The Determination of Control Limit and Testing Interval in the On-Line Quality Control of Taguchi Method (Taguchi Method의 On-Line Quality control에 있어서 관리한계 및 검사간격 결정에 대한 연구)

  • Kim, Uk-Il;Gang, Chang-Uk
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.2
    • /
    • pp.11-20
    • /
    • 1992
  • We discuss the feed back control of the on-line QC in the Taguchi method. Taguchi(1982) used the assumptions that the quality characteristics follow an uniform distribution and the Brownian motion to draw the loss function and proposed ${\Delta}/3$ or ${\Delta}$ for the initial control limit. Adams and Woodall(1989) also proposed a different procedure but using the same loss function. We propose, in this paper the new loss function under the assumption of mainly Brownian motion and compare the results with the results of the above.

  • PDF

The History and Development of the Marine Environment QA/QC (Quality Assurance/Quality Control) Management System (해양환경 정도관리제도 운영에 대한 고찰)

  • PARK, MI-OK;PARK, JUN-KUN;KIM, SEONG-GIL;KIM, SEONG-SOO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.3
    • /
    • pp.185-200
    • /
    • 2021
  • The Marine Environment QA/QC management system has been operated since 2010 to secure the reliability of data and improve the analysis capabilities of measurement and analysis institutions. From 2010 to 2020, the cumulative number of measurement and analysis institutions participated in the QA/QC management system was 266. And the number of certificates issued by the ministry of oceans and fisheries is 182. A total of 32 reference materials for proficiency testing and interlaboratory comparisons have been developed. They were first developed focusing on items (Nutrients, COD) commonly analyzed in marine environmental measuring network, marine pollution impact surveys, sea area utilization impact assessment, deepsea water surveys, and information network on fishing ground environments. In addition, it is time to expand the filed of the QA/QC management system, such as seawater temperature, salinity, PCBs and PAHs in sediments, which are mainly analyzed in most monitoring programs. On-site assessment has been conducted for 162 laboratories according to ISO/IEC 17025 to evaluate their conformity of the quality management system and deficiency. In terms of management and technology requirements, about 4.2% of organizations showed insufficient division of duties among employees 8.7% of them revealed the lack of employee training. By test item, about 6.3% of organizations showed the lack of standard substance management and the state of the cleaning glassware was pointed out in about 5.4% of them. The QA/QC management system should be continuously supplemented by identifying the causes of nonconformities and area for improvement.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

Accelerated testing for evaluating bubble quality within quartz glass crucibles used for manufacturing silicon single crystal ingots (실리콘 단결정 잉곳 제조용 석영유리 도가니 내 기포 품질평가를 위한 가속시험)

  • Gyu Bin Lee;Seung Min Kang;Jae Ho Choi;Young Min Byeon;Hyeong-Jun Kim
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.91-96
    • /
    • 2023
  • To verify the quality of bubbles during the use of quartz glass crucibles (QC), an appropriate accelerated testing method was proposed. The bubble state of discarded waste crucibles obtained from actual Czochralski (Cz) processes was analyzed, and optimal heat treatment conditions were suggested by varying temperature, pressure, and time using the QC test piece. By subjecting the samples to heat treatment at 1450℃, 0.4 Torr, and 40 hours, it was possible to control the bubble size and density to a similar level as those generated in the actual Cz process. In particular, by selecting a relatively lower pressure of 0.4 Torr compared to the typical range of 10~20 Torr applied in the Cz process, the time required for accelerated bubble formation testing could be reduced. However, it was determined that increasing the heat treatment temperature to 1550℃ led to the phenomenon of Ostwald ripening, resulting in larger bubbles and a rapid decrease in density. Therefore, it was concluded that it was not a suitable condition for the desired b ake test.

A Study on Quality Control which is Expressed in Advertisement of Residential Beds (침대 광고에 표현된 품질관리 요소에 대한 연구)

  • Rim, Kwang Soon;Kim, Jong Kuk;Choi, Joon Oh
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.3
    • /
    • pp.213-224
    • /
    • 2014
  • Advertising provides consumers with information about products, purchasing effect and criteria. Advertising of the domestic bed companies started in the 1990's and each company focused on publicizing its brand. As the times change, however, they begin to express the quality-property which consumers demanded in the advertising. This research examined the advertising trends in the domestic and foreign bed companies. Also, it presents how the quality control (QC) is reflected on the advertising of the domestic and foreign bed companies. As a result of the analysis on bed-advertising of them, the things mostly represented as a determinant of product quality are performance, shape/quality, recognition and reliability. On the side of consumers, however, service, durability and stability are mirrored in the advertising and help choose the products as the determinants.

  • PDF

The Development of Quality Assurance Program for CyberKnife (사이버나이프의 품질관리 절차서 개발)

  • Jang, Ji-Sun;Kang, Young-Nam;Shin, Dong-Oh;Kim, Moon-Chan;Yoon, Sei-Chul;Choi, Ihl-Bohng;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Kwon, Soo-Il;Lee, Dong-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.185-191
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: Standardization quality assurance (QA) program of CyberKnife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for CyberKnife and evaluation of the feasibility under applications. $\underline{Materials\;and\;Methods}$: Considering the feature of constitution for systems and the therapeutic methodology of CyberKnife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two CyberKnife centers. The acceptable tolerance was based on the undertaking inspection list from the CyberKnife manufacturer and the QC results during last three years of two CyberKnife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. $\underline{Results}$: The current QA status of two CyberKnife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. $\underline{Conclusion}$: It is considered that the developed QA program in this research could be established the standardization of QC methods for CyberKnife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy.

Quality Control of Diagnostic X-ray Equipment in Medical Field (의료분야 진단용방사선발생장치의 품질관리)

  • Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.159-164
    • /
    • 2021
  • The examination using diagnostic x-ray equipment is one of the most useful diagnostic equipment for identifying information in the human body in diagnostic radiology. For this reason, the number of examinations has recently increased a lot. Increasing the number of examinations will accelerate the aging of the device. In addition, this makes them aware of the importance of quality control for the diagnostic x-ray device. Particularly, in a diagnostic x-ray device, quality control refers to an act of always maintaining a certain level of image quality by identifying and correcting all problems that may lead to reduction of the diagnosis area in advance. Therefore, this study summarizes and reports general information about quality control in examinations using diagnostic x-ray equipment.

An Estimation of Mean Background Concentrations of Greenhouse Gases Observed on Ulleungdo (울릉도 온실기체 관측자료를 이용한 배경대기 평균농도 산정)

  • Lim, Yun-Kyu;Moon, Yun-Seob;Kim, Jin-Seog;Song, Sang-Keun;Hong, Ji-Hyung
    • Journal of the Korean earth science society
    • /
    • v.33 no.1
    • /
    • pp.32-38
    • /
    • 2012
  • Mean background concentrations of greenhouse gases such as $CO_2$ and $CH_4$ were estimated on Ulleungdo using PICARRO Cavity Ring-Down Spectroscopy (CRDS) analyzer. To improve the accuracy of $CO_2$ and $CH_4$ concentrations, a standardized QA${\cdot}$QC (Quality Assurance Quality Control) procedure was employed with three steps: 1) the inspection procedure of physical limitation (e.g. the exclusion of data corresponding to the number of data of ${\leq}$50%) for hourly mean values, 2) a stage inspection (e.g. the use of data corresponding to ${\geq}15$ observations per day) for daily mean values, and 3) a fast fourier transform (FFT) analysis using curve-fitting methods for the investigation of climatic characteristics. The monthly mean concentrations of $CO_2$ and $CH_4$ derived from three-step QA${\cdot}$QC procedure were then compared with those observed at Anmyundo (Korea) and Ryori (Japan). Overall, the error of mean $CO_2$ and $CH_4$ concentrations estimated in this study distinctly decreased. However, in comparison with their concentrations monitored at Ryori, the $CO_2$ concentration at estimated at Ulleungdo is soemwhat lower than that of Anmyundo due to the missing data, which is statistically significant. On the other hand, the former has a statistically significant higher value of $CH_4$ that of the latter.

A Study on the Ground Improvement Effective Evaluation of Reclaimed Land Using Cone Penetration Test (CPT를 이용한 준설매립지반의 개량효과 평가에 관한 연구)

  • Kim, Jong-Kook;Chae, Young-Su;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.910-921
    • /
    • 2004
  • In this study, the pilot tests on the reclaimed land were performed in order to find the suitable construction method with dynamic compaction Type I, Type II at different dynamic energy and hydraulic hammer compaction. The estimation of the compaction through the various pilot tests was performed by the CPT-qc, SPT-N and field density tests. As the result of the pilot tests, it shows that the dynamic compaction method is better than the hydraulic hammer compaction method in the effect of the ground improvement, especially dynamic compaction Type I is much superior to others. When it comes to method for measuring the intensity of the ground, the value of the cone penetration test-resistance(qc) is much suitable for the ground. Besides, the standards for the compaction control, which showed that over 10Mpa at 0 through 5meters in the upper layer and 7Mpa at 5 through 8meters in the lower layer in the CPT-qc, could be found without discrimination of the upper road and lower road on the reclaimed land. And it also found that the intensity of the reclaimed land gets back to the original status in about 10 through 15 days.

  • PDF