체가 돈가스 튀김옷의 흡유량 감소에 미치는 영향)

  • Kim, Byung-Sook;Lee, Young-Eun
    • Korean journal of food and cookery science
    • /
    • v.25 no.4
    • /
    • pp.488-495
    • /
    • 2009
  • Pork cutlet is a favorite deep fat fried food item among Korean children, and an excellent protein-containing food, and as well as a simple and economical cuisine. However, the frying process adds a significant amount of calories. We added MC (Methylcellulose) and HPMC (Hydroxypropyl Methylcellulose) to the batter in an effort to reduce oil uptake in prepared pork cutlets. After additions of MC and HPMC at concentrations of 0.5, 1, and 1.5% respectively, we assessed the viscosity of batter, color after frying, the increases in moisture retention and oil uptake, and sensory characteristics, comparing each quality. The viscosity of batter with 0.5% HPMC added (w/w) was similar to that of the controls, but the viscosity of all the batter with added MC was so much higher that it was difficult to use the batter for coating at the same temperature, leading to a failure even to prepare a sample. After frying, the batter with added HPMC provided significantly less oil uptake and more moisture retention than the batter to which MC was added. Additionally, with regard to color and sensory characteristics, the pork cutlet with 0.5% added HPMC was superior to the other samples. According to these results, we concluded that when cellulose derivatives are added in order to reduce oil uptake and to raise the moisture retention of the batter of pork cutlet, HPMC is more useful in this regard than MC. Additionally, the batter with 0.5% HPMC added appears to be the best of the tested choices, for three reasons: first, the viscosity of the batter is similar to that of the controls; second, the taste is not greasy after frying as the result of the reduced oil uptake and higher moisture retention; and third, the sensory characteristics of this sample, such as, color, crispiness, and hardness were the best among samples.

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF