• 제목/요약/키워드: Quality Efficiency Evaluation

검색결과 754건 처리시간 0.034초

Nondestructive Estimation of Lean Meat Yield of South Korean Pig Carcasses Using Machine Vision Technique

  • Lohumi, Santosh;Wakholi, Collins;Baek, Jong Ho;Kim, Byeoung Do;Kang, Se Joo;Kim, Hak Sung;Yun, Yeong Kwon;Lee, Wang Yeol;Yoon, Sung Ho;Cho, Byoung-Kwan
    • 한국축산식품학회지
    • /
    • 제38권5호
    • /
    • pp.1109-1119
    • /
    • 2018
  • In this paper, we report the development of a nondestructive prediction model for lean meat percentage (LMP) in Korean pig carcasses and in the major cuts using a machine vision technique. A popular vision system in the meat industry, the VCS2000 was installed in a modern Korean slaughterhouse, and the images of half carcasses were captured using three cameras from 175 selected pork carcasses (86 castrated males and 89 females). The imaged carcasses were divided into calibration (n=135) and validation (n=39) sets and a multilinear regression (MLR) analysis was utilized to develop the prediction equation from the calibration set. The efficiency of the prediction equation was then evaluated by an independent validation set. We found that the prediction equation - developed to estimate LMP in whole carcasses based on six variables - was characterized by a coefficient of determination ($R^2_v$) value of 0.77 (root-mean square error [RMSEV] of 2.12%). In addition, the predicted LMP values for the major cuts: ham, belly, and shoulder exhibited $R^2_v$ values${\geq}0.8$ (0.73 for loin parts) with low RMSEV values. However, lower accuracy ($R^2_v=0.67$) was achieved for tenderloin cuts. These results indicate that the LMP in Korean pig carcasses and major cuts can be predicted successfully using the VCS2000-based prediction equation developed here. The ultimate advantages of this technique are compatibility and speed, as the VCS2000 imaging system can be installed in any slaughterhouse with minor modifications to facilitate the on-line and real-time prediction of LMP in pig carcasses.

페이로드 시그니쳐 품질 평가를 통한 고효율 응용 시그니쳐 탐색 (High Performance Signature Generation by Quality Evaluation of Payload Signature)

  • 이성호;김종현;구영훈;;김명섭
    • 한국통신학회논문지
    • /
    • 제41권10호
    • /
    • pp.1301-1308
    • /
    • 2016
  • 인터넷 속도의 증가와 다양한 응용의 개발로 인해 인터넷 사용자와 이들이 발생시키는 인터넷 트래픽의 양이 급격히 증가하고 있다. 트래픽 분석에 있어서 트래픽 응용 식별 방법은 페이로드 시그니쳐에 의존적이기 때문에 시그니쳐의 구성이나 개수에 따라 높은 부하와 처리 속도가 느린 단점을 갖는다. 따라서 본 논문에서는 응용 식별을 위한 페이로드 시그니쳐의 중요도를 평가하는 방법과 이를 바탕으로 높은 효율의 시그니쳐를 탐색하는 방법을 제안한다. 각 시그니쳐 별로 3가지 기준을 바탕으로 가중치를 계산하고 계산된 가중치와 시그니쳐 맵을 통해 고효율의 시그니쳐 세트를 탐색한다. 제안하는 방법을 실제 트래픽에 적용했을 때 기존 대비 약 4배의 응용 식별 능력을 가진 높은 효율의 시그니쳐들을 정의할 수 있었다.

장비정도관리에 Calibrator[I-125] Set 적용 (The Application of New Calibrator[I-125]Set for Equipment Quality Management)

  • 김지나;안재석;원우재
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

대청호 주원천 인공습지의 오염물질 정화효율 평가 (Evaluation of treatment efficiencies of pollutants in daecheong lake juwon stream constructed wetlands)

  • 김태훈;성기은;하덕호;김동희;허순욱;최충식
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.211-222
    • /
    • 2015
  • This study focused on evaluating the efficiency of the removal of non-point source pollution by Daecheong Lake Juwon Stream constructed wetlands. The constructed wetland system is a surface flow type designed in the year 2007 for purifying eutrophic water of Daecheong Lake Juwon Stream. The value of conductivity, suspended solids(SS), chemical oxygen demand using a potassium permanganate($COD_{Mn}$), five-day biochemical oxygen demand($BOD_5$), total nitrogen(T-N), total phosphorous(T-P), and pH in inflow averaged 220.2, 2.46, 3.33, 1.34, 2.00, 0.04 mg/L and 7.24, respectively and in outflow averaged 227.9, 1.12, 3.34, 0.87, 1.16, 0.02 mg/L and 7.45, respectively. The average removal efficiency of constructed wetlands was 30 % for SS, 22 % for $BOD_5$, 45 % for T-N and 31 % for T-P. The removal rates of SS, $BOD_5$ and T-N in the spring, summer and autumn were higher than those in winter. The removal rate of T-P was not significant different in all seasons. The amounts of pollutants removal in the constructed wetlands were higher in the order of $3^{rd}$ < $2^{nd}$ < $1^{st}$ wetland for SS and T-P, $2^{nd}$ < $3^{rd}$ < $1^{st}$ wetland for $BOD_5$ and T-N. Therefore, our findings suggest that the constructed wetlands could well treat the eutrophic Daecheong Lake Juwon Stream waters.

Standardized Design of the Transmitting Coils in Inductive Coupled Endoscope Robot Driving Systems

  • Ke, Quan;Jiang, Pingping;Yan, Guozheng
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.835-847
    • /
    • 2017
  • A transmitting coil with an optimal topology and number of turns can effectively improve the performance of the wireless power transfer (WPT) systems for endoscope robots. This study proposes the evaluation parameters of the transmitting coils related to the performance of the WPT system to standardize the design of the transmitting coils. It considers both the quality factor of transmitting coils and the coupling factor between the two sides. Furthermore, an analytical model of transmitting coils with different topologies is built to exactly estimate the evaluation parameters. Several coils with the specified topologies are wound to verify the analytical model and the feasibility of evaluation parameters. In the case of a constant power received, the related evaluation parameters are proportional to the transfer efficiency of the WPT system. Therefore, the applicable frequency ranges of transmitting coils with different topologies are determined theoretically. Then a transmitting coil with a diameter of 69 cm is re-optimized both theoretically and experimentally. The transfer efficiency of the WPT system is increased from 3.58% to 7.37% with the maximum magnetic field intensity permitted by human tissue. Finally, the standardized design of the transmitting coil is achieved by summing-up and facilitating the optimization of the coils in various situations.

노인장기요양기관(시설급여) 평가의 품질관리를 위한 평가지표 개발 및 다층평가시스템 방안 (Development of Evaluation Index and Multi-layer Evaluation System for Quality Management of Elderly Long-term Care Institution)

  • 이상진;김윤정
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제9권11호
    • /
    • pp.1015-1026
    • /
    • 2019
  • 본 연구에서는 노인장기요양시설 평가지표개발과 관련된 선행연구의 평가현장 적용성 및 실효성이 미흡하다는 문제의식하에, 노인장기요양기관(시설급여) 평가의 품질향상을 위한 평가지표를 개발하는 데 연구의 목적이 있었다. 이를 위해 2018년도 노인장기요양기관(시설급여) 평가지표에 대한 분석적 고찰, 일본의 노인특별요양홈 평가지표에 대한 분석, 한국의 노인장기요양시설 종사자와 일본의 노인특별요양홈 종사자를 대상으로 한 평가지표 및 평가체계에 관한 FGI를 실시하였다. 연구결과를 토대로 하여 이용자가 양질의 서비스를 제공 받을 수 있도록 지원하는 측면에서 평가지표를 개발하였다. 노인의 특성, 즉 유지 및 호전되기 어려운 노인성 질환의 특성과 기관운영의 방향 및 투명성, 그리고 종말기 케어의 필요성 등을 반영하였다. 기관운영, 환경 및 안전, 수급자 권리보장, 급여제공과정, 급여제공결과를 포괄하는 43개의 평가지표를 제시하였다. 또한, 중복되고, 불필요한 평가과정을 개선하여 평가의 과정 효율성을 증가시킬 수 있는 4단계 다층평가시스템을 제안하였다.

에너지 절감형 전기히터를 활용한 동절기 양생품질 관리방안 (A Study on Cold-Weather Curing Quality Management Based on Using Energy Saving Electronic Heater)

  • 조만기;홍성민;박종훈;김진식;이동현;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2020
  • In This study, we tried to review an efficient curing method in consideration of safety and constructability among the problems of winter construction. In other words, as a result of the mock-up test, the measured value of carbon monoxide was 0 ppm in the case of an electric hot air fan. Since there is no carbon monoxide, problems such as suffocation are expected to be solved. In terms of temperature characteristics, electric hot air fans exhibited high thermal efficiency performance with a slight difference in upper/lower temperatures compared to the existing ones. In the future, we plan to conduct thermal efficiency evaluation through actual site performance verification. We will propose an efficient curing method through applicability evaluation.

  • PDF

DEA 모형을 이용한 국내 대학의 경영 효율성 평가 (The Evaluation of Administrative Efficiency of the Korean University Using DEA Model)

  • 유성진;김용희;김주훈;최정일
    • 품질경영학회지
    • /
    • 제42권4호
    • /
    • pp.647-664
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate administrative efficiency of the Korean university and to identify the factors which may affect on the efficiency of universities. In addition, last purpose of this study was to compare correlation among administrative, research and education model. Methods: The collected data through Higher Education in Korea were analysed using DEA (Data Envelopment Analysis). Furthermore, in order to provide the better accurate results by removing the bias of the results, this paper implements Bootstrap DEA. It also analyzed the causes of efficiency by Tobit Regression after setting the dependent variable as a proposed efficiency score and compared correlation analysis results between other models. Results: The results of this study are as follows; First, the Korean universities showed low administrative efficiencies. Second, efficiency of national universities are higher than it of private universities. Finally, the administrative and research education model have statistically significant correlation. However, usually many Korean universities focus their resources on education performance such as employment and rates to attract new students than research performances. Conclusion: This study shows that the administrative efficiency positively affects both research and educational efficiency. Approximately 70% of the Korean universities needs to improve their administrative efficiencies and to pay attention to enhance their poor services, low-level performances.

Does Corporate Sustainability Management Affect Investment Efficiency?

  • Oh, Hyun-Min;Park, Sam-Bock
    • 아태비즈니스연구
    • /
    • 제12권2호
    • /
    • pp.1-24
    • /
    • 2021
  • Purpose - We aim to verify whether CSM activities increase investment efficiency, and to verify whether the influence of CSM activities on investment efficiency is discriminatory depending on whether or not they belong to chaebol. Design/methodology/approach - Using 4,701 Korean firm-year observations over the 2011-2017 period, we used multiple regression analysis. CSM is measured by the evaluation score of the Korea Corporate Governance Service (KCGS). Findings - Our study confirms that CSM is a significantly positive relationship with investment efficiency. This shows that, as a result of CSM, the increased earnings quality acts as an incentive to increase investment efficiency. Next, in analysis of a dataset into two groups (a chaebol, non-chaebol), the results show that the relationship between CSM and investment efficiency differs among detailed indicator activities depending on whether or not they belong to chaebol. Research implications or Originality - It is significant that this study focused on and analyzed CSM as a determinant of investment efficiency, and examined the effects of whether or not it belongs to chaebol in the relationship between CSM and investment efficiency. Our results, which suggested that CSM can increase investment efficiency, are expected to provide important implications not only for managers but also for investors and supervisors.

고속 Line Center의 ATC 신뢰성 평가 (Reliability Evaluation of ATC for High Speed Line Center)

  • 이승우;김동훈;이화기;신동환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1914-1917
    • /
    • 2005
  • Recently, the reliability evaluation and analysis are applied for many industrial products, and many products are required to guarantee in quality and in efficiency. The purpose of this paper is to present some of reliability evaluation methodologies that are applicable to machine tools. Especially ATC(Automatic Too Changer), which is core component of line center, was chosen as the target of the reliability evaluation and analysis. The scope of research is reliability prediction, reliability test and evaluates their results. The results of this research has shown the failure rate, MTBF(Mean Time Between Failure), reliability for those components and real tests reliability through constructed reliability test-bed. It is expected that proposed methodologies will increase reliability for high speed line center.

  • PDF